Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hand (N Y) ; 13(4): 455-460, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-28549397

RESUMO

BACKGROUND: The brachioradialis (BR) wrap technique is an option to restore the stability of the distal radioulnar joint (DRUJ). The technique capitalizes on the BR's advantageous insertion point on the radial styloid and the ability of the BR to be harvested with minimal to no deficit. The tendon can then be wrapped around the radius and ulna, tunneling under the pronator quadratus and extensor compartments and secured back into its insertion to provide stability. In this cadaveric study, we used micro-computed tomography (CT) to assess the stability restored by this procedure. METHODS: Axial CT scans were taken of cadaveric specimens (n = 10) in 3 different positions (neutral, 60° pronation, and 60° supination) to establish the baseline measurements of each DRUJ. Surgical disruption of the dorsal and volar ligaments of each DRUJ then simulated a destabilizing injury and the specimens were scanned again. The specimens then underwent the BR wrap procedure and were scanned once more. Degree of ulnar subluxation with respect to the Sigmoid notch was determined using the modified radioulnar line method. RESULTS: The mean percentages of subluxation in the neutral position for the normal, injured, and reconstructed DRUJ were 22.4±4.9%, 56.2±12.9%, and 29.0±6.5%, respectively. In 60° pronation, these values were 15.4±4.7%, 53.5±15.0%, and 36.5±11.8%, respectively. In 60° supination, these values were 18.6±2.5%, 69.7±20.5%, and 31.9±8.7%, respectively. CONCLUSIONS: Values differed significantly between normal and injured conditions in all positions. No significant difference was noted between normal and reconstructed conditions, suggesting reconstruction improves DRUJ biomechanics and more closely approximates normal stability.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Transferência Tendinosa/métodos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Cadáver , Humanos , Instabilidade Articular/fisiopatologia , Pronação , Supinação , Articulação do Punho/fisiopatologia , Microtomografia por Raio-X
2.
Ann Thorac Surg ; 99(6): 1961-7; discussion 1967-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25921254

RESUMO

BACKGROUND: Ex vivo lung perfusion (EVLP) has the potential to increase the donor pool for lung transplantation by facilitating resuscitation and extended evaluation of marginal organs. Current EVLP methodology employs continuous flow (CF) pumps that produce non-pulsatile EVLP hemodynamics. In this feasibility study, we tested the hypothesis that a pulsatile flow (PF) pump will provide better EVLP support than a CF pump through delivery of physiologic hemodynamics. METHODS: Porcine lungs were supported in an EVLP model by centrifugal CF (n = 3) or PF (n = 4) left ventricular assist devices. Lungs were ventilated at 4 to 5 mL/kg, 0.21 fraction of inspired oxygen (FiO2), and perfused with an acellular, albumin-based solution corrected for osmolarity, acid-base balance, and carbon dioxide pressure (≤20 hours at 30°C) for a minimum of 12 hours support. Prostaglandin E1 and 30% albumin were infused continuously. Hemodynamic, respiratory, and blood gas parameters were continuously monitored and digitally recorded hourly. Parenchymal biopsies were used for quantification of wet to dry weight ratio. RESULTS: All lungs maintained function in the EVLP circuit for a minimum of 12 hours (mean 14.7 ± 1 hours) and demonstrated minimal edema formation. The PF EVLP produced higher pulsatility as demonstrated by greater energy equivalent pressure and surplus hemodynamic energy compared with CF EVLP (p < 0.05). There were no statistically significant differences in pulmonary impedance, arterial partial pressure of oxygen/fraction of inspired oxygen, wet to dry weight ratio, and peak airway pressure between CF and PF EVLP. CONCLUSIONS: The CF and PF EVLP systems successfully maintained lungs 12+ hours using a modified Steen perfusate (XVIVO Perfusion, Inc, Goteborg, Sweden); however, there were no statistically significant differences between CF and PF groups despite higher pulsatility, suggesting that PF may not offer immediate benefits over CF for prolonged ex vivo lung preservation.


Assuntos
Ventrículos do Coração/cirurgia , Coração Auxiliar , Transplante de Pulmão/métodos , Pulmão/fisiologia , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Animais , Estudos de Viabilidade , Seguimentos , Masculino , Desenho de Prótese , Fluxo Pulsátil/fisiologia , Suínos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...