Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-19464208

RESUMO

The purpose of this study was to compare the accuracy of Root ZX II to locate the apical constriction with the display meter set at "0.5" and "1'"reading. Seventy single-rooted teeth were soaked in an alginate model and randomly distributed in 2 groups (n = 35). Measurements were taken following canal irrigation with 1% NaOCl. The length was established using a #20 K-file attached to the holder when the display indicator reached the marks "0.5" (group I) or "1" (group II), after the meter read "Apex." Then, the file was fixed in position and the teeth removed from the alginate. The apical portion of the root was shaved until the tip of the file could be seen, the distance to the apical constriction verified by means of a stereomicroscope and the measurements compared. Statistical analysis was performed by using Student t test with the null hypothesis set as 5%. The mean positions of the file tip relative to the apical constriction were -0.23 +/- 0.39 mm and -0.42 +/- 0.45 for groups I and II, respectively, with no statistical difference (P > .05). The accuracy was 90.5% and 83.78% for the Root ZX II "0.5" and "1" readings, respectively. It was concluded that the meter reading "1" of Root ZX II reduced the risk of working length overestimation.


Assuntos
Cavidade Pulpar/patologia , Odontometria/instrumentação , Preparo de Canal Radicular/instrumentação , Ápice Dentário/patologia , Eletrônica Médica/instrumentação , Eletrônica Médica/estatística & dados numéricos , Humanos , Teste de Materiais , Odontometria/estatística & dados numéricos , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/métodos , Hipoclorito de Sódio/uso terapêutico
2.
Artigo em Inglês | MEDLINE | ID: mdl-17320427

RESUMO

OBJECTIVE: To evaluate the subcutaneous biocompatibility of 2 root canal sealers. STUDY DESIGN: The subcutaneous implant technique recommended by the Fédération Dentaire International (FDI) was used to test Endométhasone and EndoREZ root canal sealers. These materials were placed in Teflon tubes, 1 mm in diameter and 10 mm in length, and implanted into 2 pockets created in the back of 40 Calomys callosus rodents, 20 for each material. Tissue biopsies were collected and histologically examined 15, 30, 60, and 90 days after the implantation procedure. The overall level of the inflammatory tissue response was graded as none, slight, moderate, or severe on the sealer-connective tissue interface at the opening ends of the tubes. The connective tissue response along the lateral wall outside of each tube served as a negative control. RESULTS: The tissue reaction to the Endométhasone diminished with time. The EndoREZ sealer was highly toxic during all experimental periods. CONCLUSION: Endométhasone root canal sealer presented biocompatibility within the analyzed periods, whereas EndoREZ showed no biocompatible behavior and caused late hypersensitive reaction.


Assuntos
Resinas Compostas/toxicidade , Dexametasona/toxicidade , Formaldeído/toxicidade , Hidrocortisona/toxicidade , Materiais Restauradores do Canal Radicular/toxicidade , Tela Subcutânea/efeitos dos fármacos , Timol/análogos & derivados , Animais , Arvicolinae , Combinação de Medicamentos , Reação a Corpo Estranho/induzido quimicamente , Hipersensibilidade Tardia/induzido quimicamente , Implantes Experimentais , Masculino , Teste de Materiais , Ratos , Timol/toxicidade