Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 28(3): 1832-1844, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33034788

RESUMO

BACKGROUND: Carcinoembryonic antigen is overexpressed in colorectal cancer (CRC), making it an optimal target for fluorescence imaging. A phase I/II study was designed to determine the optimal imaging dose of SGM-101 for intraoperative fluorescence imaging of primary and recurrent CRC. METHODS: Patients were included and received a single dose of SGM-101 at least 24 h before surgery. Patients who received routine anticancer therapy (i.e., radiotherapy or chemotherapy) also were eligible. A dedicated near-infrared imaging system was used for real-time fluorescence imaging during surgery. Safety assessments were performed and SGM-101 efficacy was evaluated per dose level to determine the most optimal imaging dose. RESULTS: Thirty-seven patients with CRC were included in the analysis. Fluorescence was visible in all primary and recurrent tumors. In seven patients, no fluorescence was seen; all were confirmed as pathological complete responses after neoadjuvant therapy. Two tumors showed false-positive fluorescence. In the 37 patients, a total of 97 lesions were excised. The highest mean intraoperative tumor-to-background ratio (TBR) of 1.9 (p = 0.019) was seen in the 10-mg dose. This dose showed a sensitivity of 96%, specificity of 63%, and negative predictive value of 94%. Nine patients (24%) had a surgical plan alteration based on fluorescence, with additional malignant lesions detected in six patients. CONCLUSIONS: The optimal imaging dose was established at 10 mg 4 days before surgery. The results accentuate the potential of SGM-101 and designated a promising base for the multinational phase III study, which enrolled the first patients in June 2019.


Assuntos
Neoplasias Colorretais , Idoso , Antígeno Carcinoembrionário , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Óptica
2.
Eur J Surg Oncol ; 47(3 Pt B): 667-673, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33158638

RESUMO

BACKGROUND: Fluorescence-guided surgery can provide surgeons with an imaging tool for real-time intraoperative tumor detection. SGM-101, an anti-CEA antibody labelled with a fluorescent dye, is a tumor-specific imaging agent that can aid in improving detection and complete resection for CEA-positive tumors. In this study, the performance of SGM-101 for the detection of colorectal and pancreatic liver metastases was investigated. METHODS: In this open-label, non-randomized, single-arm pilot study, patients were included with liver metastases from colorectal origin and intraoperatively detected liver metastases from pancreatic origin (during planned pancreatic surgery). SGM-101 was administered two to four days before the scheduled surgery as a single intravenous injection. Intraoperative fluorescence imaging was performed using the Quest Spectrum® imaging system. The performance of SGM-101 was assessed by measuring the intraoperative fluorescence signal and comparing this to histopathology. RESULTS: A total of 19 lesions were found in 11 patients, which were all suspected as malignant in white light and subsequent fluorescence inspection. Seventeen lesions were malignant with a mean tumor-to-background ratio of 1.7. The remaining two lesions were false-positives as proven by histology. CONCLUSION: CEA-targeted fluorescence-guided intraoperative tumor detection with SGM-101 is feasible for the detection of colorectal and pancreatic liver metastases.


Assuntos
Adenocarcinoma/secundário , Antígeno Carcinoembrionário/metabolismo , Neoplasias Colorretais/patologia , Imunofluorescência/métodos , Neoplasias Hepáticas/secundário , Imagem Molecular/métodos , Imagem Óptica/métodos , Neoplasias Pancreáticas/patologia , Adenocarcinoma/diagnóstico , Adenocarcinoma/metabolismo , Adulto , Idoso , Anticorpos Monoclonais , Antígeno Carcinoembrionário/imunologia , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/cirurgia , Feminino , Corantes Fluorescentes , Humanos , Período Intraoperatório , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/cirurgia , Projetos Piloto
3.
Gynecol Oncol ; 159(3): 672-680, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33041071

RESUMO

OBJECTIVE: The aim of this study was to assess the superiority of ICG-99mTc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients compared to standard SLN detection using 99mTc-nanocolloid with blue dye. METHODS: In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99mTc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications. RESULTS: Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99mTc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041). CONCLUSIONS: Intraoperative visual detection of SLNs in patients with VSCC using ICG-99mTc-nanocolloid was superior compared to 99mTc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualization. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register (Trial ID NL7443).


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Cuidados Intraoperatórios/métodos , Metástase Linfática/diagnóstico , Linfonodo Sentinela/diagnóstico por imagem , Neoplasias Vulvares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/secundário , Carcinoma de Células Escamosas/cirurgia , Corantes/administração & dosagem , Feminino , Humanos , Excisão de Linfonodo , Metástase Linfática/terapia , Pessoa de Meia-Idade , Países Baixos , Duração da Cirurgia , Imagem Óptica/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Fatores de Tempo , Neoplasias Vulvares/patologia , Vulvectomia
4.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345649

RESUMO

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade Aguda
5.
Nat Commun ; 10(1): 3118, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31311922

RESUMO

Iatrogenic injury of the ureters is a feared complication of abdominal surgery. Zwitterionic near-infrared fluorophores are molecules with geometrically-balanced, electrically-neutral surface charge, which leads to renal-exclusive clearance and ultralow non-specific background binding. Such molecules could solve the ureter mapping problem by providing real-time anatomic and functional imaging, even through intact peritoneum. Here we present the first-in-human experience of this chemical class, as well as the efficacy study in patients undergoing laparoscopic abdominopelvic surgery. The zwitterionic near-infrared fluorophore ZW800-1 is safe, has pharmacokinetic properties consistent with an ideal blood pool agent, and rapid elimination into urine after a single low-dose intravenous injection. Visualization of structure and function of the ureters starts within minutes after ZW800-1 injection and lasts several hours. Zwitterionic near-infrared fluorophores add value during laparoscopic abdominopelvic surgeries and could potentially decrease iatrogenic urethral injury. Moreover, ZW800-1 is engineered for one-step covalent conjugatability, creating possibilities for developing novel targeted ligands.


Assuntos
Complicações Intraoperatórias/prevenção & controle , Laparoscopia/efeitos adversos , Compostos de Amônio Quaternário/administração & dosagem , Ácidos Sulfônicos/administração & dosagem , Ureter/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Corantes Fluorescentes/administração & dosagem , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Infusões Intravenosas , Complicações Intraoperatórias/etiologia , Ionóforos/administração & dosagem , Ionóforos/efeitos adversos , Ionóforos/farmacocinética , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Imagem Óptica/métodos , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/farmacocinética , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/farmacocinética , Ureter/lesões , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...