RESUMO

BACKGROUND: Video-assisted thoracoscopic surgery (VATS) for pulmonary nodules close to the visceral pleura is an established procedure. Different methods have been developed to mark these nodules when resecting small nodules distant to the pleural surface. The possibility of tumor cell spread due to nodule penetration is a major drawback. Furthermore, guide wire-based marking systems have revealed the problem of accidental wire dislocation prior to resection. METHODS: In this study, a new marker system for computed tomography-guided extranodular spiral fixed wire marking (ESFWM) was evaluated in an attempt to maintain tumor integrity while reducing the risk of wire dislocation. RESULTS: Our study included 42 patients with 44 marked nodules. 40 nodules were resected by VATS in 38 of these patients. The remaining 4 patients required conversion to thoracotomy due to adhesions and a non-deflated lung. Wire dislocation and nodule penetration occurred only once. CONCLUSION: The new lung marker system revealed a very low risk of wire dislocation. Peritumoral marking allows the safe resection of subpleural nodules without a risk of tumor cell spread.


Assuntos
Neoplasias Pulmonares/cirurgia , Cuidados Pré-Operatórios/instrumentação , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Desenho de Equipamento , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Excisão de Linfonodo , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Radiografia , Radiologia Intervencionista , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem
2.
Rofo ; 177(4): 501-6, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15838754

RESUMO

PURPOSE: The well-defined model of angioplasty and stent implantation in the rabbit aorta is useful in experimental studies of restenosis. This study was performed to evaluate the feasibility of Micro-CT for quantification of in-stent restenosis in a rabbit aortic in-stent-restenosis model. MATERIAL AND METHODS: To induce in-stent restenosis seven female New Zealand rabbits underwent balloon dilation and denudation prior to stenting the abdominal aorta. After six weeks on atherogenic diet, animals were killed and the aorta was perfused with contrast agent. Micro-CT morphometric analysis of balloon and stent injured arteries obtained by 700 transverse sections (voxel size 10 microm) was compared to conventional histological analysis. RESULTS: Intimal hyperplasia was present in stented and balloon injured arteries with a moderate intimal area assessed by Micro-CT and conventional histology (3.91 +/- 0.5 mm(2) vs. 4.18 +/- 0.42; r = 0.9). High significant correlations between Micro-CT image analysis and conventional histomorphometry were obtained for lesion size, size of media, size of lumen and stent area (r = 0.84 to 0.96). CONCLUSION: Micro-CT is feasible for quantitative information about restenosis following balloon angioplasty and stent implantation and has the potential to become a standard technique in many laboratories which will augment serial histology as the reference method for ex-vivo studies of restenosis.


Assuntos
Algoritmos , Angioplastia Coronária com Balão/efeitos adversos , Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents/efeitos adversos , Animais , Estudos de Viabilidade , Oclusão de Enxerto Vascular/patologia , Coelhos , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença