1.
Oper Dent ; 44(6): 625-636, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30702411

RESUMO

OBJECTIVE: To analyze the shrinkage stress, bonding interaction, and failure modes between different low-viscosity bulk fill resin composites and conventional resin composites produced by the same manufacturer or a high-viscosity bulk fill resin composite used to restore the occlusal layer in posterior teeth. METHODS & MATERIALS: Three low-viscosity bulk fill resin composites were associated with the conventional resin composites made by the same manufacturers or with a high-viscosity bulk fill resin composite, resulting in six groups (n=10). The bonding interaction between resin composites was tested by assessing the microshear bond strength (µSBS). The samples were thermocycled and were tested with 1-mm/min crosshead speed, and the failure mode was evaluated. The post-gel shrinkage (Shr) of all the resin composites was measured using a strain gauge (n=10). The modulus of elasticity (E) and the hardness (KHN) were measured using the Knoop hardness test. Two-dimensional finite element models were created for analyzing the stress caused by shrinkage and contact loading. The µSBS, Shr, E, and KHN data were analyzed using the Student t-test and one-way analysis of variance. The failure mode data were subjected to chi-square analysis (α=0.05). The stress distribution was analyzed qualitatively. RESULTS: No significant difference was verified for µSBS between low-viscosity bulk fill resin composites and conventional or high-viscosity bulk fill composites in terms of restoring the occlusal layer (p=0.349). Cohesive failure of the low-viscosity bulk fill resin composites was the most frequent failure mode. The Shr, E, and KHN varied between low-viscosity and high-viscosity resin composites. The use of high-viscosity bulk fill resin composites on the occlusal layer reduced the stress at the enamel interface on the occlusal surface. CONCLUSIONS: The use of high-viscosity bulk fill resin composites as an occlusal layer for low-viscosity bulk fill resin composites to restore the posterior teeth can be a viable alternative, as it shows a similar bonding interaction to conventional resin composites as well as lower shrinkage stress at the enamel margin.


Assuntos
Resinas Compostas , Esmalte Dentário , Dureza , Humanos , Teste de Materiais , Polimerização , Viscosidade
2.
Oper Dent ; 43(1): 71-80, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28976847

RESUMO

OBJECTIVES: To analyze the effect of pulp-capping materials and resin composite light activation on strain and temperature development in the pulp and on the interfacial integrity at the pulpal floor/pulp-capping materials in large molar class II cavities. METHODS: Forty extracted molars received large mesio-occlusal-distal (MOD) cavity bur preparation with 1.0 mm of dentin remaining at the pulp floor. Four pulp-capping materials (self-etching adhesive system, Clearfil SE Bond [CLE], Kuraray), two light-curing calcium hydroxide cements (BioCal [BIO], Biodinâmica, and Ultra-Blend Plus [ULT], Ultradent), and a resin-modified glass ionomer cement- (Vitrebond [VIT], 3M ESPE) were applied on the pulpal floor. The cavities were incrementally restored with resin composite (Filtek Z350 XT, 3M ESPE). Thermocouple (n=10) and strain gauge (n=10) were placed inside the pulp chamber in contact with the top of the pulpal floor to detect temperature changes and dentin strain during light curing of the pulp-capping materials and during resin composite restoration. Exotherm was calculated by subtracting postcure from polymerization temperature (n=10). Interface integrity at the pulpal floor was investigated using micro-CT (SkyScan 1272, Bruker). The degree of cure of capping materials was calculated using the Fourier transform infrared and attenuated total reflectance cell. Data were analyzed using one-way analysis of variance followed by the Tukey test (α=0.05). RESULTS: Pulpal dentin strains (µs) during light curing of CLE were higher than for other pulp-capping materials ( p<0.001). During resin composite light activation, the pulpal dentin strain increased for ULT, VIT, and CLE and decreased for BIO. The pulpal dentin strain was significantly higher during pulp-capping light activation. The temperature inside the pulp chamber increased approximately 3.5°C after light curing the pulp-capping materials and approximately 2.1°C after final restoration. Pulp-capping material type had no influence temperature increase. The micro-CT showed perfect interfacial integrity after restoration for CLE and ULT; however, gaps were found between BIO and pulpal floor in all specimens. BIO had a significantly lower degree of conversion than ULT, VIT, and CLE. CONCLUSIONS: Light curing of pulp-capping materials caused deformation of pulpal dentin and increased pulpal temperature in large MOD cavities. Shrinkage of the resin composite restoration caused debonding of BIO from the pulpal floor.


Assuntos
Resinas Compostas/uso terapêutico , Polpa Dentária/efeitos da radiação , Dentina/efeitos da radiação , Cura Luminosa de Adesivos Dentários , Agentes de Capeamento da Polpa Dentária e Pulpectomia/efeitos da radiação , Temperatura Corporal , Polpa Dentária/efeitos dos fármacos , Dentina/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/efeitos adversos , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários/métodos