Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sportverletz Sportschaden ; 9(3): 84-91, 1995 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-7502218

RESUMO

The study is based on 128 basketball accidents. The following accident types were discovered: ankle sprains 54.7%, handling the ball (saving and catching) 15.6%, knee-joint-distorsions 10.2%, collisions, blows and kicks 11.7%, falls 3.9%, spontaneous damage of muscles and tendons 1.6% and getting hurt because of the equipment in the gym 2.3%. Prophylactic precautions might be physiological or synthetic taping, proprioceptor training and preventive sports medical checkups.


Assuntos
Traumatismos em Atletas/etiologia , Basquetebol/lesões , Traumatismos do Tornozelo/etiologia , Traumatismos do Tornozelo/prevenção & controle , Traumatismos em Atletas/prevenção & controle , Avaliação da Deficiência , Feminino , Traumatismos dos Dedos/etiologia , Traumatismos dos Dedos/prevenção & controle , Humanos , Luxações Articulares/etiologia , Luxações Articulares/prevenção & controle , Traumatismos do Joelho/etiologia , Traumatismos do Joelho/prevenção & controle , Masculino , Fatores de Risco
2.
Int J Sports Med ; 14 Suppl 1: S35-8, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8262706

RESUMO

Stabilizing the balance of the boat is a main task of the rowing motion. This leads to movements which are asymmetrical relative to the boat's plane of symmetry. The three-dimensional motion of the boat should be measured when investigating the elements of keeping the balance. This spatial motion must be described by the three components of the translational velocity and the three components of the angular velocity. The latter values can be measured using gyros. A system was developed which employs these sensors. The system is small and light enough to be used aboard a single scull. Measurements which were obtained using this system conclude the article. They illustrate some factors of importance for the stability of the boat and demonstrate the suitability of the system presented.


Assuntos
Movimento (Física) , Esforço Físico/fisiologia , Equilíbrio Postural , Esportes/fisiologia , Fenômenos Biomecânicos , Humanos , Transdutores
3.
Sportverletz Sportschaden ; 3(2): 53-7, 1989 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-2665159

RESUMO

The quantitative significance of the sensory organs in sport is discussed by means of the visual parameters static and dynamic visual acuity and the equilibrium that is specific for a particular kind of sport. Spectators with normal visual acuity can identify footballs, tennis balls etc. used in game sports, with relative ease, compared with sports equipment used in athletics. However, since moving objects can attain an angular velocity of 400 degrees/s and higher in certain sports, the mean dynamic visual acuity is unable to cope with such speeds, this being only 200 to 230 degrees/s. Dynamic visual acuity can be trained, thus attaining higher levels in game sports. Processes of balance regulation during cycling (or in rhythmical sports gymnastics) are discussed in connection with and subsequent to the problem of the intersensory perception conflict. Finally, the article sums up criteria for the observation of movement and for minimising intersensory perception conflicts.


Assuntos
Equilíbrio Postural , Desempenho Psicomotor , Esportes , Acuidade Visual , Humanos
4.
Dtsch Med Wochenschr ; 112(7): 286, 1987 Feb 13.
Artigo em Alemão | MEDLINE | ID: mdl-3816602
6.
Eur J Clin Pharmacol ; 30(6): 685-9, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3533566

RESUMO

In a double-blind, interindividual comparative study 30 healthy volunteers were randomly allocated to oral treatment with 5 or 10 mg of dihydroergotamine (DHE) or placebo once daily for 16 days. Regional basic venous blood volume (BBV), pressure dependent venous capacitance (CV) of the calf, resting heart rate and blood pressure were determined on Days 1 and 15 of treatment. Plasma concentrations of DHE were monitored on Days 2 and 16. Due to spontaneous vasodilation BBV varied considerably, showing that it is an inappropriate parameter for investigating the venoconstrictor activity of DHE. CV remained unchanged after the first dose of DHE but it had declined significantly on both dosage regimens at the end of the treatment phase. In contrast, the blood concentration profiles of DHE were comparable at the beginning and the end of the trial. The discrepancy can best be explained by the existence of an effect compartment, e.g. smooth vascular musculature, which slowly becomes filled with DHE and/or its active metabolites. The venoconstrictor activity of DHE exhibited a significant dose-response relationship.


Assuntos
Di-Hidroergotamina/farmacologia , Vasoconstrição/efeitos dos fármacos , Administração Oral , Adulto , Volume Sanguíneo/efeitos dos fármacos , Ensaios Clínicos como Assunto , Di-Hidroergotamina/administração & dosagem , Di-Hidroergotamina/metabolismo , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Cinética , Masculino , Distribuição Aleatória , Pressão Venosa/efeitos dos fármacos
8.
Z Kardiol ; 73(5): 333-8, 1984 May.
Artigo em Alemão | MEDLINE | ID: mdl-6485466

RESUMO

Besides examining the properties of the material involved, this investigation assesses the so-called static and dynamic measurement errors of sensors used for air segment plethysmography. The static error which has been found with the new BN sensors amounts to 8% (old models: 31%-44%). The folding of the interior membrane of the sensor resting upon the skin, which increases proportionately to the stiffness of the material, is discussed as a source of error. If a lockable steel wrapping is employed as an exterior cover for the sensors, the static measurement error decreases by 30%-50%. These results suggest a recommendation to use a metal wrapping for the sensors as described above even with routine air segment plethysmographic examinations, and additionally to correct by mathematical means the static measurement error (which has to be determined for each sensor individually). The measurement error of the sensors of the new BN series amounts to less than 5% for a frequency of not more than 0.5 Hz; this means that blood flow values amounting to more than 50 ml/(min X 100 ml) are indicated correctly with respect to the actual frequency. If the usual linen covering is used instead of the steel cover, the linearity of the frequency is only valid up to 0.1 Hz--the corresponding blood flow value being 15 ml/(min X 100 ml).


Assuntos
Hemodinâmica , Pletismografia/instrumentação , Diagnóstico Diferencial , Humanos , Perna (Membro)/irrigação sanguínea , Modelos Cardiovasculares , Reologia
9.
Z Kardiol ; 73(5): 339-45, 1984 May.
Artigo em Alemão | MEDLINE | ID: mdl-6485467

RESUMO

The measurement of tissue volume in the calf area carried out by computer-tomography and planimetry showed a nearly elliptic form, an average bony part of 9.9 ml (9.3%), and an average tissue volume of 97.7 ml (90.7%). When compared with the tissue volume approximation (cylinder formula) the tissue volumes thus specified were too large. The error, depending on the circumference of the calf, was about 5 to 15%. There was a difference of 5% between the venous capacity measured by computer-tomography on the one hand and air segment plethysmography on the other. The reason for this is found in the varying density of veins in the examined area. The application of the sensor on the skin caused an average reduction of 5.4% in total volume and thus in the blood volume of about 59% in the examined area. The pressure-dependent venous capacity was measured with and without application of the sensors on the skin and controlled by computer-tomography. The results showed an average difference of only 2.1%. Thus it is obviously unimportant for the results of the investigation presented, if the venous capacity is measured on the basis of the reduced total volume caused by the application of the sensors on the skin. With regard to the computer-tomographical and planimetrical control and the error of measurement discussed, the results suggest a sufficient precision of the venoextensiometry measuring the pressure-dependent venous capacity.


Assuntos
Hemodinâmica , Pletismografia/métodos , Tomografia Computadorizada por Raios X , Volume Sanguíneo , Humanos , Perna (Membro)/irrigação sanguínea , Reologia
10.
Int J Sports Med ; 3(3): 174-6, 1982 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6982247

RESUMO

The role of the vestibular system during physical exercise has only been rarely analyzed by scientific investigations. An investigation was carried out with the purpose of obtaining information on vestibular regulation in rowers. The process of maintaining balance in the boat and the limiting factors were examined. Twenty beginners and 20 well-trained rowers participated in standardized vestibular tests in the laboratory as well as in the boat (single) on the water. The results suggest that several mechanisms in the physiologic field (torque of the body) are affected by training. The well-trained oarsmen showed a significant minor nystagmus frequency, and this criterion for general vestibular regulation also showed a relationship with the specific ability for maintaining balance in the boat.


Assuntos
Vestíbulo do Labirinto/fisiologia , Eletronistagmografia , Humanos , Equilíbrio Postural , Medicina Esportiva
11.
Z Kardiol ; 67(4): 289-98, 1978 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-654412

RESUMO

In 23 patients suffering from intermittent claudication due to chronic occlusions of the femoral artery proved on angiography, a double-blind study was performed to compare the effects of treatment with oxyfedrine and interval-training and of interval-training alone. The claudication distance, physical work capacity and physical work intensity were measured on the treadmill before, during and after 10-weeks training period in each case. After training, the walking ability improved in both groups, however, quantitatively being more pronounced in the oxyfedrine group. In the placebo group, the increase in physical work intensity was mainly caused by the improvement of walking ability in patients with higher levels of performance at the beginning of the training. In the oxyfedrine group, on the other hand, a continuous and regular increase in physical work intensity was found at all levels of performance and during the whole training period. For the differences found, blood supply lowering mechanisms after physical training and improvement of collaterals after combination oxyfedrine and physical training are discussed. The possibility of additive action of the pharmacologic treatment and physical training are pointed out.


Assuntos
Terapia por Exercício , Claudicação Intermitente/tratamento farmacológico , Oxifedrina/uso terapêutico , Propiofenonas/uso terapêutico , Idoso , Circulação Colateral , Método Duplo-Cego , Humanos , Claudicação Intermitente/terapia , Masculino , Pessoa de Meia-Idade , Placebos , Fatores de Tempo
15.
MMW Munch Med Wochenschr ; 119(40): 1301-4, 1977 Oct 07.
Artigo em Alemão | MEDLINE | ID: mdl-412061

RESUMO

During the course of a double-blind study in 30 orthostatically unstable adolescent subjects, the effect of oral dihydroergotamine (DHE) on the orthostatic circulatory regulation was examined. During standardized orthostatic strain the volume of blood sinking into the two legs is statistically significantly reduced to 125 +/- 61 ml (29%) under the influence of DHE after standing for only 11 sec. Furthermore, there is a significant reduction of the maximal arterial influx into the lower extremities as well as the resting heart rate and the maximal heart rate during orthostatic strain. No significant changes could be detected in the placebo group. Consequently, DHE is suitalbe for the treatment of the these disturbances of orthostatic circulatory regulation due to increased elasticity of the capacitive vessels in the lower extremities.


Assuntos
Di-Hidroergotamina/farmacologia , Hipotensão Ortostática/fisiopatologia , Fluxo Sanguíneo Regional/efeitos dos fármacos , Administração Oral , Adolescente , Adulto , Ensaios Clínicos como Assunto , Di-Hidroergotamina/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Perna (Membro)/irrigação sanguínea , Masculino
18.
Z Kardiol ; 65(5): 478-89, 1976 May.
Artigo em Alemão | MEDLINE | ID: mdl-936722

RESUMO

In eight persons central hemodynamic parameters as well as peripheral circulatory parameters were measured before and during spinal anaesthesia (L3/4; 5 ml Carbostesin mit Adrenalin): heart rate, arterial pressure, central venous pressure, peripheral venous pressure, peripheral blood flow, venous capacity (Cv 70) using a venous pressure of 70 mm Hg (lethysmographic method) as well as intravascular basic volume. Intravascular basic volume and the venous capacity are representing total intravascular volume; changes in this parameter- in correlation to a well defind intravenous pressure - give information on the distensibility of capacitance vessels. During spinal anesthesia an increase in resting blood flow of the calf as well as in total blood volume was noted as a result of a decreasing total peripheral resistance and changes in blood distribution (shunting, nutritive blood supply). Intravascular total blood volume in the calf increased from 9.7 +/- 1.0 ml/100 ml to 10.9 +/- 1.1 ml/100 ml, being caused mainly by changes in basic volume not so much by changes in venous capacity. These results may be interpreted as an increase in distensibility of the low pressure vessels during spinal anesthesia.


Assuntos
Raquianestesia , Hemodinâmica , Adulto , Pressão Sanguínea , Volume Sanguíneo , Pressão Venosa Central , Feminino , Frequência Cardíaca , Humanos , Masculino , Matemática , Pressão Venosa
19.
Cardiology ; 61 suppl 1: 78-90, 1976.
Artigo em Alemão | MEDLINE | ID: mdl-975151

RESUMO

A series of well-known orthostatic tests were performed in order to substantiate complaints of patients in respect to blood volume drawn into both legs as an early orthostatic regulation. It could be shown that the blood volume pooled in the legs changed highly from test to test up to 250%. There was evidence that with increasing stagnating blood volume, there was not only an increase of arterial blood influx to the lower extremities, but a maximum of heart rate as well as reaction to the orthostatic stress. Under standardized conditions, 14 orthostatically unstable subjects have been tested. 57% of them collapsed in the course of the tests. Following a 14-day administration of dihydroergotamine, the percentage of collapsing subjects was reduced to 7%. At the same time there was a decrease in the following simultaneously measured circulatory parameters as heart rate, mean arterial pressure and heart volume, especially in cases where these changes of parameters were significantly high at the beginning of the experiment. Suggestions are given when it is necessary to detect disturbance of early orthostatic regulation in patients subjected to orthostatic tests. The importance of the dicroty quotient of the arterial pulse as a diagnostic criterion is emphasized.


Assuntos
Pressão Sanguínea , Pressão Sanguínea/efeitos dos fármacos , Volume Sanguíneo/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Di-Hidroergotamina/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Homeostase , Humanos , Perna (Membro)/irrigação sanguínea , Postura , Pulso Arterial/efeitos dos fármacos
20.
Med Klin ; 70(50): 2031-3, 1975 Dec 12.
Artigo em Alemão | MEDLINE | ID: mdl-1207637

RESUMO

Forearm and digital blood flow were measured by venous occlusion plethysmography in 7 patients with terminal renal failure before and 8 days after surgically created arterio-venous end-to-end fistula similar to the method of Brescia and Cimino. The forearm blood flow rose significantly from 3.30 +/- 1.75 to 6.98 +/- 4.74 ml/min - 100 ml. Total forearm blood flow increased from 32.9 +/- 16.8 ml/min to 69.8 +/- 45.8 ml/min. Digital blood flow was not significantly altered. The relatively low fistula flow was due to the early postoperative measurement since it increased later.


Assuntos
Derivação Arteriovenosa Cirúrgica , Dedos/irrigação sanguínea , Antebraço/irrigação sanguínea , Adulto , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Feminino , Humanos , Isquemia/prevenção & controle , Masculino , Pletismografia , Cuidados Pós-Operatórios , Diálise Renal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...