Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Endocrinol (Lausanne) ; 13: 926210, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966052

RESUMO

Growth hormone (GH) and insulin-like growth factor-1 (IGF1) play an important role in mammalian development, cell proliferation and lifespan. Especially in cases of tumor growth there is an urgent need to control the GH/IGF1 axis. In this study we screened a 38,480-compound library, and in two consecutive rounds of analogues selection, we identified active lead compounds based on the following criteria: inhibition the GH receptor (GHR) activity and its downstream effectors Jak2 and STAT5, and inhibition of growth of breast and colon cancer cells. The most active small molecule (BM001) inhibited both the GH/IGF1 axis and cell proliferation with an IC50 of 10-30 nM of human cancer cells. BM001 depleted GHR in human lymphoblasts. In preclinical xenografted experiments, BM001 showed a strong decrease in tumor volume in mice transplanted with MDA-MB-231 breast cancer cells. Mechanistically, the drug acts on the synthesis of the GHR. Our findings open the possibility to inhibit the GH/IGF1 axis with a small molecule.


Assuntos
Hormônio do Crescimento Humano , Receptores da Somatotropina , Animais , Proliferação de Células , Hormônio do Crescimento/fisiologia , Humanos , Fator de Crescimento Insulin-Like I , Mamíferos , Camundongos
2.
Cytometry B Clin Cytom ; 96(5): 426-435, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31301165

RESUMO

BACKGROUND: Flow cytometry essentially focuses on surface-expressed proteins, with few protocols being devoted to intracellular components. We evaluated a two-step procedure using new formaldehyde-free permeabilization and staining reagents that allow the staining of platelets and red blood cells (RBCs) from whole blood. METHODS: Citrated blood was treated with the new staining protocol (NSP) or control reagent (phosphate-buffered solution bovine serum albumin) and stained with antibodies against surface or intracellular markers. The effects of the NSP on cell integrity, morphology, and content were evaluated. RESULTS: The NSP slightly reduced the cell count (~20%) and changed the RBC morphology with a 42% mean diameter reduction. Conversely, the NSP did not affect platelet discoid morphology and led to a minor size decrease (11%). These morphological changes neither impelled a gating strategy modification nor interfered with the discrimination among populations based on surface markers. The NSP provided intracellular access to all the tested antigens: CD62P, FXIII, and CD63 in platelets and glycated and fetal hemoglobin (HbA1c and HbF) and nucleic acid in RBCs. The NSP gave excellent intra-assay precision with minimal impact on cell morphology and fluorescence labelling over time (up to 24 h). CONCLUSIONS: With the ability to detect surface and intracellular antigens through a rapid preparation protocol without washing steps or toxic formaldehyde treatment, this NSP designed for research offers a marked improvement in the analysis of platelets and RBCs isolated directly from whole blood. Consequently, the NSP opens new avenues to investigate platelet degranulation and erythrocyte subpopulations. © 2019 International Clinical Cytometry Society.


Assuntos
Plaquetas/citologia , Eritrócitos/citologia , Plaquetas/metabolismo , Permeabilidade da Membrana Celular , Eritrócitos/metabolismo , Citometria de Fluxo/métodos , Humanos
3.
J Biomol Screen ; 20(3): 416-21, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25325258

RESUMO

Drug discovery often requires the screening of compound libraries on tissue cultured cells. Some major targets in drug discovery belong to signal transduction pathways, and PerFix EXPOSE* allows easy flow cytometry phospho assays. We thus investigated the possibility to further simplify and automate this assay, to allow the direct screening of drugs targeting signaling pathways. We show here the sensitivity of this fully automated assay on human growth hormone (hGH)-driven JAK/STAT5-activated IM-9 cells, and we discuss the throughput of this system, which is compatible with medium-throughput drug screening. Because the kit works directly on whole blood samples, ex-vivo assays are also possible with this approach, which could allow for the screening of drugs under more physiological conditions.


Assuntos
Automação , Descoberta de Drogas/métodos , Citometria de Fluxo/métodos , Fator de Transcrição STAT5/metabolismo , Linhagem Celular , Descoberta de Drogas/instrumentação , Avaliação Pré-Clínica de Medicamentos/instrumentação , Avaliação Pré-Clínica de Medicamentos/métodos , Citometria de Fluxo/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Hormônio do Crescimento Humano/farmacologia , Humanos , Janus Quinases/metabolismo , Permeabilidade/efeitos dos fármacos , Fosforilação/efeitos dos fármacos , Reprodutibilidade dos Testes , Bibliotecas de Moléculas Pequenas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...