Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Frailty Aging ; 3(4): 222-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27048861

RESUMO

BACKGROUND: Sarcopenia is probably an important causal factor for functional decline in acutely ill hospitalized geriatric patients. Low skeletal muscle mass, low gait speed and low grip strength are hallmarks of diagnosing sarcopenia. However there are many different diagnostic criteria to assess sarcopenia. OBJECTIVES: In this study the influence of different criteria for sarcopenia was studied on sarcopenia prevalence in geriatric patients admitted to an acute care hospital. DESIGN: Cross sectional study design. SETTING: A geriatric ward of a large Dutch hospital. PARTICIPANTS: Geriatric patients. MEASUREMENTS: Skeletal muscle mass measured using bio impedance analysis (BIA), gait speed using the 4 meter walking test and grip strength. The sarcopenia prevalence was investigated according to criteria of: muscle mass, grip strength, the European Working Group on Sarcopenia in Elderly People, the International Working Group on Sarcopenia and the Special Interest Group of Society of Sarcopenia, Cachexia and Wasting Disorders. RESULTS: 85 geriatric patients were included (61 women). Applying the 17 different criteria, the sarcopenia prevalence varied from 26-75% for women and from 42-100% for men. Comparing the Janssen calculation with the Maltron calculation sarcopenia prevalence ranged from respectively 26-67% and 67-70% for women and from 42-71% and 75-100% for men. Almost all patients (96%) had a low gait speed. CONCLUSIONS: Sarcopenia is highly prevalent in an acute hospitalized geriatric population, although the prevalence varies widely depending on the diagnostic criteria applied. A prospective study is needed to discover which criteria of sarcopenia can predict best adverse outcomes.

2.
Neth Heart J ; 15(4): 133-41, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17612673

RESUMO

BACKGROUND: The use of invasive procedures has mostly been studied in retrospective (multi)- national registries. Limited evidence exists on the association between microalbuminuria and coronary artery disease (CAD). METHODS: The incidence of major adverse cardiac events (MACE) and invasive cardiac procedures was registered between 1997 and 2003 in 8139 subjects, without prior documented CAD, in the PREVEND cohort study (the Netherlands), in which the focus is on microalbuminuria and cardiovascular risk. Qualitative coronary angiographic analysis was performed. RESULTS: During 5.5 years of follow-up, a first MACE occurred in 271 (3.3%) and a first coronary angiography (CAG) was performed in 264 (3.2%) subjects. Of these, 216 CAGs were available for qualitative angiographic analysis. Indications for CAG were stable angina in 129, acute coronary syndrome (ACS) in 55 and ST-elevation myocardial infarction (STEMI) in 32 subjects. Obstructive coronary artery disease was present in 61, 53 and 30 subjects, respectively. A revascularisation was performed in 50 (39%), 50 (91%) and 25 (78%) subjects, respectively. Microalbuminuria was associated with a first MACE, after adjustment for established risk factors. Microalbuminuria was present at baseline in 9% of subjects with normal coronary arteries, in 21% of subjects with one- and two-vessel CAD and in 39% of subjects with threevessel or left main CAD at CAG during follow-up (Ptrend=0.005). CONCLUSION: This large cohort study shows that two-thirds of diagnostic CAGs for stable angina were not followed by a revascularisation, in contrast to CAGs for STEMI or ACS. Furthermore, this study shows that microalbuminuria is associated with CAD. (Neth Heart J 2007;15:133-41.).

3.
Int J Clin Pharmacol Ther ; 43(11): 507-16, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16300166

RESUMO

BACKGROUND: Chronic heart failure (CHF) is a potential indication for the administration of EMD 87 580, a selective Na+/H+ exchange inhibitor. CHF is often accompanied by renal dysfunction, which is known to affect the pharmacokinetics of compounds predominately cleared by the kidneys. We examined the influence of renal dysfunction on the pharmacokinetics of EMD 87 580 in patients with CHF. METHODS: 21 patients with CHF and normal renal function (Group 1) and 9 patients with CHF and renal dysfunction (Group 2) received EMD 87 580 orally over 8 days. The mean creatinine clearance (CrCl) in Group 1 was 99.7 ml/min. 12 patients in this group were randomized to receive two doses of EMD 87 580 (7 patients 2 x 50 mg and 5 patients 2 x 100 mg). The 9 patients in Group 2 with renal dysfunction (mean CrCl = 49.5 ml/min) received 50 mg EMD 87 580 once daily. Plasma and urine samples were collected for pharmacokinetic assessment. RESULTS: In CHF patients with renal dysfunction EMD 87 580 clearance was reduced to approximately 50% compared to Group 1, i.e. 6.80 ml/min (4.89-11.60) vs. 12.73 ml/min (8.93-22.21), p < 0.05, for the 50 mg dose and 14.08 ml/min (9.96-18.10), p < 0.05, for the 100 mg dose. Consequently, plasma concentrations were increased in patients with renal dysfunction; AUC0-infinity 7,354 ng/ml x h (4,311-10,232) vs. 3,928 ng/ml x h (2,251-5,596, 50 mg dose, p < 0.05). A significant correlation was observed between EMD 87 580 plasma clearance and CrCl (r2 = 0.8062). CONCLUSION: In CHF patients with renal dysfunction EMD 87 580, clearance is reduced and plasma concentrations increased. Therefore, dose adjustments for EMD 87 580 are indicated in patients with CHF and renal dysfunction.


Assuntos
Guanidinas/farmacocinética , Nefropatias/metabolismo , Sulfonas/farmacocinética , Idoso , Creatinina/metabolismo , Feminino , Taxa de Filtração Glomerular , Guanidinas/sangue , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Trocadores de Sódio-Hidrogênio/antagonistas & inibidores , Sulfonas/sangue
4.
Catheter Cardiovasc Interv ; 50(3): 314-21, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10878628

RESUMO

A crossover study was performed to compare the hemodynamic effects of the iso-osmolar contrast agent iodixanol (Visipaque) 320 mg I/ml to those of the low-osmolar iohexol (Omnipaque) 350 mg I/ml. The main hypothesis was that iodixanol and iohexol would affect left ventricular end-diastolic pressure (LVEDP) to different degrees. In 48 patients with reduced cardiac function (mean ejection fraction 33. 4%), one ventricular injection was performed with each contrast medium. Ventricular, aortic and right atrial pressures and heart rate were measured continuously. Cardiac output (using Fick's principle) and systemic vascular resistance were calculated. LVEDP increased with both agents, but significantly less after iodixanol than after iohexol (P < 0.01), also in subgroups of patients in whom baseline LVEDP was severely increased and in whom 3-vessel disease was present. Immediate changes in variables reflecting vasodilatation were similar with both agents. In conclusion, both contrast agents influenced hemodynamics during ventriculography, but iodixanol had significantly less influence on LVEDP than did iohexol.


Assuntos
Meios de Contraste/farmacologia , Hemodinâmica/efeitos dos fármacos , Iohexol/farmacologia , Ácidos Tri-Iodobenzoicos/farmacologia , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Ventricular/efeitos dos fármacos , Adulto , Idoso , Angiocardiografia , Cateterismo Cardíaco , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Cardiovasc Pharmacol ; 29(5): 618-23, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9213204

RESUMO

In this study, the hemodynamic and neurohumoral/autonomic effects of intravenous saterinone (a selective phosphodiesterase type III inhibitor, with additional alpha 1-blocking properties) were evaluated. In a double-blind, placebo-controlled design, 36 patients with moderate to severe heart failure were studied (saterinone, n = 24; placebo, n = 12). Invasive hemodynamic measurements, by using right-heart catheterization, were performed, as well as measurement of plasma neurohormones and analysis of heart rate variability (HRV), to study drug influences on neurohumoral activation and autonomic tone. Systemic vascular resistance significantly decreased during saterinone infusion, accompanied by a decrease in systemic blood pressure (both p values < 0.05) and an increase in heart rate (p = 0.05). Filling pressures also decreased during saterinone, but this was statistically significant only for pulmonary capillary wedge pressure, whereas the cardiac index remained unaffected. Plasma neurohormones (norepinephrine, epinephrine, and renin activity) were not significantly influenced by saterinone. HRV analysis revealed no significant effect of saterinone on autonomic tone. These results suggest that intravenous saterinone has a significant vasodilating effect in patients with moderate to severe chronic heart failure (CHF), without exerting an adverse effect on the autonomic nervous system, as demonstrated by assessment of plasma neurohormones and HRV analysis.


Assuntos
Sistema Nervoso Autônomo/efeitos dos fármacos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Inibidores de Fosfodiesterase/uso terapêutico , Piperazinas/uso terapêutico , Piridonas/uso terapêutico , Idoso , Método Duplo-Cego , Eletrocardiografia/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Neurotransmissores/sangue , Inibidores de Fosfodiesterase/administração & dosagem , Piperazinas/administração & dosagem , Piridonas/administração & dosagem
6.
Cathet Cardiovasc Diagn ; 37(3): 233-40; discussion 241-2, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8974796

RESUMO

Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty (PTCA)-with an autoperfusion balloon or active system-facilitates prolonged balloon inflation. Prolonged inflations may tack up intimal dissections and improve the primary angioplasty result in complex lesions. Additionally, distal perfusion may reduce the likelihood of cardiogenic shock during high-risk PTCA. Autoperfusion balloons are most frequently used to treat acute or threatened closure. There currently is no prospective clinical study showing that stent implantation for this complication is more successful and more cost-effective. The blood flow rates through autoperfusion balloons may not abolish myocardial ischemia, and higher flow rates can often be achieved with pumps. Therefore, during high-risk PTCA, pumps may be preferred to prevent hemodynamic collapse. Clinical application of perfusion pumps is hampered by the risk for mechanical hemolysis during prolonged perfusion and the high velocity of the bloodstream that exits the PTCA catheter, causing distal vessel wall trauma.


Assuntos
Angioplastia Coronária com Balão , Coração Auxiliar , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco , Cateterismo , Circulação Coronária , Humanos , Reperfusão Miocárdica/instrumentação , Reperfusão Miocárdica/métodos , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Choque Cardiogênico/prevenção & controle , Stents
7.
Eur Heart J ; 16(5): 698-703, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7588904

RESUMO

This study was performed because of observed differences between dye dilution cardiac output and the Fick cardiac output, calculated from estimated oxygen consumption according to LaFarge and Miettinen, and to find a better formula for assumed oxygen consumption. In 250 patients who underwent left and right heart catheterization, the oxygen consumption VO2 (ml.min-1) was calculated using Fick's principle. Either pulmonary or systemic flow, as measured by dye dilution, was used in combination with the concordant arteriovenous oxygen concentration difference. In 130 patients, who matched the age of the LaFarge and Miettinen population, the obtained values of oxygen consumption VO2(dd) were compared with the estimated oxygen consumption values VO2(lfm), found using the LaFarge and Miettinen formulae. The VO2(lfm) was significantly lower than VO2(dd); -21.8 +/- 29.3 ml.min-1 (mean +/- SD), P < 0.001, 95% confidence interval (95% CI) -26.9 to -16.7, limits of agreement (LA) -80.4 to 36.9. A new regression formula for the assumed oxygen consumption VO2(ass) was derived in 250 patients by stepwise multiple regression analysis. The VO2(dd) was used as a dependent variable, and body surface area BSA (m2). Sex (0 for female, 1 for male), Age (years), Heart rate (min-1) and the presence of a left to right shunt as independent variables. The best fitting formula is expressed as: VO2(ass) = (157.3 x BSA + 10.0 x Sex - 10.5 x In Age + 4.8) ml.min-1, where ln Age = the natural logarithm of the age. This formula was validated prospectively in 60 patients. A non-significant difference between VO2(ass) and VO2(dd) was found; mean 2.0 +/- 23.4 ml.min-1, P = 0.771, 95% Cl = -4.0 to +8.0, LA -44.7 to +48.7. In conclusion, assumed oxygen consumption values, using our new formula, are in better agreement with the actual values than those found according to LaFarge and Miettinen's formulae.


Assuntos
Débito Cardíaco/fisiologia , Corantes , Cardiopatias/diagnóstico , Consumo de Oxigênio/fisiologia , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Técnica de Diluição de Corante , Feminino , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Humanos , Masculino , Análise de Regressão
8.
Am J Cardiol ; 74(10): 1002-5, 1994 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-7977036

RESUMO

Efficacy and major clinical end points were compared in 61 patients treated with a Stack autoperfusion balloon versus 36 patients who received a Palmaz-Schatz stent for acute or threatened closure during coronary angioplasty. The groups were comparable regarding baseline clinical characteristics. Procedural success was achieved in 43 patients (70%) treated with an autoperfusion balloon versus 34 patients (94%) who received a stent (p < 0.02). Emergency bypass surgery was performed in 13 patients (21%) with the autoperfusion balloon versus none of the patients with a stent (p < 0.001). In the stent group, 3 patients (8%) died (p < 0.05); 2 deaths were caused by thrombotic reclosure, and 1 patient died after unsuccessful stent delivery. Subacute reclosure during hospitalization occurred in none of the patients with autoperfusion versus 8 patients with the stent (22%) (p < 0.0002). Therefore, the number of patients with successful stent implantation at discharge decreased to 26 (72%). At 3-month follow-up in all patients with a successful intervention, reclosure or angiographic restenosis (> 50%) occurred in 13 patients with autoperfusion (30%) versus 3 patients with stents (12%) (p = NS). There was no difference in event-free survival during follow-up. Thus, both interventions were equally successful in the treatment of acute and threatened closure. More emergency surgery was performed in the autoperfusion balloon group, whereas a higher subacute reclosure rate was seen in the stent group. At 3-month follow-up, there were no significant differences regarding reclosure, restenosis, and event-free survival.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Doença das Coronárias/terapia , Reperfusão Miocárdica/instrumentação , Stents , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva
9.
J Interv Cardiol ; 7(6): 525-34, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10155200

RESUMO

Laser thrombolysis is a new, experimental, catheter based intervention aimed at selectively removing intracoronary thrombus. This first clinical study was performed to assess the feasibility and safety of laser thrombolysis, as well as its potential therapeutic place in acute myocardial infarction. Eighteen patients with acute myocardial infarction, who were either noncandidates for, or failures on, intravenous fibrinolytic therapy were included for treatment with laser thrombolysis followed by balloon angioplasty. As a result of catheter and technical failures, the laser was actually fired in only 12 patients. Improvement in TIMI flow from grade 0-1 to grade 2-3 was observed in 10 of these 12 patients after laser application. The overall results of 18 patients were: increase in TIMI grade flow from 0.33 +/- 0.49 after wire passage to 1.28 +/- 1.23 (P = 0.0051) after attempted laser application, and to 2.67 +/- 0.97 after PTCA (P = 0.0004). Two patients with previous infarctions died from left ventricular failure despite successful laser thrombolysis. One patient died during emergency bypass surgery after a failed recanalization attempt. Perforation or laser related dissection did not occur. The concept of selective laser thrombus ablation seems to be safe and feasible, but substantial improvements of the laser delivery catheters are needed. Laser thrombolysis is not an effective stand-alone therapy in acute myocardial infarction, but other possible applications warrant further research and development efforts for this potentially useful interventional tool.


Assuntos
Angioplastia Coronária com Balão , Angioplastia com Balão a Laser , Trombose Coronária/cirurgia , Infarto do Miocárdio/cirurgia , Terapia Combinada , Angiografia Coronária , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/terapia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Terapia Trombolítica
10.
Am Heart J ; 128(4): 656-63, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7942435

RESUMO

Percutaneous coronary angioscopy was used in 13 patients in a pilot study to assess the intracoronary changes that occur during the first hour after balloon angioplasty (PTCA). The dilated segment was studied with 4.5F angioscopes and with quantitative coronary angiography (QCA) immediately after PTCA and at 15-minute intervals for up to 1 hour after PTCA. Significant progression of intimal dissection and thrombus formation could be demonstrated with angioscopy. These dissections and thrombi remained undetected with angiography, which only showed haziness. Thus through its superior sensitivity to intimal damage and thrombus, coronary angioscopy can reveal important intravascular events that apparently occur even after successful PTCA. The relation of such angioscopic observations to restenosis will be addressed in a subsequent multicenter study.


Assuntos
Angioplastia Coronária com Balão , Angioscopia , Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/terapia , Vasos Coronários/patologia , Angioscopia/métodos , Trombose Coronária/patologia , Estudos de Avaliação como Assunto , Humanos , Projetos Piloto , Recidiva , Fatores de Tempo , Túnica Íntima/lesões , Túnica Íntima/patologia
11.
J Am Coll Cardiol ; 24(3): 649-54, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8077534

RESUMO

OBJECTIVES: This study was undertaken to compare coronary angioscopy with angiography for the detection of intimal dissection and intracoronary thrombus. BACKGROUND: It has been demonstrated previously that coronary angioscopy provides more intravascular detail than cineangiography. Both imaging methods have to be compared directly to assess the additional diagnostic value of angioscopy. METHODS: The angiograms and videotapes of 52 patients who had undergone angioscopy were reviewed independently by two observers unaware of other findings. Classic angiographic definitions were used for dissection and thrombus. Angioscopic dissection was defined as visible cracks or fissures on the lumen surface or mobile protruding structures that are contiguous with the vessel wall. Angioscopic thrombus was defined as a red, white or mixed red and white intraluminal mass. RESULTS: Angiography and angioscopy were in agreement in 40.4% of cases in the absence of thrombus and in 11.5% in the presence of thrombus. No fewer than 25 (48.1%) angioscopically observed thrombi remained undetected at angiography. With angioscopy as the standard, although the specificity of angiography for thrombus was 100%, sensitivity was very low at 19%. Angioscopic dissection was present in 40 patients (76.9%) versus angiographic dissection in 15 patients (28.8%). With regard to dissection, there was no correlation between the two imaging methods (r phi = 0.15, p = 0.29). CONCLUSIONS: Coronary angiography underestimates the presence of intracoronary thrombus. Angioscopy and angiography are complementary techniques for detecting and grading intimal dissections.


Assuntos
Angioscopia , Dissecção Aórtica/diagnóstico , Aneurisma Coronário/diagnóstico , Angiografia Coronária , Trombose Coronária/diagnóstico , Vasos Coronários , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Coronário/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
12.
Artif Organs ; 18(7): 517-22, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7980096

RESUMO

Hemolysis tests with fresh human blood were performed in vitro with a new 5 ml, piston-type hemoperfusion pump, designed to prevent myocardial ischemia during coronary angioplasty. Despite driving pressures greater than 3 atmospheres, shear stress greater than 200 Pa, turbulent pump flow, and the presence of occlusive valves, hemolysis proved to be minimal. This effect is explained by the short amount of time that blood is subjected to mechanical forces that cause hemolysis in the system and by the small volumes of blood involved. During clinical application of the system, angina pectoris, electrocardiographic changes, and systemic blood pressure were used as parameters for myocardial ischemia. There was an effective reduction of ischemia during prolonged (10 min) balloon inflation, demonstrated by the absence of angina, minimal electrocardiographic changes, and normal blood pressure. In addition, the system proved to be safe and effective during high-risk angioplasty.


Assuntos
Angioplastia Coronária com Balão , Hemoperfusão/instrumentação , Adulto , Idoso , Angina Pectoris/prevenção & controle , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Viscosidade Sanguínea , Doença das Coronárias/terapia , Eletrocardiografia , Desenho de Equipamento , Europa (Continente) , Hemólise , Hemorreologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Isquemia Miocárdica/prevenção & controle , Pressão
13.
Eur Heart J ; 15(6): 815-22, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8088271

RESUMO

A European coronary angioscopy working group has been established to create and evaluate a classification system for angioscopic observation. The 'Ermenonville' classification features items, graded in 3-5 categories, such as lumen diameter, shape of narrowing, colours of surface, atheroma, dissection, thrombus, etc. Inter- and intra-observer agreement on the interpretation of angioscopic images, using this classification system, was studied within the working group. Kappa values for chance-corrected intra-observer agreement of the diagnostic items were 0.51-0.67. The mean kappa values for inter-observer agreement were very low at 0.13-0.29. The important items, such as red thrombus and dissection were studied after recoding as either present or absent. These items proved to have a good intra-observer agreement, and an acceptable inter-observer agreement after recoding. Other angioscopic diagnoses should be made with caution. Multicentre angioscopy studies should make use of an angioscopy core laboratory. A set of definitions for coronary angioscopy is proposed, and this working group will re-evaluate observer agreements using these definitions.


Assuntos
Angioscopia , Doença das Coronárias/epidemiologia , Vasos Coronários/patologia , Angioscopia/classificação , Angioscopia/estatística & dados numéricos , Doença das Coronárias/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiologia Intervencionista
15.
Cathet Cardiovasc Diagn ; 30(1): 58-62, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8402868

RESUMO

The effective flow rates with human blood through an autoperfusion catheter cannot be monitored in vivo and have not been experimentally determined in vitro. The manufacturers (Advanced Cardiovascular Systems [ACS], Temecula, CA) have suggested that "the flow rate" through the Stack over the wire and the RX-60 monorail catheter is 60 ml/min with a pressure gradient of 80 mmHg. We measured human blood flow rates in vitro through these catheters under different continuous pressure regimens (between 40 and 120 mmHg), with varying hematocrit levels (between 25% and 62%). Measured blood flows at a gradient of 80 mmHg were found to vary from 32 to 65 cc/min, with hematocrit levels of 62-25%. Minor variations in the circuitry, besides the viscosity of the medium, cause significant changes in observed flow rates (such as kinking of the catheter and blood sedimentation). In vitro determinations of blood flows cannot automatically be transferred to the in vivo condition, primarily because in vitro determinations do not account for the systolic intramural pressure increase (which may overcome the aortic pressure). If such a phenomenon is also considered, then the in vitro flow rates reported here should be multiplied by a factor of 0.40-0.60 to determine effective in vivo flow rates. Such information is relevant for the clinical operator of angioplasty, especially in the treatment of patients at high risk for undergoing percutaneous transluminal coronary angioplasty.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Circulação Coronária/fisiologia , Reologia , Ponte Cardiopulmonar , Humanos , Modelos Cardiovasculares , Modelos Estruturais , Perfusão/instrumentação
16.
J Cardiovasc Pharmacol ; 22(2): 215-20, 1993 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7692160

RESUMO

The influence of intravenous diltiazem on hemodynamics and left ventricular function indices was studied in 14 patients with severe coronary artery disease at rest and during atrial pacing. We used a tip manometer catheter for recording left ventricular pressure tracings and a nuclear probe for measuring left ventricular volume changes. Infusion of diltiazem at rest resulted in an increase in left ventricular enddiastolic volume (+16%, p < 0.0001); all other parameters did not differ significantly from baseline values. Angina pectoris occurred in all patients during atrial pacing before diltiazem infusion (ContrP); during pacing after diltiazem infusion (DiltP) only four patients became symptomatic (at the same pacing rates). Other differences between the two pacing studied and their baseline measurement were mean arterial pressure (ContrP: +13%, p < 0.001; DiltP: +11% p < 0.001), pulmonary wedge pressure (ContrP: +54%, p = 0.019; DiltP: NS), left ventricular enddiastolic pressure (ContrP: +40%, p < 0.005; DiltP: NS), left ventricular enddiastolic volume (ContrP: -19%, p = 0.001; DiltP: -33%, p = 0.0001), left ventricular ejection fraction (ContrP: -20%, p = 0.039; DiltP: NS), maximum rate of rise of left ventricular systolic pressure (ContrP: +22%, p = 0.001; DiltP: +20%, p = 0.03), time constant of relaxation (ContrP: +40%, p = 0.001; DiltP +8%, p = 0.047), stiffness constant of the diastolic pressure-volume relationship (ContrP: +157%, p = 0.0001; DiltP: +132%, p = 0.001), and left ventricular systolic work (ContrP: -35%, p = 0.0001; DiltP -46%, p = 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Estimulação Cardíaca Artificial , Doença das Coronárias/tratamento farmacológico , Diltiazem/uso terapêutico , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Idoso , Angina Pectoris/tratamento farmacológico , Pressão Sanguínea/efeitos dos fármacos , Computadores , Doença das Coronárias/fisiopatologia , Diltiazem/administração & dosagem , Diltiazem/sangue , Eletrodos , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Manometria , Pessoa de Meia-Idade
17.
Cathet Cardiovasc Diagn ; 29(4): 325-8, 1993 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8221858

RESUMO

One of the possible complications of subclavian vein puncture is accidental puncture of the subclavian artery. If this is not noted immediately after the puncture, insertion of a large bore sheath in the subclavian artery is likely to follow. We describe our experience with a new method that enables successful and safe removal of such sheaths without notable blood loss, in three patients.


Assuntos
Oclusão com Balão , Cateterismo Cardíaco/instrumentação , Cateterismo Venoso Central/instrumentação , Cateterismo/instrumentação , Cardiopatias/terapia , Artéria Subclávia/lesões , Idoso , Idoso de 80 Anos ou mais , Angiografia , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Artéria Subclávia/diagnóstico por imagem
18.
Cathet Cardiovasc Diagn ; 29(2): 136-40, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8348599

RESUMO

Early occlusion of intracoronary stents has been exclusively attributed to thrombosis. Using intracoronary angioscopy, we have found 2 patients in whom this common and serious complication of coronary stenting was caused by obstructive intima dissection rather than thrombosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioscopia , Dissecção Aórtica/diagnóstico , Angiografia Coronária , Doença das Coronárias/terapia , Oclusão de Enxerto Vascular/diagnóstico , Stents , Idoso , Doença das Coronárias/diagnóstico , Trombose Coronária/diagnóstico , Trombose Coronária/terapia , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade
19.
Int J Cardiol ; 37(3): 317-27, 1992 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1468815

RESUMO

Prolonged angioplasty balloon inflation with an autoperfusion balloon for failed conventional coronary angioplasty, was compared with emergency surgery for this condition. Restenosis was assessed 6 weeks after successful intervention with the autoperfusion balloon. Forty consecutive patients with persistent acute occlusion and/or severe intimal dissection during conventional angioplasty, were treated with the autoperfusion balloon. They were candidates for emergency surgery if it failed. Total inflation time was significantly longer (p < 0.001) with the autoperfusion balloon (27.5; 10-180 min) than with the standard balloon (10; 1-20 min) (median; range). The number of inflations was significantly lower (p < 0.001) with the autoperfusion balloon (2; 1-5 times) than with the standard balloon (5; 2-14 times) (median; range). Two patients died, one before surgery could be performed. The autoperfusion balloon was successful in 26 patients (65%). After 6 weeks, 16 (62%) were asymptomatic without anti-anginal medication, 24 underwent repeat angiography, 10 (42%) had restenosis, 7 (27%) underwent elective bypass surgery. Emergency surgery remained necessary in 13 patients (33%), 9 received arterial grafts. In 31 retrospective controls, who had undergone immediate surgery for the same indication, only venous grafts could be used. Thus, prolonged autoperfusion balloon inflation was successful in 65% of the cases of failed, conventional angioplasty. The angiographic restenosis rate after 6 weeks was 42%. If emergency surgery remained necessary, the autoperfusion balloon facilitated the use of arterial bypass grafts.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Ponte de Artéria Coronária/normas , Doença das Coronárias/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/normas , Terapia Combinada , Comorbidade , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/fisiopatologia , Emergências , Feminino , Seguimentos , Hemodinâmica , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Países Baixos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Falha de Tratamento
20.
Cathet Cardiovasc Diagn ; 23(1): 47-9, 1991 May.
Artigo em Inglês | MEDLINE | ID: mdl-1863962

RESUMO

Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a single 8-F guiding catheter.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Angioplastia Coronária com Balão/instrumentação , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/terapia , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...