Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 255
Filtrar
1.
Pediatr Cardiol ; 28(6): 477-81, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17763891

RESUMO

The construction of efficient designs with minimal energy losses is especially important for cavopulmonary connections. The science of computational fluid dynamics has been increasingly used to study the hemodynamic performance of surgical operations. Three-dimensional computer models can be accurately constructed of typical cavopulmonary connections used in clinical practice based on anatomic data derived from magnetic resonance scans, angiocardiograms, and echocardiograms. Using these methods, the hydraulic performance of the hemi-Fontan, bidirectional Glenn, and a variety of types of completion Fontan operations can be evaluated and compared. This methodology has resulted in improved understanding and design of these surgical operations.


Assuntos
Simulação por Computador , Técnica de Fontan/métodos , Artéria Pulmonar/cirurgia , Veia Cava Inferior/cirurgia , Hemodinâmica , Humanos , Imageamento Tridimensional , Modelos Cardiovasculares , Circulação Pulmonar/fisiologia
2.
Stat Med ; 26(28): 5189-202, 2007 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-17407095

RESUMO

We demonstrate the use of dynamic longitudinal models to investigate error management in cardiac surgery. Case study data were collected from a multicentre study of the neonatal arterial switch operation (ASO). Information on two types of negative events, or 'errors', observed during surgery, major and minor events, was extracted from case studies. Each event was judged to be recovered from (compensated) or not (uncompensated). The aim of the study was to model compensation given the occurrence of past events within a case. Two models were developed, one for the probability of compensating for a major event and a second model for the probability of compensating for a minor event. Analyses based on dynamic logistic regression models suggest that the total number of preceding minor events, irrespective of compensation status, is negatively related with the ability to compensate for major events. The alternative use of random effects models is investigated for comparison purposes.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Erros Médicos/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Transposição dos Grandes Vasos/cirurgia , Feminino , Humanos , Recém-Nascido , Comunicação Interdisciplinar , Modelos Logísticos , Masculino , Modelos Estatísticos , Avaliação de Resultados em Cuidados de Saúde/métodos , Equipe de Assistência ao Paciente/normas , Probabilidade , Reino Unido
3.
J Appl Biomater Biomech ; 5(1): 11-22, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-20799192

RESUMO

The surgical reconstruction of the aortic arch is necessary in pediatric patients suffering from different types of congenital heart malformations, in particular, coarctation of the aorta. Among the reconstruction techniques used in surgical practice end-to-end anastomosis (E/E), Gore-tex graft interposition (GGI) and Gore-tex patch graft aortoplasty (GPGA) are compared in this study with a control model, employing a computational fluid-structure-interaction scheme. This study analyzes the impact of introducing synthetic materials on aortic hemodynamics and wall mechanics. Three-dimensional (3D) geometries of a porcine aortic arch were derived from magnetic resonance imaging (MRI) images. Inlet conditions were derived from MRI velocimetry. A multiscale approach was used for the imposition of outlet conditions, wherein a lumped parameter net provided an active afterload. Evidence was found that ring-like repairs increased blood velocity, whereas GPGA limited it. Vortex presence was greater and longer lasting in GGI. The highest power losses corresponded to GPGA. GGI had an intermediate effect, while E/E dissipated only slightly more than the control case. Wall stresses peak in a longitudinal strip on the subject's left side of the vessel, particularly in the frontal area. There was a concentration of stress at the suture lines. All surgical techniques performed equally well in restoring physiological pressures.

4.
Ergonomics ; 49(5-6): 567-88, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16717010

RESUMO

Patient safety will benefit from an approach to human error that examines systemic causes, rather than blames individuals. This study describes a direct observation methodology, based on a threat and error model, prospectively to identify types and sources of systems failures in paediatric cardiac surgery. Of substantive interest were the range, frequency and types of failures that could be identified and whether minor failures could accumulate to form more serious events, as has been the case in other industries. Check lists, notes and video recordings were employed to observe 24 successful operations. A total of 366 failures were recorded. Coordination and communication problems, equipment problems, a relaxed safety culture, patient-related problems and perfusion-related problems were most frequent, with a smaller number of skill, knowledge and decision-making failures. Longer and more risky operations were likely to generate a greater number of minor failures than shorter and lower risk operations, and in seven higher-risk cases frequently occurring minor failures accumulated to threaten the safety of the patient. Non-technical errors were more prevalent than technical errors and task threats were the most prevalent systemic source of error. Adverse events in surgery are likely to be associated with a number of recurring and prospectively identifiable errors. These may be co-incident and cumulative human errors predisposed by threats embedded in the system, rather than due to individual incompetence or negligence. Prospectively identifying and reducing these recurrent failures would lead to improved surgical standards and enhanced patient safety.


Assuntos
Erros Médicos/prevenção & controle , Salas Cirúrgicas/normas , Pediatria/normas , Gestão da Segurança/métodos , Especialidades Cirúrgicas/normas , Análise de Sistemas , Cirurgia Torácica/normas , Adolescente , Criança , Ergonomia , Humanos , Assistência Perioperatória/efeitos adversos , Assistência Perioperatória/normas , Complicações Pós-Operatórias/prevenção & controle , Medição de Risco , Gestão de Riscos , Análise e Desempenho de Tarefas , Resultado do Tratamento , Reino Unido
5.
Heart ; 92(3): 382-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16118238

RESUMO

OBJECTIVE: To determine the accuracy of prenatal and postnatal echocardiography in delineating the degree of cardiac fusion, intracardiac anatomy (ICA), and ventricular function of 23 sets of conjoined twins with thoracic level fusion presenting to a single centre over a 20 year period. METHODS: 13 thoracopagus, 5 thoraco-omphalopagus, and 5 parapagus pairs presenting to the authors' institution between 1985 and 2004 inclusive were assessed. Echocardiographic data were analysed together with operative intervention and outcome. Twins were classified according to the degree of cardiac fusion: separate hearts and pericardium (group A, n = 5), separate hearts and common pericardium (group B, n = 7), fused atria and separate ventricles (group C, n = 2), and fused atria and ventricles (group D, n = 9). RESULTS: The degree of cardiac fusion was correctly diagnosed in all but one set. ICA was correctly diagnosed in all cases, although the antenatal diagnosis was revised postnatally in three cases. Abnormal ICA was found in one twin only in two group A pairs, one group B pair, and both group C pairs. All group D twins had abnormal anatomy. Ventricular function was good in all twins scanned prenatally, and postnatally function correlated well with clinical condition. Thirteen sets of twins in groups A-C were surgically separated; 16 of 26 survived. None from groups C or D survived. CONCLUSIONS: Prenatal and postnatal echocardiography accurately delineates cardiac fusion, ICA, and ventricular function in the majority of twins with thoracic level fusion. It is integral in assessing feasibility of separation. The outcome in twins with fused hearts remains dismal.


Assuntos
Ecocardiografia/normas , Cardiopatias Congênitas/ultraestrutura , Assistência Perinatal/normas , Gêmeos Unidos , Ultrassonografia Pré-Natal/normas , Disfunção Ventricular Esquerda/diagnóstico por imagem , Feminino , Humanos , Recém-Nascido , Masculino , Sensibilidade e Especificidade , Gêmeos Unidos/cirurgia
6.
J Appl Biomater Biomech ; 3(3): 147-56, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-20799220

RESUMO

Surgical interventions on the arterial wall can produce modifications to its tissue characteristics, and the addition of synthetic materials of different types can have implications on hemodynamics and blood vessel wall behavior. This work studies the midterm effects of end-to-end anastomosis (E/E), Gore-tex graft interposition (GGI) and Gore-tex patch graft aortoplasty (GPGA) in aortic arch reconstruction. The study comprised of two groups of healthy Danish sows. The sows in the first group (short term (ST)) weighed about 40 kg, underwent a surgical operation and were sacrificed on the same day. The sows in the second group (midterm (MT)) weighed 5-10 kg, underwent a surgical operation and were then allowed to grow to a weight of about 30-40 kg, before being sacrificed. One sow in each group was scheduled for E/E and one sow for GGI. One sow in ST and two sows in MT received GPGA. The overall average wall thickness was 1.93 mm. Relaxation constant values were significantly higher for ST (5.221 +/- 1.832 sec) than for MT (2.184 +/- 1.216 sec). GPGA showed a greater impact on relaxation than other procedures, enhancing the viscous character. The working-point Young's modulus (Epw ) was not significantly different in ST and MT. Circumferential samples had different Epw (0.419 +/- 0.77 MPa) from longitudinal samples (0.902 +/- 0.378 MPa). There also appeared to be a significant difference between samples cut longitudinally on the left and the right sides of the wall. The overall average Epw value was 0.6609 +/- 0.3641 MPa.

7.
Arch Dis Child ; 89(9): 856-9, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15321866

RESUMO

AIMS: To evaluate the pitfalls of incident reporting in a complex medical environment. METHODS: Retrospective review of 211 incident reports in a paediatric cardiac intensive care unit (CICU). Two adverse event reporting databases were compared: database A (DA), the hospital's official reporting system, is non-anonymous and reports are predominantly made by nurses; database B (DB) is anonymous and reports are submitted by a CICU consultant who collects data from daily ward rounds. Both databases classify adverse events into incident type (drug errors, ventilation, cannulae/indwelling lines, chest drains, blood transfusion, equipment, operational) and severity (0 = no, 1 = minor, 2 = major, 3 = life threatening consequences). RESULTS: Between 1 April 1998 and 31 July 2001 there were 211 adverse events involving 178 patients (11.87%), among 1500 patients admitted to CICU. A total of 112 incidents were reported in DA, 143 in DB, and 44 in both. In isolation, both databases gave an unrepresentative picture of the true frequency and severity of adverse events. Under-reporting was especially notable for less severe events (grade 0, or near misses) CONCLUSION: Incident reporting in the medical field is highly variable, and is heavily influenced by profession of the reporters as well as anonymity. When adverse event reporting is based predominantly on the observations of a single professional group, the data are grossly inaccurate.


Assuntos
Cuidados Críticos/estatística & dados numéricos , Gestão de Riscos/estatística & dados numéricos , Sistemas de Notificação de Reações Adversas a Medicamentos/normas , Criança , Confidencialidade , Bases de Dados Factuais/normas , Falha de Equipamento , Sistemas de Informação Hospitalar/normas , Humanos , Erros Médicos , Corpo Clínico Hospitalar , Recursos Humanos de Enfermagem Hospitalar , Estudos Retrospectivos , Gestão de Riscos/métodos
8.
Heart ; 90(5): 545-51, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15084554

RESUMO

OBJECTIVE: To delineate predictors of hospital survival in a large series of children with biventricular physiology supported with extracorporeal membrane oxygenation (ECMO) after open heart surgery. RESULTS: 81 children were placed on ECMO after open heart surgery. 58% (47 of 81) were transferred directly from cardiopulmonary bypass to ECMO. Hospital survival was 49% (40 of 81) but there were seven late deaths among these survivors (18%). Factors that improved the odds of survival were initiation of ECMO in theatre (64% survival (30 of 47)) rather than the cardiac intensive care unit (29% survival (10 of 34)) and initiation of ECMO for reactive pulmonary hypertension. Important adverse factors for hospital survival were serious mechanical ECMO circuit problems, renal support, residual lesions, and duration of ECMO. CONCLUSIONS: Hospital survival of children with biventricular physiology who require cardiac ECMO is similar to that found in series that include univentricular hearts, suggesting that successful cardiac ECMO is critically dependent on the identification of hearts with reversible ventricular dysfunction. In our experience of postoperative cardiac ECMO, the higher survival of patients cannulated in the operating room than in the cardiac intensive care unit is due to early effective support preventing prolonged hypoperfusion and the avoidance of a catastrophic cardiac arrest.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Cardiopatias Congênitas/cirurgia , Ponte Cardiopulmonar/métodos , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Mortalidade Hospitalar , Humanos , Lactente , Recém-Nascido , Nefropatias/etiologia , Nefropatias/terapia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Análise de Regressão , Paralisia Respiratória/etiologia , Paralisia Respiratória/terapia , Estudos Retrospectivos , Sepse/etiologia , Análise de Sobrevida , Resultado do Tratamento
9.
Eur J Cardiothorac Surg ; 24(1): 28-36; discussion 36, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12853042

RESUMO

OBJECTIVE: Recurrent pulmonary venous obstruction (PVO) occurs in 0-18% of infants undergoing correction of total anomalous pulmonary venous connection (TAPVC). Limited published data suggest that PVO usually develops within 6 months of primary repair, and that outcomes of reoperations are poor. This study aimed to review our experience of reoperations for PVO post-TAPVC repair and to identify risk factors for adverse outcome. METHODS: Twenty patients underwent reoperation for PVO between 1982 and 2002. Clinical data were reviewed. TAPVC was mostly infracardiac (11 patients). TAPVC was obstructed in nine patients. PVO developed early (<6 months) in seven patients, and late in 13 (>6 months). Time of presentation was unrelated to type of PVO (anastomotic vs. ostial). Repair was accomplished using various techniques (anastomotic enlargement with native atrial tissue, enlargement with pericardium, free or in situ, or other prosthetic material). Follow-up ranged from 1 month to 15 years (average 44 months). RESULTS: Thirteen patients received one reoperation, while seven had multiple reoperations. In 13 patients, PVO was defined as new onset (no obstruction post-TAPVC repair), and in seven patients as residual (minimal obstructive changes post-TAPVC repair that progressed to PVO). Ten patients presented with anastomotic PVO, six with anastomotic and ostial PVO (involving the PVs), three with ostial PVO, and one with coronary sinus-left atrial junction stenosis. Mortality was 25% (5/20). Six of the ten patients with anastomotic PVO underwent one reoperation (2/6 died); the other four developed ostial PVO after reoperation, requiring multiple procedures (2/4 died). Mode of presentation (new onset vs. residual), site of obstruction (anastomotic vs. ostial), preoperative RV pressure (<0.8 vs. >0.8 systemic), number of reoperations (single vs. multiple), residual obstruction (presence or absence), and operative approach (Gore-tex or not) did not seem to affect outcomes. Risk factors for death were early presentation (<6 months) and persistence of pulmonary hypertension after reoperation; early presentation was also a risk factor for multiple reoperations. CONCLUSIONS: Our findings support the conclusion that early presentation and postoperative pulmonary hypertension have the greatest adverse impact on outcome. Of these, failure to achieve a low-pressure pulmonary vascular system seems to be the variable that most strongly prevents survival. In our series, neither ostial PVO nor multiple re-interventions significantly increased surgical risk. The negative impact of postoperative residual obstruction on outcome was not striking. However, an aggressive surgical approach to this disease is still warranted. Although the role of each technique in obtaining long-lasting relief of PVO remains to be established, the use of artificial material seems unwise.


Assuntos
Complicações Pós-Operatórias/cirurgia , Veias Pulmonares/anormalidades , Veias Pulmonares/cirurgia , Pneumopatia Veno-Oclusiva/cirurgia , Implante de Prótese Vascular , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/mortalidade , Lactente , Pericárdio/cirurgia , Complicações Pós-Operatórias/mortalidade , Pneumopatia Veno-Oclusiva/mortalidade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
10.
Circulation ; 107(25): 3204-8, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12821557

RESUMO

BACKGROUND: The pulsatile nature of pulmonary blood flow is important for shear stress-mediated release of endothelium-derived nitric oxide (NO) and lowering pulmonary vascular resistance (PVR) by passive recruitment of capillaries. Normal pulsatile flow is lost or markedly attenuated after Fontan-type operations, but to date, there are no data on basal pulmonary vascular resistance and its responsiveness to exogenous NO at late follow-up in these patients. METHODS AND RESULTS: We measured indexed PVR (PVRI) using Fick principle to calculate pulmonary blood flow, with respiratory mass spectrometry to measure oxygen consumption, in 15 patients (median age, 12 years; range, 7 to 17 years; 12 male, 3 female) at a median of 9 years after a Fontan-type operation (6 atriopulmonary connections, 7 lateral tunnels, 2 extracardiac conduits). The basal PVRI was 2.11+/-0.79 Wood unit (WU) times m2 (mean+/-SD) and showed a significant reduction to 1.61+/-0.48 (P=0.016) after 20 ppm of NO for 10 minutes. The patients with nonpulsatile group in the pulmonary circulation dropped the PVRI from 2.18+/-0.34 to 1.82+/-0.55 (P<0.05) after NO inhalation. CONCLUSIONS: PVR falls with exogenous NO late after Fontan-type operation. These data suggest pulmonary endothelial dysfunction, related in some part to lack of pulsatility in the pulmonary circulation because of altered flow characteristics. Therapeutic strategies to enhance pulmonary endothelial NO release may have a role in these patients.


Assuntos
Endotélio Vascular/fisiologia , Técnica de Fontan , Óxido Nítrico/administração & dosagem , Circulação Pulmonar/fisiologia , Resistência Vascular/fisiologia , Administração por Inalação , Adolescente , Fatores Etários , Angiografia , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Cardíaco , Criança , Endotélio Vascular/efeitos dos fármacos , Feminino , Cardiopatias Congênitas/cirurgia , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Circulação Pulmonar/efeitos dos fármacos , Fluxo Pulsátil/fisiologia , Tempo , Resistência Vascular/efeitos dos fármacos
11.
Eur J Cardiothorac Surg ; 22(6): 885-90, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12467809

RESUMO

OBJECTIVES: A hybrid operation is a joint procedure involving the interventional cardiologist and the cardiac surgeon concomitantly to optimise surgical management. The aim of our study was to demonstrate the conceptual development and the feasibility of a hybrid approach to complex congenital cardiac surgery. METHODS: Descriptive study of two different indications for concomitant intervention by the cardiologist and the cardiac surgeon. Seven patients with complex congenital heart defects requiring high risk operative interventions were included in the study. The indications were: (1) intraoperative stenting of a pulmonary artery stenosis with concomitant additional surgical procedures (n=4). (2) Balloon occlusion of Blalock-Taussig shunts or major aorto-pulmonary collateral artery to control pulmonary blood flow during surgical repair (n=3). RESULTS: All patients had successful hybrid procedures. There were no important complications related to the temporal proximity of the interventional procedure and cardiac surgery, the latter being significantly facilitated by the former. CONCLUSIONS: Intraoperative stenting of pulmonary artery stenosis with additional surgical repair and balloon occlusion on cardiopulmonary bypass can be performed safely and may be complementary in patients with complex lesions by providing a better result in combination than either alone can offer.


Assuntos
Cardiopatias Congênitas/terapia , Adolescente , Adulto , Oclusão com Balão/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar , Cateterismo/métodos , Criança , Pré-Escolar , Terapia Combinada , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Estenose da Valva Pulmonar/terapia , Reoperação/métodos , Stents
12.
Thorac Cardiovasc Surg ; 50(2): 100-1, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11981711

RESUMO

Here, we report on a case of temporary neurological damage following conduit replacement from the right ventricle to pulmonary artery during which vacuum-assisted venous drainage was used. We will discuss the benefits and risks of this technique with potential arterial air embolism despite the use of arterial line filters. We will also make recommendations for avoiding such complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Embolia Aérea/etiologia , Circulação Extracorpórea/efeitos adversos , Cardiopatias Congênitas/cirurgia , Complicações Intraoperatórias/etiologia , Sucção/efeitos adversos , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Falha de Equipamento , Circulação Extracorpórea/instrumentação , Circulação Extracorpórea/métodos , Humanos , Masculino , Reoperação , Sucção/instrumentação , Sucção/métodos , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 21(2): 255-9, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11825732

RESUMO

OBJECTIVE: To determine the incidence of postoperative junctional ectopic tachycardia (JET), we reviewed 343 consecutive patients undergoing surgery between 1997 and 1999. The impact of this arrhythmia on in-hospital morbidity and our protocol for treatment were assessed. METHODS: We reviewed the postoperative course of patients undergoing surgery for ventricular septal defect (VSD; n=161), tetralogy of Fallot (TOF; n=114), atrioventricular septal defect (AVSD; n=58) and common arterial trunk (n=10). All patients with JET received treatment, in a stepwise manner, beginning with surface cooling, continuous intravenous amiodarone, and/or atrial pacing if the haemodynamics proved unstable. A linear regression model assessed the effect of these treatments upon hours of mechanical ventilation, and stay on the cardiac intensive care unit (CICU). RESULTS: Overall mortality was 2.9% (n=10), with three of these patients having JET and TOF. JET occurred in 37 patients (10.8%), most frequently after TOF repair (21.9%), followed by AVSD (10.3%), VSD (3.7%), and with no occurrence after repair of common arterial trunk. Mean ventilation time increased from 83 to 187 h amongst patients without and with JET patients (P<0.0001). Accordingly, CICU stay increased from 107 to 210 h when JET occurred (P<0.0001). Surface cooling was associated with a prolongation of ventilation and CICU stay, by 74 and 81 h, respectively (P<0.02; P<0.02). Amiodarone prolonged ventilation and CICU stay, respectively, by 274 and 275 h (P<0.05; P<0.06). CONCLUSIONS: Postoperative JET adds considerably to morbidity after congenital cardiac surgery, and is particularly frequent after TOF repair. Aggressive treatment with cooling and/or amiodarone is mandatory, but correlates with increased mechanical ventilation time and CICU stay. Better understanding of the mechanism underlying JET is required to achieve prevention, faster arrhythmic conversion, and reduction of associated in-hospital morbidity.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Taquicardia Ectópica de Junção/complicações , Taquicardia Ectópica de Junção/mortalidade , Amiodarona/administração & dosagem , Análise de Variância , Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/mortalidade , Comunicação Interventricular/cirurgia , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Complicações Pós-Operatórias/mortalidade , Período Pós-Operatório , Probabilidade , Prognóstico , Respiração Artificial , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Taquicardia Ectópica de Junção/terapia , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/mortalidade , Tetralogia de Fallot/cirurgia
14.
Qual Health Care ; 10 Suppl 2: ii21-5, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11700375

RESUMO

Investigations of accidents in a number of hazardous domains suggest that a cluster of organisational pathologies-the "vulnerable system syndrome" (VSS)-render some systems more liable to adverse events. This syndrome has three interacting and self-perpetuating elements: blaming front line individuals, denying the existence of systemic error provoking weaknesses, and the blinkered pursuit of productive and financial indicators. VSS is present to some degree in all organisations, and the ability to recognise its symptoms is an essential skill in the progress towards improved patient safety. Two kinds of organisational learning are discussed: "single loop" learning that fuels and sustains VSS and "double loop" learning that is necessary to start breaking free from it.


Assuntos
Prevenção de Acidentes , Administração Hospitalar/normas , Erros Médicos/prevenção & controle , Gestão de Riscos/organização & administração , Humanos , Cultura Organizacional , Gestão da Segurança , Bode Expiatório , Medicina Estatal/organização & administração , Medicina Estatal/normas , Reino Unido
15.
Eur J Cardiothorac Surg ; 20(6): 1252-4, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11717042

RESUMO

We report a rare case of a 2-year-old boy with Down's syndrome, atrioventricular septal defect and so-called 'absent pulmonary valve syndrome'. Diagnostic imaging also revealed the presence of an anomalous high origin of the right coronary artery from the ascending aorta. Surgical repair was successful.


Assuntos
Síndrome de Down/complicações , Comunicação Atrioventricular/complicações , Valva Pulmonar/anormalidades , Pré-Escolar , Humanos , Masculino
16.
Ann Thorac Surg ; 72(4): 1358-61, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11603461

RESUMO

BACKGROUND: In patients who undergo left ventricular retraining, multiple reoperations are often necessary to adjust the pulmonary artery banding. The availability of a percutaneously adjustable band would be very useful. METHODS: Ten lambs (10 to 25 kg) underwent pulmonary artery banding using a new device, 7 by thoracotomy and 3 by thoracoscopy. The possibility of percutaneously adjusting the band was evaluated immediately after operation in 10 animals and at 3 months in 8 animals. RESULTS: One death occurred on the day of the procedure from displacement of the device and another death was from infection. Immediate hemodynamic studies proved the feasibility of increasing right ventricular afterload in a precise and reversible way. After 3 months the band could still be precisely loosened or tightened in all but 1 animal. Autopsy revealed that all the devices were in the correct position and no fibrosis or adhesions were present around the devices, and there was no residual stenosis noted on the pulmonary artery. CONCLUSIONS: This new device may be a valuable alternative to the repeated pulmonary artery banding needed for ventricular preparation.


Assuntos
Cateteres de Demora , Cardiopatias Congênitas/cirurgia , Pulmão/irrigação sanguínea , Nylons , Complicações Pós-Operatórias/cirurgia , Implantação de Prótese , Artéria Pulmonar/cirurgia , Animais , Pressão Sanguínea/fisiologia , Desenho de Prótese , Ovinos , Sístole/fisiologia , Função Ventricular Direita/fisiologia
18.
Ann Thorac Surg ; 72(1): 300-5, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11465216

RESUMO

In this review, we discuss human factors research in cardiac surgery and other medical domains. We describe a systems approach to understanding human factors in cardiac surgery and summarize the lessons that have been learned about critical incident and near-miss reporting in other high technology industries that are pertinent to this field.


Assuntos
Doença Iatrogênica , Complicações Intraoperatórias/etiologia , Transposição dos Grandes Vasos/cirurgia , Falha de Tratamento , Humanos , Doença Iatrogênica/prevenção & controle , Recém-Nascido , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...