Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
2.
Clin Res Cardiol Suppl ; 10: 33-8, 2015 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-25666917

RESUMO

The clinical relevance of lipoprotein(a) (Lp(a)) as a cardiovascular risk factor is currently underestimated. The aim of our study was to assess the influence of increased Lp(a) values on the development and severity of coronary artery disease (CAD).In our retrospective analysis of 31,274 patients, who were hospitalized for the first time, we compared patients with isolated increased Lp(a) (> 110 mg/dl) and normal Lp(a) (< 30 mg/dl), with increased Lp(a) concentrations (30-60 mg/dl, 61-90 mg/dl, 91-110 mg/dl), and in a third analysis with additionally increased LDL cholesterol and HbA1c values.Patients with high Lp(a) levels showed a significantly higher incidence of advanced CAD with a three-vessel disease being present in 50.2 vs. 25.1 %. Patients with high Lp(a) levels had a significantly more frequent history of myocardial infarction (34.6 vs. 16.6 %, p < 0.001), surgical myocardial revascularization (40.8 vs. 20.8 %, p < 0.001) and percutaneous coronary intervention (55.3 vs. 33.6 %, p < 0.001). In addition, there was a marked difference in gender to the disadvantage of male patients regarding development and severity of CAD. CAD risk (Odds ratio) was increased 5.5-fold in patients with Lp(a) ≥ 110 mg/dl. Additionally elevated LDL and HbA1c levels were not associated with increased manifestation and severity of CAD.High Lp(a) concentration leads to an increased manifestation and severity of coronary artery disease. Additional risk factors do not aggravate manifestation of CAD.


Assuntos
Arteriopatias Oclusivas/sangue , Arteriopatias Oclusivas/epidemiologia , Estenose das Carótidas/sangue , Estenose das Carótidas/epidemiologia , Lipoproteína(a)/sangue , Idoso , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
3.
Rehabilitation (Stuttg) ; 53(5): 321-6, 2014 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-24363218

RESUMO

AIM OF THE STUDY: Regular physical activity has found to be a strategy to increase exercise capacity in patients with chronic heart failure (CHF). Next to endurance training also electromyostimulation (EMS) of thigh and gluteal muscles results in an increased capacity in CHF patients. EMS therapy was either done by stimulating 8 major muscle groups involving also trunk and arm muscles (extended electromyostimulation (exEMS)) in comparison to EMS therapy limited to gluteal and leg muscles (limEMS). METHODS: 31 individuals completed the EMS training program. Stable CHF patients (NYHA class II-III) received either exEMS (18 patients, 11 males, mean age 59.8±13.8 years) or limEMS (13 patients, 10 males, 63.6±9.4 years). Training was performed for 10 weeks twice weekly for 20 min, the level of daily activity remained unchanged. Effects on exercise capacity, left ventricular function (EF - ejection fraction) and QoL (quality of life) were evaluated. RESULTS: QoL was found to be improved in all domains of the SF-36 questionnaire. In the exEMS group there was a significant improvement in the domain physical functioning (54.09±29.9 to 75.45±15.6, p=0.48) and emotional role (63.63±45.8 to 93.93±20.1 p=0.048). LimEMS group showed significant improvement in the domain vitality (37.5±6.9 to 52.8±12.5, p=0.02).There was a significant increase of oxygen uptake at aerobic threshold in all groups (exEMS: +29.6%, p<0.001; limEMS +17.5%, p<0.001). EF -increased from 36.94±8.6 to 42.36±9.1% (+14.7%, p=0.003) in the exEMS group (limEMS 37.7±3.6 to 40.3±5.9% [+6.9%, p=0.18]). CONCLUSION: EMS contributes to an improved quality of life and can improve oxygen uptake and EF in CHF. It may be an alternative therapy in CHF patients who are otherwise unable to undertake conventional forms of exercise training.


Assuntos
Terapia por Estimulação Elétrica/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/reabilitação , Consumo de Oxigênio , Condicionamento Físico Humano/métodos , Qualidade de Vida/psicologia , Volume Sistólico , Doença Crônica , Terapia por Estimulação Elétrica/psicologia , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Condicionamento Físico Humano/psicologia , Aptidão Física , Resultado do Tratamento
4.
Int J Sports Med ; 34(3): 200-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22972237

RESUMO

The key challenge in athlete's screening is the distinction between abnormal and normal which is hindered by the fact that the adaptation to sports activity in endurance athletes is different to that in power athletes. Especially cardiomyopathies provoke changes in ECG and echocardiography (echo) at an early stage when clinical symptoms are absent. ECG and echo data and their relationship to fitness peculiar to top handball players have never been described. We studied 291 male first league handball players (32 Olympians/47 national players) (25.3±4.4 years). Check up consisted of ECG, spiroergometry and echocardiography. None had T-wave inversions, 3.1% showed early repolarisation abnormalities in the precordial leads. Sokolow-Lyon voltage criterion for left ventricular hypertrophy was positive in 19.3%. Spiroergometry showed a maximum oxygen uptake (peakVO2) of 50.3±7.7 ml/min/kg body weight. LVmass was increased in comparison to normal values. There was a correlation between peakVO2 and LVindex (p<0.001, r=0.341), (LVmass/peak VO2 p=0.053, r=0.125). A relationship between cardiac dimensions and peakVO2 could not be confirmed. In professional handball players early repolarisation abnormalities were less frequent and LVmass was increased when compared with soccer players. The need for normal values for different types of sports is crucial to guarantee a proper evaluation of athletes.


Assuntos
Cardiomiopatias/diagnóstico , Hipertrofia Ventricular Esquerda/diagnóstico , Consumo de Oxigênio , Esportes/fisiologia , Adolescente , Adulto , Determinação da Pressão Arterial , Eletrocardiografia , Teste de Esforço , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Aptidão Física , Valores de Referência , Estudos Retrospectivos , Espirometria , Ultrassonografia , Adulto Jovem
5.
Minerva Med ; 103(6): 503-11, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23229369

RESUMO

The implementation of bare metal stents and later drug eluting stents (DES) proved to be an important step forward in reducing rates of restenosis after percutaneous coronary intervention. Despite all the benefits of DES, concerns have been raised over their long term safety as especially stent thrombosis sets patients at risk. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to evaluate accurately treatment differences between stents. However, a consistent finding from randomized, controlled trials of DES versus bare metal stents is the significantly reduced reintervention rate associated with DES use. The clinical presentation of restenosis is recurrent angina or acute coronary syndrome. Optimal implantation of the stent in the vessel and adequate antiplatelet therapy are of utmost significance to provide best results. Intravascular imaging often helps to provide optimal delivery of the stent. Newer stents have now been developed. Especially DES with biogradable polymers, novel coatings of the stent, and polymer free DES have to be mentioned and early results seem to be promising. The perspective of bioresorbable DES platforms includes the additional benefits of improved recovery in vessel function and the potential for reducing the requirement for prolonged dual antiplatelet therapy. This article reviews the etiology, treatment options and outcome of in stent restenosis and gives an overview about the new developments in the field of stent technology.


Assuntos
Reestenose Coronária , Trombose Coronária , Stents Farmacológicos/efeitos adversos , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Trombose Coronária/etiologia , Trombose Coronária/terapia , Humanos , Stents/efeitos adversos , Resultado do Tratamento
6.
Eur J Prev Cardiol ; 19(6): 1333-56, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22637740

RESUMO

The beneficial effect of exercise training and exercise-based cardiac rehabilitation on symptom-free exercise capacity,cardiovascular and skeletal muscle function, quality of life, general healthy lifestyle, and reduction of depressive symptoms and psychosocial stress is nowadays well recognized. However, it remains largely obscure, which characteristics of physical activity (PA) and exercise training--frequency, intensity, time (duration), type (mode), and volume (dose: intensity x duration) of exercise--are the most effective. The present paper, therefore, will deal with these exercise characteristics in the management of individuals with cardiovascular disease, i.e. coronary artery disease and chronic heart failure patients, but also in patients with congenital or valvular heart disease. Based on the current literature, and if sufficient evidence is available, recommendations from the European Association on Cardiovascular Prevention and Rehabilitation are formulated regarding frequency, intensity, time and type of PA, and safety aspects during exercise inpatients with cardiovascular disease. This paper is the third in a series of three papers, all devoted to the same theme: the importance of the exercise characteristics in the management of cardiovascular health. Part I is directed to the general population and Part II to individuals with cardiovascular risk factors. In general, PA recommendations and exercise training programmes for patients with coronary artery disease or chronic heart failure need to be tailored to the individual's exercise capacity and risk profile, with the aim to reach and maintain the individually highest fitness level possible and to perform endurance exercise training 30­60 min daily (3­5 days per week) in combination with resistance training 2­3 times a week. Because of the frequently reported dose­response relationship between training effect and exercise intensity, one should seek sufficiently high training intensities, although more scientific evidence on effect sizes and safety is warranted. At present, there is insufficient data to give more specific recommendations on type, dosage, and intensity of exercise in some other cardiovascular diseases, such as congenital heart disease, valve disease, cardiomyopathies, channelopathies, and patients with implanted devices.


Assuntos
Reabilitação Cardíaca , Terapia por Exercício/métodos , Tolerância ao Exercício , Atividade Motora , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Terapia por Exercício/efeitos adversos , Humanos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Eur J Prev Cardiol ; 19(5): 1005-33, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22637741

RESUMO

In a previous paper, as the first of a series of three on the importance of characteristics and modalities of physical activity (PA) and exercise in the management of cardiovascular health within the general population, we concluded that, in the population at large, PA and aerobic exercise capacity clearly are inversely associated with increased cardiovascular disease risk and all-cause and cardiovascular mortality and that a dose­response curve on cardiovascular outcome has been demonstrated in most studies. More and more evidence is accumulated that engaging in regular PA and exercise interventions are essential components for reducing the severity of cardiovascular risk factors, such as obesity and abdominal fat, high BP, metabolic risk factors, and systemic inflammation. However, it is less clear whether and which type of PA and exercise intervention (aerobic exercise, dynamic resistive exercise, or both) or characteristic of exercise (frequency, intensity, time or duration, and volume) would yield more benefit for each separate risk factor. The present paper, therefore, will review and make recommendations for PA and exercise training in the management of cardiovascular health in individuals with cardiovascular risk factors. The guidance offered in this series of papers is aimed at medical doctors, health practitioners, kinesiologists, physiotherapists and exercise physiologists, politicians, public health policy makers, and individual members of the public. Based on previous and the current literature overviews, recommendations from the European Association on Cardiovascular Prevention and Rehabilitation are formulated regarding type, volume, and intensity of PA and regarding appropriate risk evaluation during exercise in individuals with cardiovascular risk factors.


Assuntos
Atividades Cotidianas , Doenças Cardiovasculares/prevenção & controle , Terapia por Exercício/normas , Exercício Físico/fisiologia , Obesidade/reabilitação , Guias de Prática Clínica como Assunto , Saúde Pública , Doenças Cardiovasculares/etiologia , Humanos , Obesidade/complicações , Fatores de Risco
8.
Clin Res Cardiol Suppl ; 7: 45-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22528131

RESUMO

In the treatment of homozygous and therapy-resistant hypercholesterolemia, lipid apheresis enables not only low density lipoprotein (LDL) cholesterol to be lowered by approximately 60%, but also oxidative stress factors to be influenced and adhesion molecules reduced. This was investigated in a group of 12 patients using the heparin-induced extracorporeal LDL precipitation (H.E.L.P.) procedure.A significant lowering of LDL cholesterol and fibrinogen leads to an improvement in rheology and endothelial function, detectable and measurable within approximately 20 h by assessing minimum coronary resistance using positron emission tomography (PET) performed in 35 patients. This effect is detectable even after the first lipid apheresis session (H.E.L.P. procedure), documented in 12 patients.Lipid apheresis appears to be the most effective procedure in the treatment of elevated lipoprotein(a) [Lp(a)]. A chosen group of nine patients with selective elevated Lp(a) illustrated both the influence on endothelial dysfunction, in the shape of sharply increased minimum coronary resistance, and the reduction through lipid apheresis, indicating that Lp(a) seems to exert a similar effect on the vascular wall and vascular function as LDL cholesterol.


Assuntos
Remoção de Componentes Sanguíneos/métodos , LDL-Colesterol/sangue , Doença da Artéria Coronariana/terapia , Hiperlipoproteinemia Tipo II/terapia , Adulto , Idoso , Precipitação Química , Doença da Artéria Coronariana/fisiopatologia , Circulação Extracorpórea/métodos , Feminino , Heparina/química , Humanos , Hipercolesterolemia/fisiopatologia , Hipercolesterolemia/terapia , Hiperlipoproteinemia Tipo II/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo , Tomografia por Emissão de Pósitrons , Reologia , Resultado do Tratamento , Resistência Vascular , Vasodilatação
9.
Ultraschall Med ; 33(5): 455-62, 2012 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-21294072

RESUMO

BACKGROUND AND OBJECTIVE: Echocardiographic Tissue Doppler Imaging (TDI) has been proposed for the differentiation of pathological left ventricular hypertrophy (e. g. hypertrophic cardiomyopathy, HCM) and physiologic left ventricular hypertrophy (athlete's heart). The aim of this study was the TDI analysis of the systolic (S') and early diastolic (E') velocities in patients (pts.) with non-obstructive hypertrophic cardiomyopathy (HCM) and in top-level athletes in consideration of the previously published cut-off values (S' < 9 cm/s, E' < 9 cm/s). PATIENTS AND METHODS: Pulsed-wave TDI of the systolic and early-diastolic velocities was performed at the lateral and septal mitral annulus in the four-chamber view in 17 HCM pts (12 men; mean age 44 ± 16 years) and 80 consecutive athletes (80 men; mean age 26 ± 5 years). RESULTS: Pts with HCM showed significantly decreased systolic velocities of the septal (S' septal: 5.1 ± 1.2 cm/s versus 9.5 ± 1.5 cm/s, p < 0.001) and lateral mitral annulus (S' lateral: 6.4 ± 2.0 cm/s vs. 10.5 ± 2.1 cm/s, p < 0.001). The early diastolic velocity of the mitral annulus E' was significantly decreased in HCM, too (E' septal: 5.9 ± 2.2 cm/s vs. 13.1 ± 2.9 cm/s, p < 0.001; E' lateral: 8.2 ± 3.0 cm/s vs. 16.5 ± 3.4 cm/s, p < 0.001). CONCLUSION: Tissue Doppler Imaging of the systolic and early diastolic velocity of the mitral annulus might be helpful as a promising additional method for the echocardiographic differentiation between pathological and physiologic left ventricular hypertrophy.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Cardiomegalia Induzida por Exercícios/fisiologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Ecocardiografia Doppler/métodos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Esportes/fisiologia , Adulto , Diagnóstico Diferencial , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Sístole/fisiologia , Adulto Jovem
10.
Vasa ; 40(6): 468-73, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22090180

RESUMO

BACKGROUND: Carotid artery stenting (CAS) from the femoral approach can be anatomically very difficult and the incidence of complications is higher in patients with anatomical variations of the aortic arch, difficulties related to peripheral vascular disease and/or with access site complications. Because the typical morphology in patients with a bovine- or type-III aortic arch applies for an arterial access from the right upper extremity (e.g. radial, brachial) we evaluated success rates and safety of the right transradial access in a prospective study. PATIENTS AND METHODS: Between June 2009 and October 2010, seventeen patients (mean age 74,4 ± 9 years, 10 male) with a bovine- (n = 4) or type-III aortic arch (n = 12) underwent CAS with a planned transradial- (n = 3) or after problematic transfemoral access (n = 14). In patients with a type-III aortic arch (n = 13), the right target common carotid artery (CCA) was cannulated from the right radial artery with a 5F IMA diagnostic catheter-, in patients with a bovine aortic arch (n = 4), the left CCA was accessed from the right radial artery with a 5F Amplatz- or Judkins left catheter. In all patients a 6F- (n = 14) or 5F- (n = 3) shuttle sheath was inserted via the diagnostic catheter and a 0.035” extra-stiff guidewire. All interventions were carried out with the use of a peripheral embolization protection device (EPD). Primary study endpoints were procedural success and major adverse cardiac and cerebrovascular events (MACCE), secondary endpoints were access site complications and the mean intervention time. RESULTS: Procedural success could be achieved in all patients (100 %), MACCE and access site complications did not occur in any patient. Mean interventional time was 48 ± 18 min. CONCLUSIONS: CAS using the right transradial approach for left CAS in bovine-type aortic arch or the right transradial approach in type-III aortic arch for right CAS appears to be safe and technically feasible.


Assuntos
Angioplastia/métodos , Aorta Torácica , Estenose das Carótidas/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Angiografia , Aorta Torácica/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial , Acidente Vascular Cerebral/prevenção & controle
11.
Int J Cardiovasc Imaging ; 27(1): 91-100, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20623194

RESUMO

Two-dimensional strain (2DS) is a novel method to measure strain from standard two-dimensional echocardiographic images by speckle tracking, which is less angle dependent and more reproducible than conventional Doppler-derived strain. The objective of our study was to characterize global and regional function abnormalities using 2DS and strain rate analysis in patients (pts) with pathological left ventricular hypertrophy (LVH) caused by non-obstructive hypertrophic cardiomyopathy (HCM), in top level athletes, and in healthy controls. The hypothetical question was, if 2DS might be useful as additional tool in differentiating between pathologic and physiologic hypertrophy in top-level athletes. We consecutively studied 53 subjects, 15 pts with hypertrophic cardiomyopathy (HCM), 20 competitive top-level athletes, and a control group of 18 sedentary normal subjects by standard echocardiography according to ASE guidelines. Global longitudinal strain (GLS) and regional peak systolic strain (PSS) was assessed by 2DS in the apical four-chamber-view using a dedicated software. All components of strain were significantly reduced in pts with HCM (GLS: -8.1 ± 3.8%; P < 0.001) when compared with athletes (-15.2 ± 3.6%) and control subjects (-16.0 ± 2.8%). In general, there was no significant difference between the strain values of the athletes and the control group, but in some of the segments, the strain values of the control group were significantly higher than those in the athletes. A cut-off value of GLS less than -10% for the diagnosis of pathologic hypertrophy (HCM) resulted in a sensitivity of 80.0% and a specificity of 95.0%. The combination of TDI (averaged S', E') and 2DS (GLS) cut-off values for the detection of pathologic LVH in HCM demonstrated a sensitivity of 100%, and a specificity of 95%. Two-dimensional strain is a new simple and rapid method to measure GLS and PSS as components of systolic strain. This technique could offer a unique approach to quantify global as well as regional systolic dysfunction, and might be used as new additional tool for the differentiation between physiologic and pathologic LVH.


Assuntos
Atletas , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Doppler , Exercício Físico , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Contração Miocárdica , Função Ventricular Esquerda , Adaptação Fisiológica , Adulto , Análise de Variância , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Software , Adulto Jovem
12.
Int J Cardiovasc Imaging ; 25(7): 699-704, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19655270

RESUMO

The purpose of this study is to assess the incremental value of tissue Doppler (TDI) derived displacement curves (TDint) compared to TDI velocity curves (TDvel) for the evaluation of left ventricular (LV) dyssynchrony (LVD). About 25 patients (pts.) with systolic heart failure were studied by TDvel and TDint. Four TDI sample volumes were placed at the basal and four at the mid ventricular myocardium, utilising two imaging planes. LV dyssynchrony (LVD) was defined as an interregional delay of >40 ms corrected for heart rate. 10 pts. had synchronous contraction, 15 pts. LVD as defined by two experts (EC). To determine diagnostic accuracy and intra-observer variability two identical sets of 100 documents (25 pts. x two imaging planes x two modalities) were produced and presented in random order to one trained (TR) and two untrained (UR) readers. The TR more frequently classified documents as unreadable (7.5 vs. 3.5%, P < 0.05) but more often as correct, i.e., consistent with EC (72.0 vs. 57.8%, P < 0.001). 8.7% of the documents were classified as unreadable using TDvel, 1.0% when applying TDint (P < 0.001). The mean value of correct classification of all 3 readers was 54.3% (TDvel only), 70.7% (TDint only), and 77.7% (combining both modalities), (P < 0.001). The kappa value for TR and TDint was 0.68, for TDvel 0.29. For UR, kappa did not differ (TDint: 0.58; TDvel 0.51). TDint is superior to TDvel in accuracy, reproducibility, and applicability for skilled and unskilled investigators when evaluating LVD by TDI. The combined application of TDint and TDvel is optimal.


Assuntos
Ecocardiografia Doppler em Cores , Insuficiência Cardíaca Sistólica/diagnóstico por imagem , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estimulação Cardíaca Artificial , Competência Clínica , Insuficiência Cardíaca Sistólica/fisiopatologia , Insuficiência Cardíaca Sistólica/terapia , Frequência Cardíaca , Humanos , Variações Dependentes do Observador , Seleção de Pacientes , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
17.
Int J Artif Organs ; 22(4): 205-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10466951

RESUMO

The control of intravascular volume (IVV) by continuous on-line measurement of protein concentration would optimise the patients' specific rate of ultrafiltration. To prove the accuracy of a refractometric device, plasma was continuously drawn by haemofiltration during 10 haemodialysis treatments of male patients. Refractometry reflects highly significant changes in the concentrations of filtrate proteins (r = 0.862, p < 0.001) and blood proteins (rtotal = 0.593, ptotal < 0.001). In vitro, the refractometric device detected a change of protein concentration of 0.041 g/L through a refraction increase of 0.1 mV. The power of discrimination was 0.067% of IVV However, in vivo, the accuracy of IVV refractometric monitoring is reduced by interference factors such as sodium (0. 141 mV/mmol/L), glucose (0.034 mV/mg/dl) and triglycerides (-0.040 mV/mg/dl). Adjustment of the refraction data using sodium and glucose electrodes and plasma filters with a cut-off below the size of chylomicrons is recommended.


Assuntos
Monitorização Fisiológica/métodos , Sistemas On-Line , Refratometria/métodos , Diálise Renal/métodos , Proteínas Sanguíneas/análise , Hemofiltração , Humanos , Masculino , Ultrafiltração/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...