Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int J Mol Sci ; 22(17)2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-34502178

RESUMO

Dysplasia and intramucosal esophageal squamous cell carcinoma (ESCC) frequently go unnoticed with white-light endoscopy and, therefore, progress to invasive tumors. If suitable targets are available, fluorescence molecular endoscopy might be promising to improve early detection. Microarray expression data of patient-derived normal esophagus (n = 120) and ESCC samples (n = 118) were analyzed by functional genomic mRNA (FGmRNA) profiling to predict target upregulation on protein levels. The predicted top 60 upregulated genes were prioritized based on literature and immunohistochemistry (IHC) validation to select the most promising targets for fluorescent imaging. By IHC, GLUT1 showed significantly higher expression in ESCC tissue (30 patients) compared to the normal esophagus adjacent to the tumor (27 patients) (p < 0.001). Ex vivo imaging of GLUT1 with the 2-DG 800CW tracer showed that the mean fluorescence intensity in ESCC (n = 17) and high-grade dysplasia (HGD, n = 13) is higher (p < 0.05) compared to that in low-grade dysplasia (LGD) (n = 7) and to the normal esophagus adjacent to the tumor (n = 5). The sensitivity and specificity of 2-DG 800CW to detect HGD and ESCC is 80% and 83%, respectively (ROC = 0.85). We identified and validated GLUT1 as a promising molecular imaging target and demonstrated that fluorescent imaging after topical application of 2-DG 800CW can differentiate HGD and ESCC from LGD and normal esophagus.


Assuntos
Endoscopia/métodos , Carcinoma de Células Escamosas do Esôfago/diagnóstico por imagem , Regulação Neoplásica da Expressão Gênica , Transportador de Glucose Tipo 1/genética , Proteínas de Neoplasias/genética , Diagnóstico Precoce , Carcinoma de Células Escamosas do Esôfago/genética , Carcinoma de Células Escamosas do Esôfago/metabolismo , Esôfago/diagnóstico por imagem , Esôfago/metabolismo , Fluorescência , Perfilação da Expressão Gênica , Humanos , Imuno-Histoquímica , Análise de Sequência com Séries de Oligonucleotídeos , RNA Mensageiro , Sensibilidade e Especificidade
2.
Theranostics ; 10(12): 5357-5367, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32373217

RESUMO

Fluorescence molecular endoscopy (FME) is an emerging technique in the field of gastroenterology that holds potential to improve diagnosis and guide therapy, by serving as a 'red-flag' endoscopic imaging technique. Here, we investigated the safety, feasibility and optimal method of administration of EMI-137, targeting c-Met, during FME in Barrett's Esophagus (BE) and report several outcome parameters for early phase FME studies. Methods: FME was performed in 15 Barrett's neoplasia patients. EMI-137 was administered to three cohorts of five patients: 0.13 mg/kg intravenously (IV); 0.09 mg/kg IV or topically at a dose of 200 µg/cm BE (n=1) or 100 µg/cm BE (n=4). Fluorescence was visualized in vivo, quantified in vivo using multi-diameter single-fiber reflectance, single-fiber fluorescence (MDSFR/SFF) spectroscopy and correlated to histopathology and immunohistochemistry. EMI-137 localization was assessed using fluorescence microscopy. Results: FME using different IV and topical doses of EMI-137 appeared to be safe and correctly identified 16/18 lesions, although modest target-to-background ratios were observed (median range of 1.12-1.50). C-Met overexpression varied between lesions, while physiological expression in the stomach-type epithelium was observed. Microscopically, EMI-137 accumulated around the neoplastic cell membranes. We identified several outcome parameters important for the validation of EMI-137 for FME: 1) the optimal administration route; 2) optimal dose and safety; 3) in vivo FME contrast; 4) quantification of intrinsic fluorescence; 5) ex vivo correlation of fluorescence, histopathology and target expression; and 6) microscopic tracer distribution. Conclusions: C-Met targeted FME using EMI-137 may not be the ideal combination to improve BE surveillance endoscopies, however the identified outcome parameters may serve as a valuable guidance for designing and performing future early phase clinical FME studies, independent of which fluorescent tracer is investigated.


Assuntos
Esôfago de Barrett/metabolismo , Neoplasias Esofágicas/metabolismo , Proteínas Proto-Oncogênicas c-met/metabolismo , Idoso , Biópsia/métodos , Neoplasias Esofágicas/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Proteínas Proto-Oncogênicas c-met/genética
3.
J Nucl Med ; 61(10): 1435-1441, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32198312

RESUMO

Fluorescence molecular endoscopy (FME) is an emerging technique that has the potential to improve the 22% colorectal polyp detection miss-rate. We determined the optimal dose-to-imaging interval and safety of FME using EMI-137, a c-Met-targeted fluorescent peptide, in a population at high risk for colorectal cancer. Methods: We performed in vivo FME and quantification of fluorescence by multidiameter single-fiber reflectance/single-fiber fluorescence spectroscopy in 15 patients with a dysplastic colorectal adenoma. EMI-137 was intravenously administered (0.13 mg/kg) at a 1-, 2- or 3-h dose-to-imaging interval (n = 3 patients per cohort). Two cohorts were expanded to 6 patients on the basis of target-to-background ratios. Fluorescence was correlated to histopathology and c-Met expression. EMI-137 binding specificity was assessed by fluorescence microscopy and in vitro experiments. Results: FME using EMI-137 appeared to be safe and well tolerated. All dose-to-imaging intervals showed significantly higher fluorescence in the colorectal lesions than in surrounding tissue, with a target-to-background ratio of 1.53, 1.66, and 1.74 for the 1-, 2-, and 3-h cohorts, respectively, and a mean intrinsic fluorescence of 0.035 vs. 0.023 mm-1 (P < 0.0003), 0.034 vs. 0.021 mm-1 (P < 0.0001), and 0.033 vs. 0.019 mm-1 (P < 0.0001), respectively. Fluorescence correlated with histopathology on a macroscopic and microscopic level, with significant c-Met overexpression in dysplastic mucosa. In vitro, a dose-dependent specific binding was confirmed. Conclusion: FME using EMI-137 appeared to be safe and feasible within a 1- to 3-h dose-to-imaging interval. No clinically significant differences were observed among the cohorts, although a 1-h dose-to-imaging interval was preferred from a clinical perspective. Future studies will investigate EMI-137 for improved colorectal polyp detection during screening colonoscopies.


Assuntos
Adenoma/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Proteínas Proto-Oncogênicas c-met/metabolismo , Espectrometria de Fluorescência/métodos , Idoso , Pólipos do Colo/patologia , Neoplasias Colorretais/patologia , Feminino , Células HT29 , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Nucl Med ; 61(5): 655-661, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31628218

RESUMO

Negative circumferential resection margins (CRM) are the cornerstone for the curative treatment of locally advanced rectal cancer (LARC). However, in up to 18.6% of patients, tumor-positive resection margins are detected on histopathology. In this proof-of-concept study, we investigated the feasibility of optical molecular imaging as a tool for evaluating the CRM directly after surgical resection to improve tumor-negative CRM rates. Methods: LARC patients treated with neoadjuvant chemoradiotherapy received an intravenous bolus injection of 4.5 mg of bevacizumab-800CW, a fluorescent tracer targeting vascular endothelial growth factor A, 2-3 d before surgery (ClinicalTrials.gov identifier: NCT01972373). First, for evaluation of the CRM status, back-table fluorescence-guided imaging (FGI) of the fresh surgical resection specimens (n = 8) was performed. These results were correlated with histopathology results. Second, for determination of the sensitivity and specificity of bevacizumab-800CW for tumor detection, a mean fluorescence intensity cutoff value was determined from the formalin-fixed tissue slices (n = 42; 17 patients). Local bevacizumab-800CW accumulation was evaluated by fluorescence microscopy. Results: Back-table FGI correctly identified a tumor-positive CRM by high fluorescence intensities in 1 of 2 patients (50%) with a tumor-positive CRM. For the other patient, low fluorescence intensities were shown, although (sub)millimeter tumor deposits were present less than 1 mm from the CRM. FGI correctly identified 5 of 6 tumor-negative CRM (83%). The 1 patient with false-positive findings had a marginal negative CRM of only 1.4 mm. Receiver operating characteristic curve analysis of the fluorescence intensities of formalin-fixed tissue slices yielded an optimal mean fluorescence intensity cutoff value for tumor detection of 5,775 (sensitivity of 96.19% and specificity of 80.39%). Bevacizumab-800CW enabled a clear differentiation between tumor and normal tissue up to a microscopic level, with a tumor-to-background ratio of 4.7 ± 2.5 (mean ± SD). Conclusion: In this proof-of-concept study, we showed the potential of back-table FGI for evaluating the CRM status in LARC patients. Optimization of this technique with adaptation of standard operating procedures could change perioperative decision making with regard to extending resections or applying intraoperative radiation therapy in the case of positive CRM.


Assuntos
Bevacizumab , Margens de Excisão , Imagem Óptica , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Cirurgia Assistida por Computador , Adulto , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/cirurgia , Resultado do Tratamento
6.
Eur J Surg Oncol ; 44(11): 1708-1713, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30005963

RESUMO

PURPOSE: Around 15%-30% of patients receiving breast-conserving surgery (BCS) for invasive breast carcinoma or ductal carcinoma in situ (DCIS) need a reoperation due to tumor-positive margins at final histopathology. Currently available intraoperative surgical margin assessment modalities all have specific limitations. Therefore, we aimed to assess the feasibility and accuracy of micro-computed tomography (micro-CT) as a novel method for intraoperative margin assessment in BCS. METHODS: Lumpectomy specimens from 30 consecutive patients diagnosed with invasive breast cancer or DCIS were imaged using a micro-CT. Margin status was assessed on micro-CT images by two investigators who were blinded to the final histopathological margin status. The micro-CT margin status was compared with the histopathological margin status. RESULTS: The margin status could be assessed by micro-CT in 29 out of 30 patients. Of these, nine patients had a positive tumor margin and 20 a negative tumor margin at final histopathology. Margin status evaluation by micro-CT took always less than 15 min. The margin status in 25 patients was correctly predicted by micro-CT. There were four false-negative predictions. The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of micro-CT in margin status prediction were 86%, 56%, 100%, 100% and 83%, respectively. With micro-CT, the positive margin rate could potentially have been reduced from 31% to 14%. CONCLUSIONS: Whole lumpectomy specimen micro-CT scanning is a promising technique for intraoperative margin assessment in BCS. Intraoperative quick feedback on the margin status could potentially lead to a reduction in the number of reoperations.


Assuntos
Carcinoma de Mama in situ/diagnóstico por imagem , Carcinoma de Mama in situ/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Margens de Excisão , Mastectomia Segmentar , Microtomografia por Raio-X , Idoso , Carcinoma de Mama in situ/patologia , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Humanos , Cuidados Intraoperatórios , Pessoa de Meia-Idade , Invasividade Neoplásica , Valor Preditivo dos Testes , Sensibilidade e Especificidade
7.
J Surg Oncol ; 118(2): 332-343, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29938400

RESUMO

Patients with peritoneal carcinomatosis (PC) from colorectal origin may undergo cytoreductive surgery (CRS) with hyperthermic intraperitoneal chemotherapy (HIPEC) as a curative approach. One major prognostic factor that affects survival is completeness of cytoreduction. Molecular Fluorescence Guided Surgery (MFGS) is a novel intraoperative imaging technique that may improve tumor identification in the future, potentially preventing over- and under-treatment in these patients. This narrative review outlines a chronological overview of MFGS development in patients with PC of colorectal origin.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Procedimentos Cirúrgicos de Citorredução/métodos , Imagem Molecular/métodos , Imagem Óptica/métodos , Neoplasias Peritoneais/secundário , Neoplasias Peritoneais/cirurgia , Cirurgia Assistida por Computador/métodos , Neoplasias Colorretais/diagnóstico por imagem , Humanos , Monitorização Intraoperatória/métodos , Invasividade Neoplásica , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/patologia
8.
Lancet Gastroenterol Hepatol ; 1(4): 283-290, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-28404198

RESUMO

BACKGROUND: Optimum cytoreductive surgery combined with hyperthermic intraperitoneal chemotherapy (HIPEC) is essential for the curative treatment of peritoneal carcinomatosis of colorectal origin. At present, surgeons depend on visual inspection and palpation for tumour detection. Improved detection of tumour tissue using molecular fluorescence-guided surgery could not only help attain a complete cytoreduction of metastatic lesions, but might also prevent overtreatment by avoiding resection of benign lesions. METHODS: For this non-randomised, single-centre feasibility study, we enrolled patients with colorectal peritoneal metastases scheduled for cytoreductive surgery and HIPEC. 2 days before surgery, 4·5 mg of the near-infrared fluorescent tracer bevacizumab-IRDye800CW was administered intravenously. The primary objectives were to determine the safety and feasibility of molecular fluorescence-guided surgery using bevacizumab-IRDye800CW. Molecular fluorescence-guided surgery was deemed safe if no allergic or anaphylactic reactions were recorded and no serious adverse events were attributed to bevacizumab-IRDye800CW. The technique was deemed feasible if bevacizumab-IRDye800CW enabled detection of fluorescence signals intraoperatively. Secondary objectives were correlation of fluorescence with histopathology by back-table imaging of the fresh surgical specimen and semi-quantitative ex-vivo analyses of formalin-fixed paraffin embedded (FFPE) tissue on all peritoneal lesions. Additionally, VEGF-α staining and fluorescence microscopy was done. This study is registered with the Netherlands Trial Registry, number NTR4632. FINDINGS: Between July 3, 2014, and March 2, 2015, seven patients were enrolled in the study. One patient developed an abdominal sepsis 5 days postoperatively and another died from an asystole 4 days postoperatively, most probably due to a cardiovascular thromboembolic event. However, both serious adverse events were attributed to the surgical cytoreductive surgery and HIPEC procedure. No serious adverse events related to bevacizumab-IRDye800CW occurred in any of the patients. Intraoperatively, fluorescence was seen in all patients. In two patients, additional tumour tissue was detected by molecular fluorescence-guided surgery that was initially missed by the surgeons. During back-table imaging of fresh surgical specimens, a total of 80 areas were imaged, marked, and analysed. All of the 29 non-fluorescent areas were found to contain only benign tissue, whereas tumour tissue was detected in 27 of 51 fluorescent areas (53%). Ex-vivo semi-quantification of 79 FFPE peritoneal lesions showed a tumour-to-normal ratio of 6·92 (SD 2·47). INTERPRETATION: Molecular fluorescence-guided surgery using the near-infrared fluorescent tracer bevacizumab-IRDye800CW is safe and feasible. This technique might be of added value for the treatment of patients with colorectal peritoneal metastases through improved patient selection and optimisation of cytoreductive surgery. A subsequent multicentre phase 2 trial is needed to make a definitive assessment of the diagnostic accuracy and the effect on clinical decision making of molecular fluorescence-guided surgery. FUNDING: FP-7 Framework Programme BetaCure and SurgVision BV.


Assuntos
Carcinoma/secundário , Carcinoma/cirurgia , Neoplasias Colorretais/patologia , Procedimentos Cirúrgicos de Citorredução/métodos , Imagem Óptica , Neoplasias Peritoneais/secundário , Neoplasias Peritoneais/cirurgia , Adulto , Idoso , Antineoplásicos/uso terapêutico , Bevacizumab , Carcinoma/diagnóstico por imagem , Carcinoma/terapia , Quimioterapia do Câncer por Perfusão Regional/métodos , Terapia Combinada , Estudos de Viabilidade , Feminino , Corantes Fluorescentes , Humanos , Hipertermia Induzida/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...