Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(16): 162501, 2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37925694

RESUMO

Neutrinoless double beta decay (0νßß) is a yet unobserved nuclear process that would demonstrate Lepton number violation, a clear evidence of beyond standard model physics. The process two neutrino double beta decay (2νßß) is allowed by the standard model and has been measured in numerous experiments. In this Letter, we report a measurement of 2νßß decay half-life of ^{100}Mo to the ground state of ^{100}Ru of [7.07±0.02(stat)±0.11(syst)]×10^{18} yr by the CUPID-Mo experiment. With a relative precision of ±1.6% this is the most precise measurement to date of a 2νßß decay rate in ^{100}Mo. In addition, we constrain higher-order corrections to the spectral shape, which provides complementary nuclear structure information. We report a novel measurement of the shape factor ξ_{3,1}=0.45±0.03(stat)±0.05(syst) based on a constraint on the ratio of higher-order terms from theory, which can be reliably calculated. This is compared to theoretical predictions for different nuclear models. We also extract the first value for the effective axial vector coupling constant obtained from a spectral shape study of 2νßß decay.

2.
Phys Rev Lett ; 130(21): 211802, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37295094

RESUMO

Coherent elastic neutrino-nucleus scattering and low-mass dark matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO_{4} cryogenic detector from the NUCLEUS experiment exposed to a ^{252}Cf source placed in a compact moderator. We identify the expected peak structure from the single-γ de-excitation of ^{183}W with 3σ and its origin by neutron capture with 6σ significance. This result demonstrates a new method for precise, in situ, and nonintrusive calibration of low-threshold experiments.


Assuntos
Núcleo Celular , Nêutrons , Califórnio , Método de Monte Carlo
3.
Phys Rev Lett ; 129(23): 232502, 2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36563213

RESUMO

Neutrinoless double beta decay (0νßß) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g_{A}/g_{V}), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νßß experiments. In this Letter, we present measurements performed on a high-resolution LiInSe_{2} bolometer in a "source=detector" configuration to measure the spectral shape of the fourfold forbidden ß decay of ^{115}In. The value of g_{A}/g_{V} is determined by comparing the spectral shape of theoretical predictions to the experimental ß spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g_{A}/g_{V} at >5σ with a model-dependent quenching factor of 0.655±0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the ^{115}In half-life to be [5.18±0.06(stat)_{-0.015}^{+0.005}(sys)]×10^{14} yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-ß decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νßß sensitivity calculations.

4.
Phys Rev Lett ; 126(18): 181802, 2021 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-34018798

RESUMO

The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a demonstrator for CUPID, the next-generation ton-scale bolometric 0νßß experiment. It consists of a 4.2 kg array of 20 enriched Li_{2}^{100}MoO_{4} scintillating bolometers to search for the lepton-number-violating process of 0νßß decay in ^{100}Mo. With more than one year of operation (^{100}Mo exposure of 1.17 kg×yr for physics data), no event in the region of interest and, hence, no evidence for 0νßß is observed. We report a new limit on the half-life of 0νßß decay in ^{100}Mo of T_{1/2}>1.5×10^{24} yr at 90% C.I. The limit corresponds to an effective Majorana neutrino mass ⟨m_{ßß}⟩<(0.31-0.54) eV, dependent on the nuclear matrix element in the light Majorana neutrino exchange interpretation.

5.
Appl Radiat Isot ; 68(7-8): 1459-66; discussion 1466, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20106670

RESUMO

Sources of enriched (240)Pu were prepared by vacuum evaporation on quartz substrates. High-resolution alpha-particle spectrometry of (240)Pu was performed with high statistical accuracy using silicon detectors and with low statistical accuracy using a bolometer. The alpha-particle emission probabilities of six transitions were derived from the spectra and compared with literature values. Additionally, some alpha-particle emission probabilities were derived from gamma-ray intensity measurements with a high-purity germanium detector. The alpha-particle emission probabilities of the three main transitions at 5168.1, 5123.6 and 5021.2 keV were derived from seven aggregate spectra analysed with five different fit functions and the results were compatible with evaluated data. Two additional weak peaks at 4863.5 and 4492.0 keV were fitted separately, using the exponential of a polynomial function to represent the underlying tailing of the larger peaks. The peak at 4655 keV could not be detected by alpha-particle spectrometry, while gamma-ray spectrometry confirms that its intensity is much lower than expected from literature.

6.
Appl Radiat Isot ; 64(10-11): 1281-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16618545

RESUMO

Applications such as environment monitoring implying alpha emitters activity measurement associated with isotope identification, require high-energy resolution detectors. Conventional silicon detectors are inexpensive therefore widely used, although intrinsically limited in energy resolution. Thermal detection principle of cryogenic detectors introduces a breakthrough in alpha particle measurement. For the first time, spectra with 5.5 keV FWHM energy resolution have been obtained for several external alpha emitting sources using a copper-germanium bolometer specially developed for alpha spectrometry.


Assuntos
Partículas alfa , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , Transdutores , Temperatura Baixa , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espectral/métodos
7.
Appl Radiat Isot ; 60(2-4): 363-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14987669

RESUMO

Cryogenic detectors offer remarkably better energy resolutions than those achievable with conventional semiconductor or scintillation detectors. With the additional asset of a detection efficiency close to unity for low-energy X-ray photons and electrons, these detectors have the potential to perform X-ray, gamma and electron spectroscopy of a hitherto unknown quality, in particular at low energies. Two types of cryogenic detectors are described and the results of prototype detectors are presented.


Assuntos
Calorimetria/instrumentação , Análise de Falha de Equipamento , Congelamento , Radioisótopos/análise , Radiometria/instrumentação , Análise Espectral/instrumentação , Termografia/instrumentação , Transdutores , Calorimetria/métodos , Desenho de Equipamento , Estudos de Viabilidade , Projetos Piloto , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria gama/instrumentação , Espectrometria gama/métodos , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/métodos , Análise Espectral/métodos , Integração de Sistemas , Termografia/métodos
8.
Appl Radiat Isot ; 56(1-2): 245-51, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11839023

RESUMO

Microcalorimeters (or bolometers) operated at temperatures below 100 mK allow individual counting of photons and electrons with a very low energy detection threshold. The physics is based on the pulse temperature increase of the target (or absorber) of the detector due to the complete absorption of both electrons and photons. Since this target can be constructed with a perfect 4-pi geometry, a bolometer offers potentially a new method for absolute activity measurements of radionuclides emitting low-energy radiation. In this paper we present our first results of a feasibility study of activity standardization of a 55Fe solution with a prototype 4-pi bolometer.

9.
Appl Radiat Isot ; 52(3): 403-6, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10724382

RESUMO

Due to the intrinsic performances of cryogenic detectors such as energy resolution, LPRI has decided to use these devices to improve the quality of the radioactive measurements usually obtained with classical semiconductor detectors. A bolometer with a 10 microg tin absorber has been developed at IAS (Institut d'Astrophysique Spatiale) and has been tested in the cryogenic installation of LPRI; an energy resolution (full width half maximum, FWHM) of 39 eV has been obtained on the Kalpha line of Mn. Besides these good spectrometry results, an absolute activity measurement using bolometers is proposed by adapting an absorber geometry for 4 pi counting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...