Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Imaging Radiat Oncol ; 25: 100419, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36875326

RESUMO

Background and purpose: Deep inspiration breath-hold (DIBH) is a technique that is widely utilised to spare the heart and lungs during breast radiotherapy. In this study, a method was developed to validate directly the intrafraction accuracy of DIBH during breast volumetric modulated arc therapy (VMAT) via internal chest wall (CW) monitoring. Materials and methods: In-house software was developed to automatically extract and compare the treatment position of the CW in cine-mode electronic portal image device (EPID) images with the planned CW position in digitally reconstructed radiographs (DRR) for breast VMAT treatments. Feasibility of this method was established by evaluating the percentage of total dose delivered to the target volume when the CW was sufficiently visible for monitoring. Geometric accuracy of the approach was quantified by applying known displacements to an anthropomorphic thorax phantom. The software was used to evaluate (offline) the geometric treatment accuracy for ten patients treated using real-time position management (RPM)-guided DIBH. Results: The CW could be monitored within the tangential sub-arcs which delivered a median 89% (range 73% to 97%) of the dose to target volume. The phantom measurements showed a geometric accuracy within 1 mm, with visual inspection showing good agreement between the software-derived and user-determined CW positions. For the RPM-guided DIBH treatments, the CW was found to be within ±5 mm of the planned position in 97% of EPID frames in which the CW was visible. Conclusion: An intrafraction monitoring method with sub-millimetre accuracy was successfully developed to validate target positioning during breast VMAT DIBH.

2.
Phys Med Biol ; 68(3)2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36595255

RESUMO

Objective.The aim of this work was to develop and validate a method for remote dosimetric auditing that enables dose-volume histogram parameter comparisons of measured and planned dose in the patient CT volume.Approach. The method is derived by adapting and combining a remote electronic portal imaging (EPID) based auditing method (Virtual Epid based Standard Phantom Audit-VESPA) and a method to estimate 3D in-patient dose distributions from planar dosimetric measurements. The method was tested with a series of error-induced plans including monitor unit and multileaf collimator (MLC) positioning errors. A pilot audit study was conducted with eleven radiotherapy centres. IMRT plans from two clinical trials, a post-prostatectomy (RAVES trial) plan and a head and neck (HPV trial) plan were utilized. Clinically relevant DVH parameters for the planned dose and estimated measured dose were compared.Main results. The method was found to reproduce the induced dose errors within 0.5% and was sensitive to MLC positioning errors as small as 0.5 mm. For the RAVES plan audit all DVH results except one were within 3% and for the HPV plan audit all DVH results were within 3% except three with a maximum difference of 3.2%.Significance. The results from the audit method produce clinically meaningful DVH metrics for the audited plan and could enable an improved understanding of a centre's radiotherapy quality.


Assuntos
Infecções por Papillomavirus , Radioterapia de Intensidade Modulada , Masculino , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria
3.
Tissue Antigens ; 81(4): 230-1, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23510421

RESUMO

The HLA-B*44:02:27 allele strongly resembles the HLA-B*44:02:01:01 allele with respect to HLA-C association and haplotype constitution.


Assuntos
Alelos , Antígenos HLA-B/genética , Mutação Puntual , Sequência de Bases , Éxons , Antígenos HLA-B/imunologia , Teste de Histocompatibilidade , Humanos , Dados de Sequência Molecular , Transplante de Células-Tronco , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...