Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Anesth ; 31: 53-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27185678

RESUMO

BACKGROUND: The recently approved subcutaneous implantable cardioverter/defibrillator (S-ICD) uses a single extrathoracic subcutaneous lead to treat life-threatening ventricular arrhythmias, such as ventricular tachycardia and ventricular fibrillation. This is different from conventional transvenous ICDs, which are typically implanted under sedation. Currently, there are no reports regarding the anesthetic management of patients undergoing S-ICD implantation. STUDY OBJECTIVES: This study describes the anesthetic management and outcomes in patients undergoing S-ICD implantation and defibrillation threshold (DFT) testing. METHODS: The study population consists of 73 patients who underwent S-ICD implantation. General anesthesia (n = 69, 95%) or conscious/deep sedation (n = 4, 5%) was used for device implantation. MEASUREMENTS: Systolic blood pressure (SBP) and heart rate were recorded periprocedurally for S-ICD implantation and DFTs. Major adverse events were SBP <90 mm Hg refractory to vasopressor agents, significant bradycardia (heart rate <45 beats per minute) requiring pharmacologic intervention and, "severe" pain at the lead tunneling site and the S-ICD generator insertion site based on patient perception. INTERVENTIONS: Of the 73 patients, 39 had SBP <90 mm Hg (53%), and intermittent boluses of vasopressors and inotropes were administered with recovery of SBP. In 2 patients, SBP did not respond, and the patients required vasopressor infusion in the intensive care unit. MAIN RESULTS: Although the S-ICD procedure involved extensive tunneling and a mean of 2.5 ± 1.7 DFTs per patient, refractory hypotension was a major adverse event in only 2 patients. The mean baseline SBP was 132.5 ± 22.0 mm Hg, and the mean minimum SBP during the procedure was 97.3 ± 9.2 mm Hg (P < .01). There was also a mean 13-beats per minute decrease in heart rate (P < .01), but no pharmacologic intervention was required. Eight patients developed "severe" pain at the lead tunneling and generator insertion sites and were adequately managed with intravenous morphine. CONCLUSIONS: Among a heterogeneous population, anesthesiologists can safely manage patients undergoing S-ICD implantation and repeated DFTs without wide swings in SBP and with minimal intermittent pharmacologic support.


Assuntos
Anestesia Geral/métodos , Arritmias Cardíacas/terapia , Sedação Consciente/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Pressão Sanguínea/fisiologia , Bradicardia/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...