Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 447: 139020, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38513477

RESUMO

Carbon quantum dots (CQDs) have significant applications in nanozymes. However, previous studies have not elucidated the structure-activity relationship and enzyme mechanism. In this study, we employed a one-step microwave method to synthesize ultra-trace Ag-doped carbon quantum dots (Ag-CQDs). In the presence of hydrogen peroxide (H2O2), we used the oxidative coupling reaction of 3,3',5,5'-tetramethylbenzidine (TMB) to evaluate the intrinsic peroxidase-like activity, kinetics, and mechanism of Ag-CQDs. The trace amount of doped Ag (1.64 %) facilitated electron transfer from the CQDs interior to the surface. The electron transfer triggered the peroxide activity of CQDs, producing hydroxyl radical (·OH), which oxidized the colorless TMB to blue-colored TMB (oxTMB). By coupling with glucose oxidase (GOx), the Ag-CQDs/H2O2/TMB system has been used for colorimetric glucose determination. The system demonstrated a low detection limit (0.17 µM), wide linear range (0.5-5.5 µM), and satisfactory results when fruit juice was analyzed. This study reports a feasible method for the colorimetric detection of glucose by synthesizing ultra-trace Ag-doped carbon quantum dots with peroxidase-mimicking activity.


Assuntos
Glucose , Pontos Quânticos , Carbono , Peróxido de Hidrogênio , Colorimetria/métodos , Peroxidases , Peroxidase
2.
Chemosphere ; 338: 139452, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37437625

RESUMO

Employing cheap Cu nanoclusters to design a novel fluorescent probe have promising opportunities in the field of optical sensors. Here, we fabricated a highly photoluminescent D-tryptophan (D-Trp)-coated Cu nanoclusters (Trp-Cu NCs) by rapid microwave-assisted method to achieve precise quantification of tetracyclines (TC). Due to protecting groups of Trp, the synthesized Trp-Cu NCs have remarkable fluorescence stability with a quantum yield reached 12.5%. A distinct fluorescence quenching with the incremental addition of TC via the internal filtration effect (IFE). Based on turn-off fluorescence within 1 min, a detection method for detecting TC was constructed with a linear range of 0.3-120 µM and a limit of detection (LOD) of 0.12 µM. Besides, the proposed fluorescent probe has been employed for the determination of practical samples such as water samples, milk and honey, and exhibited satisfactory recoveries of 96.1%-108.2%, with relative standard deviations (RSD) lower than 5.0%. This is a sensitive, rapid and easily recognizable Trp-Cu NCs based sensing platform for the determination of TC, which could offer a powerful tool for ensuring food safety.


Assuntos
Cobre , Nanopartículas Metálicas , Corantes Fluorescentes , Triptofano , Limite de Detecção , Espectrometria de Fluorescência/métodos
3.
Chemosphere ; 338: 139451, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37451632

RESUMO

An off-on fluorescent probe (NS-CDs-AgNPs) was synthesized based on a one-pot microwave process by utilizing N, S co-doping carbon dots (NS-CDs) and silver nitrate as precursors. The significant peak of NS-CDs-AgNPs at 393 nm in ultraviolet spectrum indicated silver nanoparticle (AgNPs) were successfully synthesized. A faint blue fluorescence emission (442 nm) was displayed when excited NS-CDs-AgNPs at 371 nm. A remarkable fluorescence recovery was observed upon adding of trance Hg2+, whereas the other heavy metal ions did not elicit this response. The reason for this phenomenon was revealed in this work that a spontaneous redox reaction occurred between NS-CDs-AgNPs and Hg2+, which leaded to the formation of NS-CDs-Agn-2NPsHg complexes. On the basis of this mechanism, a new off-on fluorescent analytical method was constructed for Hg2+ detection with linear range of 10-400 nM (R2 = 0.9941), and the detection limit (LOD) of 5.16 nM. Additionally, satisfactory recovery (90.28%-106.13%) and the relative standard deviation (RSD) (RSD<5.21%) were obtained in water sample detection. More importantly, the NS-CDs-AgNPs exhibited lower cytotoxicity and better biocompatibility, indicating a huge potential in cell imaging and clinical medicine.


Assuntos
Mercúrio , Nanopartículas Metálicas , Pontos Quânticos , Corantes Fluorescentes , Carbono , Micro-Ondas , Espectrometria de Fluorescência/métodos , Limite de Detecção , Prata
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...