Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Oral Implants Res ; 34 Suppl 26: 240-256, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750525

RESUMO

OBJECTIVE: Fundamentally, this review addresses the following question: In partially or fully edentulous patients, do implant-supported dental prostheses preserve orofacial tissues when compared to conventional prostheses or no therapy? MATERIALS AND METHODS: This study was conducted according to the 2020 PRISMA guidelines for systematic reviews. Electronic searches were conducted at PubMed and Embase databases followed by manual search. Clinical studies comparing the effect of implant-supported prostheses with conventional rehabilitation or no treatment on alveolar bone resorption, remaining teeth, and jaw muscle thickness were considered for inclusion. A qualitative synthesis was conducted with all included studies, and data from selected studies were pooled quantitatively to perform a meta-analysis. RESULTS: A total of 14 studies were selected for analysis. Six studies reported on the effect of implant therapy on alveolar bone resorption (n = 453), six on the remaining teeth (n = 1014), while four studies evaluated masseter muscle thickness (n = 158). The results of the meta-analyses assessing alveolar bone resorption in the posterior mandible and in the anterior area of the maxilla, both fixed and random effects models, yielded no benefit of rehabilitation with implant-supported prostheses when compared to conventional prostheses. For masseter bone thickness, however, a significant benefit for implant-supported prosthesis was observed. CONCLUSIONS: This systematic review and meta-analysis were unable to unequivocally answer the focus question. There are some indicators of the benefit of implant-supported prostheses over conventional prostheses or no therapy in preserving orofacial tissues, particularly for masseter muscle thickness. However, the evidence is still insufficient to confirm such perception.


Assuntos
Perda do Osso Alveolar , Humanos , Perda do Osso Alveolar/prevenção & controle , Bases de Dados Factuais , Mandíbula , Músculo Masseter , Implantação Dentária
2.
Artigo em Inglês | MEDLINE | ID: mdl-37141083

RESUMO

Implant esthetic complications can negatively affect a patient's perception of implant therapy and their quality of life. This article discusses the etiology, prevalence, and strategies for the treatment of peri-implant soft tissue dehiscences/deficiencies (PSTDs). Three common scenarios of implant esthetic complications were identified and described, in which PSTDs could be managed without removing the crown (scenario I), with the surgical-prosthetic approach (crown removal; scenario II), and/or with the horizontal and vertical soft tissue augmentation and submerged healing (scenario III).


Assuntos
Implantes Dentários , Humanos , Implantes Dentários/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Qualidade de Vida , Estética Dentária , Assistência Centrada no Paciente
3.
J Prosthet Dent ; 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37121851

RESUMO

STATEMENT OF PROBLEM: Different 3D printers are available for guided implant surgery, but studies that evaluate their source of errors and their cost-effectiveness are lacking. PURPOSE: The purpose of this in vitro study was to compare the accuracy of different 3-dimensional (3D) printed surgical templates made using different additive manufacturing technologies and to evaluate the effect of implant location on the accuracy of fully guided implant placement. MATERIAL AND METHODS: Fifty partially edentulous maxillary typodonts with edentulous sites in the right second premolar (SP), right lateral incisor (LI), left central incisor (CI), and left first molar (FM) locations were scanned and printed from the standard tessellation language (STL) datasets. The study compared 5 groups for the fabrication of implant surgical templates: Varseo S-Bego (Bego), Polyjet-Stratasys (Poly), Low Force Stereolithography-FormLabs (LFS), P30+-Straumann (P30), and M2-Carbon (M2). After fully guided implant placement, the typodont was scanned, and the 3D implant positions were compared with the master model by superimposing the STL files. Descriptive statistics were calculated for groups and subgroups, and comparisons among the groups and subgroups were conducted via 2-way mixed analysis of variance, Tukey honest significant difference, and post hoc Bonferroni tests (α=.05). RESULTS: The results were site specific and not consistent within each group. For angle deviation, the within-group analysis for P30 demonstrated significantly lower values for implants positioned at site SP (1.4 ±0.8 degrees) than for sites LI (2.3 ±0.7 degrees; P=.001) and CI (2.3 ±0.8 degrees; P=.007). For 3D offset at base for implant CI, LFS was significantly higher than Bego (P=.002), Poly (P=.035), or M2 (P=.001); P30 was also significantly higher than Bego (P=.014) and M2 (P=.006). LFS had a significantly higher 3D offset at the tip than Bego (P=.001) and M2 (P=.022) for implant CI. CONCLUSIONS: The choice of 3D printer seemed to influence fully guided implant surgery in terms of the final implant position compared with initial implant planning. However, although statistically significant differences were present across groups, all additive manufacturing technologies were within clinically acceptable values.

4.
J Oral Implantol ; 48(5): 351-357, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937081

RESUMO

The aims of this study were to evaluate the effect of (1) the different surgical guide designs and (2) implant placement location on the accuracy of fully guided implant placement in single edentulous sites using an in vitro study model. Forty-five partially edentulous models were scanned and divided into 3 groups: group 1, tooth-supported full-arch surgical guide; group 2, 3 different tooth-supported shortened surgical guides (SSGs); and group 3, tooth-supported full-arch surgical guide with a crossbar. All surgical guides were printed and used for fully guided implant placement. A total of 180 implants (60 per group) were placed, and scan bodies were positioned on all models, and postoperative surface scan files (STL) files were obtained. Superimposition of preoperative and postoperative STL files was performed, and the accuracy of implant position was evaluated. The interaction between group and implant location was statistically significant for angle, 3D offset at the base, and at the tip (P < .001). The post-hoc tests showed a statistically significantly higher deviation for group 2 compared to group 3 for all outcomes for implants #4 (P < .05) and #7 (P < .05). There was also a statistically significant difference in all outcomes between groups 1 and 3 for implant #7 (P < .05). All surgical guide designs presented satisfactory performance with clinically acceptable levels of deviation. However, SSGs presented higher accuracy for guided implant placement in a single-edentulous site, whereas a full-arch surgical guide with a crossbar presented superior outcomes when 2 or more guided implants were placed simultaneously.


Assuntos
Implantes Dentários , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional , Computadores
5.
J Am Assoc Lab Anim Sci ; 57(1): 13-17, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29402346

RESUMO

Capuchin monkeys are a species of arboreal primate found in all South American countries. These monkeys have been highlighted for their potential for biomedical research due to their anatomic and physiologic similarities and genetic homology with humans. Here we characterized the electrocardiographic tracings from 12 healthy, young capuchin monkeys that were restrained with ketamine and midazolam. All 12 monkeys had normal sinus rhythms. Neither P-wave duration, PR interval, QT interval, nor P- or R-wave amplitude (in millivolts) differed between males and females. The P waves were small, monophasic, and positive in all animals. The QRS complex showed positive polarity in the D1, D2, aVL, aVF, V2, V4, and V10 derivations and negative polarity in the D3, aVR, and rV2 leads. The T wave exhibited a negative polarity only in the aVR derivation in all animals in the study, and no significant difference was present between sexes. The ST segment was isoelectric in both sexes and lacked reductions and elevations. The anesthetic protocol was well tolerated all of the monkeys and allowed for diagnostic-quality acquisition, measurement, and characterization of the electrocardiogram and establishment of the normal electrocardiographic parameters of chemically restrained capuchin monkeys.


Assuntos
Cebus/fisiologia , Eletrocardiografia/veterinária , Coração/fisiologia , Animais , Feminino , Masculino , Valores de Referência , Especificidade da Espécie
6.
J Biomed Mater Res A ; 101(7): 1971-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23225833

RESUMO

The aim of the present study was to evaluate the effect of the placement of titanium granules in fresh extraction sockets on early bone formation. The mesial roots of the third maxillary premolars of five adult beagle dogs were removed. On one side of the maxilla (Test group) the fresh extraction socket was grafted with titanium granules, while the contra-lateral socket was left non-grafted (Control group). After 1 month of healing, the dogs were euthanized and biopsies were obtained. The healing tissues were described, and histometric measurements were performed to obtain the percentage area occupied by connective tissue, new mineralized bone, bone marrow, and biomaterial particles. After 1 month of healing the findings from the histological examination revealed the titanium graft to be well incorporated into the provisional connective tissue or newly formed woven bone. The histometric measurements showed, however, that less mineralized bone was formed in the Test group than in the Control group. The present study suggests that the use of titanium granules in fresh extraction sockets was conducive to new bone formation. The graft of titanium granules seems, however, to delay the early phase of the healing process.


Assuntos
Processo Alveolar/fisiologia , Consolidação da Fratura , Osteogênese/efeitos dos fármacos , Titânio , Processo Alveolar/anatomia & histologia , Animais , Bochecha/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/fisiologia , Cães , Tecido de Granulação/efeitos dos fármacos , Inflamação/patologia , Pós , Língua/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...