Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
PLoS One ; 12(2): e0172635, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28235055

RESUMO

PURPOSE: Current standards and guidelines aimed at preventing retinal phototoxicity during intentional exposures do not specifically evaluate the contribution of endogenous photosensitizers. However, certain retinal diseases are characterized by abnormal accumulations of potential photosensitizers such as lipofuscin bisretinoids in the retinal pigment epithelium (RPE). We sought to determine these contributions by a numerical assessment of in-vivo photo-oxidative stress during irradiation of RPE lipofuscin. METHODS: Based on the literature, we calculated the retinal exposure levels, optical filtering of incident radiation by the ocular lens, media, photoreceptors, and RPE melanin, light absorption by lipofuscin, and photochemical effects in the RPE in two situations: exposure to short-wavelength (λ = 488 nm) fundus autofluorescence (SW-AF) excitation light and exposure to indirect (diffuse) sunlight. RESULTS: In healthy persons at age 20, 40, and 60, respectively, the rate of oxygen photoconsumption by lipofuscin increases by 1.3, 1.7, and 2.4 fold during SW-AF-imaging as compared to diffuse sunlight. In patients with STGD1 below the age of 30, this rate was 3.3-fold higher compared to age-matched controls during either sunlight or SW-AF imaging. CONCLUSIONS: Our results suggest that the RPE of patients with STGD1 is generally at increased risk of photo-oxidative stress, while exposure during SW-AF-imaging amplifies this risk. These theoretical results have not yet been verified with in-vivo data due to a lack of sufficiently sensitive in-vivo measurement techniques.


Assuntos
Lipofuscina/metabolismo , Degeneração Macular/congênito , Imagem Óptica/efeitos adversos , Células Fotorreceptoras de Vertebrados/efeitos da radiação , Fármacos Fotossensibilizantes/metabolismo , Epitélio Pigmentado da Retina/efeitos da radiação , Adulto , Feminino , Angiofluoresceinografia/efeitos adversos , Fundo de Olho , Humanos , Degeneração Macular/diagnóstico por imagem , Degeneração Macular/metabolismo , Degeneração Macular/patologia , Masculino , Melaninas/metabolismo , Pessoa de Meia-Idade , Estresse Oxidativo/efeitos da radiação , Processos Fotoquímicos , Células Fotorreceptoras de Vertebrados/metabolismo , Células Fotorreceptoras de Vertebrados/patologia , Epitélio Pigmentado da Retina/metabolismo , Epitélio Pigmentado da Retina/patologia , Doença de Stargardt , Luz Solar , Tomografia de Coerência Óptica/efeitos adversos
2.
Med Biol Eng Comput ; 51(1-2): 103-12, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23065628

RESUMO

Measuring functional activity in brain in connection with neural stimulation faces technological challenges. Our goal is to evaluate, in relative terms, the real-time variations of local cerebral blood flow in rat brain, with a convenient spatial resolution. The use of laser Doppler flowmetry (LDF) probes is a promising approach but commercially available LDF probes are still too large (450 µm) to allow insertion in brain tissue without causing damage in an extension that may negatively impact local measurements. The self-mixing technique coupled to LDF is herein proposed to overcome limitations of the minimal diameter of the probe imposed by non-self-mixing probes (commercial available probes). Our Monte Carlo simulations show that laser photons have a mean penetration depth of 0.15 mm, on the rat brain with the 785 nm laser light microprobe. Moreover, three self-mixing signal processing methods are tested: counting method, autocorrelation method, power spectrum method. The perfusion signal computed shows a good linearity with the scatterers velocity, for the three methods (a determination coefficient close to one is obtained), for the in vitro measurements. Furthermore, we believe that these indicators can be used to monitor local blood flow changes in the rat brain.


Assuntos
Encéfalo/irrigação sanguínea , Fluxometria por Laser-Doppler , Microcirculação/fisiologia , Microvasos/fisiologia , Monitorização Fisiológica , Animais , Masculino , Método de Monte Carlo , Perfusão , Imagens de Fantasmas , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
3.
Phys Med Biol ; 54(13): 3955-77, 2009 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-19494425

RESUMO

We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is needed, especially when the two folds act differently, e.g. in the case of tumour growth. Recently, with our novel depth-kymographic laryngoscope, we obtained calibrated data about the horizontal and vertical positions of the visible surface of the vibrating vocal folds. In order to find relations with physical parameters such as elasticity and damping constants, we numerically simulated the horizontal and vertical positions and movements of the human vocal folds while vibrating and investigated the effect of varying several parameters on the characteristics of the phonation: the masses and their dimensions, the respective forces and pressures, and the details of the vocal tract compartments. Direct one-to-one comparison with measured 3D positions presents-for the first time-a direct means of validation of these calculations. This may start a new field in vocal folds research.


Assuntos
Quimografia/métodos , Modelos Biológicos , Medida da Produção da Fala/métodos , Prega Vocal/fisiologia , Idoso , Simulação por Computador , Humanos , Masculino , Movimento/fisiologia , Vibração
4.
Microcirculation ; 16(7): 559-71, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19488922

RESUMO

OBJECTIVE: Clinical acceptance of laser-Doppler perfusion monitoring (LDPM) of microcirculation suffers from lack of quantitatively reliable signal data, due to varying tissue constitution, temperature, hydration, etc. In this article, we show that a novel approach using physiological models for response upon provocations provides quantitatively and clinically relevant time constants. METHODS: We investigated this for two provocation protocols: postocclusive reactive hyperemia (PORH) and iontophoresis shots, measured with LDPM on extremities. PORH experiments were performed on patients with peripheral arterial occlusive disease (PAOD) or diabetes mellitus (DM), and on healthy controls. Iontophoresis experiments were performed on pre-eclamptic patients and healthy controls. We developed two dynamical physical models, both based on two characteristic time constants: for PORH, an "arterial" and a "capillary" time constant and, for iontophoresis, a "diffusion" and a "decay" time constant. RESULTS: For the different subject groups, we could extract time constants that could probably be related to physiological differences. For iontophoresis, a shot saturation constant was determined, with very different values for different groups and administered drugs. CONCLUSIONS: With these models, the dynamics of the provocations can be investigated and quantitative comparisons between experiments and subject groups become available. The models offer a quantifiable standard that is independent of the type of LDPM instrumentation.


Assuntos
Hiperemia/fisiopatologia , Iontoforese/métodos , Fluxometria por Laser-Doppler/métodos , Modelos Teóricos , Estudos de Casos e Controles , Diabetes Mellitus/fisiopatologia , Feminino , Humanos , Fluxometria por Laser-Doppler/normas , Masculino , Perfusão/métodos , Doenças Vasculares Periféricas/fisiopatologia , Pré-Eclâmpsia/fisiopatologia , Gravidez , Fatores de Tempo
5.
Phys Med Biol ; 53(10): 2667-75, 2008 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-18443389

RESUMO

We designed and developed a laser line-triangulation endoscope compatible with any standard high-speed camera for a complete three-dimensional profiling of human vocal fold vibration dynamics. With this novel device we are able to measure absolute values of vertical and horizontal vibration amplitudes, length and width of vocal folds as well as the opening and closing velocities from a single in vivo measurement. We have studied, for the first time, the generation and propagation of mucosal waves by locating the position of its maximum vertical position and the propagation velocity. Precise knowledge about the absolute dimensions of human vocal folds and their vibration parameters has significant importance in clinical diagnosis and treatment as well as in fundamental research in voice. The new device can be used to investigate different kinds of pathological conditions including periodic or aperiodic vibrations. Consequently, the new device has significant importance in investigating vocal fold paralysis and in phonosurgical applications.


Assuntos
Imageamento Tridimensional/métodos , Quimografia/métodos , Vibração , Prega Vocal/fisiologia , Calibragem , Humanos , Lasers , Fatores de Tempo
6.
J Biomed Opt ; 13(6): 064024, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19123670

RESUMO

We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation images of the vocal folds are recorded at the rate of 4000 fps with a resolution of 256x256 pixels. A special image-processing algorithm is developed to precisely follow the subpixel movements of the laser line image. Vibration profiles in both horizontal and vertical directions are calibrated and measured in absolute SI units with a resolution of +/-50 microm. We also present a movie showing the vocal folds dynamics in vertical cross section.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Laringoscópios , Fonação/fisiologia , Gravação em Vídeo/instrumentação , Prega Vocal/anatomia & histologia , Prega Vocal/fisiologia , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Medida da Produção da Fala/instrumentação , Medida da Produção da Fala/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-18002895

RESUMO

Laser Doppler flux signals show temporal fluctuations caused by physiological phenomena like heartbeat, respiration, and local variation of vascular tonus, vasomotion. This study investigates the influence of fiber arrangement, equipment and two probe locations on the variations in laser Doppler flux signals in five frequency bands in the absence of provocations. Two probes with detecting optical fibers at several distances from the illuminating source were used, as well as instruments from two manufacturers. The results show that normalization of the filtered flux signals with the mean flux leads to an enormous decrease of the influence of fiber distance. The difference between instruments is small after normalization. Some influence of probe location remains after normalization. Development of a standard method for normalization of the variations in laser Doppler signals is recommended.


Assuntos
Tecnologia de Fibra Óptica , Fluxometria por Laser-Doppler/instrumentação , Fluxometria por Laser-Doppler/métodos , Tecnologia de Fibra Óptica/métodos , Humanos , Contração Miocárdica , Variações Dependentes do Observador , Fibras Ópticas , Mecânica Respiratória
8.
J Biomed Opt ; 12(1): 014032, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17343507

RESUMO

We present a physical model to describe iontophoresis time recordings. The model is a combination of monodimensional material diffusion and decay, probably due to transport by blood flow. It has four adjustable parameters, the diffusion coefficient, the decay constant, the height of the response, and the shot saturation constant, a parameter representing the relative importance of subsequent shots (in case of saturation). We test the model with measurements of blood perfusion in the capillary bed of the fingers of women who recently had preeclampsia and in women with a history of normal pregnancy. From the fits to the measurements, we conclude that the model provides a useful physical description of the iontophoresis process.


Assuntos
Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/farmacocinética , Iontoforese/métodos , Modelos Biológicos , Pré-Eclâmpsia/tratamento farmacológico , Pré-Eclâmpsia/fisiopatologia , Absorção Cutânea , Anti-Hipertensivos/química , Simulação por Computador , Difusão , Feminino , Humanos , Fluxometria por Laser-Doppler/métodos , Gravidez , Valores de Referência , Pele/química
9.
IEEE Trans Biomed Eng ; 53(10): 2067-74, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17019871

RESUMO

An integrated optoelectronic probe with small dimensions, for direct-contact laser Doppler blood flow monitoring has been realized. A vertical cavity surface emitting laser (VCSEL), and a chip with photodetectors and all necessary electronics are integrated in a miniature probe head connected to a laptop computer. The computer sound processor is utilized for acquisition and digital signal processing of the incoming Doppler signal. In this paper, the design of the laser Doppler perfusion monitor is described and its performance is evaluated. We demonstrate our perfusion monitor to be less sensitive to subject motion than a commercial fiber-optic device. For medium and high perfusion levels, the performance of our integrated probe is comparable to the fiberoptic flowmeter containing a normal edge-emitting laser diode. For very low perfusion levels, the signal-to-noise ratio of the fiber-optic device is higher. This difference can mainly be attributed to the shorter coherence length of the VCSEL compared with the edge-emitting laser diode.


Assuntos
Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/métodos , Eletrônica Médica , Fluxometria por Laser-Doppler/instrumentação , Óptica e Fotônica/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Fluxometria por Laser-Doppler/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
10.
IEEE Trans Biomed Eng ; 52(2): 184-90, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15709655

RESUMO

To facilitate the quantitative analysis of post-occlusive reactive hyperaemia (PORH), measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow model for the dynamics of the perfusion of the tissue during PORH, based on three parameters: two time constants (tau1 and tau2) and the ratio of the maximum flux and the resting flux. With these three constants quantitative comparisons between experiments will be possible and, therefore, we propose to adopt this approach as future standard. For this reason, we also developed a computer program to perform the fit of the model to measured data.


Assuntos
Algoritmos , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Diagnóstico por Computador/métodos , Hiperemia/diagnóstico , Hiperemia/fisiopatologia , Fluxometria por Laser-Doppler/métodos , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Angiopatias Diabéticas/diagnóstico , Angiopatias Diabéticas/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Lasers Surg Med ; 35(5): 354-62, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15611959

RESUMO

BACKGROUND AND OBJECTIVES: The ability to correctly visualize the architectural arrangement of microvasculature is valuable to many diverse fields in medicine. In this study, we applied photoacoustics (PA) to obtain high-resolution images of submillimeter blood vessels. STUDY DESIGN/MATERIALS AND METHODS: Short laser pulses are used to generate ultrasound from superficial blood vessels in several animal models. From these ultrasound waves the interior of blood vessels can be reconstructed. RESULTS: We present results from a novel approach based on the PA principle that allows specific in vivo visualization of dermal blood vessels without the use of contrast agents or ionizing radiation. CONCLUSIONS: We show PA images of externalized blood vessels and demonstrate in vivo PA imaging of vasculature through layers of skin varying in thickness.


Assuntos
Acústica , Lasers , Mesentério/irrigação sanguínea , Microcirculação/diagnóstico por imagem , Pele/irrigação sanguínea , Animais , Modelos Animais , Coelhos , Ratos , Ultrassonografia
12.
J Biomed Opt ; 9(6): 1327-35, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15568955

RESUMO

A photoacoustic double-ring sensor, featuring a narrow angular aperture, is developed for laser-induced photoacoustic imaging of blood vessels. An integrated optical fiber enables reflection-mode detection of ultrasonic waves. By using the cross-correlation between the signals detected by the two rings, the angular aperture of the sensor is reduced by a factor of 1.9, from 1.5 to 0.8 deg. Consequently, photoacoustic images could be obtained in a manner analogous to the ultrasound B-scan mode. Next, the cross section of artificial blood vessels is visualized by reconstruction of the absorbed energy distribution. Finally, in vivo imaging and the subsequent reconstruction of the absorbed energy distribution is demonstrated for superficial blood vessels in the human wrist.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Lasers , Tomografia/instrumentação , Transdutores , Ultrassonografia/instrumentação , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Tomografia/métodos , Ultrassonografia/métodos
13.
Phys Med Biol ; 49(20): 4745-56, 2004 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-15566172

RESUMO

A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-to-peak time (tau(pp)) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel diameter showed that the diameter could be approximated by 2ctau(pp), with c the speed of sound in blood. Using this relation, the lateral diameter could also precisely be determined. In vivo imaging and monitoring of changes in vessel diameters was feasible. Finally, acoustic time traces were recorded while flushing a vessel in the rabbit ear with saline, which proved that the main contribution to the laser-induced pressure transient is caused by blood inside the vessel and that the vessel wall gives only a minor contribution.


Assuntos
Acústica , Vasos Sanguíneos/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Lasers , Tomografia/métodos , Algoritmos , Animais , Orelha/anatomia & histologia , Orelha/irrigação sanguínea , Estudos de Viabilidade , Imagens de Fantasmas , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia/instrumentação , Vibração
14.
Appl Opt ; 43(10): 2059-65, 2004 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15074413

RESUMO

The effects of fiber coupling and fiber length on photocurrent fluctuations are studied when the light of a laser diode transmitted to and from a dynamic turbid medium by a step-index multimode fiber is studied. When the laser light is coupled asymmetrically, filling only the higher-order modes, the photocurrent fluctuations are suppressed significantly when fiber lengths of as much as 16 m are added between the laser and the medium. Addition of as much as 16 m of detection fiber, or any fiber in the case of symmetric light coupling, leads to much less or no suppression of the photocurrent fluctuations.

15.
J Biomed Opt ; 8(2): 191-205, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12683845

RESUMO

We determine temperature effect on the absorption and reduced scattering coefficients (mu(a) and mu(s)(')) of human forearm skin. Optical and thermal simulation data suggest that mu( a) and mu(s)(') are determined within a temperature-controlled depth of approximately 2 mm. Cutaneous mu(s)(') change linearly with temperature. Change in mu(a) was complex and irreversible above body normal temperatures. Light penetration depth (delta) in skin increased on cooling, with considerable person-to-person variations. We attribute the effect of temperature on mu(s)(') to change in refractive index mismatch, and its effect on mu(a) to perfusion changes. The reversible temperature effect on mu (s)(' ) was maintained during more than 90 min. contact between skin and the measuring probe, where temperature was modulated between 38 and 22 degrees C for multiple cycles While temperature modulated mu(s)(' ) instantaneously and reversibly, mu(a) exhibited slower response time and consistent drift. There was a statistically significant upward drift in mu(a) and a mostly downward drift in mu( s)(') over the contact period. The drift in temperature-induced fractional change in mu(s)(') was less statistically significant than the drift in mu(s)('). Deltamu( s)(') values determined under temperature modulation conditions may have less nonspecific drift than mu(s)(') which may have significance for noninvasive determination of analytes in human tissue.


Assuntos
Luz , Modelos Biológicos , Fenômenos Fisiológicos da Pele/efeitos da radiação , Pele/efeitos da radiação , Temperatura , Tomografia Óptica/métodos , Absorção , Simulação por Computador , Relação Dose-Resposta à Radiação , Antebraço/patologia , Antebraço/fisiologia , Antebraço/efeitos da radiação , Temperatura Alta , Humanos , Raios Infravermelhos , Imagens de Fantasmas , Espalhamento de Radiação , Pele/citologia , Temperatura Cutânea/fisiologia , Temperatura Cutânea/efeitos da radiação
16.
Phys Med Biol ; 48(3): 357-70, 2003 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-12608612

RESUMO

Materials for solid photoacoustic breast phantoms, based on poly(vinyl alcohol) hydrogels, are presented. Phantoms intended for use in photoacoustics must possess both optical and acoustic properties of tissue. To realize the optical properties of tissue, one approach was to optimize the number of freezing and thawing cycles of aqueous poly(vinyl alcohol) solutions, a procedure which increases the turbidity of the gel while rigidifying it. The second approach concentrated on forming a clear matrix of the rigid poly(vinyl alcohol) gel without any scattering, so that appropriate amounts of optical scatterers could be added at the time of formation, to tune the optical properties as per requirement. The relevant optical and acoustic properties of such samples were measured to be close to the average properties of human breast tissue. Tumour simulating gel samples of suitable absorption coefficient were created by adding appropriate quantities of dye at the time of formation; the samples were then cut into spheres. A breast phantom embedded with such 'tumours' was developed for studying the applicability of photoacoustics in mammography.


Assuntos
Géis , Imagens de Fantasmas , Álcool de Polivinil , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Ultrassonografia Mamária/instrumentação , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Desenho de Equipamento , Humanos , Mamografia/instrumentação , Mamografia/métodos , Teste de Materiais/métodos , Espalhamento de Radiação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Técnica de Subtração , Ultrassonografia Mamária/métodos
17.
Appl Opt ; 41(4): 658-67, 2002 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-11993911

RESUMO

We have developed a blood velocimeter based on the principle of self-mixing in a semiconductor laser diode through an optical fiber. The intensity of the light is modulated by feedback from moving scattering particles that contain the Doppler-shift frequency. Upon feedback the characteristics of the laser diode change. The threshold current decreases, and an instable region may become present above the new threshold. The amplitude of the Doppler signal turns out to be related to the difference in intensity between situations with and without feedback. This amplitude is highest just above feedback. The suppression of reflection from the glass-fiber facets is of paramount importance in the obtaining of a higher signal-to-noise ratio. Using an optical stabilization of the feedback, we optimized the performance of the laser-fiber system and the Doppler modulation depth and clarified its behavior with a suitable physical model. We also investigated the effect of the finite coherence length of the laser. We tested the efficiency of the self-mixing velocimeter in vivo with the optical glass fiber inserted in the artery with endoscopic catheters, both in upstream and in downstream blood flow conditions. For the latter we used a special side-reflecting device solution for the fiber facet to allow downstream measurements.


Assuntos
Artérias/fisiologia , Fluxometria por Laser-Doppler , Modelos Teóricos , Animais , Retroalimentação , Vidro , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...