RESUMO
OBJECTIVE: To analyze the shrinkage stress, bonding interaction, and failure modes between different low-viscosity bulk fill resin composites and conventional resin composites produced by the same manufacturer or a high-viscosity bulk fill resin composite used to restore the occlusal layer in posterior teeth. METHODS & MATERIALS: Three low-viscosity bulk fill resin composites were associated with the conventional resin composites made by the same manufacturers or with a high-viscosity bulk fill resin composite, resulting in six groups (n=10). The bonding interaction between resin composites was tested by assessing the microshear bond strength (µSBS). The samples were thermocycled and were tested with 1-mm/min crosshead speed, and the failure mode was evaluated. The post-gel shrinkage (Shr) of all the resin composites was measured using a strain gauge (n=10). The modulus of elasticity (E) and the hardness (KHN) were measured using the Knoop hardness test. Two-dimensional finite element models were created for analyzing the stress caused by shrinkage and contact loading. The µSBS, Shr, E, and KHN data were analyzed using the Student t-test and one-way analysis of variance. The failure mode data were subjected to chi-square analysis (α=0.05). The stress distribution was analyzed qualitatively. RESULTS: No significant difference was verified for µSBS between low-viscosity bulk fill resin composites and conventional or high-viscosity bulk fill composites in terms of restoring the occlusal layer (p=0.349). Cohesive failure of the low-viscosity bulk fill resin composites was the most frequent failure mode. The Shr, E, and KHN varied between low-viscosity and high-viscosity resin composites. The use of high-viscosity bulk fill resin composites on the occlusal layer reduced the stress at the enamel interface on the occlusal surface. CONCLUSIONS: The use of high-viscosity bulk fill resin composites as an occlusal layer for low-viscosity bulk fill resin composites to restore the posterior teeth can be a viable alternative, as it shows a similar bonding interaction to conventional resin composites as well as lower shrinkage stress at the enamel margin.
Assuntos
Resinas Compostas , Esmalte Dentário , Dureza , Humanos , Teste de Materiais , Polimerização , ViscosidadeRESUMO
OBJECTIVES: To analyze the effect of pulp-capping materials and resin composite light activation on strain and temperature development in the pulp and on the interfacial integrity at the pulpal floor/pulp-capping materials in large molar class II cavities. METHODS: Forty extracted molars received large mesio-occlusal-distal (MOD) cavity bur preparation with 1.0 mm of dentin remaining at the pulp floor. Four pulp-capping materials (self-etching adhesive system, Clearfil SE Bond [CLE], Kuraray), two light-curing calcium hydroxide cements (BioCal [BIO], Biodinâmica, and Ultra-Blend Plus [ULT], Ultradent), and a resin-modified glass ionomer cement- (Vitrebond [VIT], 3M ESPE) were applied on the pulpal floor. The cavities were incrementally restored with resin composite (Filtek Z350 XT, 3M ESPE). Thermocouple (n=10) and strain gauge (n=10) were placed inside the pulp chamber in contact with the top of the pulpal floor to detect temperature changes and dentin strain during light curing of the pulp-capping materials and during resin composite restoration. Exotherm was calculated by subtracting postcure from polymerization temperature (n=10). Interface integrity at the pulpal floor was investigated using micro-CT (SkyScan 1272, Bruker). The degree of cure of capping materials was calculated using the Fourier transform infrared and attenuated total reflectance cell. Data were analyzed using one-way analysis of variance followed by the Tukey test (α=0.05). RESULTS: Pulpal dentin strains (µs) during light curing of CLE were higher than for other pulp-capping materials ( p<0.001). During resin composite light activation, the pulpal dentin strain increased for ULT, VIT, and CLE and decreased for BIO. The pulpal dentin strain was significantly higher during pulp-capping light activation. The temperature inside the pulp chamber increased approximately 3.5°C after light curing the pulp-capping materials and approximately 2.1°C after final restoration. Pulp-capping material type had no influence temperature increase. The micro-CT showed perfect interfacial integrity after restoration for CLE and ULT; however, gaps were found between BIO and pulpal floor in all specimens. BIO had a significantly lower degree of conversion than ULT, VIT, and CLE. CONCLUSIONS: Light curing of pulp-capping materials caused deformation of pulpal dentin and increased pulpal temperature in large MOD cavities. Shrinkage of the resin composite restoration caused debonding of BIO from the pulpal floor.