Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 45(7): 2305-8, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17507524

RESUMO

A two-step real-time PCR assay targeting all six capsulation loci of Haemophilus influenzae (i.e., serotypes a to f) was developed and compared with a previously published qualitative PCR assay by using 131 H. influenzae clinical isolates. There was a 98.5% concordance between the two tests. The sensitivity of detection of capsular type-specific reference strains of H. influenzae a to c (10(1) CFU/PCR) was higher than that for type e (10(3) CFU/PCR) and types d and f (10(4) CFU/PCR), and a broader dynamic range was obtained (5 to 8 log(10) units). No cross-reaction was observed with bacteria commonly isolated from the respiratory tract. We showed that both PCR assays are more reliable than slide agglutination serotyping. The real-time PCR-based assay seems to be an alternative of choice for the epidemiological follow-up of H. influenzae invasive infections.


Assuntos
Cápsulas Bacterianas/genética , Haemophilus influenzae/classificação , Haemophilus influenzae/genética , Reação em Cadeia da Polimerase/métodos , Sorotipagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pré-Escolar , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
2.
FEMS Immunol Med Microbiol ; 48(2): 183-91, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17064275

RESUMO

A major pitfall in most published genomic amplification methods for the detection and identification of human pathogens is that they do not include an internal amplification control in order to achieve an acceptable level of confidence for the absence of false-negative results. By applying composite primer technology, a single multiple internal amplification control DNA molecule was constructed to detect and quantify the hepatitis B virus, human polyomavirus, Epstein-Barr virus, Toxoplasma gondii and cytomegalovirus using real-time PCR. The multiple internal amplification control contains all forward and reverse primer binding regions targeted in the five distinct duplex PCRs, but with a unique probe hybridization site. Multiple internal amplification control detection sensitivity, assessed by Probit analysis, was 58 copies per PCR, associated with an extremely wide dynamic range (8 log(10) units). Moreover, in testing 614 patient samples, PCR inhibition occurred at a frequency of 0-8.8%. Similar multiple internal amplification controls for quantitative PCR-based assays could be designed to accommodate any infectious profiles in a particular institution as they are easy to make and inexpensive.


Assuntos
Sistemas Computacionais , Primers do DNA , DNA Viral/análise , Reação em Cadeia da Polimerase/métodos , Animais , Citomegalovirus/genética , Infecções por Citomegalovirus/virologia , DNA Viral/genética , Infecções por Vírus Epstein-Barr/virologia , Reações Falso-Negativas , Hepatite B/virologia , Vírus da Hepatite B/genética , Herpesvirus Humano 4/genética , Humanos , Vírus JC/genética , Infecções por Polyomavirus/virologia , Toxoplasma/genética , Toxoplasmose/parasitologia
3.
J Mol Diagn ; 6(2): 108-14, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15096566

RESUMO

In a recent study, Candida species in clinical blood samples were detected using a real-time PCR-based method (Maaroufi et al, J Clin Microbiol 2003, 41:3293-3298). For the present study, we evaluated the efficiency of this method as an adjunct to the BACTEC blood culture system to early detection of positivity and negativity of simulated low candidemias. We first established an in vitro correlation between the inoculum of the most frequently encountered Candida species and the time to positivity of these microorganisms. Then, aliquots from blood culture bottles infected with a final average candidal inoculum of 3.18 colony-forming units (CFU)/culture bottle (range, 1 to 6 CFU) were collected at increasing incubation times, and DNA was extracted and submitted to the TaqMan-based PCR assay. To optimize this assay, we evaluated the effect of adding 0.5% bovine serum albumin (BSA) to DNA extracts and found that it decreased the effects of inhibitors. Using specific probes for the tested Candida species, the PCR assay was positive on blood culture aliquots collected from the BACTEC system after a minimum culture turnaround time (TAT) of 3.11 +/- 1.24 hours. Addition of BSA to PCR reaction mixtures improves the TAT (1.84 +/- 0.41 hours). Hence, the combination of DNA "amplification" in the culture bottles by normal growth with an additional DNA amplification by PCR might be a reliable tool facilitating the early diagnosis of low candidemias.


Assuntos
Sangue/microbiologia , Candida/classificação , Candida/genética , Candidíase/diagnóstico , DNA Fúngico/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Animais , Candida/crescimento & desenvolvimento , Candida albicans/genética , Candida albicans/crescimento & desenvolvimento , Candida albicans/isolamento & purificação , Candidíase/microbiologia , Bovinos , Ensaio de Unidades Formadoras de Colônias , Meios de Cultura , DNA Fúngico/sangue , Humanos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Soroalbumina Bovina/metabolismo
4.
J Clin Microbiol ; 41(7): 3293-8, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12843077

RESUMO

We describe a rapid and reproducible PCR assay for quantitation of the Candida albicans ribosomal DNA (rDNA) in clinical blood samples based on the TaqMan principle (Applied Biosystems), in which a signal is generated by cleavage of a template-specific probe during amplification. We used two fluorogenic probes based on universal, fungus-specific primers, one for the detection of C. albicans species DNA and one for the detection of all Candida genus DNA. C. albicans blastoconidia mixed with whole blood in a titration experiment yielded a linear PCR signal over a range of 3 orders of magnitude. The TaqMan-based PCR assay for C. albicans exhibited a low limit of detection (5 CFU/ml of blood) and an excellent reproducibility (96 to 99%). While the C. albicans species-specific probe had 100% specificity for C. albicans, all Candida genus-specific probes cross-reacted with other organisms likely to coinfect patients with C. albicans infections. On the basis of these data, we determined the C. albicans loads with a species-specific probe from 122 blood samples from 61 hematology or oncology patients with clinically proven or suspected systemic Candida infections. Eleven positive samples exhibited a wide range of C. albicans loads, extending from 5 to 100,475 CFU/ml of blood. The sensitivity and specificity of the present assay were 100 and 97%, respectively, compared with the results of blood culture. These data indicate that the TaqMan-based PCR assay for quantitation of C. albicans with a species-specific probe provides an attractive alternative for the identification and quantitation of C. albicans rDNA in pure cultures and blood samples.


Assuntos
Sangue/microbiologia , Candidíase/microbiologia , Reação em Cadeia da Polimerase/métodos , Taq Polimerase/metabolismo , Candida albicans/classificação , Candida albicans/genética , Candida albicans/crescimento & desenvolvimento , Candida albicans/isolamento & purificação , Candidíase/diagnóstico , DNA Fúngico/análise , DNA Ribossômico/análise , Fungemia/diagnóstico , Fungemia/microbiologia , Humanos , Técnicas de Tipagem Micológica , Reprodutibilidade dos Testes , Especificidade da Espécie , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...