1.
J Control Release ; 250: 36-47, 2017 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-28188808

RESUMO

We have developed a straightforward and efficient method of introducing radiopacity into Polyvinyl alcohol (PVA)-2-Acrylamido-2-methylpropane sulfonic acid (AMPS) hydrogel beads (DC Bead™) that are currently used in the clinic to treat liver malignancies. Coupling of 2,3,5-triiodobenzaldehyde to the PVA backbone of pre-formed beads yields a uniformly distributed level of iodine attached throughout the bead structure (~150mg/mL) which is sufficient to be imaged under standard fluoroscopy and computed tomography (CT) imaging modalities used in treatment procedures (DC Bead LUMI™). Despite the chemical modification increasing the density of the beads to ~1.3g/cm3 and the compressive modulus by two orders of magnitude, they remain easily suspended, handled and administered through standard microcatheters. As the core chemistry of DC Bead LUMI™ is the same as DC Bead™, it interacts with drugs using ion-exchange between sulfonic acid groups on the polymer and the positively charged amine groups of the drugs. Both doxorubicin (Dox) and irinotecan (Iri) elution kinetics for all bead sizes evaluated were within the parameters already investigated within the clinic for DC Bead™. Drug loading did not affect the radiopacity and there was a direct relationship between bead attenuation and Dox concentration. The ability (Dox)-loaded DC Bead LUMI™ to be visualized in vivo was demonstrated by the administration of into hepatic arteries of a VX2 tumor-bearing rabbit under fluoroscopy, followed by subsequent CT imaging.


Assuntos
Antineoplásicos/administração & dosagem , Camptotecina/análogos & derivados , Doxorrubicina/administração & dosagem , Animais , Antineoplásicos/química , Benzaldeídos/química , Camptotecina/administração & dosagem , Camptotecina/química , Linhagem Celular Tumoral , Quimioembolização Terapêutica , Preparações de Ação Retardada , Doxorrubicina/química , Portadores de Fármacos , Liberação Controlada de Fármacos , Feminino , Humanos , Iodobenzenos/química , Troca Iônica , Irinotecano , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Microesferas , Imagem Óptica , Tamanho da Partícula , Álcool de Polivinil/química , Coelhos , Propriedades de Superfície , Tomografia Computadorizada por Raios X
2.
Theranostics ; 6(1): 28-39, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26722371

RESUMO

PURPOSE: Embolotherapy using microshperes is currently performed with soluble contrast to aid in visualization. However, administered payload visibility dimishes soon after delivery due to soluble contrast washout, leaving the radiolucent bead's location unknown. The objective of our study was to characterize inherently radiopaque beads (RO Beads) in terms of physicomechanical properties, deliverability and imaging visibility in a rabbit VX2 liver tumor model. MATERIALS AND METHODS: RO Beads, which are based on LC Bead® platform, were compared to LC Bead. Bead size (light microscopy), equilibrium water content (EWC), density, X-ray attenuation and iodine distribution (micro-CT), suspension (settling times), deliverability and in vitro penetration were investigated. Fifteen rabbits were embolized with either LC Bead or RO Beads + soluble contrast (iodixanol-320), or RO Beads+dextrose. Appearance was evaluated with fluoroscopy, X-ray single shot, cone-beam CT (CBCT). RESULTS: Both bead types had a similar size distribution. RO Beads had lower EWC (60-72%) and higher density (1.21-1.36 g/cc) with a homogeneous iodine distribution within the bead's interior. RO Beads suspension time was shorter than LC Bead, with durable suspension (>5 min) in 100% iodixanol. RO Beads ≤300 µm were deliverable through a 2.3-Fr microcatheter. Both bead types showed similar penetration. Soluble contrast could identify target and non-target embolization on fluoroscopy during administration. However, the imaging appearance vanished quickly for LC Bead as contrast washed-out. RO Beads+contrast significantly increased visibility on X-ray single shot compared to LC Bead+contrast in target and non-target arteries (P=0.0043). Similarly, RO beads demonstrated better visibility on CBCT in target arteries (P=0.0238) with a trend in non-target arteries (P=0.0519). RO Beads+dextrose were not sufficiently visible to monitor embolization using fluoroscopy. CONCLUSION: RO Beads provide better conspicuity to determine target and non-target embolization compared to LC Bead which may improve intra-procedural monitoring and post-procedural evaluation of transarterial embolization.


Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Microesferas , Radiografia/métodos , Coloração e Rotulagem/métodos , Animais , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos , Fluoroscopia , Neoplasias Hepáticas/diagnóstico por imagem , Coelhos
3.
J Appl Clin Med Phys ; 16(5): 408-417, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699297

RESUMO

The purpose of this study was to reduce pediatric doses while maintaining or improv-ing image quality scores without removing the grid from X-ray beam. This study was approved by the Institutional Animal Care and Use Committee. Three piglets (5, 14, and 20 kg) were imaged using six different selectable detector air kerma (Kair) per frame values (100%, 70%, 50%, 35%, 25%, 17.5%) with and without the grid. Number of distal branches visualized with diagnostic confidence relative to the injected vessel defined image quality score. Five pediatric interventional radiologists evaluated all images. Image quality score and piglet Kair were statistically compared using analysis of variance and receiver operating curve analysis to define the preferred dose setting and use of grid for a visibility of 2nd and 3rd order vessel branches. Grid removal reduced both dose to subject and imaging quality by 26%. Third order branches could only be visualized with the grid present; 100% detector Kair was required for smallest pig, while 70% detector Kair was adequate for the two larger pigs. Second order branches could be visualized with grid at 17.5% detector Kair for all three pig sizes. Without the grid, 50%, 35%, and 35% detector Kair were required for smallest to largest pig, respectively. Grid removal reduces both dose and image quality score. Image quality scores can be maintained with less dose to subject with the grid in the beam as opposed to removed. Smaller anatomy requires more dose to the detector to achieve the same image quality score.


Assuntos
Coração/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Angiografia , Animais , Pré-Escolar , Humanos , Recém-Nascido , Imagens de Fantasmas , Doses de Radiação , Espalhamento de Radiação , Suínos , Raios X
4.
AJR Am J Roentgenol ; 203(4): 904-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25247959

RESUMO

OBJECTIVE: The purpose of this study was to validate the hypothesis that image quality of digital subtraction angiography (DSA) in pediatrics is not impaired when using a low-dose acquisition protocol. MATERIALS AND METHODS: Three piglets corresponding to common pediatric population sizes were used. DSA was performed in the aorta and renal, hepatic, and superior mesenteric arteries using both the commonly used reference standard and novel radiographic imaging noise reduction technologies to ensure pairwise radiation dose and image quality comparison. The air kerma per frame at the interventional reference point for each DSA acquisition was collected as a radiation dose measure, and image quality was evaluated by five interventional radiologists in a randomized blinded fashion using a 5-point scale. RESULTS: The mean air kerma (± SD) at the interventional reference point with the novel x-ray imaging noise reduction technology was significantly lower (1.1 ± 0.8 mGy/frame) than with the reference technology (4.2 ± 3.0 mGy/frame, p = 0.005). However, image quality was statistically similar, with average scores of 3.2 ± 0.4 and 3.1 ± 0.5 for the novel and reference technologies, respectively (p = 0.934); interrater absolute agreement was 0.77. CONCLUSION: The DSA radiation dose for pediatrics can be reduced by a factor of four with a novel x-ray imaging noise reduction technology without deterioration of image quality.


Assuntos
Angiografia Digital/métodos , Modelos Animais , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Animais , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...