Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-12888211

RESUMO

Solid-phase extraction (SPE) was directly coupled to mass spectrometry (MS) to assess the feasibility of the system for the rapid determination of prednisolone in serum. A C(18) stationary phase allowed washing of the cartridge with 25% methanol. Elution was performed by switching the methanol percentage from 25% in the washing step to 50% during elution. The high flow-rates during the extraction (5.0 ml/min) combined with ion-trap MS detection resulted in a total analysis time of 4 min. Some tailing of the prednisolone peak was observed. However, the tailing was found acceptable, since by this elution procedure most matrix compounds were prevented from eluting from the cartridge. Some matrix interference was still observed with a triple-quadrupole MS, even in the multiple reaction monitoring mode. This resulted in a detection limit (LOD) of about 10 ng/ml. The matrix interference and the LOD were similar for atmospheric pressure chemical ionisation and atmospheric pressure photo ionisation. Applying an ion-trap MS in the MS-MS mode resulted in cleaner chromatograms. Due to extensive fragmentation of prednisolone, the LOD was not lower than about 5 ng/ml prednisolone in serum, and a limit of quantitation of about 10 ng/ml (relative standard deviation <15%) was observed.


Assuntos
Glucocorticoides/sangue , Espectrometria de Massas/métodos , Prednisolona/sangue , Humanos , Sensibilidade e Especificidade
2.
Rapid Commun Mass Spectrom ; 17(3): 245-50, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12539191

RESUMO

Ion suppression effects were observed during the determination of clenbuterol in urine with solid-phase extraction/multiple-stage ion-trap mass spectrometry (SPE/MS(3)), despite the use of atmospheric pressure chemical ionisation. During SPE, a polymeric stationary phase (polydivinylbenzene) was applied. Post-cartridge infusion of analyte to the SPE eluate after the extraction of blank urine was performed to obtain a profile of the suppression. Single and multiple-stage MS were performed to provide insight in the suppressing compounds. The ion suppression was mainly ascribed to two m/z values, but still no identification of the compounds was achieved from the multiple-stage MS data. No ionisable and non-ionisable complexes and/or precipitation of clenbuterol with matrix compounds were observed. A concentration dependence of the percentage of suppression was observed. Up to 70% of the signal was suppressed upon post-cartridge infusion of 0.22 microg/mL (at 5 microL/min) clenbuterol into the eluate, and this decreased to about 4% at infusion of 22 microg/mL clenbuterol. Molecularly imprinted polymers were used to enhance the selectivity of the extraction. Although matrix components were still present after extraction, no interference of these compounds with the analyte was observed. However, the bleeding of the imprint from the polymer (brombuterol) caused significant ion suppression.


Assuntos
Clembuterol/urina , Espectrometria de Massas/métodos , Animais , Pressão Atmosférica , Bovinos , Feminino , Humanos , Íons , Masculino
3.
Analyst ; 127(3): 355-9, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11996359

RESUMO

To determine sub-ppb levels of drugs in biological samples, selective, sensitive and rapid analytical techniques are required. This work shows the possibilities for high-throughput analysis of solid-phase microextraction (SPME) directly coupled to an ion-trap mass spectrometer equipped with an atmospheric pressure chemical ionisation source. As no chromatographic separation is performed, the SPME procedure is the time-limiting step. Direct immersion SPME under non-equilibrium conditions permits the determination of lidocaine in urine within 10 min. After a 5 min sorption time with a 100 microm polydimethylsiloxane-coated fibre, the extraction yield of lidocaine from urine is about 7%. When applying 4 min desorption, using a mixture of ammonium acetate buffer (pH 4.5) and acetonitrile (85 + 15 v/v), about 10% of the analyte is retained on the fibre. An extra cleaning step of the fibre is therefore used to prevent carry-over. By use of tandem MS, no matrix interference is observed. The detection limit for lidocaine is about 0.4 ng ml(-1) and the intraday and interday reproducibility are within 14% over a concentration range of 2-45 ng ml(1).


Assuntos
Lidocaína/urina , Humanos , Espectrometria de Massa de Íon Secundário/métodos , Fatores de Tempo
4.
Artigo em Inglês | MEDLINE | ID: mdl-11824396

RESUMO

Solid-phase extraction-pipette tips (SPE-PTs) were used for micro solid-phase extraction of lidocaine and diazepam from plasma. Off-line extraction was followed by on-line desorption. On-line desorption was carried out by direct coupling of the SPE-PTs with the liner of the programmed-temperature vaporiser. This coupling only required shortening of the liner by maximally 16 mm, cutting the SPE-PT, and equipping the remaining part with two O-rings. Due to the heating of the injector the SPE-PTs were heated as well, which resulted in a significant amount of impurities. Pre-heating and pre-washing was performed prior to the extraction to reduce the impurity level. The internal coupling device was applied successfully for the analysis of plasma samples with gas chromatography (GC) and mass-selective detection. Detection limits of 0.75 ng/ml and 2.5 ng/ml were obtained for lidocaine and diazepam, respectively, using 200 microl plasma. Recoveries for both compounds were about 80%. Although it is possible, the internal coupling device was not developed to be used as such. The main goal of this coupling was to show the feasibility of the integration of SPE-PTs with GC and to realize an important step to new automated SPE-GC systems.


Assuntos
Diazepam/sangue , Lidocaína/sangue , Cromatografia Gasosa , Estudos de Viabilidade , Espectrometria de Massas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...