Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Contemp Dent Pract ; 14(1): 9-13, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23579885

RESUMO

AIM: This study evaluates bond strength between dentin and composite using adhesives with different solvents to dry and wet dentin. MATERIALS AND METHODS: Ninety bovine incisors were used; the vestibular surfaces were worn by the exposure of an area with a diameter of 4 mm of dentin. The specimens were divided into 6 groups, according to the type of adhesive used and hydratation stals: Group SB-wet: Single Bond 2 in wet dentin, Group SBdry: Single Bond 2 in dry dentin, Group SL-wet: Solobond M in wet dentin, Group SL-dry: Solobond M in dentin dry. Group XPwet: XP Bond in wet dentin, Group XP-dry: XP Bond in dentin dry. They were cut to obtain specimens in the shape of stick with 1 × 1 mm and subjected to microtensile test in universal testing machine with a cross speed of 1mm/min. The data were analyzed with ANOVA and Tukey's tests (5%). RESULTS: ANOVA showed significant differences for surface treatment and interaction, but no difference was found for adhesive factor. The Tukey's test showed that the samples with wet dentin shown higher values of bond strength. CONCLUSION: The adhesive did not influence in the bond strength. The groups with wet dentin showed higher values of bond strength than groups with dry dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Solventes/química , Condicionamento Ácido do Dente/métodos , Adesividade , Animais , Bovinos , Resinas Compostas/química , Lâmpadas de Polimerização Dentária/classificação , Cimentos Dentários/química , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Dessecação , Teste de Materiais , Ácidos Fosfóricos/química , Polimerização , Distribuição Aleatória , Camada de Esfregaço , Estresse Mecânico , Temperatura , Fatores de Tempo , Água/química
2.
J Contemp Dent Pract ; 14(1): 14-20, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23579886

RESUMO

AIM: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. MATERIALS AND METHODS: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm(2). The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). RESULTS AND CONCLUSION: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. CLINICAL SIGNIFICANCE: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.


Assuntos
Colagem Dentária , Preparo da Cavidade Dentária/instrumentação , Adesivos Dentinários/química , Dentina/ultraestrutura , Diamante/química , Lasers de Estado Sólido/uso terapêutico , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bovinos , Resinas Compostas/química , Equipamentos Odontológicos de Alta Rotação , Análise do Estresse Dentário/instrumentação , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Cimentos de Resina/química , Camada de Esfregaço , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Ultrassom/instrumentação , Água/química
3.
Arch Oral Biol ; 57(8): 1086-92, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22469391

RESUMO

OBJECTIVES: To determine whether chewing side preference (CSP) is correlated to lateralities (handedness, footedness, eyedness and earedness) in primary, mixed and permanent dentitions. DESIGN: Three-hundred subjects were divided into 3 groups: Group 1--100 children 3-5 years old, primary dentition; Group 2--100 children 6-12 years old, mixed dentition; Group 3--100 subjects 18-47 years old, permanent dentition. CSP was determined using a method developed by Mc Donnell et al. Subjects were given a piece of gum and the position of the chewing gum was recorded 7 times as right or left. Subjects were classified as 'observed preferred chewing side' (OPCS) when they performed 5/7, 6/7 or 7/7 strokes on the same side. OPCS corresponded to the CSP. Laterality tests were performed for handedness, footedness, eyedness and earedness tasks. The Chi-square (χ(2)) and phi correlation (r) tests were used to investigate significant correlations between CSP and sidedness. RESULTS: There was a significant correlation between chewing and earedness (p=0.00), although there was weak positive correlation (r=0.30) for primary dentition. There were significant correlations between chewing and handedness (p=0.02; r=0.25) and chewing and footedness (p=0.02; r=0.26), however, there were weak positive correlations for mixed dentition; there were significant correlations between chewing and handedness (p=0.02; r=0.26); chewing and footedness (p=0.00; r=0.33) and chewing and earedness (p=0.01; r=0.29); however, there were weak positive correlations for permanent dentition. CONCLUSION: It may be concluded that CSP can be significantly correlated with: earedness for primary dentition; handedness and footedness for mixed dentition; handedness, footedness and earedness for permanent dentition, but these are weak positive relationships. Future work on larger samples of left- and right-sided individuals is required to validate the findings.


Assuntos
Lateralidade Funcional/fisiologia , Mastigação/fisiologia , Adolescente , Adulto , Goma de Mascar , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Dentição Mista , Dentição Permanente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dente Decíduo
4.
J Adhes Dent ; 14(1): 69-73, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21935516

RESUMO

PURPOSE: To evaluate the cohesive strength between composite and different light-curing characterizing materials (LCCM), which were prepared using the intrinsic technique. MATERIALS AND METHODS: One hundred composite specimens were made by using a prefabricated Teflon device, and a layer of LCCM was applied at the interface. The specimens were divided into 5 groups (n = 20): group 1 (control), no LCCM was used; group 2: application of White Kolor Plus Pigment (Kerr) LCCM; group 3: White Tetric Color Pigment (Ivoclar/Vivadent) LCCM; group 4: Brown Kolor Plus Pigment (Kerr) LCCM; group 5: Black Tetric Color Pigment (Ivoclar/Vivadent) LCCM. All materials were used according to the manufacturers' instructions. Specimens were submitted to a tensile test in a universal testing machine (EMIC DL-200MF) to evaluate the cohesive strength at the composite interface. Data were subjected to one-way ANOVA and Tukey's test (α = 5%). RESULTS: ANOVA showed a p-value = 0.0001, indicating that there were significant differences among the groups. The mean values in MPa (± standard deviation) obtained for the groups were: G1: 28.5 (± 2.74)a; G2: 23.5 (± 2.47)b; G3: 20.3 (± 2.49)b; G4: 10.5 (± 2.40)c; G5: 9.66 (± 3.06)c. The groups with the same letters presented no significant differences. The control group presented statistically significantly higher cohesive strengths when compared to the other groups. The groups in which Brown Kolor Plus Pigment and Black Tetric Color Pigment LCCM were used showed significantly lower cohesive strengths when compared to the groups in which White Kolor Plus Pigment and White Tetric Color Pigment LCMM were used. CONCLUSION: The use of LCCM produced with the intrinsic technique reduced the cohesive strength of composite.


Assuntos
Corantes/química , Resinas Compostas/química , Materiais Dentários/química , Bis-Fenol A-Glicidil Metacrilato/química , Análise do Estresse Dentário/instrumentação , Humanos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
5.
J Adhes Dent ; 13(5): 433-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20978642

RESUMO

PURPOSE: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur. MATERIALS AND METHODS: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (α = 0.05). RESULTS: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F. CONCLUSION: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Diamante/química , Preparo do Dente/instrumentação , Resinas Compostas/química , Equipamentos Odontológicos de Alta Rotação , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Camada de Esfregaço , Estresse Mecânico , Ultrassom/instrumentação
6.
J Contemp Dent Pract ; 12(5): 339-42, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22269193

RESUMO

AIM: This study evaluated the prevalence of the chewing side preference (CSP) in the deciduous, mixed and permanent dentitions. MATERIALS AND METHODS: Three-hundred subjects were divided in three groups (n = 100): Group 1 - children with deciduous dentition; group 2-children with mixed dentition; group 3 - subjects with permanent dentition. The CSP was determined using a direct method (visual observation) developed by McDonnell et al. (2004). Descriptive statistic was used to observe the prevalence of CSP. The Pearson's Chi-square was used to investigate signicant associations between gender, presence of CSP and preferred side (right/left). RESULTS AND CONCLUSION: Eighty-seven percent of group 1 had a CSP. Eighty-two percent of group 2 had a CSP. Seventy-six percent of group 3 had a CSP. There was no statistically significant association between presence of CSP and gender in all groups. There was no statistically significant association between preferred side (right/left) and gender in all groups. CLINICAL SIGNIFICANCE: There is a higher prevalence of subjects in deciduous, mixed and permanent dentition that presented chewing side preference. The early diagnosis of the presence of chewing side preference can prevent the unilateral chewing pattern with prophylactic therapy applied to the first teeth (deciduous).


Assuntos
Dentição Mista , Dentição Permanente , Lateralidade Funcional/fisiologia , Mastigação/fisiologia , Dente Decíduo , Adolescente , Adulto , Goma de Mascar , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA