Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Oral Maxillofac Implants ; 32(3): 507­513, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27706265

RESUMO

PURPOSE: The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. MATERIALS AND METHODS: Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). RESULTS: The mean vertical misfit was 5.9 ± 3.6 µm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 µm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 µm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) µm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CONCLUSION: CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

2.
J Craniofac Surg ; 27(1): 238-41, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26674889

RESUMO

This study aims to compare stress transmitted to implants and passive fit of one-piece cast frameworks fabricated with 3 different materials: commercially pure titanium (G1-CP Ti), cobalt-chromium alloy (G2-Co-Cr), and nickel-chromium-titanium alloy (G3-Ni-Cr-Ti). In total, 12 frameworks simulating bars for fixed prosthesis in a model with 5 implants were fabricated. The passive fit of the framework interface was measured using an optical microscope and the stresses transmitted to implants were measured using quantitative photoelastic analysis. Data were statistically analyzed by analysis of variance (ANOVA) and least significant difference (LSD) tests (α = 0.05). Mean and standard deviation values of passive fit and stress over implants are presented, respectively: G1 [472.49 (109.88) µm and 11.38 (9.23) KPa], G2 [584.84 (120.20) µm and 15.83 (9.30) KPa], and G3 [462.70 (179.18) µm and 16.39 (9.51) KPa]. For stress over implants, there were significant differences between G1, G2, and G3 (P = 0.035), being the lowest values for the G1. There were no significant differences for passive fit between G1 and G3 (P = 0.844), but both were statistically different from G2 (P = 0.028 and P = 0.035, respectively), which showed the worse results. It may be concluded that the stress over implants was affected by the tested materials. The CP Ti presented the best values for the evaluated items.


Assuntos
Ligas Dentárias/química , Implantes Dentários , Materiais Dentários/química , Prótese Dentária Fixada por Implante , Ligas/química , Ligas de Cromo/química , Revestimento para Fundição Odontológica/química , Técnica de Fundição Odontológica , Adaptação Marginal Dentária , Humanos , Teste de Materiais , Microscopia de Polarização , Distribuição Aleatória , Estresse Mecânico , Propriedades de Superfície , Titânio/química
3.
Braz Dent J ; 26(3): 277-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26200153

RESUMO

The objective of this research was to evaluate the passivity by measuring the passive fit and strain development of frameworks screwed on abutments, made by CAD/CAM technology, and to compare these parts with samples manufactured by conventional casting. Using CAD/CAM technology, four samples were made from zirconia (Zircad) and four samples were manufactured from cobalt-chrome (CoCrcad). The control groups were four specimens of cobalt-chrome, made by one-piece casting (CoCrci), with a total of 12 frameworks. To evaluate the passive fit, the vertical misfit at the abutment-framework interface was measured with scanning electron microscopy (250×) when only one screw was tightened. The mean strain in these frameworks was analyzed by photoelasticity test. A significant difference in the passive fit was observed between the control and sample groups. CoCrcad exhibited the best value of passive fit (48.76±13.45 µm) and CoCrci the worst (187.55±103.63 µm); Zircad presented an intermediate value (103.81±43.15 µm). When compared to the other groups, CoCrci showed the highest average stress around the implants (17.19±7.22 kPa). It was concluded that CAD/CAM-fabricated frameworks exhibited better passivity compared with conventionally fabricated frameworks. CAD/CAM-fabricated Co-Cr frameworks may exhibit better passive fit compared with CAD/CAM-fabricated zirconia frameworks. Even so, similar levels of stress were achieved for CAD/CAM-fabricated frameworks.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Desenho de Prótese , Dente Suporte , Microscopia Eletrônica de Varredura
4.
J Prosthet Dent ; 113(1): 22-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25277028

RESUMO

STATEMENT OF PROBLEM: Relatively little information is available on the accuracy of the abutment-implant interface in computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated zirconia and cobalt-chromium frameworks. PURPOSE: The purpose of this study was to compare the fit accuracy of CAD/CAM-fabricated zirconia and cobalt-chromium frameworks and conventionally fabricated cobalt-chromium frameworks. MATERIAL AND METHODS: Four groups of 3-unit, implant-supported, screw-retained frameworks were fabricated to fit an in vitro model with 3 implants. Eight frameworks were fabricated with the CAD/CAM system: 4 in zirconia and 4 in cobalt-chromium. Another 8 were cast in cobalt-chromium with conventional casting, including 4 with premachined abutments and 4 with castable abutments. The vertical misfit at the implant-framework interface was measured with scanning electron microscopy when only 1 screw was tightened and when all screws were tightened. Data were analyzed with the Kruskal-Wallis and Mann-Whitney tests (α=.05). RESULTS: The mean vertical misfit values when all screws were tightened was 5.9 ±3.6 µm for CAD/CAM-fabricated zirconia, 1.2 ±2.2 µm for CAD/CAM-fabricated cobalt-chromium frameworks, 11.8 ±9.8 µm for conventionally fabricated cobalt-chromium frameworks with premachined abutments, and 12.9 ±11.0 µm for the conventionally fabricated frameworks with castable abutments; the Mann-Whitney test found significant differences (P<.05) among all frameworks, except between the conventionally fabricated frameworks (P=.619). No significant differences were found among the groups for passive fit gap measurements (P>.05). CONCLUSIONS: When all of the screws were tightened, the CAD/CAM frameworks exhibited better fit accuracy compared with the conventionally fabricated frameworks. High levels of passive fit were achieved for the evaluated techniques.


Assuntos
Ligas de Cromo/química , Desenho Assistido por Computador , Adaptação Marginal Dentária , Materiais Dentários/química , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Zircônio/química , Cerâmica/química , Dente Suporte , Técnica de Fundição Odontológica , Projeto do Implante Dentário-Pivô , Técnica de Moldagem Odontológica , Planejamento de Dentadura , Retenção de Dentadura/instrumentação , Dureza , Temperatura Alta , Humanos , Microscopia Eletrônica de Varredura , Estresse Mecânico , Propriedades de Superfície , Ítrio/química
5.
J Craniofac Surg ; 25(6): 2062-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25329843

RESUMO

This study aims to investigate a possible correlation between vertical misfits and the stresses transmitted to implants from one-piece casted frameworks fabricated with 3 different materials: commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy. Twelve frameworks simulating screw-retained prosthesis were fabricated from a master cast with 5 implants. Each framework was screwed (20 Ncm) over a metal cast and the vertical mesial and distal misfits were measured using an optical microscope. The stresses transmitted to the implants were measured in a third model by a quantitative photoelastic analysis. Stress and vertical misfit data were statistically analyzed by ANOVA and least significant difference tests and the correlation tests were performed using Pearson Correlation Test (α = 0.05). Mean and standard deviation values of vertical misfit and stress over implants are presented, respectively: commercially pure titanium (29.09 ± 13.24 µm and 11.38 ± 9.23 kPa), cobalt chromium alloy (27.05 ± 10.30 µm and 15.83 ± 9.30 kPa), nickel chromium titanium alloy (24.95 ± 11.14 µm and 16.39 ± 9.51 kPa). There were no significant differences for vertical misfit (P = 0.285). Regarding the stress analysis, there were significant differences between commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy (P = 0.035), with the lowest values for the commercially pure titanium. It may be concluded that stress over implants was affected by different procedures and materials for framework production.


Assuntos
Mandíbula/anatomia & histologia , Desenho de Prótese/métodos , Análise de Variância , Fenômenos Biomecânicos , Ligas de Cromo/química , Cobalto/química , Dente Suporte , Ligas Dentárias/química , Técnica de Fundição Odontológica , Prótese Dentária Fixada por Implante , Elasticidade , Humanos , Mandíbula/fisiologia , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...