1.
Ann Intensive Care ; 6(1): 68, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27436191

RESUMO

BACKGROUND: Microdialysis is a well-established technology that can be used for continuous blood glucose monitoring. We determined point and trend accuracy, and reliability of a microdialysis-based continuous blood glucose-monitoring device (EIRUS(®)) in critically ill patients. METHODS: Prospective study involving patients with an expected intensive care unit stay of ≥48 h. Every 15 min, device readings were compared with blood glucose values measured in arterial blood during blocks of 8 h per day for a maximum of 3 days. The Clarke error grid, Bland-Altman plot, mean absolute relative difference and glucose prediction error analysis were used to express point accuracy and the rate error grid to express trend accuracy. Reliability testing included aspects of the device and the external sensor, and the special central venous catheter (CVC) with a semipermeable membrane for use with this device. RESULTS: We collected 594 paired values in 12 patients (65 [26-80; 8-97] (median [IQR; total range]) paired values per patient). Point accuracy: 93.6 % of paired values were in zone A of the Clarke error grid, 6.4 % were in zone B; bias was 4.1 mg/dL with an upper limit of agreement of 28.6 mg/dL and a lower level of agreement of -20.5 mg/dL in the Bland-Altman analysis; 93.6 % of the values ≥75 mg/dL were within 20 % of the reference values in the glucose prediction error analysis; the mean absolute relative difference was 7.5 %. Trend accuracy: 96.4 % of the paired values were in zone A, and 3.3 and 0.3 % were in zone B and zone C of the rate error grid. Reliability: out of 16 sensors, 4 had to be replaced prematurely; out of 12 CVCs, two malfunctioned (one after unintentional flushing by unsupervised nurses of the ports connected to the internal microdialysis chamber, causing rupture of the semipermeable membrane; one for an unknown reason). Device start-up time was 58 [56-67] min; availability of real-time data was 100 % of the connection time. CONCLUSIONS: In this study in critically ill patients who had no hypoglycemic episodes and a limited number of hyperglycemic excursions, point accuracy of the device was moderate to good. Trend accuracy was very good. The device had no downtimes, but 4 out of 16 external sensors and 2 out of 12 CVCs had practical problems.

2.
Neth J Med ; 73(10): 455-63, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26687261

RESUMO

BACKGROUND: Publication of the Normoglycemia in Intensive Care Evaluation and Survival Using Glucose Algorithm Regulation (NICE-SUGAR) trial in 2009 and several observational studies caused a change in the recommendations for blood glucose control in intensive care patients. We evaluated local trends in blood glucose control in intensive care units in the Netherlands before and after the publication of the NICE-SUGAR trial and the revised Surviving Sepsis Campaign (SSC) guidelines in 2012. METHODS: Survey focusing on the timing of changes in thresholds in local guidelines for blood glucose control and interrupted time-series analysis of patients admitted to seven intensive care units in the Netherlands from September 2008 through July 2014. Statistical process control was used to visualise and analyse trends in metrics for blood glucose control in association with the moment changes became effective. RESULTS: Overall, the mean blood glucose level increased and the median percentage of blood glucose levels within the normoglycaemic range and in the hypoglycaemic range decreased, while the relative proportion of hyperglycaemic measurements increased. Changes in metrics were notable after publication of the NICE-SUGAR trial and the SSC guidelines but more frequent after changes in local guidelines; some changes seemed to appear independent of changes in local guidelines. CONCLUSION: Local guidelines for blood glucose practice have changed in intensive care units in the Netherlands since the publication of the NICE-SUGAR trial and the revised SSC guidelines. Trends in the metrics for blood glucose control suggest new, higher target ranges for blood glucose control.


Assuntos
Cuidados Críticos/tendências , Estado Terminal , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Padrões de Prática Médica/tendências , Sistema de Registros , Idoso , Algoritmos , Glicemia , Protocolos Clínicos , Feminino , Fidelidade a Diretrizes , Humanos , Hipoglicemia/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Países Baixos , Planejamento de Assistência ao Paciente , Guias de Prática Clínica como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...