1.
J Nucl Cardiol ; 30(5): 1890-1896, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37076608

RESUMO

INTRODUCTION: Our aim was to estimate the probability of obstructive CAD (oCAD) for an individual patient as a function of the myocardial flow reserve (MFR) measured with Rubidium-82 (Rb-82) PET in patients with a visually normal or abnormal scan. MATERIALS AND METHODS: We included 1519 consecutive patients without a prior history of CAD referred for rest-stress Rb-82 PET/CT. All images were visually assessed by two experts and classified as normal or abnormal. We estimated the probability of oCAD for visually normal scans and scans with small (5%-10%) or larger defects (> 10%) as function of MFR. The primary endpoint was oCAD on invasive coronary angiography, when available. RESULTS: 1259 scans were classified as normal, 136 with a small defect and 136 with a larger defect. For the normal scans, the probability of oCAD increased exponentially from 1% to 10% when segmental MFR decreased from 2.1 to 1.3. For scans with small defects, the probability increased from 13% to 40% and for larger defects from 45% to > 70% when segmental MFR decreased from 2.1 to 0.7. CONCLUSION: Patients with > 10% risk of oCAD can be distinguished from patients with < 10% risk based on visual PET interpretation only. However, there is a strong dependence of MFR on patient's individual risk of oCAD. Hence, combining both visual interpretation and MFR results in a better individual risk assessment which may impact treatment strategy.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Radioisótopos de Rubídio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Circulação Coronária , Medição de Risco , Tomografia por Emissão de Pósitrons/métodos , Imagem de Perfusão do Miocárdio/métodos
2.
J Nucl Cardiol ; 30(4): 1504-1513, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36622542

RESUMO

INTRODUCTION: Accurate risk stratification in patients with suspected stable coronary artery disease is essential for choosing an appropriate treatment strategy. Our aim was to develop and validate a machine learning (ML) based model to diagnose obstructive CAD (oCAD). METHOD: We retrospectively have included 1007 patients without a prior history of CAD who underwent CT-based calcium scoring (CACS) and a Rubidium-82 PET scan. The entire dataset was split 4:1 into a training and test dataset. An ML model was developed on the training set using fivefold stratified cross-validation. The test dataset was used to compare the performance of expert readers to the model. The primary endpoint was oCAD on invasive coronary angiography (ICA). RESULTS: ROC curve analysis showed an AUC of 0.92 (95% CI 0.90-0.94) for the training dataset and 0.89 (95% CI 0.84-0.93) for the test dataset. The ML model showed no significant differences as compared to the expert readers (p ≥ 0.03) in accuracy (89% vs. 88%), sensitivity (68% vs. 69%), and specificity (92% vs. 90%). CONCLUSION: The ML model resulted in a similar diagnostic performance as compared to expert readers, and may be deployed as a risk stratification tool for obstructive CAD. This study showed that utilization of ML is promising in the diagnosis of obstructive CAD.


Assuntos
Doença da Artéria Coronariana , Humanos , Cálcio , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Angiografia Coronária/métodos , Aprendizado de Máquina , Valor Preditivo dos Testes , Angiografia por Tomografia Computadorizada/métodos
3.
J Nucl Cardiol ; 29(6): 3155-3162, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34970710

RESUMO

PURPOSE: Semi-quantitative scores can be used as an adjunct to visual assessment in rubidium-82 positron emission tomography (82Rb PET). The semi-quantitative cut-off values used in 82Rb PET are derived from single-photon emission computed tomography (SPECT). It is unknown whether these cut-off values can be extrapolated to 82Rb PET. We compared the semi-quantitative with the visual assessment of ischemia and determined which summed difference score (SDS) score predicts ischemia best. METHODS: We included 108 patients who underwent 82Rb PET imaging and performed visual and semi-quantitative assessment. A scan with a SDS ≥ 2 and a summed stress score (SSS) ≥ 4 was considered to demonstrate ischemia. We compared the semi-quantitative with the visual assessment. RESULTS: 41 (38%) Normal scans, and 67 (62%) scans with ischemia and/or an irreversible defect were included. The semi-quantitative assessment showed ischemia more often than the visual assessment (51% vs 29%, P < .001). Patients with a low or intermediate pre-test probability of coronary artery disease (CAD) and a SDS < 4 did not demonstrate ischemia by visual assessment. CONCLUSION: Semi-quantitative assessment in 82Rb PET imaging clearly demonstrates the presence of ischemia. Ischemia is unlikely in patients with low and intermediate pre-test probability of CAD and a SDS < 4.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia por Emissão de Pósitrons/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Radioisótopos de Rubídio , Isquemia
5.
J Nucl Cardiol ; 29(1): 204-212, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32410059

RESUMO

BACKGROUND: PET scanners using silicon photomultipliers with digital readout (SiPM PET) have an improved temporal and spatial resolution compared to PET scanners using conventional photomultiplier tubes (PMT PET). However, the effect on image quality and visibility of perfusion defects in myocardial perfusion imaging (MPI) is unknown. Our aim was to determine the value of a SiPM PET scanner in MPI. METHODS: We prospectively included 30 patients who underwent rest and regadenoson-induced stress Rubidium-82 (Rb-82) MPI on the D690 PMT PET (GE Healthcare) and within three weeks on the Vereos SiPM PET (Philips Healthcare). Two expert readers scored the image quality and assessed the existence of possible defects. In addition, interpreter's confidence, myocardial blood flow (MBF), and myocardial flow reserve (MFR) values were compared. RESULTS: Image quality improved (P = 0.03) using the Vereos as compared to the D690. Image quality of the Vereos and the D690 was graded fair in 20% and 10%, good in 60% and 50%, and excellent in 20% and 40%, respectively. Defect interpretation and interpreter's confidence did not differ between the D690 and the Vereos (P > 0.50). There were no significant differences in rest MBF (P ≥ 0.29), stress MBF (P ≥ 0.11), and MFR (P ≥ 0.51). CONCLUSION: SiPM PET provides an improved image quality in comparison with PMT PET. Defect interpretation, interpreter's confidence, and absolute blood flow measurements were comparable between both systems. SiPM PET is therefore a reliable technique for MPI using Rb-82. TRIAL REGISTRATION: ToetsingOnline NL63853.075.17. Registered 13 November, 2017.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio , Tomografia Computadorizada por Raios X
6.
J Nucl Cardiol ; 29(4): 1729-1741, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33655444

RESUMO

BACKGROUND: A variety of temporal sampling protocols is used worldwide to measure myocardial blood flow (MBF). Both the length and number of time frames in these protocols may alter MBF and myocardial flow reserve (MFR) measurements. We aimed to assess the effect of different clinically used temporal sampling protocols on MBF and MFR quantification in Rubidium-82 (Rb-82) PET imaging. METHODS: We retrospectively included 20 patients referred for myocardial perfusion imaging using Rb-82 PET. A literature search was performed to identify appropriate sampling protocols. PET data were reconstructed using 14 selected temporal sampling protocols with time frames of 5-10 seconds in the first-pass phase and 30-120 seconds in the tissue phase. Rest and stress MBF and MFR were calculated for all protocols and compared to the reference protocol with 26 time frames. RESULTS: MBF measurements differed (P ≤ 0.003) in six (43%) protocols in comparison to the reference protocol, with mean absolute relative differences up to 16% (range 5%-31%). Statistically significant differences were most frequently found for protocols with tissue phase time frames < 90 seconds. MFR did not differ (P ≥ 0.11) for any of the protocols. CONCLUSIONS: Various temporal sampling protocols result in different MBF values using Rb-82 PET. MFR measurements were more robust to different temporal sampling protocols.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Humanos , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos , Radioisótopos de Rubídio
7.
J Nucl Cardiol ; 29(5): 2448-2456, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34476779

RESUMO

BACKGROUND: Knowledge of coronary artery calcium score (CACS) influences the interpretation of myocardial perfusion imaging (MPI) with SPECT; however, the impact on PET interpretation remains unclear. We compared the added value of CACS to reporting MPI using SPECT vs PET. METHODS: We retrospectively included 412 patients. 206 patients who underwent Rb-82 PET were propensity-based matched to a cohort of 4018 patients who underwent cadmium-zinc-telluride SPECT MPI to obtain a comparable group of 206 SPECT patients. Next, we created four image sets: SPECT MPI-only, PET-only, SPECT + CACS, and PET + CACS. Two physicians interpreted the 824 images as normal, equivocal, or abnormal for ischemia or irreversible defects. Additionally, event rates were compared between PET and SPECT groups during 30-month follow-up. RESULTS: PET yielded more scans interpreted as normal than SPECT (88% vs 80%, respectively, P = 0.015). Adding CACS to SPECT increased the percentage of normal scans to 86% (P = 0.014), whereas this effect was absent for PET (90%, P = 0.77). Annualized event rates for images interpreted as normal did not differ and varied between 0.7 and 2.0% (P > 0.084). CONCLUSION: Adding CACS correctly increased the percentage of normal scans for SPECT MPI but not for PET, possibly limiting the effect of adding CACS to reporting PET.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Cálcio , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagem de Perfusão do Miocárdio/métodos , Estudos Retrospectivos , Radioisótopos de Rubídio , Tomografia Computadorizada de Emissão de Fóton Único/métodos
8.
Ann Nucl Med ; 35(3): 378-385, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33471288

RESUMO

PURPOSE: Our aim was to develop and validate a machine learning (ML)-based approach for interpretation of I-123 FP-CIT SPECT scans to discriminate Parkinson's disease (PD) from non-PD and to determine its generalizability and clinical value in two centers. METHODS: We retrospectively included 210 consecutive patients who underwent I-123 FP-CIT SPECT imaging and had a clinically confirmed diagnosis. Linear support vector machine (SVM) was used to build a classification model to discriminate PD from non-PD based on I-123-FP-CIT striatal uptake ratios, age and gender of 90 patients. The model was validated on unseen data from the same center where the model was developed (n = 40) and consecutively on data from a different center (n = 80). Prediction performance was assessed and compared to the scan interpretation by expert physicians. RESULTS: Testing the derived SVM model on the unseen dataset (n = 40) from the same center resulted in an accuracy of 95.0%, sensitivity of 96.0% and specificity of 93.3%. This was identical to the classification accuracy of nuclear medicine physicians. The model was generalizable towards the other center as prediction performance did not differ thereby obtaining an accuracy of 82.5%, sensitivity of 88.5% and specificity of 71.4% (p = NS). This was comparable to that of nuclear medicine physicians (p = NS). CONCLUSION: ML-based interpretation of I-123-FP-CIT scans results in accurate discrimination of PD from non-PD similar to visual assessment in both centers. The derived SVM model is therefore generalizable towards centers using comparable acquisition and image processing methods and implementation as diagnostic aid in clinical practice is encouraged.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Doença de Parkinson/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Nucl Cardiol ; 28(4): 1536-1544, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31485963

RESUMO

BACKGROUND: Clinical practice shows degrading image quality in heavier patients who undergo myocardial perfusion imaging (MPI) with Rubidium-82 (Rb-82) PET when using a fixed tracer activity. Our aim was to derive and validate a patient-specific activity protocol resulting in a constant image quality in PET MPI. METHODS: We included 251 patients who underwent rest MPI with Rb-82 PET (Discovery 670, GE Healthcare). 132 patients were included retrospectively and were scanned using a fixed activity of 740 MBq. The total number of measured prompts was normalized to activity and correlated to body weight, mass per body length and body mass index to find the best predicting parameter. Next, a patient-specific activity was derived and subsequently validated in 119 additional patients. Image quality was scored by three experts on a four-point scale. RESULTS: Both image quality and prompts decreased in heavier patients when using a fixed activity (p < .005). Body weight was used to derive a new activity formula: Activity = 8.3 MBq/kg. When applying this formula, both measured prompts and scored image quality became independent of body weight (p > .60). CONCLUSION: Administrating a Rb-82 activity that linearly depends on body weight resulted in a constant image quality across all patients and is recommended.


Assuntos
Peso Corporal , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Radioisótopos de Rubídio/farmacocinética , Idoso , Índice de Massa Corporal , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
J Nucl Cardiol ; 26(3): 746, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30847854

RESUMO

Due to the typesetter not carrying out the author's corrections at proof stage, there are two errors in the published article: where "mL × min × g" appears, it should be "mL/min/g". One error is in the Figure 3 caption, and one error is in the second sentence under the heading "MBF Quantification". The original article has been corrected.

12.
J Nucl Cardiol ; 26(3): 719-728, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30788758

RESUMO

BACKGROUND: Repositioning of the heart during myocardial perfusion imaging (MPI) using Rubidium-82 (Rb-82) PET may occur when using regadenoson. Our aim was to determine the prevalence and the effect of correcting for this myocardial creep on myocardial blood flow (MBF) quantification. METHODS: We retrospectively included 119 consecutive patients who underwent dynamic rest- and regadenoson-induced stress MPI using Rb-82 PET. The presence of myocardial creep was visually assessed in the dynamic stress PET series by identifying differences between the automatically drawn myocardium contour and the activity. Uncorrected and corrected stress MBFs were compared for the three vascular territories (LAD, LCX, and RCA) and for the whole myocardium. RESULTS: Myocardial creep was observed in 52% of the patients during stress. Mean MBF values decreased after correction in the RCA from 4.0 to 2.7 mL/min/g (P  < 0.001), in the whole myocardium from 2.7 to 2.6 mL/min/g (P  = 0.01), and increased in the LAD from 2.5 to 2.6 mL/min/g (P  = 0.03) and remained comparable in the LCX (P  = 0.3). CONCLUSIONS: Myocardial creep is a frequent phenomenon when performing regadenoson-induced stress Rb-82 PET and has a significant impact on MBF values, especially in the RCA territory. As this may hamper diagnostic accuracy, myocardial creep correction seems necessary for reliable quantification.


Assuntos
Agonistas do Receptor A2 de Adenosina/farmacologia , Coração/efeitos dos fármacos , Imagem de Perfusão do Miocárdio , Movimentos dos Órgãos/efeitos dos fármacos , Tomografia por Emissão de Pósitrons , Purinas/farmacologia , Pirazóis/farmacologia , Idoso , Circulação Coronária , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Radioisótopos de Rubídio
13.
J Nucl Cardiol ; 26(3): 729-734, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30788759

RESUMO

Reliability of myocardial blood flow (MBF) quantification in myocardial perfusion imaging (MPI) using PET can majorly be affected by the occurrence of myocardial creep when using pharmacologically induced stress. In this paper, we provide instructions on how to detect and correct for myocardial creep. For example, in each time frame of the PET images the myocardium contour and the observed activity have to be compared to check for misalignments. In addition, we provide an overview of the functionality of commonly used software packages to perform this quality control step as not all software packages currently provide this functionality. Furthermore, important clinical considerations to obtain accurate MBF measurements are given.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Movimentos dos Órgãos , Tomografia por Emissão de Pósitrons , Radioisótopos de Rubídio , Humanos , Reprodutibilidade dos Testes
14.
J Nucl Cardiol ; 26(3): 738-745, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30790203

RESUMO

BACKGROUND: Regadenoson-induced stress causes a repositioning of the heart, myocardial creep, in half of the patients undergoing Rubidium-82 (Rb-82) positron emission tomography (PET). As a result, misalignment of dynamic PET and computer tomography (CT) may occur, possibly affecting CT-based attenuation correction (AC) and thereby PET-based myocardial blood flow (MBF) quantification. Our aim was to determine the need for frame-wise PET-CT AC to obtain reliable MBF measurements. METHODS: 31 Out of 64 consecutive patients had myocardial creep during regadenoson-induced stress Rb-82 PET-CT and were included. Prior to PET image reconstruction, we applied two AC methods; single PET-CT alignment and frame-wise alignment in which PET time-frames with myocardial creep were individually co-registered with CT. The PET-CT misalignment was then quantified and MBFs for the three vascular territories and whole myocardium were calculated and compared between both methods. RESULTS: The magnitude of misalignment due to myocardial creep was 13.8 ± 4.5 mm in caudal-cranial direction, 1.8 ± 2.1 mm in medial-lateral and 2.5 ± 1.8 mm in anterior-posterior direction. Frame-wise PET-CT registration did not result in different MBF measurements (P ≥ .07) and the magnitude of misalignment and MBF differences did not correlate (P ≥ .58). CONCLUSION: There is no need for frame-wise AC in dynamic Rb-82 PET for MBF quantification. Single alignment seems sufficient in patients with myocardial creep.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Movimentos dos Órgãos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos de Rubídio , Idoso , Circulação Coronária , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Eur J Nucl Med Mol Imaging ; 46(6): 1248-1256, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30411141

RESUMO

PURPOSE: Guidelines propose different rest-stress activity ratios (RSAR) for one-day stress-first SPECT myocardial perfusion imaging (MPI), but evidence is limited. Our aim was to determine and validate the minimal RSAR resulting in the same diagnostic outcome in one-day stress-first SPECT MPI. METHODS: Forty-seven patients referred for rest after stress CZT-SPECT/CT MPI were prospectively included. Rest acquisitions were performed 3 h after stress. In addition to the stress and rest acquisitions, the first 22 patients underwent an additional acquisition prior to the rest injection to determine the remaining stress activity. Next, we simulated six RSARs varying from 1.0 to 3.5 in both patients and a phantom and compared the images to those using the reference RSAR of 4.0. Differences in summed difference score (SDS) >2 or ischemic defect interpretation were considered to significantly influence diagnostic outcome. After deriving the minimal RSAR, it was validated in 25 additional patients by comparing it to a RSAR of 4.0. RESULTS: After 3 h only 26% of the stress activity was still present in the myocardium. SDS differences >2 were found in one (4%) patient using RSAR of 3.5, 2.5 and 2.0, in three (12%) using 1.5 and in five (20%) using SRAR of 1.0. These results were consistent with the phantom study showing SDS differences >2 for RSARs ≤1.5 and with the visual interpretation which showed an increased number of deviating scans for RSAR 1.0. Validating the RSAR of 2.0 resulted in a different SDS in one patient (SDS of 30 versus 11). Moreover, two scans were interpreted as ischemic instead of normal when using RSAR 2.0 and in two other scans the opposite was the case. CONCLUSIONS: A RSAR of 2.0 in one-day stress-first MPI SPECT seems sufficient to obtain accurate diagnostic outcomes and is therefore recommended to reduce radiation exposure.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Algoritmos , Cádmio/química , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Imagens de Fantasmas , Estudos Prospectivos , Cintilografia , Descanso , Telúrio/química , Zinco/química
16.
Eur J Radiol ; 105: 251-254, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30017290

RESUMO

OBJECTIVES: Validation of a pressure-standardized compression mammography (PSCM) system, which aims to reduce discomfort and pain by applying the same pressure to every breast, independent of breast size. METHODS: We retrospectively studied mammograms of 39 patients acquired with a conventional force-standardized compression mammography (FSCM) technique and intra-individually compared them to mammograms acquired on a checkup visit with PSCM technique. Patients received one craniocaudal (CC) and one mediolateral oblique (MLO) compression for both breasts. All images were processed to obtain the contact area between the breast and the compression paddle. The pressure was calculated by dividing the compression force by the contact area. RESULTS: A total of 150 FSCM and 150 PSCM images were analyzed. The mean pressure decreased significantly from 17.1 to 12.8 kPa (p < 0.001), when using PSCM instead of FSCM. The applied pressure hardly depended on the breast contact area with the paddle (-0.014 kPa/cm2), while a clear dependency was observed using FSCM. Furthermore, the relative number of over-compressions reduced from 26% to 2%, benefitting patients with smaller breasts. CONCLUSIONS: Our study suggests that using PSCM can reduce patient discomfort and pain during mammographic compression compared to conventional FSCM as a result of lower average pressure. Moreover, standardized pressure may provide a more constant image quality, which could improve diagnostic performance.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Mamografia/instrumentação , Dor/etiologia , Pressão/efeitos adversos , Adulto , Idoso , Feminino , Humanos , Mamografia/efeitos adversos , Mamografia/métodos , Pessoa de Meia-Idade , Medição da Dor , Estudos Retrospectivos , Resultado do Tratamento
17.
J Nucl Cardiol ; 25(1): 26-35, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28822102

RESUMO

BACKGROUND: SPECT Myocardial perfusion imaging (MPI) is associated with a relatively high radiation burden and decreasing image quality in heavy patients. Patient-specific low-activity protocols (PLAPs) are suggested but follow-up data is lacking. Our aim was to compare the use of a standard fixed-activity protocol (FAP) with a PLAP in cadmium zinc telluride (CZT)-SPECT MPI. METHODS: We retrospectively included 1255 consecutive patients who underwent CZT-SPECT stress-optional rest MPI. 668 Patients were scanned using FAP (370 MBq) and 587 patients using PLAP (2.25 MBq·kg-1). Percentage of scans interpreted as normal, radiation dose, and 1-year follow-up including hard event rates (all-cause death or non-fatal myocardial infarction) were collected and compared. RESULTS: The percentage of scans interpreted as normal was 67% in FAP and 70% in PLAP groups (P = .29). The annualized hard event rates in these patients were 1.0% in the FAP and 0.9% in the PLAP group (P = .86). However, the mean radiation dose decreased by 23% for stress-only and by 15% to 2.6 mSv for stress-optional rest MPI after introduction of the PLAP (p<0.001). CONCLUSIONS: Introduction of a patient-specific low-activity protocol does not affect the percentage of scans interpreted as normal or prognosis but significantly lowers the radiation dose for CZT-SPECT MPI.


Assuntos
Cádmio , Imagem de Perfusão do Miocárdio , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Peso Corporal , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Seguimentos , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Doses de Radiação , Cintilografia , Compostos Radiofarmacêuticos/farmacologia , Estudos Retrospectivos
19.
J Nucl Cardiol ; 24(2): 395-401, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26780528

RESUMO

BACKGROUND: Attenuation correction (AC) improves the diagnostic outcome of stress-only myocardial perfusion imaging (MPI) using conventional SPECT. Our aim was to determine the value of AC using a cadmium zinc telluride-based (CZT)-SPECT camera. METHODS AND RESULTS: We retrospectively included 107 consecutive patients who underwent stress-optional rest MPI CZT-SPECT/CT. Next, we created three types of images for each patient; (1) only displaying reconstructed data without the CT-based AC (NC), (2) only displaying AC, and (3) with both NC and AC (NC + AC). Next, two experienced physicians visually interpreted these 321 randomized images as normal, equivocal, or abnormal. Image outcome was compared with all hard events over a mean follow-up time of 47.7 ± 9.8 months. The percentage of images interpreted as normal increased from 45% using the NC images to 72% using AC and to 67% using NC + AC images (P < .001). Hard event hazard ratios for images interpreted as normal were not different between using NC and AC (1.01, P = .99), or NC and NC + AC images (0.97, P = .97). CONCLUSIONS: AC lowers the need for additional rest imaging in stress-first MPI using CZT-SPECT, while long-term patient outcome remained identical. Use of AC reduces the need for additional rest imaging, decreasing the mean effective dose by up to 1.2 mSv.


Assuntos
Artefatos , Teste de Esforço/instrumentação , Aumento da Imagem/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/mortalidade , Imagem de Perfusão do Miocárdio/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Algoritmos , Cádmio/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Variações Dependentes do Observador , Prevalência , Prognóstico , Cintilografia/instrumentação , Cintilografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taxa de Sobrevida , Telúrio/efeitos da radiação , Zinco/efeitos da radiação
20.
Int J Cardiovasc Imaging ; 32(3): 531-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26563107

RESUMO

To derive and validate a practical patient-specific dose protocol to obtain an image quality, expressed by the image noise, independent of patients' size and a better radiation dose justification in coronary CT angiography (CCTA) using prospective ECG triggering. 43 patients underwent clinically indicated CCTA. The image noise, defined as the standard deviation of pixel attenuation values in a homogeneous region in the liver, was determined in all scans. Subsequently, this noise was normalized to the radiation exposure. Next, three patient-specific parameters, body weight, body mass index and mass per length (MPL), were tested for the best correlation with normalized image noise. From these data, a new dose protocol to provide a less variable image noise was derived and subsequently validated in 84 new patients. The normalized image noise increased for heavier patients for all patients' specific parameters (p < 0.001). MPL correlated best with the normalized image noise and was selected for dose protocol optimization. This new protocol resulted in image noise levels independent of patients' MPL (p = 0.28). A practical method to obtain CCTA images with noise levels independent of patients' MPL was derived and validated. It results in a less variable image quality and better radiation exposure justification and can also be used for CT scanners from other vendors.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Exposição à Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS