Anal Chem ; 94(20): 7200-7209, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35549212

RESUMO

In this study, we measure the absolute isotope ratios of ytterbium (Yb) by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) using an optimized regression model for mass bias correction. A rhenium (Re) reference material (NIST SRM 3143), which has been characterized previously, is selected as a primary calibrator to calibrate the absolute Yb isotope ratios for three Yb materials (GSB, Alfa Yb, and GBW). The three-isotope plot for all collected data indicates that the results of Yb isotope ratios obtained are not affected by any polyatomic interferences and the mass-independent isotopic fractionation. Furthermore, the recalibrated Hf historical isotope ratios by using the absolute Yb isotopic composition obtained in this study for the isobaric interference correction on Hf isotopes are in agreement with the original historical values. This work has further demonstrated the applicability of the regression model for the calibrated measurements of absolute isotope ratios using MC-ICP-MS. The three mono-elemental Yb standard solutions are thus proposed as the reference materials for Yb isotope ratio measurements in environmental and geoscience applications.


Assuntos
Isótopos , Itérbio , Isótopos/análise , Espectrometria de Massas/métodos , Análise Espectral
3.
Anal Chem ; 94(2): 1286-1293, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34961322

RESUMO

Using boron as a test analyte, laser ablation (LA) solution sampling multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is proposed and validated as a fast method for isotopic analysis in natural liquids and digested samples without any prior purification process. We demonstrated that the solution reference standard can be used as a bracketing standard for in situ δ11B analysis in solids. Based on a sensitivity enhancement of 8- to 9-fold, all testing solutions were diluted in a 5% (v/v) NH3·H2O instead of classical 2% (v/v) HNO3. With a discrete and minimal sample solvent loading by the LA sampling strategy, it produces nearly "dry" plasma conditions that tolerate the sample matrix remarkably. The memory effect, one of the most difficult challenges in boron analysis, was dramatically eliminated with only 15 s wash time; thus, each analysis took less than 100 s. No significant matrix effects were observed for varying 50-100% boron concentrations in the samples and varying 20-60% NH3·H2O matrix used for the dilution, as well as for samples doped with a 1/100 synthetic seawater matrix. The external precision of δ11B measurements in NIST 951a was ± 0.30‰ (2SD). Good agreement with the values described in literature studies was achieved for δ11B measurements in eight geological reference materials, with precisions between 0.4 and 0.7‰ (2SD), confirming the accuracy of the proposed method. The proposed method offers advantages of simple sample preparation, fast analysis, and little use of chemical reagents.


Assuntos
Boro , Terapia a Laser , Boro/química , Espectrometria de Massas/métodos , Água do Mar , Manejo de Espécimes
5.
Anal Chem ; 90(15): 9016-9024, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29986584

RESUMO

The U-Pb geochronologic analysis of accessory minerals has played an important role in Earth and solar system science in constraining the ages of a wide variety of rocks and minerals. Laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is one of the most popular techniques for U-Pb geochronologic analysis. Currently, the significant matrix effects observed between different accessory minerals and the lack of high-quality standards for many minerals of interest are the major limitations of its geochronological applications. In this study, we investigated the effects of the addition of oxygen, nitrogen, and water vapor before and after the ablation cell on the accuracy of the U-Pb dating of different minerals (e.g., zircon, monazite, titanite, and xenotime) by LA-ICP-MS. We found that the addition of water vapor, unlike that of oxygen and nitrogen, before the ablation cell can significantly suppress the matrix effects on U-Pb dating. The deviations of the measured 206Pb/238U ratios in these accessory minerals were significantly reduced from 10 to 24% to less than 1-2% when using NIST 610 glass as an external standard. This can be attributed to the suppression of elemental fractionation in both the laser ablation and ICP ionization processes by the presence of water vapor. The developed water vapor-assisted LA-ICPMS U-Pb dating method has been successfully applied to the analysis of zircon, monazite, xenotime, and titanite with NIST 610 glass as a reference material in both the 193 nm excimer laser and 213 nm Nd:YAG laser ablation systems.

6.
Anal Chim Acta ; 948: 9-18, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27871614

RESUMO

In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204Hg on 204Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20xPb/204Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20xPb/206Pb and <0.06% (RSD, k = 2) for 20xPb/204Pb with the exception of 20xPb/204Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 µg g-1) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 µg g-1). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol.

7.
Anal Chem ; 88(20): 10088-10094, 2016 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-27628671

RESUMO

Sample preparation of whole-rock powders is the major limitation for their accurate and precise elemental analysis by laser ablation inductively-coupled plasma mass spectrometry (ICPMS). In this study, a green, efficient, and simplified fusion technique using a high energy infrared laser was developed for major and trace elemental analysis. Fusion takes only tens of milliseconds for each sample. Compared to the pressed pellet sample preparation, the analytical precision of the developed laser fusion technique is higher by an order of magnitude for most elements in granodiorite GSP-2. Analytical results obtained for five USGS reference materials (ranging from mafic to intermediate to felsic) using the laser fusion technique generally agree with recommended values with discrepancies of less than 10% for most elements. However, high losses (20-70%) of highly volatile elements (Zn and Pb) and the transition metal Cu are observed. The achieved precision is within 5% for major elements and within 15% for most trace elements. Direct laser fusion of rock powders is a green and notably simple method to obtain homogeneous samples, which will significantly accelerate the application of laser ablation ICPMS for whole-rock sample analysis.

8.
Anal Chim Acta ; 911: 14-26, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26893082

RESUMO

The sulfur isotope is an important geochemical tracer in diverse fields of geosciences. In this study, the effects of three different cone combinations with the addition of N2 on the performance of in situ S isotope analyses were investigated in detail. The signal intensities of S isotopes were improved by a factor of 2.3 and 3.6 using the X skimmer cone combined with the standard sample cone or the Jet sample cone, respectively, compared with the standard arrangement (H skimmer cone combined with the standard sample cone). This signal enhancement is important for the improvement of the precision and accuracy of in situ S isotope analysis at high spatial resolution. Different cone combinations have a significant effect on the mass bias and mass bias stability for S isotopes. Poor precisions of S isotope ratios were obtained using the Jet and X cones combination at their corresponding optimum makeup gas flow when using Ar plasma only. The addition of 4-8 ml min(-1) nitrogen to the central gas flow in laser ablation MC-ICP-MS was found to significantly enlarge the mass bias stability zone at their corresponding optimum makeup gas flow in these three different cone combinations. The polyatomic interferences of OO, SH, OOH were also significantly reduced, and the interference free plateaus of sulfur isotopes became broader and flatter in the nitrogen mode (N2 = 4 ml min(-1)). However, the signal intensity of S was not increased by the addition of nitrogen in this study. The laser fluence and ablation mode had significant effects on sulfur isotope fractionation during the analysis of sulfides and elemental sulfur by laser ablation MC-ICP-MS. The matrix effect among different sulfides and elemental sulfur was observed, but could be significantly reduced by line scan ablation in preference to single spot ablation under the optimized fluence. It is recommended that the d90 values of the particles in pressed powder pellets for accurate and precise S isotope analysis should be less than 10 µm. Under the selected optimized analytical conditions, excellent agreements between the determined values and the reference values were achieved for the IAEA-S series standard reference materials and a set of six well-characterized, isotopic homogeneous sulfide standards (PPP-1, MoS2, MASS-1, P-GBW07267, P-GBW07268, P-GBW07270), validating the capability of the developed method for providing high-quality in situ S isotope data in sulfides and elemental sulfur.

9.
Sci Rep ; 5: 11547, 2015 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-26100577

RESUMO

Carbon in rocks and its rate of exchange with the exosphere is the least understood part of the carbon cycle. The amount of carbonate subducted as sediments and ocean crust is poorly known, but essential to mass balance the cycle. We describe carbonatite melt pockets in mantle peridotite xenoliths from Dalihu (northern China), which provide firsthand evidence for the recycling of carbonate sediments within the subduction system. These pockets retain the low trace element contents and δ(18)OSMOW = 21.1 ± 0.3 of argillaceous carbonate sediments, representing wholesale melting of carbonates instead of filtered recycling of carbon by redox freezing and melting. They also contain microscopic diamonds, partly transformed to graphite, indicating that depths >120 km were reached, as well as a bizarre mixture of carbides and metal alloys indicative of extremely reducing conditions. Subducted carbonates form diapirs that move rapidly upwards through the mantle wedge, reacting with peridotite, assimilating silicate minerals and releasing CO2, thus promoting their rapid emplacement. The assimilation process produces very local disequilibrium and divergent redox conditions that result in carbides and metal alloys, which help to interpret other occurrences of rock exhumed from ultra-deep conditions.

10.
Anal Chem ; 87(2): 1152-7, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25511501

RESUMO

A novel "wave" signal-smoothing and mercury-removing device has been developed for laser ablation quadrupole and multiple collector ICPMS analysis. With the wave stabilizer that has been developed, the signal stability was improved by a factor of 6.6-10 and no oscillation of the signal intensity was observed at a repetition rate of 1 Hz. Another advantage of the wave stabilizer is that the signal decay time is similar to that without the signal-smoothing device (increased by only 1-2 s for a signal decay of approximately 4 orders of magnitude). Most of the normalized elemental signals (relative to those without the stabilizer) lie within the range of 0.95-1.0 with the wave stabilizer. Thus, the wave stabilizer device does not significantly affect the aerosol transport efficiency. These findings indicate that this device is well-suited for routine optimization of ICPMS, as well as low repetition rate laser ablation analysis, which provides smaller elemental fractionation and better spatial resolution. With the wave signal-smoothing and mercury-removing device, the mercury gas background is reduced by 1 order of magnitude. More importantly, the (202)Hg signal intensity produced in the sulfide standard MASS-1 by laser ablation is reduced from 256 to 0.7 mV by the use of the wave signal-smoothing and mercury-removing device. This result suggests that the mercury is almost completely removed from the sample aerosol particles produced by laser ablation with the operation of the wave mercury-removing device. The wave mercury-removing device that we have designed is very important for Pb isotope ratio and accessory mineral U-Pb dating analysis, where removal of the mercury from the background gas and sample aerosol particles is highly desired. The wave signal-smoothing and mercury-removing device was applied successfully to the determination of the (206)Pb/(204)Pb isotope ratio in samples with low Pb content and/or high Hg content.

11.
Nat Commun ; 5: 5604, 2014 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-25517619

RESUMO

We report partial melting of an ultrahigh pressure eclogite in the Mesozoic Sulu orogen, China. Eclogitic migmatite shows successive stages of initial intragranular and grain boundary melt droplets, which grow into a three-dimensional interconnected intergranular network, then segregate and accumulate in pressure shadow areas and then merge to form melt channels and dikes that transport magma to higher in the lithosphere. Here we show, using zircon U-Pb dating and petrological analyses, that partial melting occurred at 228-219 Myr ago, shortly after peak metamorphism at 230 Myr ago. The melts and residues are complimentarily enriched and depleted in light rare earth element (LREE) compared with the original rock. Partial melting of deeply subducted eclogite is an important process in determining the rheological structure and mechanical behaviour of subducted lithosphere and its rapid exhumation, controlling the flow of deep lithospheric material, and for generation of melts from the upper mantle, potentially contributing to arc magmatism and growth of continental crust.