Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1720: 464809, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490141

RESUMO

An ultrafast, efficient, and eco-friendly method combining magnetic solid phase extraction and capillary electrophoresis with diode array detection have been developed to determine ractopamine residues in food samples. A restricted access material based on magnetic and mesoporous molecularly imprinted polymer has been properly synthesized and characterized, demonstrating excellent selectivity and high adsorbent capacity. Short-end injection capillary electrophoresis method was optimized: 75 mM triethylamine pH 7 as BGE, -20 kV, 50 mbar by hydrodynamic injection during 8 s, and capillary temperature at 25 °C; reaching ultrafast ractopamine analysis (∼0.6 min) with good peak asymmetry, and free from interfering and/or baseline noise. After sample preparation optimization, the conditions were: 1000 µL of sample at pH 6, 20 mg of adsorbent, stirring time of 120 s, 250 µL of ultrapure water as washing solvent, 1000 µL of methanol: acetic acid (7: 3, v/v) as eluent, and the adsorbent can be reused four times. In these conditions, the analytical method showed recoveries around to 100 %, linearity ranged from 9.74 to 974.0 µg kg-1, correlation coefficient (r) ≥ 0,99 in addition to adequate precision, accuracy, and robustness. After proper validation, the method was successfully applied in the analysis ractopamine residues in bovine milk and bovine and porcine muscle.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Fenetilaminas , Animais , Suínos , Extração em Fase Sólida/métodos , Eletroforese Capilar/métodos , Fenômenos Magnéticos , Impressão Molecular/métodos , Cromatografia Líquida de Alta Pressão/métodos
2.
Food Chem ; 345: 128745, 2021 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-33302105

RESUMO

In this work, we report the synthesis of a mesoporous molecularly imprinted polymer on the surface of silica nanoparticles (core@mMIP) to be applied as adsorbent in microextraction by packed sorbent (MEPS) for selective determination of pesticides in apple juice. The core@mMIP was properly characterized, showing good adhesion of the polymer to the silica core. The best extraction conditions were: 200 µL of ultrapure water as washing solvent, 150 µL of acetonitrile as eluent, 100 µL of sample at pH 2.5, five draw-eject cycles and 8 mg of adsorbent. Thereby, recoveries of 96.12 ± 1.05%, 76.88 ± 6.18% and 76.18 ± 5.57% were obtained for pyriproxyfen (PPX), deltamethrin (DTM) and etofenprox (ETF), respectively. After validation, the method presented linearity in the range of 0.02-10 µg mL-1 (r > 0.99), limit of detection of 0.005 µg mL-1, satisfactory selectivity, and proper precision and accuracy. The method was successfully applied real samples of processed and fresh apple juice.


Assuntos
Análise de Alimentos/métodos , Sucos de Frutas e Vegetais/análise , Malus/química , Nanopartículas/química , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Dióxido de Silício/química , Adsorção , Contaminação de Alimentos/análise , Polímeros Molecularmente Impressos/química , Porosidade , Solventes/química , Água/química
3.
J Chromatogr Sci ; 57(7): 671-678, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31004427

RESUMO

Herein, an organic-inorganic hybrid molecularly imprinted polymer (MIP) was successfully synthesized with albendazole sulfoxide (ABZSO) as a template and 3-(trimethoxysilyl)propyl methacrylate, a bifunctional group compound, as a single cross-linking agent. In this study, a simple method using HPLC-DAD was developed for the determination of ABZSO enantiomers in human urine using pipette tip-based molecularly imprinted polymer solid phase extraction (PT-MIP-SPE). Enantioseparation with satisfactory retention times (5.17 and 7.09 min), acceptable theoretical plates (N = 4,535 and 5,091) and strong resolution (Rs = 5.45) was performed with an Agilent® Eclipse Plus C18 (100 mm × 4.6 mm, 3.5 µm) coupled with a Chiralpak® IA column (100 mm × 4.6 mm, 3 µm), a mixture with ethanol:water (50:50, v/v) as the mobile phase, temperature at 40°C, flow rate at 0.9 mL min-1 and λ = 230 nm. Thereafter, certain parameters affecting the PT-MIP-SPE were investigated in detail and the better conditions were: 300 µL of water as washing solvent, 500 µL of ethanol:acetic acid (9:1, v/v) as eluting solvent, 20 mg of MIP, 500 µL of human urine at pH 9 and no addition of NaCl. Recoveries/relative standard deviation (RSD%) for (R)-(+)-ABZSO and (S)-(-)-ABZSO were 78.2 ± 0.2% and 69.7 ± 1.7%, respectively.

4.
J Pharm Anal ; 8(3): 168-175, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29922485

RESUMO

This study aimed to show that the physicochemical proprieties obtained by Fourier transform infrared spectroscopy (FTIR), thermogravimetry (TG), and scanning electronic microscopy (SEM) can be useful tools for evaluating the quality of active pharmaceutical ingredients (APIs) and pharmaceutical products. In addition, a simple, sensitive, and efficient method employing HPLC-DAD was developed for simultaneous determination of lidocaine (LID), ciprofloxacin (CFX) and enrofloxacin (EFX) in raw materials and in veterinary pharmaceutical formulations. Compounds were separated using a Gemini C18 (250 mm × 4.6 mm, 5 µm) Phenomenex® column, at a temperature of 25 °C, with a mobile phase containing 10 mM of phosphoric acid (pH 3.29): acetonitrile (85.7:14.3, v/v) and a flow rate of 1.5 mL/min. Physicochemical characterization by TG, FTIR, and SEM of raw materials of LID, CFX, and EFX provided information useful for the evaluation, differentiation, and qualification of raw materials. Finally, the HPLC method was proved to be useful for evaluation of raw material and finished products, besides satisfying the need for an analytical method that allows simultaneous determination of EFX, CFX, and LID, which can also be extended to other matrices and applications.

5.
Electrophoresis ; 39(20): 2581-2589, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29772601

RESUMO

In this work a hollow mesoporous structured molecularly imprinted polymer was synthetized and used as adsorbent in pipette-tip solid-phase extraction for the determination of lamivudine (3TC), zidovudine (AZT) and efavirenz (EFZ) from plasma of human immunodeficiency virus (HIV) infected patients by high-performance liquid chromatography (HPLC). All parameters that influence the recovery of the pipette tip based on hollow mesoporous molecularly imprinted polymer solid-phase extraction (PT-HM-MIP-SPE) method were systematically studied and discussed in detail. The adsorbent material was prepared using methacrylic acid and 4-vinylpyridine as functional monomers, ethylene glycol dimethacrylate as crosslinker, acetonitrile as solvent, 4,4'-azobis(4-cyanovaleric acid) as radical initiator, benzalkonium chloride as surfactant, 3TC, and AZT as templates. The simultaneous separation of 3TC, AZT and EFZ by HPLC-UV was performed using a Gemini C18 Phenomenex® column (250 mm × 4.6 mm, 5 µm) and mobile phase consisting of acetonitrile: water pH 3.2 (68:32, v/v), flow rate of 1.0 mL/min and λ = 260 nm. The method was linear over the concentration range from 0.25 to 10 µg/mL for 3TC and EFZ, and 0.05 to 2.0 µg mL-1 for AZT, with correlation coefficients larger than 0.99 for all analytes. Recovery ± relative standard deviations (RSDs %) were 41.99 ± 2.38%, 82.29 ± 1.63%, and 83.72 ± 7.52% for 3TC, AZT, and EFZ, respectively. The RSDs and relative errors (REs) were lower than 15% for intra and interday assays. The method has been successfully applied for monitoring HIV-infected patients outside the therapeutic dosage.


Assuntos
Antirretrovirais/sangue , Infecções por HIV/tratamento farmacológico , Impressão Molecular/métodos , Extração em Fase Sólida/métodos , Antirretrovirais/isolamento & purificação , Antirretrovirais/uso terapêutico , Cromatografia Líquida de Alta Pressão , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1061-1062: 399-410, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28803116

RESUMO

In this work, an efficient pipette tip based on molecularly imprinted polymers solid-phase extraction (PT-MIP-SPE) method was developed for carvedilol (CAR) analysis. This compound is available in clinical practice as a racemic mixture, in which (-)-(S)-CAR is a ß- and α1-adrenergic antagonist, while (+)-(R)-CAR only acts as an α1-adrenergic antagonist. Enantioseparation of CAR presented satisfactory retention times (5.85 and 14.84min), acceptable theoretical plates (N=2048 and 2018) and good resolution (Rs=9.27). The separation was performed using a Chiralpak® IA column (100mm×4.6mm, 3µm), a mixture of methanol:ethanol:water (64:15:21, v/v/v) plus 0.3% diethylamine as mobile phase, temperature of 35°C and flow rate of 1.5mLmin-1. After density functional theory calculations based on prepolymerization complexes, the best protocol for the MIP synthesis was chosen. Then, some parameters that affect the PT-MIP-SPE technique were investigated. After optimization, the best conditions were 300µL of water as washing solvent, 500µL of acetonitrile:acetic acid (7:3, v/v) as eluting solvent, 20mg of MIP, 500µL of urine sample (pH 12.5) and no addition of NaCl. Recoveries±relative standard deviation (RSD%) for (+)-(R)-CAR and (-)-(S)-CAR were 101.9±4.8% and 104.6±2.1%, respectively. The method was linear over the concentration range from 20 to 1280ngmL-1 for each enantiomer, with correlation coefficients larger than 0.99 for both enantiomers. The method was applied successfully in a preliminary study of urinary excretion after administration of CAR racemate to a healthy volunteer.


Assuntos
Carbazóis/química , Carbazóis/urina , Impressão Molecular/métodos , Propanolaminas/química , Propanolaminas/urina , Extração em Fase Sólida/métodos , Carvedilol , Cromatografia Líquida de Alta Pressão , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Estereoisomerismo
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1033-1034: 27-39, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27517523

RESUMO

A simple method using HPLC-DAD was developed for the determination of fluoroquinolones in human urine including ciprofloxacin (CIPRO), enrofloxacino (ENRO), marbofloxacino (MARBO) and norfloxacin (NOR). In addition, it was studied the extraction of fluoroquinolones in human urine samples using pipette tip-based molecularly imprinted polymers solid phase extraction (PT-MIPs-SPE). With the goal of finding the best procedure for extraction of four fluoroquinolones in human urine, several parameters that are likely to affect the efficiency of extraction during sample preparation, including the washing solvent, type and volume of eluent, amount of material, the volume of the sample, pH and the ionic strength were systematically optimized. Chromatographic separations of fluoroquinolones were hit within 10min using a Synergi(®) C18 (250×4.6mm, 4µm) column and mobile phase consisting of water (10mM of phosphoric acid, the pH adjusted at 3.29 with triethylamine) : acetonitrile (85.7: 14.3, v/v) at a flow rate of 1.5mLmin(-1). Detection was performed at 290nm. The average extraction recoveries/standard deviation relative to ENRO, CIPRO, NOR and MARBO were 96.40±5.51%, 42.47±4.81%, 41.82±7.99% and 87.49±4.70, respectively. The method was liner from 39 to 1260ngmL(-1) for each fluoroquinolone with correlation coefficient of 0.9904, 0.9910, 0.9914 and 0.9919, to ENRO, CIPRO, NOR and MARBO, respectively. The assays of within-day and between-day precision and accuracy for all analytes were studied at three concentration levels and were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of CIPRO to a healthy volunteer.


Assuntos
Fluoroquinolonas/urina , Impressão Molecular/métodos , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Fluoroquinolonas/química , Fluoroquinolonas/isolamento & purificação , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...