1.
Artigo em Inglês | MEDLINE | ID: mdl-39001922

RESUMO

PURPOSE: This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP). METHODS: Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. RESULTS: 103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA4 ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA4 ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA4 ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA4 (post-operative minus pre-operative BC PTA4) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA4 deterioration of 11.3 dB HL. CONCLUSION: The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.

2.
Eur Arch Otorhinolaryngol ; 281(5): 2353-2363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133806

RESUMO

PURPOSE: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis. METHODS: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE). RESULTS: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA4 ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA4 thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA4 ABG of ≤ 20 dB. None of the children reported a BC PTA4 deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days. CONCLUSION: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults. TRIAL REGISTRATION NUMBER: NCT05565339, 09 September 2022, retrospectively registered.


Assuntos
Prótese Ossicular , Adulto , Criança , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Implantação de Prótese , Condução Óssea , Audiometria de Tons Puros
3.
J Pers Med ; 13(6)2023 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-37373894

RESUMO

In post-mortem analyses, SARS-CoV-2 was found in the middle ear of some, but not all, patients with COVID-19. It is not clear whether SARS-CoV-2 penetrated the ear passively post mortem, or existed in the middle ear of living patients during, and perhaps also after, infection. This study investigated whether SARS-CoV-2 can be found in the middle ear of living patients during ear surgery. Swabs from the nasopharynx, the filter connected to the tracheal tube and secretions from the middle ear were collected during middle ear surgery. All samples were tested for the presence of SARS-CoV-2 using PCR. History of vaccination, COVID-19 history and contact with SARS-CoV-2-positive individuals were recorded preoperatively. Postoperative SARS-CoV-2 infection was noted at the follow-up visit. Overall, 63 participants (62%) were children and 39 (38%) were adults. SARS-CoV-2 was found in the middle ear and in the nasopharynx of two and four CovEar study participants, respectively. The filter connected to the tracheal tube was sterile in all cases. Cycle threshold (ct) values of the PCR test were between 25.94 and 37.06. SARS-CoV-2 penetrated the middle ear of living patients and was found in asymptomatic patients. The presence of SARS-CoV-2 in the middle ear may have implications for ear surgery and can pose a risk of infection for operating room staff. It may also directly affect the audio-vestibular system.

SELEÇÃO DE REFERÊNCIAS