Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 273: 91-98, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30292381

RESUMO

This study aims to develop methods for determination of Ca, K, Mg and Na by laser-induced breakdown spectroscopy (LIBS) and Ca, K, Mg, Na, P, S, Fe and Zn by wavelength dispersive X-ray fluorescence (WDXRF) in pressed pellets bivalve mollusks. LIBS and WDXRF calibration models were built with references values determined by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion. The calibration models for LIBS and WDXRF were obtained from 28 samples (14 for calibration and 14 for validation). It was possible to implement a validation between LIBS and WDXRF methods for elements Ca, K, Mg and Na. The proposed calibration model obtained using LIBS and WDXRF data presented a good correlation with reference values obtained by ICP OES.


Assuntos
Bivalves/química , Metais/análise , Frutos do Mar/análise , Análise Espectral/métodos , Animais , Cálcio/análise , Calibragem , Análise de Alimentos/métodos , Lasers , Espectrometria de Fluorescência/métodos , Raios X
2.
Talanta ; 152: 457-62, 2016 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-26992542

RESUMO

A new method is proposed for the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS), employing direct solid sample analysis (DSS) and internal standardization (IS). Cobalt was used as internal standard to minimize matrix effects during Ni determinations, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9937. The performance of the method was checked by analysis of six plant certified reference materials, and the results for Mo and Ni were in agreement with the certified values (95% confidence level, t-test). Analysis was made of different types of plant materials used as renewable sources of energy, including sugarcane leaves, banana tree fiber, soybean straw, coffee pods, orange bagasse, peanut hulls, and sugarcane bagasse. The concentrations found for Mo and Ni ranged from 0.08 to 0.63 ng mg(-1) and from 0.41 to 6.92 ng mg(-1), respectively. Precision (RSD) varied from 2.1% to 11% for Mo and from 3.7% to 10% for Ni. Limits of quantification of 0.055 and 0.074 ng were obtained for Mo and Ni, respectively.


Assuntos
Grafite/química , Molibdênio/análise , Níquel/análise , Plantas/química , Espectrofotometria Atômica/normas , Calibragem , Cobalto/análise , Temperatura Alta , Folhas de Planta/química , Padrões de Referência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...