Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 41(18-19): 1641-1650, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32726462

RESUMO

This study describes an inexpensive and nonconventional soft-embossing protocol to produce microfluidic devices in poly(methyl methacrylate) (PMMA). The desirable microfluidic structure was photo-patterned in a poly(vinyl acetate) (PVAc) film deposited on glass substrate to produce a low-relief master. Then, this template was used to generate a high-relief pattern in stiffened PDMS by increasing of curing agent /monomer ratio (1:5) followed by thermal aging in a laboratory oven (200°C for 24 h). The stiffened PDMS masters were used to replicate microfluidic devices in PMMA based on soft embossing at 220-230°C and thermal sealing at 140°C. Both embossing and sealing stages were performed by using binder clips. The proposed protocol has ensured the replication of microfluidic devices in PMMA with great fidelity (>94%). Examples of MCE devices, droplet generator devices and spot test array were successfully demonstrated. For testing MCE devices, a mixture containing inorganic cations was selected as model and the achieved analytical performance did not reveal significant difference from commercial PMMA devices. Water droplets were successfully generated in an oil phase at rate of ca. 60 droplets/min (fixing the continuous phase flow rate at 100 µL/h) with size of ca. 322 ± 6 µm. Glucose colorimetric assay was performed on spot test devices and good detectability level (5 µmol/L) was achieved. The obtained results for two artificial serum samples revealed good agreement with the certified concentrations. Based on the fabrication simplicity and great analytical performance, the proposed soft-embossing protocol may emerge as promising approach for manufacturing PMMA devices.


Assuntos
Desenho de Equipamento/métodos , Dispositivos Lab-On-A-Chip , Procedimentos Analíticos em Microchip/métodos , Polimetil Metacrilato/química , Glicemia/análise , Colorimetria/instrumentação , Eletroforese/instrumentação , Temperatura Alta , Limite de Detecção , Modelos Lineares , Modelos Biológicos , Reprodutibilidade dos Testes
2.
Anal Chim Acta ; 1119: 1-10, 2020 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-32439048

RESUMO

This study reports, for the first time, the possibility to manufacture analytical devices on polyester substrates using a cutting printer. The protocol involves the design of a layout in a graphical software, the cut into polyester films and the lamination against one or multiple polyester films coated with a thermosensitive layer. The feasibility of the proposed approach was demonstrated through the fabrication of 96-microwell plates, 3D microfluidic mixing and distance-based microfluidic devices. The printer has enabled cutting microchannels wider than 300 µm on polyester films and a thickness of 250 µm. Urea and glucose assays were performed on microwell plates aiming for their quantification in artificial urine and serum samples. The presented results revealed good agreement with the expected values. The complexation reaction between Fe2+ and o-phenanthroline was selected as model to investigate the feasibility of the 3D mixing device. Absorbance measurements were recorded for the reaction product performed in both on and off-chip modes. Considering the achieved data, the on-chip mixing exhibited similar behavior when compared to off-chip reaction, thus demonstrating to be efficient to perform mixtures due to the turbulence generated inside three-dimensional channels. Lastly, a distance-based device was designed to detect H2O2 based on the displacement of a dye plug promoted by the oxygen generation using a copper-modified paper sheet. The distance-based peroxymeter revealed a linear behavior in the concentration range between 1 and 5% (v/v) and a LOD equal to 0.5% (65.2 mM). Based on the results herein reported, the proposed method represents a simple and alternative protocol to produce microdevices, using affordable and inexpensive raw materials, within 10 min, and at a cost lower than US$ 0.10 per unit.

3.
Anal Chem ; 90(20): 11949-11954, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30188682

RESUMO

This study describes the use of mass spectrometry imaging with matrix-assisted laser desorption/ionization (MALDI) and desorption electrospray ionization (DESI) to understand the color gradient generation commonly seen in microfluidic paper-based analytical devices (µPADs). The formation of color gradients significantly impacts assay sensitivity and reproducibility with µPADs but the mechanism for formation is poorly understood. The glucose enzymatic assay using potassium iodide (KI) as a chromogenic agent was selected to investigate the color gradient generated across a detection spot. Colorimetric measurements revealed that the relative standard deviation for the recorded pixel intensities ranged between 34 and 40%, compromising the analytical reliability. While a variety of hypotheses have been generated to explain this phenomenon, few studies have attempted to elucidate the mechanisms associated with its formation. Mass spectrometry imaging using MALDI and DESI was applied to understand the nonuniform color distribution on the detection zone. MALDI experiments were first explored to monitor the spatial distribution of the glucose oxidase and horseradish peroxidase mixture, before and after lateral flow assay with and without KI. MALDI(+)-TOF data revealed uniform enzyme distribution on the detection spots. On the other hand, after the complete assay DESI(-) measurements revealed a heterogeneous shape indicating the presence of iodide and triiodide ions at the zone edge. The reaction product (I3-) is transported by lateral flow toward the zone edge, generating the color gradient. Mass spectrometry imaging has been used for the first time to prove that color gradient forms as result of the mobility small molecules and not the enzyme distribution on µPAD surface.


Assuntos
Cor , Colorimetria , Glucose/análise , Técnicas Analíticas Microfluídicas , Papel , Aspergillus niger/enzimologia , Glucose/metabolismo , Glucose Oxidase/metabolismo , Imagem Óptica , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Propriedades de Superfície
4.
Anal Chim Acta ; 974: 63-68, 2017 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-28535882

RESUMO

Simple methods have been developed for fabricating microfluidic paper-based analytical devices (µPADs) but few of these devices can be used with organic solvents and/or aqueous solutions containing surfactants. This study describes a simple fabrication strategy for µPADs that uses readily available scholar glue to create the hydrophobic flow barriers that are resistant to surfactants and organic solvents. Microfluidic structures were defined by magnetic masks designed with either neodymium magnets or magnetic sheets to define the patter, and structures were created by spraying an aqueous solution of glue on the paper surface. The glue-coated paper was then exposed to UV/Vis light for cross-linking to maximize chemical resistance. Examples of microzone arrays and microfluidic devices are demonstrated. µPADs fabricated with scholar glue retained their barriers when used with surfactants, organic solvents, and strong/weak acids and bases unlike common wax-printed barriers. Paper microzones and microfluidic devices were successfully used for colorimetric assays of clinically relevant analytes commonly detected in urinalysis to demonstrate the low background of the barrier material and generally applicability to sensing. The proposed fabrication method is attractive for both its ability to be used with diverse chemistries and the low cost and simplicity of the materials and process.

5.
Electrophoresis ; 38(2): 250-257, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27377397

RESUMO

This study describes a simple, rapid, and cost-effective fabrication of PDMS electrophoresis microchips using poly(vinyl acetate) (PVAc) emulsion as photoresist master. High-relief microfluidic structures were defined on poly(vinyl acetate) previously deposited on printed circuit boards surfaces without cleanroom facilities and sophisticated instrumentation. After a UV exposure, channels with heights ranging from 30 to 140 µm were obtained by controlling the emulsion mass deposited on the master surface. The developing stage was performed using water rather than the organic solvents that are applied for conventional masks. The surface morphology was characterized by optical imaging, profilometry, and SEM. Based on the achieved results, the proposed method offers suitable reproducibility for the prototyping of electrophoresis microchips in PDMS. The feasibility of the resulting PDMS electrophoresis chips was successfully demonstrated with the separation of major inorganic cations within 100 s using a contactless conductivity detection system. The separation efficiencies ranged from ca. 67 900 to 125 600 plates/m. Due to the satisfactory performance and simplified instrumentation, we believe this fabrication protocol presents potential to be implemented in any chemical, biochemical, or biological laboratory.


Assuntos
Dimetilpolisiloxanos/química , Eletroforese em Microchip/instrumentação , Desenho de Equipamento/métodos , Nylons/química , Polivinil/química , Condutividade Elétrica
6.
Lab Chip ; 15(7): 1651-5, 2015 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-25686364

RESUMO

We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Papel , Eletricidade Estática , Desenho de Equipamento , Teste de Materiais , Sistemas Automatizados de Assistência Junto ao Leito , Polimetil Metacrilato , Politetrafluoretileno
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...