1.
Strahlenther Onkol ; 190(5): 459-66, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24599345

RESUMO

AIM: The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. BACKGROUND: Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. MATERIALS AND METHODS: The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. RESULTS: The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: (56)Mn in the stainless steel and (187)W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 µSv from activated radionuclides. CONCLUSION: Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once.


Assuntos
Nêutrons Rápidos/uso terapêutico , Raios gama/uso terapêutico , Neoplasias/radioterapia , Teleterapia por Radioisótopo/métodos , Radioterapia de Alta Energia/métodos , Irradiação Corporal Total/métodos , Fracionamento da Dose de Radiação , Física Médica , Humanos , Análise de Ativação de Nêutrons , Teleterapia por Radioisótopo/instrumentação , Radiometria , Dosagem Radioterapêutica , Radioterapia de Alta Energia/instrumentação , Análise Espectral , Irradiação Corporal Total/instrumentação
2.
Phys Rev Lett ; 105(12): 122001, 2010 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-20867630

RESUMO

Taking advantage of both the low-emittance proton beam of the cooler synchrotron COSY and the high momentum precision of the COSY-11 detector system, the mass distribution of the η' meson was measured with a resolution of 0.33 MeV/c2 (FWHM), improving the experimental mass resolution by almost an order of magnitude with respect to previous results. Based on the sample of more than 2300 reconstructed pp → ppη' events, the total width of the η' meson was determined to be Γ(η') = 0.226 ± 0.017(stat) ± 0.014(syst) MeV/c2.

3.
Appl Radiat Isot ; 68(4-5): 854-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20056430

RESUMO

Studies of radon isotope (222)Rn activity concentration in underground water in the Sudety region were performed with the use of the liquid scintillation technique. Waters chosen for investigations were collected in 24 health resorts and towns of the Sudety area from 115 springs, wells and intakes. The (222)Rn activity concentration varied within the range from 4.2+/-0.4 to 1703+/-55 Bq/l. The annual effective doses due to the consumption of (222)Rn with water were calculated for 50 sources of underground spring water or tap water used for consumption. The results were within the range from 0.003 to 1.1 mSv/yr, assuming 0.5 l of tap water per day from which radon is not removed or 0.5 l of mineral spring water consumed daily. The contribution to the effective dose from the inhalation of radon during the daily usage of domestic water substantially increases its effective dose.


Assuntos
Balneologia/estatística & dados numéricos , Carga Corporal (Radioterapia) , Exposição Ambiental/análise , Exposição Ambiental/estatística & dados numéricos , Água Doce/análise , Monitoramento de Radiação/estatística & dados numéricos , Radônio/análise , Humanos , Polônia , Doses de Radiação
4.
Appl Radiat Isot ; 68(4-5): 839-43, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19864151

RESUMO

The investigations of natural radioactivity in underground mineral water and spring water in health resorts in the Outer Carpathians were performed. Samples from 40 water springs were collected 3-4 times over a period of 10 years (1997-2007). In order to obtain necessary data, two different nuclear spectrometry techniques were applied: WinSpectral alphabeta 1414 liquid scintillation counter from Wallac and alpha-spectrometer 7401 VR from Canberra-Packard, USA with the silicon surface barrier detector. The activity concentrations of (222)Rn in the investigated samples varied from below 1 to 50 Bq/l. For radium isotopes the concentrations were in a range from below 10 to 490 mBq/l for (226)Ra and from 29 to 397 mBq/l for (228)Ra. The highest concentrations for both radium isotopes were obtained for medicinal water Zuber III from Krynica spa. The activity concentrations for uranium isotopes varied from below 0.5 to 16 mBq/l for (238)U and from below 0.5 to 162 mBq/l for (234)U with the highest values obtained for water Zuber IV. The highest annual effective dose arising from mainly radium isotopes was obtained for Zuber III water and was equal to 75 microSv/yr. Additionally, the annual effective doses due to (222)Rn consumed with water were also estimated. The isotopic ratios between isotopes originating from the same decay chain ((234)U/(238)U, (226)Ra/(238)U) and from different radioactive decay chains ((226)Ra/(228)Ra) were determined. The correlations between different isotopes were presented.


Assuntos
Radiação de Fundo , Água Doce/química , Monitoramento de Radiação/métodos , Contagem de Cintilação/métodos , Análise Espectral/métodos , Poluentes Radioativos da Água/análise , Água Doce/análise , Polônia , Doses de Radiação
5.
Appl Radiat Isot ; 68(4-5): 763-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19833525

RESUMO

Dependence between therapeutic dose and activity induced in mammal bones is discussed. This activity leads to gamma ray emission registered by HPGe detector and scintilation probe. Presented results are focused on activation which occurs during emission of 15 and 20 MV photon beams. The purpose is to describe how therapeutic conditions (dose, time of irradiation) influence the induced radioactivity. Preliminary studies of decay rate, calculation of half-life and identification of isotopes involved in this dynamic process are given.


Assuntos
Osso e Ossos/fisiologia , Osso e Ossos/efeitos da radiação , Aceleradores de Partículas , Tolerância a Radiação/fisiologia , Tolerância a Radiação/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Humanos , Doses de Radiação
6.
Phys Rev Lett ; 101(26): 262701, 2008 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-19437637

RESUMO

A new reaction mechanism of violent reseparation of a heavy nucleus-nucleus system, 197Au + 197Au, into three or four massive fragments in collisions at 15 MeV/nucleon has been observed. After reseparation, the fragments are almost exactly aligned, thus showing a very short time scale of the reseparation process, of about 70-80 fm/c.

7.
Phys Rev Lett ; 98(12): 122003, 2007 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-17501114

RESUMO

Measurements of the analyzing power for the pp-->pp eta reaction have been performed at excess energies of Q=10 and 36 MeV. The determined analyzing power is essentially consistent with zero, implying dominance of the s wave at both excess energies. The angular dependence of the analyzing power, combined with the isospin dependence of the total cross section for the eta meson production in nucleon-nucleon collisions, reveal that the excitation of the nucleon to the S11(1535) resonance is predominantly due to the exchange of the pi meson between the colliding nucleons.

8.
Appl Radiat Isot ; 51(4): 475-80, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10464918

RESUMO

A method involving a Wallac 1414 WinSpectral alpha/beta liquid scintillation counter for determining 222Rn in aqueous samples is described. Samples were collected from 23 springs and 4 taps in health resorts of the Klodzka valley in the Sudety mountains in Poland. Half of the investigated spring water samples were radon enriched with an activity concentration higher than 74 Bq/l. In the tap waters the radon concentration level is very low or below the lower limit of detection. Owing to the statistical nature of radioactive decay the uncertainty of the measurement was determined as the standard deviation of 222Rn activity. The method introduced is fast and simple and does not require a chemical sample preparation procedure.


Assuntos
Água Doce/análise , Estâncias para Tratamento de Saúde , Radônio/análise , Contagem de Cintilação , Polônia , Contagem de Cintilação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...