RESUMO
We studied the haemodynamic effects of intra-abdominal insufflation with either CO2 (n = 15) or N2O (n = 15) in patients undergoing laparoscopic surgery. Haemodynamic variables were measured at increasing levels of intra-abdominal pressure up to 20 mmHg. In the CO2 group cardiac index decreased from 2.6 +/- 0.6 to 2.0 +/- 0.4 litre min-1 m-2 (mean +/- SD, P < 0.001) and in the N2O group from 2.6 +/- 0.5 to 1.8 +/- 0.4 litre min-1 m-2 (P < 0.001)). In the CO2 group, this was accompanied by increases in mean arterial pressure, systemic vascular resistance index and central venous pressure without change in heart rate. In contrast, during N2O insufflation mean arterial pressure decreased (from 77 +/- 8 to 63 +/- 15 mmHg (P < 0.001)) without change in vascular resistance. No further changes in haemodynamic variables were observed during head-up tilt in both groups. After desufflation mean arterial pressure increased in the N2O group to pre-insufflation levels and cardiac index increased in both groups (P < 0.001), but reached pre-insufflation levels only in the CO2 group. In both groups central venous O2 tension and saturation decreased at maximum intra-abdominal pressure and increased after release of the pneumoperitoneum. The results indicate that laparoscopic insufflation with either CO2 or N2O results in cardiovascular depression. Insufflation with N2O may decrease blood pressure, whereas mean arterial pressure is better preserved with CO2 insufflation.
Assuntos
Dióxido de Carbono , Hemodinâmica , Laparoscopia , Óxido Nitroso , Pneumoperitônio Artificial , Adulto , Pressão Sanguínea , Débito Cardíaco , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Pneumoperitônio Artificial/métodos , Resistência VascularRESUMO
The effects of anesthetic technique (nitrous oxide or propofol) and high-pass digital filtering on within-patient variability of posterior tibial nerve somatosensory cortical evoked potentials (PTN-SCEP) were compared prospectively in two groups of 20 patients undergoing spinal surgery. Average P1N1 amplitude was significantly higher and P1N1 amplitude variability lower during propofol/alfentanil anesthesia than during nitrous oxide/alfentanil anesthesia. Off-line 30-Hz high-pass digital filtering significantly reduced P1N1 amplitude variability without decreasing P1N1 amplitude. In 93 patients studied retrospectively, a significant negative logarithmic correlation (r = -0.77) was observed between P1N1 amplitude and P1N1 amplitude variability. This study shows the importance of maintaining the highest possible PTN-SCEP amplitudes during spinal surgery. Propofol/opioid anesthesia may be an alternative anesthetic technique to nitrous oxide/opioid anesthesia during spinal cord function monitoring.