Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35138350

RESUMO

OBJECTIVES: There are disparities in the adherence to guideline-recommended therapies after coronary artery bypass graft (CABG). We therefore sought to evaluate the effect of guideline-adherent medical secondary prevention on 1-year outcome after CABG. METHODS: Data were taken from the randomized 'Ticagrelor in CABG' trial. From April 2013 until April 2017, patients who underwent CABG were included. For the present analysis, we compared patients who were treated with optimal medical secondary prevention with those where 1 or more of the recommended medications were missing. RESULTS: Follow-up data at 12 months were available in 1807 patients. About half (54%) of them were treated with optimal secondary prevention. All-cause mortality [0.5% vs 3.5%, hazard ratio (HR) 0.14 (0.05-0.37), P < 0.01], cardiovascular mortality [0.1% vs 1.7%, HR 0.06 (0.01-0.46), P = 0.007] and major adverse events [6.5% vs 11.5%, HR 0.54 (0.39-0.74), P < 0.01] were significantly lower in the group with optimal secondary prevention. The multivariable model for the primary end point based on binary concordance to guideline recommended therapy identified 3 independent factors: adherence to guideline recommended therapy [HR 0.55 (0.39-0.78), P < 0.001]; normal renal function [HR 0.99 (0.98-0.99), P = 0.040]; and off-pump surgery [HR 2.06 (1.02-4.18), P = 0.045]. CONCLUSIONS: Only every second patient receives optimal secondary prevention after CABG. Guideline adherent secondary prevention therapy is associated with lower mid-term mortality and less adverse cardiovascular events after 12 months.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Humanos , Prognóstico , Prevenção Secundária , Ticagrelor , Resultado do Tratamento
2.
Am J Cardiol ; 141: 7-15, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33220322

RESUMO

The impact of the anatomic characteristics of coronary stenoses on the development of future coronary thrombosis has been controversial. This study aimed at identifying the anatomic and flow characteristics of left anterior descending (LAD) coronary artery stenoses that predispose to myocardial infarction, by examining angiograms obtained before the index event. We identified 90 patients with anterior ST-elevation myocardial infarction (STEMI) for whom coronary angiograms and their reconstruction in the three-dimensional space were available at 6 to 12 months before the STEMI, and at the revascularization procedure. The majority of culprit lesions responsible for STEMI occurred between 20 and 40 mm from the LAD ostium, whereas the majority of stable lesions not associated with STEMI were found in distances >60 mm (p < 0.001). Culprit lesions were significantly more stenosed (diameter stenosis 68.6 ± 14.2% vs 44.0 ± 10.4%, p < 0.001), and significantly longer than stable ones (15.3 ± 5.4 mm vs 9.2 ± 2.5 mm, p < 0.001). Bifurcations at culprit lesions were significantly more frequent (88.8%) compared with stable lesions (34.4%, p < 0.001). Computational fluid dynamics simulations demonstrated that hemodynamic conditions in the vicinity of culprit lesions promote coronary thrombosis due to flow recirculation. A multiple logistic regression model with diameter stenosis, lesion length, distance from the LAD ostium, distance from bifurcation, and lesion symmetry, showed excellent accuracy in predicting the development of a culprit lesion (AUC: 0.993 [95% CI: 0.969 to 1.000], p < 0.0001). In conclusion, specific anatomic and hemodynamic characteristics of LAD stenoses identified on coronary angiograms may assist risk stratification of patients by predicting sites of future myocardial infarction.


Assuntos
Estenose Coronária/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Hemodinâmica , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Idoso , Angiografia Coronária , Estenose Coronária/complicações , Estenose Coronária/fisiopatologia , Trombose Coronária/etiologia , Trombose Coronária/fisiopatologia , Trombose Coronária/cirurgia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Revascularização Miocárdica , Modelagem Computacional Específica para o Paciente , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Índice de Gravidade de Doença
3.
Eur Heart J ; 40(29): 2432-2440, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31145798

RESUMO

AIMS: The antiplatelet treatment strategy providing optimal balance between thrombotic and bleeding risks in patients undergoing coronary artery bypass grafting (CABG) is unclear. We prospectively compared the efficacy of ticagrelor and aspirin after CABG. METHODS AND RESULTS: We randomly assigned in double-blind fashion patients scheduled for CABG to either ticagrelor 90 mg twice daily or 100 mg aspirin (1:1) once daily. The primary outcome was the composite of cardiovascular death, myocardial infarction (MI), repeat revascularization, and stroke 12 months after CABG. The main safety endpoint was based on the Bleeding Academic Research Consortium classification, defined as BARC ≥4 for periprocedural and hospital stay-related bleedings and BARC ≥3 for post-discharge bleedings. The study was prematurely halted after recruitment of 1859 out of 3850 planned patients. Twelve months after CABG, the primary endpoint occurred in 86 out of 931 patients (9.7%) in the ticagrelor group and in 73 out of 928 patients (8.2%) in the aspirin group [hazard ratio 1.19; 95% confidence interval (CI) 0.87-1.62; P = 0.28]. All-cause mortality (ticagrelor 2.5% vs. aspirin 2.6%, hazard ratio 0.96, CI 0.53-1.72; P = 0.89), cardiovascular death (ticagrelor 1.2% vs. aspirin 1.4%, hazard ratio 0.85, CI 0.38-1.89; P = 0.68), MI (ticagrelor 2.1% vs. aspirin 3.4%, hazard ratio 0.63, CI 0.36-1.12, P = 0.12), and stroke (ticagrelor 3.1% vs. 2.6%, hazard ratio 1.21, CI 0.70-2.08; P = 0.49), showed no significant difference between the ticagrelor and aspirin group. The main safety endpoint was also not significantly different (ticagrelor 3.7% vs. aspirin 3.2%, hazard ratio 1.17, CI 0.71-1.92; P = 0.53). CONCLUSION: In this prematurely terminated and thus underpowered randomized trial of ticagrelor vs. aspirin in patients after CABG no significant differences in major cardiovascular events or major bleeding could be demonstrated. CLINICALTRIALS.GOV IDENTIFIER: NCT01755520.


Assuntos
Aspirina/uso terapêutico , Ponte de Artéria Coronária/métodos , Inibidores da Agregação Plaquetária/uso terapêutico , Ticagrelor/uso terapêutico , Idoso , Método Duplo-Cego , Término Precoce de Ensaios Clínicos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/prevenção & controle , Hemorragia Pós-Operatória/induzido quimicamente , Hemorragia Pós-Operatória/epidemiologia , Resultado do Tratamento
4.
EuroIntervention ; 13(8): 986-993, 2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-28067198

RESUMO

AIMS: The durable polymer platinum-chromium everolimus-eluting stent (PtCr-EES) is a new-generation drug-eluting stent (DES) with a platinum-enriched metallic platform developed to improve the percutaneous treatment of patients with coronary artery disease. We sought to investigate the performance of durable polymer PtCr-EES versus other new-generation DES. METHODS AND RESULTS: We undertook a meta-analysis of trials in which patients receiving percutaneous coronary intervention (PCI) were randomly assigned to durable polymer PtCr-EES versus other new-generation DES (other DES). Primary efficacy and safety outcomes were target lesion revascularisation (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were myocardial infarction (MI), target vessel revascularisation (TVR), death, cardiac death and longitudinal stent deformation (LSD). A total of 11,036 patients in seven trials received a PCI with either durable polymer PtCr-EES (n=6,613) or other DES (n=4,423). This latter group comprised patients treated with biolimus- (n=325), cobalt-chromium everolimus- (n=1,940) or zotarolimus-eluting stents (n=2,158). After a median follow-up of 12 months (interquartile range 12-24), durable polymer PtCr-EES displayed a risk of TLR (odds ratio 0.98, 95% confidence interval [CI]: 0.75-1.29; p=0.90) and definite/probable ST (0.89 [0.55-1.45]; p=0.63) comparable to that of other DES. However, the durable polymer PtCr-EES was associated with a higher risk of LSD (12.05 [1.60-90.71], p=0.02) compared to other DES. There was no significant difference with regard to other secondary outcomes nor was there heterogeneity across trials. CONCLUSIONS: At one-year follow-up, the durable polymer PtCr-EES displays a performance comparable to that of other new-generation DES platforms.


Assuntos
Cromo/uso terapêutico , Stents Farmacológicos , Everolimo/uso terapêutico , Intervenção Coronária Percutânea , Platina/uso terapêutico , Polímeros/uso terapêutico , Idoso , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
5.
Am Heart J ; 179: 69-76, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27595681

RESUMO

BACKGROUND: For patients with coronary artery disease undergoing coronary bypass surgery, acetylsalicylic acid (ASA) currently represents the gold standard of antiplatelet treatment. However, adverse cardiovascular event rates in the first year after coronary artery bypass grafting (CABG) still exceed 10%. Graft failure, which is predominantly mediated by platelet aggregation, has been identified as a major contributing factor in this context. Therefore, intensified platelet inhibition is likely to be beneficial. Ticagrelor, an oral, reversibly binding and direct-acting P2Y12 receptor antagonist, provides a rapid, competent, and consistent platelet inhibition and has shown beneficial results compared with clopidogrel in the subset of patients undergoing bypass surgery in a large previous trial. HYPOTHESIS: Ticagrelor is superior to ASA for the prevention of major cardiovascular events within 1 year after CABG. STUDY DESIGN: The TiCAB trial (NCT01755520) is a multicenter, phase III, double-blind, double-dummy, randomized trial comparing ticagrelor with ASA for the prevention of major cardiovascular events within 12 months after CABG. Patients undergoing CABG will be randomized in a 1:1 fashion to either ticagrelor 90 mg twice daily or ASA 100 mg once daily. The study medication will be started within 24 hours after surgery and maintained for 12 months. The primary end point is the composite of cardiovascular death, myocardial infarction, stroke, and repeat revascularization at 12 months after CABG. The sample size is based on an expected event rate of 13% of the primary end point within the first 12 months after randomization in the control group, a 2-sided α level of .0492 (to preserve the overall significance level of .05 after planned interim analysis), a power of 0.80%, 2-sided testing, and an expected relative risk of 0.775 in the active group compared with the control group and a dropout rate of 2%. According to power calculations based on a superiority design for ticagrelor, it is estimated that 3,850 patients should be enrolled. SUMMARY: There is clinical equipoise on the issue of optimal platelet inhibition after CABG. The TiCAB trial will provide a pivotal comparison of the efficacy and safety of ticagrelor compared with ASA after CABG.


Assuntos
Adenosina/análogos & derivados , Aspirina/uso terapêutico , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Adenosina/uso terapêutico , Idoso , Doenças Cardiovasculares/mortalidade , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Acidente Vascular Cerebral/epidemiologia , Ticagrelor , Resultado do Tratamento
6.
Clin Res Cardiol ; 105(12): 1030-1041, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27378612

RESUMO

BACKGROUND: In myocardial infarction without cardiogenic shock (CS), the affected coronary vessel has significant influence on the final infarct size and patient prognosis. CS data on this relation are scarce. The objective of this study was to determine the prognostic relevance of the culprit lesion location in patients with CS complicating acute myocardial infarction. METHODS: In the Intraaortic Balloon Pump in Cardiogenic Shock II (IABP-SHOCK II) trial patients with CS were randomized to therapy with intraaortic balloon pump or control. Additional CS patients not eligible for the randomized trial were included in a registry. We compared the location of the culprit lesions in these patients with regard to the affected coronary vessel [left main (LM), left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA)] and location within the vessel (proximal, mid or distal) regarding short- and long-term outcome. RESULTS: Of 758 patients, the majority had the culprit lesion in the LAD (44 %) compared to RCA (27 %), LCX (19 %) or LM (10 %). Proximal lesions were more frequent than mid or distal culprit lesions (60 vs. 27 vs. 13 %, p < 0.001). No differences were observed for mortality with respect to either culprit vessel (log-rank p value = 0.54). In contrast, a higher mortality was observed for patients with distal culprit lesions after 1 year (log-rank p value = 0.04). This difference persisted after multivariable adjustment (hazard ratio for distal lesions 1.40; 95 % confidential interval 1.03-1.90; p = 0.03). CONCLUSION: For patients with CS complicating myocardial infarction, the culprit vessel seems to be unrelated with mortality whereas distal culprit lesions may have a worse outcome.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Balão Intra-Aórtico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Choque Cardiogênico/terapia , Idoso , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/mortalidade , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Fatores de Tempo , Resultado do Tratamento
7.
Cochrane Database Syst Rev ; (3): CD007398, 2015 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-25812932

RESUMO

BACKGROUND: Intra-aortic balloon pump counterpulsation (IABP) is currently the most commonly used mechanical assist device for patients with cardiogenic shock due to acute myocardial infarction. Although there has been only limited evidence from randomised controlled trials, the previous guidelines of the American Heart Association/American College of Cardiology (AHA/ACC) and the European Society of Cardiology (ESC) strongly recommended the use of the IABP in patients with infarction-related cardiogenic shock on the basis of pathophysiological considerations, non-randomised trials and registry data. The recent guidelines downgraded the recommendation based on a meta-analysis which could only include non-randomised trials showing conflicting results. Up to now, there have been no guideline recommendations and no actual meta-analysis including the results of the large randomised multicentre IABP-SHOCK II Trial which showed no survival benefit with IABP support. This systematic review is an update of the review published in 2011. OBJECTIVES: To evaluate, in terms of efficacy and safety, the effect of IABP versus non-IABP or other assist devices guideline compliant standard therapy on mortality and morbidity in patients with acute myocardial infarction complicated by cardiogenic shock. SEARCH METHODS: Searches of CENTRAL, MEDLINE (Ovid) and EMBASE (Ovid), LILACS, IndMed and KoreaMed, registers of ongoing trials and proceedings of conferences were updated in October 2013. Reference lists were scanned and experts in the field contacted to obtain further information. No language restrictions were applied. SELECTION CRITERIA: Randomised controlled trials on patients with acute myocardial infarction complicated by cardiogenic shock. DATA COLLECTION AND ANALYSIS: Data collection and analysis were performed according to the published protocol. Individual patient data were provided for six trials and merged with aggregate data. Summary statistics for the primary endpoints were hazard ratios (HRs) and odds ratios (ORs) with 95% confidence intervals (CIs). MAIN RESULTS: Seven eligible studies were identified from a total of 2314 references. One new study with 600 patients was added to the original review. Four trials compared IABP to standard treatment and three to other percutaneous left assist devices (LVAD). Data from a total of 790 patients with acute myocardial infarction and cardiogenic shock were included in the updated meta-analysis: 406 patients were treated with IABP and 384 patients served as controls; 339 patients were treated without assisting devices and 45 patients with other LVAD. The HR for all-cause 30-day mortality of 0.95 (95% CI 0.76 to 1.19) provided no evidence for a survival benefit. Different non-fatal cardiovascular events were reported in five trials. During hospitalisation, 11 and 4 out of 364 patients from the intervention groups suffered from reinfarction or stroke, respectively. Altogether 5 out of 363 patients from the control group suffered from reinfarction or stroke. Reocclusion was treated with subsequent re-revascularization in 6 out of 352 patients from the intervention group and 13 out of 353 patients of the control group. The high incidence of complications such as moderate and severe bleeding or infection in the control groups has to be attributed to interventions with other LVAD. Possible reasons for bias were more frequent in small studies with high cross-over rates, early stopping and the inclusion of patients with IABP at randomisation. AUTHORS' CONCLUSIONS: Available evidence suggests that IABP may have a beneficial effect on some haemodynamic parameters. However, this did not result in survival benefits so there is no convincing randomised data to support the use of IABP in infarct-related cardiogenic shock.


Assuntos
Balão Intra-Aórtico/métodos , Infarto do Miocárdio/complicações , Choque Cardiogênico/terapia , Circulação Assistida/instrumentação , Circulação Assistida/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Choque Cardiogênico/etiologia
8.
EuroIntervention ; 10(12): 1425-31, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24602961

RESUMO

AIMS: Arterial plaque rupture and thrombus characterise ST-elevation myocardial infarction (STEMI) and may aggravate delayed arterial healing following durable polymer drug-eluting stent (DP-DES) implantation. Biodegradable polymer (BP) may improve biocompatibility. We compared long-term outcomes in STEMI patients receiving BP-DES vs. durable polymer sirolimus-eluting stents (DP-SES). METHODS AND RESULTS: We pooled individual patient-level data from three randomised clinical trials (ISAR-TEST-3, ISAR-TEST-4 and LEADERS) comparing outcomes from BP-DES with DP-SES at four years. The primary endpoint (MACE) comprised cardiac death, MI, or target lesion revascularisation (TLR). Secondary endpoints were TLR, cardiac death or MI, and definite or probable stent thrombosis. Of 497 patients with STEMI, 291 received BP-DES and 206 DP-SES. At four years, MACE was significantly reduced following treatment with BP-DES (hazard ratio [HR] 0.59, 95% CI: 0.39-0.90; p=0.01) driven by reduced TLR (HR 0.54, 95% CI: 0.30-0.98; p=0.04). Trends towards reduction were seen for cardiac death or MI (HR 0.63, 95% CI: 0.37-1.05; p=0.07) and definite or probable stent thrombosis (3.6% vs. 7.1%; HR 0.49, 95% CI: 0.22-1.11; p=0.09). CONCLUSIONS: In STEMI, BP-DES demonstrated superior clinical outcomes to DP-SES at four years. Trends towards reduced cardiac death or myocardial infarction and reduced stent thrombosis require corroboration in specifically powered trials.


Assuntos
Implantes Absorvíveis , Antibióticos Antineoplásicos/uso terapêutico , Estenose Coronária/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Trombose/terapia , Idoso , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Trombose/epidemiologia , Resultado do Tratamento
9.
Clin Res Cardiol ; 104(1): 71-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25287767

RESUMO

BACKGROUND: Cardiogenic shock (CS) complicating acute myocardial infarction (AMI) is associated with high mortality. Previous studies regarding gender-specific differences in CS are conflicting and there are insufficient data for the presence of gender-associated differences in the contemporary percutaneous coronary intervention era. Aim of this study was therefore to investigate gender-specific differences in a large cohort of AMI patients with CS undergoing contemporary treatment. METHODS: In the randomized Intra-aortic Balloon Pump in Cardiogenic Shock II (IABP-SHOCK II) trial, 600 patients with CS complicating AMI undergoing early revascularization were assigned to therapy with or without intra-aortic balloon pump. We compared sex-specific differences in these patients with regard to baseline and procedural characteristics as well as short- and long-term clinical outcome. RESULTS: Of 600 patients 187 (31%) were female. Women were significantly older than men and had a significantly lower systolic and diastolic blood pressure at presentation (p < 0.05 for all). Diabetes mellitus and hypertension were more frequent in women, whereas smoking was more frequent in men (p < 0.05 for all). Women showed a higher mortality within the first day after randomization (p = 0.004). However, after multivariable adjustment this numerical difference was no longer statistically significant. No gender-related differences in clinical outcome were observed after 1, 6 and 12 months of follow-up. CONCLUSION: In this large-scale multicenter study in patients with CS complicating AMI, women had a worse-risk profile in comparison to men. No significant gender-related differences in treatment as well as short- and long-term outcome were observed.


Assuntos
Ponte de Artéria Coronária , Balão Intra-Aórtico , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Feminino , Alemanha , Humanos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/mortalidade , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Medição de Risco , Fatores de Risco , Fatores Sexuais , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 15(2): 69-75, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24684757

RESUMO

BACKGROUND: Concern exists relating to potential attenuated efficacy of limus-eluting stents in patients with diabetes mellitus. In this respect diabetic patients with sirolimus-eluting stent (SES) failure requiring reintervention may be expected to derive particular benefit from a treatment-switch to paclitaxel-eluting stent (PES) implantation. OBJECTIVE: The aim of the current report was to investigate outcomes of patients with SES restenosis randomized to treatment with SES (same stent strategy) or PES (switch stent strategy) in the pre-specified subgroups of patients with and without diabetes mellitus. METHODS: In the setting of ISAR-DESIRE 2 trial, 450 patients with clinically significant SES restenosis were randomly assigned to receive either SES or PES. The primary end point was in-stent late loss at 6-8month follow-up angiography. Secondary endpoints were binary angiographic restenosis (diameter stenosis >50%) and target lesion revascularization (TLR), the composite of death or myocardial infarction (MI) and definite stent thrombosis at 12months. RESULTS: Of 450 patients enrolled, 162 (36.0%) had a diagnosis of diabetes mellitus. In patients with diabetes 86 patients were randomly assigned to SES versus 76 to PES. In patients without diabetes 139 were assigned to SES versus 149 to PES. Late loss was comparable between SES and PES both in patients with diabetes (0.38±0.59mm vs. 0.37±0.59mm; p=0.97) and without (0.41±0.67mm vs. 0.38±0.6mm; p=0.98; pinteraction=0.89). Similarly binary restenosis was comparable between SES and PES in patients with diabetes (19.0% vs. 26.0%; p=0.32) or without (18.9% vs. 17.8%; p=0.98; pinteraction=0.36). TLR, death or MI and definite stent thrombosis were also similar in SES versus PES treatment groups regardless of diabetes status. CONCLUSIONS: In cases of SES-restenosis, treatment with either repeat SES or switch to PES was associated with a comparable degree of efficacy, regardless of diabetic status.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Reestenose Coronária/terapia , Complicações do Diabetes/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Trombose Coronária/etiologia , Complicações do Diabetes/diagnóstico , Complicações do Diabetes/etiologia , Complicações do Diabetes/mortalidade , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Lancet ; 382(9905): 1638-45, 2013 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-24011548

RESUMO

BACKGROUND: In current international guidelines the recommendation for intra-aortic balloon pump (IABP) use has been downgraded in cardiogenic shock complicating acute myocardial infarction on the basis of registry data. In the largest randomised trial (IABP-SHOCK II), IABP support did not reduce 30 day mortality compared with control. However, previous trials in cardiogenic shock showed a mortality benefit only at extended follow-up. The present analysis therefore reports 6 and 12 month results. METHODS: The IABP-SHOCK II trial was a randomised, open-label, multicentre trial. Patients with cardiogenic shock complicating acute myocardial infarction who were undergoing early revascularisation and optimum medical therapy were randomly assigned (1:1) to IABP versus control via a central web-based system. The primary efficacy endpoint was 30 day all-cause mortality, but 6 and 12 month follow-up was done in addition to quality-of-life assessment for all survivors with the Euroqol-5D questionnaire. A masked central committee adjudicated clinical outcomes. Patients and investigators were not masked to treatment allocation. Analysis was by intention to treat. This trial is registered at ClinicalTrials.gov, NCT00491036. FINDINGS: Between June 16, 2009, and March 3, 2012, 600 patients were assigned to IABP (n=301) or control (n=299). Of 595 patients completing 12 month follow-up, 155 (52%) of 299 patients in the IABP group and 152 (51%) of 296 patients in the control group had died (relative risk [RR] 1·01, 95% CI 0·86-1·18, p=0·91). There were no significant differences in reinfarction (RR 2·60, 95% CI 0·95-7·10, p=0·05), recurrent revascularisation (0·91, 0·58-1·41, p=0·77), or stroke (1·50, 0·25-8·84, p=1·00). For survivors, quality-of-life measures including mobility, self-care, usual activities, pain or discomfort, and anxiety or depression did not differ significantly between study groups. INTERPRETATION: In patients undergoing early revascularisation for myocardial infarction complicated by cardiogenic shock, IABP did not reduce 12 month all-cause mortality. FUNDING: German Research Foundation; German Heart Research Foundation; German Cardiac Society; Arbeitsgemeinschaft Leitende Kardiologische Krankenhausärzte; University of Leipzig--Heart Centre; Maquet Cardiopulmonary; Teleflex Medical.


Assuntos
Balão Intra-Aórtico/mortalidade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Choque Cardiogênico/complicações , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Revascularização Miocárdica , Qualidade de Vida , Fatores de Risco , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
12.
Int J Cardiol ; 168(6): 5162-6, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23993323

RESUMO

BACKGROUND: There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS: We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4 years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis. RESULTS: Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4 years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio = 0.95, 95% CI = 0.74-1.21, P = 0.67). Target lesion revascularization was also comparable between the groups (hazard ratio = 0.89, 95% CI = 0.65-1.22, P = 0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio = 0.52, 95% CI = 0.28-0.96, P = 0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4 years (hazard ratio = 0.15, 95% CI = 0.03-0.70, P = 0.02). CONCLUSIONS: In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4 years. Rates of stent thrombosis were significantly lower with BP-DES.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Polímeros , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Complicações do Diabetes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Resultado do Tratamento
13.
Am Heart J ; 164(1): 58-65.e1, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22795283

RESUMO

BACKGROUND: Conflicting data on intra-aortic balloon counterpulsation (IABC) as adjunctive therapy in high-risk acute myocardial infarction (AMI) without cardiogenic shock (CS) have been published. We performed a meta-analysis of randomized trials evaluating the benefits of IABC in patients with AMI without CS. METHODS: We searched Medline, EMBASE, the Cochrane Central Register of Controlled Trials, and relevant Web sites for randomized trials comparing IABC versus no IABC in patients with AMI without CS. No language, publication date, or publication status restrictions were applied. Primary end point was all-cause death. Secondary end points were congestive heart failure (CHF), reinfarction, recurrent myocardial ischemia, cerebrovascular accidents (CVA), and bleeding (moderate to severe) according to per protocol definitions. RESULTS: Six trials were included (1,054 patients, 49.1% IABC vs 50.9% no IABC). At follow-up, counterpulsation does not reduce all-cause death (4.4% vs 4.1%, odds ratio [OR] [95% CI] 1.11 [0.49-2.54], P = .80), CHF (17.1% vs 18%, OR 0.92 [0.43-1.96], P = .83), or reinfarction (5.3% vs 7.7%, OR 0.68 [0.23-1.76], P = .42). Intra-aortic balloon counterpulsation versus no IABC significantly reduces recurrent myocardial ischemia (3.6% vs 20.3%, OR 0.15 [0.08-0.28], P < .00001), but it increases the risk of CVA (2% vs 0.3%, OR 4.39 [1.11-17.36], P = .03) and bleeding (21.4% vs 16.1%, respectively, OR 1.46 [1.05-2.04], P = .02). CONCLUSIONS: Counterpulsation does not reduce death, CHF, or reinfarction in patients with AMI without CS. The significant reduction of recurrent myocardial ischemia associated with IABC use is offset by a higher risk of CVAs and bleeding.


Assuntos
Balão Intra-Aórtico , Infarto do Miocárdio/terapia , Contrapulsação , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Choque Cardiogênico
14.
Circ Cardiovasc Interv ; 5(3): 357-64, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22668554

RESUMO

BACKGROUND: Some but not all studies have reported reduced rates of stent thrombosis (ST) with everolimus-eluting stents (EES) compared with other drug-eluting stents (DES). All of these studies were insufficiently powered to reliably detect differences in ST. We therefore performed a meta-analysis of randomized controlled trials comparing the risk of 2-year definite ST between EES and other DES. METHODS AND RESULTS: Randomized controlled trials comparing EES versus other DES were searched through MEDLINE, EMBASE, Cochrane databases, and proceedings of international meetings. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. Eleven randomized controlled trials (16,775 patients) were analyzed, including 5 trials (n=7113) of EES versus paclitaxel-eluting stents, 5 trials (n=7370) of EES versus sirolimus-eluting stents, and 1 trial (n=2292) of EES versus zotarolimus-eluting stents. By 2 years definite ST with EES compared with pooled DES occurred in 0.5% versus 1.3% patients, respectively (relative risk, 0.38; 95% CI, 0.24-0.59; P<0.0001). Similar results were observed when the broader definition of definite/probable ST was considered (relative risk, 0.46; 95% CI, 0.33-0.66; P<0.0001). EES compared with other DES reduced the relative risk of early ST (within 30 days), late ST (31 days to 1 year), cumulative 1-year ST, and very late ST (1-2 years). The reduced rate of definite ST observed with EES was consistent across all DES comparators with no interactions apparent during any time interval. CONCLUSIONS: EES compared with a pooled group of paclitaxel-eluting stents, sirolimus-eluting stents, and zotarolimus-eluting stents is associated with a significant reduction of definite ST, an effect that appears early and increases in magnitude through at least 2 years.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Trombose Coronária/prevenção & controle , Stents Farmacológicos , Sirolimo/análogos & derivados , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Everolimo , Medicina Baseada em Evidências , Humanos , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Razão de Chances , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
15.
Ther Adv Cardiovasc Dis ; 6(3): 123-32, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22569335

RESUMO

Intraaortic balloon pump (IABP) is the most widely used left ventricular support device in a variety of indications. This review focuses on the current literature and discusses the evidence of IABP in ST-elevation myocardial infarction (STEMI) with and without cardiogenic shock. In high-risk STEMI patients without cardiogenic shock several randomized clinical trials have been performed. The majority of the studies could not demonstrate an efficacy benefit for IABP as adjunctive therapy in comparison to standard treatment alone. Hence, recent meta-analyses could not reveal diverging mortality rates at a higher incidence of stroke and major bleedings with IABP use independent of the type of reperfusion therapy. IABP in STEMI patients with cardiogenic shock is recommended according to current American College of Cardiology/American Heart Association (AHA/ACC) and European Society of Cardiology (ESC) guidelines. In recent meta-analyses, IABP in cardiogenic shock complicated by STEMI has been shown to be associated with decreased mortality. However, these beneficial effects are limited to patients treated with thrombolysis, whereas in patients undergoing mechanical revascularization IABP therapy is associated with an increase in mortality. Nevertheless, these data only arise from prospective and retrospective cohort studies, as up to date only one very small randomized clinical trial has been completed. In summary, in high-risk STEMI patients without cardiogenic shock, current data do not support the use of IABP and should only be considered as a standby and bailout strategy if patients develop haemodynamic instability. Current data on IABP in patients with cardiogenic shock complicated by STEMI are scarce and highly limited due to the nonrandomized design of previous trials. However, according to current AHA/ACC and ESC guidelines its use is recommended. Although recent meta-analyses challenge current AHA/ACC/ESC guidelines, adequately powered randomized studies are needed to elucidate the role of IABP in patients with acute myocardial infarction complicated by cardiogenic shock.


Assuntos
Balão Intra-Aórtico , Infarto do Miocárdio/terapia , Choque Cardiogênico/terapia , Angioplastia Coronária com Balão , Humanos , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Terapia Trombolítica
16.
Knee Surg Sports Traumatol Arthrosc ; 20(11): 2148-55, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22527418

RESUMO

For many years, coracoid impingement has been a well-recognized cause of anterior shoulder pain. However, a precise diagnosis of coracoid impingement remains difficult in some cases due to the presence of multifactorial pathologies and a paucity of supporting evidence in the literature. This review provides an update on the current anatomical and biomechanical knowledge regarding this pathology, describes the diagnostic process, and discusses the possible treatment options, based on a systematic review of the literature. Level of evidence V.


Assuntos
Síndrome de Colisão do Ombro/diagnóstico , Síndrome de Colisão do Ombro/terapia , Dor de Ombro/terapia , Artroscopia , Fenômenos Biomecânicos , Diagnóstico por Imagem , Humanos , Anamnese , Exame Físico , Cuidados Pós-Operatórios , Síndrome de Colisão do Ombro/complicações , Síndrome de Colisão do Ombro/etiologia , Dor de Ombro/etiologia
17.
Eur Heart J ; 33(10): 1214-22, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22447805

RESUMO

AIMS: The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS AND RESULTS: We pooled individual patient data from three large-scale multicentre randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4, and LEADERS) comparing biodegradable polymer DES with durable polymer SES and assessed clinical outcomes during follow-up through 4 years. The efficacy endpoint of interest was target lesion revascularization and the safety endpoint of interest was definite stent thrombosis. Out of 4062 patients included in the present analysis, 2358 were randomly assigned to treatment with biodegradable polymer DES (sirolimus-eluting, n= 1501; biolimus-eluting, n= 857) and 1704 patients to durable polymer SES. No heterogeneity across the trials was observed in analyses of the primary and secondary endpoints. At 4 years, the risk of target lesion revascularization was significantly lower among patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.82, 95% CI 0.68-0.98, P= 0.029). In addition, the risk of stent thrombosis was significantly reduced with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.56, 95% CI 0.35-0.90, P= 0.015), driven by a lower risk of very late stent thrombosis (hazard ratio 0.22, 95% CI 0.08-0.61, P= 0.004). In keeping with this, in landmark analysis between 1 and 4 years, the incidence of myocardial infarction was lower for patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.59, 95% CI 0.73-0.95, P= 0.031). CONCLUSION: Biodegradable polymer DES improve safety and efficacy compared with durable polymer SES during long-term follow-up to 4 years.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Stents Farmacológicos , Imunossupressores/administração & dosagem , Infarto do Miocárdio/terapia , Sirolimo/administração & dosagem , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
18.
Lancet ; 379(9824): 1393-402, 2012 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-22445239

RESUMO

BACKGROUND: The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. METHODS: For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. FINDINGS: 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up. INTERPRETATION: In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. FUNDING: The Cardiovascular Research Foundation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Falha de Prótese , Stents/efeitos adversos , Trombose/etiologia , Angioplastia Coronária com Balão/efeitos adversos , Reestenose Coronária/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Estenose Coronária/terapia , Medicina Baseada em Evidências , Feminino , Humanos , Incidência , Itália , Masculino , Paclitaxel/uso terapêutico , Prognóstico , Radiografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Sirolimo/uso terapêutico , Análise de Sobrevida , Trombose/epidemiologia
19.
Clin Res Cardiol ; 101(6): 461-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22422445

RESUMO

BACKGROUND: Everolimus-eluting stents (EES; Xience V) are among the most commonly used newer generation drug-eluting stents in clinical practice and have clearly proven superiority over paclitaxel-eluting stents. Nevertheless, the relative merits of EES against the previous gold-standard sirolimus-eluting stent (SES; Cypher) have been less extensively assessed. We aimed to compare the clinical outcomes of EES with SES in patients with coronary artery disease undergoing percutaneous coronary intervention. METHODS AND RESULTS: We identified eight eligible randomized trials comparing EES with SES including 11,167 patients. The primary endpoint was the incidence of major adverse cardiac events (MACE). Secondary endpoints were target lesion revascularization (TLR) and the composite of definite and probable stent thrombosis. The follow-up ranged from 9 to 36 months. No heterogeneity across the trials was observed regarding the selected endpoints. There was no difference in risk of MACE (HR 0.91 [0.79-1.04]; p = 0.15), TLR (HR 0.86 [0.72-1.04]; p = 0.12) and the composite of definite and probable stent thrombosis (HR 0.84 [0.54-1.29], p = 0.42). The risk of definite stent thrombosis was significantly lower in patients receiving EES (HR 0.49 [0.27 to 0.91]; p = 0.02). CONCLUSION: Using the largest available dataset of patients treated in randomized trials, the present meta-analysis demonstrated that the use of EES versus SES was associated with comparable incidence of overall clinical events. However, EES may be associated with a lower risk of definite stent thrombosis.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Doença da Artéria Coronariana/fisiopatologia , Stents Farmacológicos/efeitos adversos , Everolimo , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo/administração & dosagem , Trombose/epidemiologia , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
20.
Am Heart J ; 162(4): 740-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21982668

RESUMO

BACKGROUND: There is an ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. We addressed this issue by making a synthesis of the available evidence on the relative long-term efficacy and safety of sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) in these patients. METHODS: Individual patient data were analyzed from 6 randomized trials specifically designed to compare SES with PES in diabetic patients. In total, 1183 patients were followed up for a median of 3.9 years (25th, 75th percentiles 3.4-4.5 years). The primary efficacy end point was target lesion revascularization (TLR). The composite of death and myocardial infarction (MI) was the primary safety end point. Stent thrombosis was a secondary end point. Overall hazard ratios (HRs) with 95% CIs were calculated as summary estimates. RESULTS: No significant heterogeneity was seen across the 6 randomized trials for all analyzed events. Sirolimus-eluting stent was associated with a significant reduction in the risk of TLR (HR 0.65 [0.47-0.91], P = .01). No significant differences were observed regarding the risk of death or MI (HR 1.04 [0.74-1.45], P = .83) and stent thrombosis (HR 1.00 [0.31-3.30], P = .67). Mortality was also not affected by the type of DES (HR 0.95 [0.65-1.39], P = .79). CONCLUSIONS: In diabetic patients with coronary artery disease, SES leads to a sustained reduction in the risk of TLR compared with PES. Both these DES types are, however, comparable with respect to the risk of stent thrombosis, MI, or death over long-term follow-up.


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Angiopatias Diabéticas/tratamento farmacológico , Stents Farmacológicos , Paclitaxel/administração & dosagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo/administração & dosagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...