Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Endocrinol ; 176(6): 779-790, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28348071

RESUMO

BACKGROUND: Arthropathy is a prevalent and invalidating complication of acromegaly with a characteristic radiographic phenotype. We aimed to further characterize cartilage and bone abnormalities associated with acromegalic arthropathy using magnetic resonance imaging (MRI). METHODS: Twenty-six patients (23% women, mean age 56.8 ± 13.4 years), with active (n = 10) and controlled acromegaly (n = 16) underwent a 3.0 T MRI of the right knee. Osteophytes, cartilage defects, bone marrow lesions and subchondral cysts were assessed by the Knee Osteoarthritis Scoring System (KOSS) method. Cartilage thickness and cartilage T2 relaxation times, in which higher values reflect increased water content and/or structural changes, were measured. Twenty-five controls (52% women, mean age: 59.6 ± 8.0 years) with primary knee OA were included for comparison. RESULTS: Both in active and controlled acromegaly, structural OA defects were highly prevalent, with thickest cartilage and highest cartilage T2 relaxation times in the active patients. When compared to primary OA subjects, patients with acromegaly seem to have less cysts (12% vs 48%, P = 0.001) and bone marrow lesions (15% vs 80%, P = 0.006), but comparable prevalence of osteophytosis and cartilage defects. Patients with acromegaly had 31% thicker total joint cartilage (P < 0.001) with higher cartilage T2 relaxation times at all measured sites than primary OA subjects (P < 0.01). CONCLUSIONS: Patients with active acromegaly have a high prevalence of structural OA abnormalities in combination with thick joint cartilage. In addition, T2 relaxation times of cartilage are high in active patients, indicating unhealthy cartilage with increased water content, which is (partially) reversible by adequate treatment. Patients with acromegaly have a different distribution of structural OA abnormalities visualized by MRI than primary OA subjects, especially of cartilage defects.


Assuntos
Acromegalia/fisiopatologia , Artropatias/etiologia , Articulação do Joelho/diagnóstico por imagem , Acromegalia/patologia , Acromegalia/terapia , Adulto , Idoso , Cistos Ósseos/diagnóstico por imagem , Cistos Ósseos/epidemiologia , Cistos Ósseos/etiologia , Cistos Ósseos/prevenção & controle , Doenças da Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/epidemiologia , Doenças da Medula Óssea/etiologia , Doenças da Medula Óssea/prevenção & controle , Cartilagem/diagnóstico por imagem , Cartilagem/patologia , Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/epidemiologia , Doenças das Cartilagens/etiologia , Doenças das Cartilagens/prevenção & controle , Estudos Transversais , Feminino , Seguimentos , Humanos , Artropatias/diagnóstico por imagem , Artropatias/epidemiologia , Artropatias/prevenção & controle , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Osteoartrite/diagnóstico por imagem , Osteoartrite/patologia , Projetos Piloto , Prevalência , Indução de Remissão , Índice de Gravidade de Doença
2.
Eur Radiol ; 22(9): 1946-54, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22538627

RESUMO

OBJECTIVE: To quantify radiation exposure and mortality risk from computed tomography (CT) and positron emission tomography (PET) imaging with (18)F-fluorodeoxyglucose ((18)F-FDG) in patients with malignant lymphoma (Hodgkin's disease [HD] or non-Hodgkin's lymphoma [NHL]). METHODS: First, organ doses were assessed for a typical diagnostic work-up in children with HD and adults with NHL. Subsequently, life tables were constructed for assessment of radiation risks, also taking into account the disease-related mortality. RESULTS: In children with HD, cumulative effective dose from medical imaging ranged from 66 mSv (newborn) to 113 mSv (15 years old). In adults with NHL the cumulative effective dose from medical imaging was 97 mSv. Average fractions of radiation-induced deaths for children with HD [without correction for disease-related mortality in brackets] were 0.4% [0.6%] for boys and 0.7% [1.1%] for girls, and for adults with NHL 0.07% [0.28%] for men and 0.09% [0.37%] for women. CONCLUSION: Taking into account the disease-related reduction in life expectancy of patients with malignant lymphoma results in a higher overall mortality but substantial lower incidence of radiation induced deaths. The modest radiation risk that results from imaging with CT and (18)F-FDG PET can be considered as justified, but imaging should be performed with care, especially in children.


Assuntos
Linfoma/diagnóstico , Linfoma/mortalidade , Tomografia por Emissão de Pósitrons/mortalidade , Modelos de Riscos Proporcionais , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/mortalidade , Adolescente , Adulto , Distribuição por Idade , Idoso , Criança , Pré-Escolar , Feminino , Doença de Hodgkin/diagnóstico , Doença de Hodgkin/mortalidade , Humanos , Incidência , Lactente , Recém-Nascido , Expectativa de Vida , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Doses de Radiação , Lesões por Radiação/mortalidade , Medição de Risco , Análise de Sobrevida , Taxa de Sobrevida , Adulto Jovem
3.
Magn Reson Med ; 68(6): 1836-45, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22362637

RESUMO

Spatio-temporal magnetic field changes in the brain caused by breathing or body movements can lead to image artifacts. This is especially a problem in T(2)(*)-weighted sequences. With the acquisition of an extra echo (navigator), it is possible to measure the magnetic field change induced frequency offset for a given slice during image acquisition. However, substantial local variation across a slice can occur. This work describes an extension of the conventional navigator technique that improves the estimation of the magnetic field distribution in the brain during strong field fluctuations. This is done using the combination of signals from multiple coil elements, the coil sensitivity profiles, and frequency encoding: termed sensitivity-encoded navigator echoes. In vivo validation was performed in subjects who performed normal breathing, nose touching, and deep breathing during scanning. The sensitivity-encoded navigator technique leads to an error reduction in estimating the field distribution in the brain of 73% ± 16% compared with 56% ± 14% for conventional estimation. Image quality can be improved via incorporating this navigator information appropriately into the image reconstruction. When the sensitivity-encoded navigator technique was applied to a T(2)(*)-weighted sequence at 7 T, a ghosting reduction of 47% ± 13% was measured during nose touching experiments compared with no correction.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Campos Magnéticos , Dinâmica não Linear , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Proc Inst Mech Eng H ; 223(7): 813-22, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19908420

RESUMO

In shoulder arthroplasty, malpositioning of prostheses often leads to reduced postoperative range of motion (ROM) and complications such as impingement, loosening, and dislocation. Furthermore, the risk of impingement complications increases when reverse total prostheses are used. For this purpose a pre-operative planning system was developed that enables surgeons to perform a virtual shoulder replacement procedure. The present authors' pre-operative planning system simulates patient-specific bone-determined ROM meant to reduce the risk of impingement complications and to improve the ROM of patients undergoing shoulder replacement surgery. This paper describes a validation experiment with the purpose of ratifying the clinical applicability and usefulness of the ROM simulation module for shoulder replacement surgery. The experiment was performed on cadaveric shoulders. A data connection was set up between the software environment and an existing intra-operative guidance system to track the relative positions of the bones. This allowed the patient-specific surface models to be visualized within the software for the position and alignment of the tracked bones. For both shoulders, ROM measurements were recorded and tagged with relevant information such as the type of prosthesis and the type of movement that was performed. The observed ROM and occurrences of impingement were compared with the simulated equivalents. The median deviation between observed impingement angles and simulated impingement angles was -0.30 degrees with an interquartile range of 5.20 degrees (from -3.40 degrees to 1.80 degrees). It was concluded that the ROM simulator is sufficiently accurate to fulfil its role as a supportive instrument for orthopaedic surgeons during shoulder replacement surgery.


Assuntos
Prótese Articular/efeitos adversos , Modelos Biológicos , Implantação de Prótese/métodos , Síndrome de Colisão do Ombro/etiologia , Síndrome de Colisão do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Simulação por Computador , Análise de Elementos Finitos , Humanos , Movimento (Física) , Cuidados Pré-Operatórios/métodos , Prognóstico , Implantação de Prótese/efeitos adversos , Síndrome de Colisão do Ombro/prevenção & controle , Resultado do Tratamento
5.
Phys Med Biol ; 54(10): 3141-59, 2009 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-19420423

RESUMO

Computed tomography (CT) dosimetry should be adapted to the rapid developments in CT technology. Recently a 160 mm wide, 320 detector row, cone beam CT scanner that challenges the existing Computed Tomography Dose Index (CTDI) dosimetry paradigm was introduced. The purpose of this study was to assess dosimetric characteristics of this cone beam scanner, to study the appropriateness of existing CT dose metrics and to suggest a pragmatic approach for CT dosimetry for cone beam scanners. Dose measurements with a small Farmer-type ionization chamber and with 100 mm and 300 mm long pencil ionization chambers were performed free in air to characterize the cone beam. According to the most common dose metric in CT, namely CTDI, measurements were also performed in 150 mm and 350 mm long CT head and CT body dose phantoms with 100 mm and 300 mm long pencil ionization chambers, respectively. To explore effects that cannot be measured with ionization chambers, Monte Carlo (MC) simulations of the dose distribution in 150 mm, 350 mm and 700 mm long CT head and CT body phantoms were performed. To overcome inconsistencies in the definition of CTDI100 for the 160 mm wide cone beam CT scanner, doses were also expressed as the average absorbed dose within the pencil chamber (D100). Measurements free in air revealed excellent correspondence between CTDI300air and D100air, while CTDI100air substantially underestimates CTDI300air. Results of measurements in CT dose phantoms and corresponding MC simulations at centre and peripheral positions were weighted and revealed good agreement between CTDI300w, D100w and CTDI600w, while CTDI100w substantially underestimates CTDI300w. D100w provides a pragmatic metric for characterizing the dose of the 160 mm wide cone beam CT scanner. This quantity can be measured with the widely available 100 mm pencil ionization chamber within 150 mm long CT dose phantoms. CTDI300w measured in 350 mm long CT dose phantoms serves as an appropriate standard of reference for characterizing the dose of this CT scanner. A CT dose descriptor that is based on an integration length smaller than the actual beam width is preferably expressed as an (average) dose, such as D100 for the 160 mm wide cone beam CT scanner, and not as CTDI100.


Assuntos
Carga Corporal (Radioterapia) , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Radiometria/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Brain ; 131(Pt 12): 3277-85, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19022861

RESUMO

Atrophy is regarded a sensitive marker of neurodegenerative pathology. In addition to confirming the well-known presence of decreased global grey matter and hippocampal volumes in Alzheimer's disease, this study investigated whether deep grey matter structure also suffer degeneration in Alzheimer's disease, and whether such degeneration is associated with cognitive deterioration. In this cross-sectional correlation study, two groups were compared on volumes of seven subcortical regions: 70 memory complainers (MCs) and 69 subjects diagnosed with probable Alzheimer's disease. Using 3T 3D T1 MR images, volumes of nucleus accumbens, amygdala, caudate nucleus, hippocampus, pallidum, putamen and thalamus were automatically calculated by the FMRIB's Integrated Registration and Segmentation Tool (FIRST)--algorithm FMRIB's Software Library (FSL). Subsequently, the volumes of the different regions were correlated with cognitive test results. In addition to finding the expected association between hippocampal atrophy and cognitive decline in Alzheimer's disease, volumes of putamen and thalamus were significantly reduced in patients diagnosed with probable Alzheimer's disease. We also found that the decrease in volume correlated linearly with impaired global cognitive performance. These findings strongly suggest that, beside neo-cortical atrophy, deep grey matter structures in Alzheimer's disease suffer atrophy as well and that degenerative processes in the putamen and thalamus, like the hippocampus, may contribute to cognitive decline in Alzheimer's disease.


Assuntos
Doença de Alzheimer/patologia , Putamen/patologia , Tálamo/patologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/psicologia , Atrofia/patologia , Atrofia/psicologia , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/patologia , Estudos Transversais , Feminino , Hipocampo/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos
7.
J Biomech ; 41(1): 155-64, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17706656

RESUMO

Image-based Roentgen stereophotogrammetric analysis (IBRSA) integrates 2D-3D image registration and conventional RSA. Instead of radiopaque RSA bone markers, IBRSA uses 3D CT data, from which digitally reconstructed radiographs (DRRs) are generated. Using 2D-3D image registration, the 3D pose of the CT is iteratively adjusted such that the generated DRRs resemble the 2D RSA images as closely as possible, according to an image matching metric. Effectively, by registering all 2D follow-up moments to the same 3D CT, the CT volume functions as common ground. In two experiments, using RSA and using a micromanipulator as gold standard, IBRSA has been validated on cadaveric and sawbone scapula radiographs, and good matching results have been achieved. The accuracy was: |mu |< 0.083 mm for translations and |mu| < 0.023 degrees for rotations. The precision sigma in x-, y-, and z-direction was 0.090, 0.077, and 0.220 mm for translations and 0.155 degrees , 0.243 degrees , and 0.074 degrees for rotations. Our results show that the accuracy and precision of in vitro IBRSA, performed under ideal laboratory conditions, are lower than in vitro standard RSA but higher than in vivo standard RSA. Because IBRSA does not require radiopaque markers, it adds functionality to the RSA method by opening new directions and possibilities for research, such as dynamic analyses using fluoroscopy on subjects without markers and computer navigation applications.


Assuntos
Imageamento Tridimensional/métodos , Fotogrametria/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Fenômenos Biomecânicos/métodos , Humanos , Reprodutibilidade dos Testes , Escápula/anatomia & histologia , Escápula/diagnóstico por imagem , Técnica de Subtração
8.
Comput Biol Med ; 35(4): 329-46, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15749093

RESUMO

This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours reduce the amount of user interaction.1 This method solves the contour-to-contour correspondence problem and can capture extrema of objects in a more flexible way than manual segmentation of a stack of 2D images. The resulting 3D model is guaranteed to be free of geometric and topological errors. We show that manual segmentation using connected orthogonal contours has great advantages over conventional manual segmentation. Furthermore, the method provides effective feedback and control for creating an initial model for, and control and steering of, (semi-)automatic segmentation methods.


Assuntos
Algoritmos , Imageamento Tridimensional , Reconhecimento Automatizado de Padrão/métodos , Inteligência Artificial , Neoplasias Encefálicas/patologia , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética , Modelos Biológicos , Mioma/patologia , Bexiga Urinária/patologia , Neoplasias Uterinas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...