Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Ned Tijdschr Geneeskd ; 147(31): 1508-12, 2003 Aug 02.
Artigo em Holandês | MEDLINE | ID: mdl-12924082

RESUMO

OBJECTIVE: Itemize blood transfusion incidents in the South-West Netherlands region (about 3.5 million inhabitants), where a regional reporting system for transfusion incidents was introduced in January 2001. DESIGN: Prospective, descriptive. METHOD: In the period 1 January 2001-31 December 2001, 22 hospitals voluntarily reported transfusion incidents in patients to the blood bank. All incidents were anonymously recorded in a standardised report and registered in 14 categories. RESULTS: A total of 119 transfusion incidents were reported and categorised as: incorrect blood component transfused (n = 8), mild fever 1-2 degrees C (n = 14), non-haemolytic fever > 2 degrees C (n = 36), acute haemolytic transfusion reactions (n = 3). delayed haemolytic transfusion reactions (n = 18), allergic reactions (n = 11), bacterial contamination (n = 3), transfusion-related acute lung injury (n = 1), near accidents (n = 6) and product recalls (n = 19). There were no reports in the categories anaphylactic shock, post-transfusion purpura, transfusion-acquired viral infection, and transfusion-related graft versus host disease. In the same year of haemovigilance, the blood bank issued a total of 158,000 blood products. A complication rate of 1:700 blood products was calculated. It is estimated that 53% of all incidents were reported. CONCLUSION: Despite all of the safety measures taken, severe adverse events still occurred. A well-run system for haemovigilance can contribute to the knowledge of transfusion incidents. The safety and quality of blood transfusions can be improved if this knowledge is incorporated into ongoing education about blood transfusions and in the prevention and treatment of transfusion reactions.


Assuntos
Bancos de Sangue/normas , Transfusão de Sangue/estatística & dados numéricos , Erros Médicos/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Reação Transfusional , Humanos , Países Baixos , Estudos Prospectivos , Gestão de Riscos , Segurança
3.
Thromb Haemost ; 84(2): 156-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10959684

RESUMO

STUDY OBJECTIVE: To assess the accuracy of a rapid ELISA D-dimer assay for the exclusion of pulmonary embolism (PE) in patients suspected of PE, using pulmonary angiography alone as reference method rather than a diagnostic strategy including lung scintigraphy and leg vein ultrasonography. METHODS: In 342 patients who were examined by pulmonary angiography to diagnose or exclude PE, the accuracy of the quantitative rapid VIDAS D-dimer test for the exclusion of PE was evaluated retrospectively. D-dimer levels were assayed in frozen samples collected during the diagnostic work-up at the time of pulmonary angiography while on treatment with unfractionated heparin for 1-2 days. RESULTS: Mean plasma D-dimer concentrations were increased in patients with angiographic evidence of PE (P <0.0001). The sensitivity of D-dimer for segmental PE was 98%, its accuracy in excluding segmental PE was 99%, higher than the respective figures for subsegmental PE (76% and 94%; P <0.01, both). For both forms of PE combined the sensitivity was 90% and the negative predictive value 94%. DISCUSSION: The sensitivity and negative predictive values reported here, are low compared with previous studies using the same rapid ELISA D-dimer assay. This probably reflects an overlooking of mild cases of subsegmental PE in previous studies, although a reduction of D-dimer levels by the heparin pretreatment may have contributed to part of the discrepancy. Prospective studies are needed to clarify this issue.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Embolia Pulmonar/diagnóstico , Adulto , Idoso , Angiografia , Antifibrinolíticos/metabolismo , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Anticancer Res ; 19(4A): 2727-33, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10470230

RESUMO

The technical performance and clinical usefulness of the newly developed Elecsys CA 125 II assay (Boehringer Mannheim) was evaluated in a multicenter study. Imprecision studies were carried out using control sera and human pool sera with CA 125 concentrations from 11 to 1026 U/ml. Within-run CVs between 0.7 to 4.8% (median 1.7%) and between-day CVs between 2.4 to 10.9% (median 5.7%) were found. Method comparison studies with Enzymun-Test CA 125 II carried out in four laboratories yielded slopes between 0.94 to 1.07 and intercepts < 3 U/ml. A good comparability of the Elecsys CA 125 II assay was also found with one MEIA and the Centocor" IRMA. For a second MEIA and a second IRMA the slopes were 1.23 and 1.42, and the corresponding correlation coefficients were 0.987 and 0.977, respectively. The Elecys CA 125 II concentrations are clearly related to the tumor stage of ovarian carcinoma patients. The maximum of diagnostic efficiency of ovarian carcinoma patients compared with patients of benign gynecological diseases is reached at 150 U/ml with a specificity of 93% and a sensitivity of 69%. Follow-up studies of ovarian carcinoma patients reflect the status of the disease and the effect of various therapeutic applications. The technical and clinical evaluation of the Elecsys CA 125 II assay show a superior analytical performance with a broad measuring range up to 5000 U/ml and a short measuring time of 18 minutes.


Assuntos
Antígeno Ca-125/sangue , Eletroquímica/instrumentação , Doenças dos Genitais Femininos/diagnóstico , Neoplasias Ovarianas/diagnóstico , Biomarcadores Tumorais/sangue , Eletroquímica/métodos , Feminino , Doenças dos Genitais Femininos/sangue , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Ensaio Imunorradiométrico/instrumentação , Ensaio Imunorradiométrico/métodos , Medições Luminescentes , Neoplasias Ovarianas/sangue , Valores de Referência , Análise de Regressão , Reprodutibilidade dos Testes
5.
Clin Chem ; 44(12): 2530-6, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9836722

RESUMO

The CA 125 II assay on the Elecsys(R) 2010 analyzer was evaluated in an international multicenter trial. Imprecision studies yielded within-run CVs of 0.8-3.3% and between-day CVs of 2.4-10.9%; CVs for total imprecision in the manufacturer's laboratory were 2.4-7.8%. The linear range of the assay extended to at least 4500 kilounits/L (three decades). Interference from triglycerides (10.3 mmol/L), bilirubin (850 micromol/L), hemoglobin (1.1 mmol/L), anticoagulants (plasma), and several widely used drugs was undetectable. Method comparisons with five other CA 125 II assays showed good correlation but differences in standardization. A 95th percentile cutoff value of 35 kilounits/L was calculated from values measured in 593 apparently healthy (pre- and postmenopausal) women. In 95% of patients with benign gynecological diseases CA 125 was 190 kilounits/L. A comparison of CA 125 values obtained with the Elecsys test and with other common CA 125 tests in monitored patients being treated for ovarian cancer showed identical patterns. In conclusion, the Elecsys CA 125 II assay is linear over a broad range, yields precise and accurate results, is free from interferences, and compares well with other assays.


Assuntos
Antígeno Ca-125/sangue , Adulto , Autoanálise , Feminino , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Cooperação Internacional , Medições Luminescentes , Masculino , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/diagnóstico , Pós-Menopausa/sangue , Pré-Menopausa/sangue , Valores de Referência , Sensibilidade e Especificidade
6.
Clin Biochem ; 30(3): 203-8, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9167895

RESUMO

OBJECTIVE: Establishing the analytical variation and reproducibility of the intracellular magnesium (Mg) assay in mononuclear blood cells (MBC) and erythrocytes (RBC). DESIGN AND METHODS: We assessed the analytical variation of the several determination steps, and the reproducibility for the complete intracellular Mg-assay (combination of preanalytical, analytical, and biological variation). The influence of platelets was determined by comparing Mg concentrations obtained from heparinized blood and defibrinated blood. RESULTS: Coefficients of variation of the several determination steps used in the MBC- and RBC-assay were < or = 5.4%. The overall analytical variation was 5.0-6.8%, and reproducibility of the complete Mg-assay 11.6-14.0%. Mg measurements in MBC (expressed as fmol/cell) obtained from heparinized blood showed significantly higher values than those obtained from defibrinated blood. CONCLUSION: This is the first study to describe in detail reproducibility data for the individual steps in the overall procedure to measure intracellular magnesium. It is shown that results obtained in daily practice should be interpreted with care. Moreover, the removal of platelets is essential in the determination of Mg in MBC.


Assuntos
Eritrócitos/química , Magnésio/sangue , Monócitos/química , Coleta de Amostras Sanguíneas , Heparina , Humanos , Reprodutibilidade dos Testes
7.
Clin Biochem ; 29(3): 261-6, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8740513

RESUMO

OBJECTIVES: Validation and comparison of a magnesium ion-selective electrode (ISE) with a cation-exchange resin technique, followed by determination of all magnesium fractions in serum of healthy volunteers and continuous ambulatory peritoneal dialysis (CAPD) patients. DESIGN AND METHODS: The analytical aspect has been studied by measuring the influence of complexing agents on the fraction ionized magnesium (friMg2+). A theoretical approximation of friMg2+, based on mass equilibria and complexation constants, was calculated and compared with the measurements. RESULTS: ISE measurements showed good agreement with theory. Reference values of the ionized, protein-bound, and complexed magnesium fractions were (mean +/- SD) 0.65 +/- 0.04, 0.27 +/- 0.04, and 0.08 +/- 0.03, respectively. Fractions obtained in the CAPD group were 0.62 +/- 0.04, 0.22 +/- 0.05, and 0.16 +/- 0.05, respectively, and differed significantly from the values of the reference population. CONCLUSIONS: All known serum magnesium parameters can be established by a combination of ultrafiltration, atomic absorption spectrometry, and ISE measurements. Unknown complexing compounds most probably account for the increased fraction of complexed magnesium in the serum of CAPD patients.


Assuntos
Eletrodos Seletivos de Íons , Falência Renal Crônica/metabolismo , Magnésio/sangue , Diálise Peritoneal Ambulatorial Contínua , Ultrafiltração/métodos , Adulto , Idoso , Carbonatos/química , Cromatografia por Troca Iônica/métodos , Citratos/química , Estudos de Avaliação como Assunto , Feminino , Humanos , Falência Renal Crônica/sangue , Magnésio/metabolismo , Masculino , Pessoa de Meia-Idade , Fosfatos/química , Valores de Referência
8.
Eur J Clin Invest ; 26(1): 82-3, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8682161

RESUMO

The hemostatic properties of the pedicled omentoplasty turned out to be helpful in difficult hemorrhages in extensive surgery. As suggested by others, a high concentration of tissue factor (TF) in the omentum could be responsible for this favourable property. The authors investigated the nature of that property in 11 patients who underwent laparotomy. In omentum and striated muscle (controls) the TF-concentrations in both tissues were estimated by the ELISA method. A significant difference between TF-concentration in omentum and striated muscle could be demonstrated.


Assuntos
Hemostasia/fisiologia , Omento/fisiologia , Tromboplastina/análise , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Músculo Esquelético/química , Músculo Esquelético/fisiologia , Omento/cirurgia
9.
Br J Cancer ; 71(3): 512-7, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7880732

RESUMO

DNA adduct levels were measured with atomic spectroscopy in white blood cells (WBCs) from patients with solid tumours who were treated with six weekly courses of cisplatin. In 21 patients (I) the WBCs were collected after thawing frozen whole-blood samples according to a previously described method. In 32 other patients (II) WBCs were collected immediately after blood sample collection. The two methods for WBC collection were also compared in vitro. The maximal DNA adduct levels in vivo after the first course were in I 2.48 +/- 1.14 and in II 1.28 +/- 0.40 pg of platinum per microgram of DNA (P < 0.0001). The DNA 'repair' in the first course (DNA adduct level at the end of the infusion minus the level 15 h post infusion) was in I 40% +/- 29% and in II 18% +/- 29% (P = 0.009). These differences were consistent in all measured courses. In vitro, the DNA adduct levels in the freshly prepared WBCs were significantly lower at 0, 1 and 4, but not 24 h, after start of the incubation with cisplatin than in the WBCs collected after freezing and thawing the blood sample. The same experiment with carboplatin in vitro also resulted in significantly lower adducts in freshly isolated WBCs. The higher DNA adduct levels and DNA 'repair' in I are caused by remaining unbound cisplatin in the sample tubes, which can form DNA adducts ex vivo. The same results in vivo can be anticipated when carboplatin is used.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Cisplatino/sangue , Cisplatino/uso terapêutico , Adutos de DNA/sangue , Reparo do DNA , Leucócitos/química , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carboplatina/sangue , Carboplatina/uso terapêutico , Cisplatino/administração & dosagem , DNA de Neoplasias/sangue , DNA de Neoplasias/efeitos dos fármacos , Etoposídeo/administração & dosagem , Humanos , Cinética , Leucócitos/metabolismo , Platina/sangue
10.
Br J Cancer ; 69(5): 858-62, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8180014

RESUMO

The profiles of an i.v. bolus and 3 h and 20 h infusion of cisplatin (CDDP) were simulated in vitro by using a culture of the IGROV1 human ovarian cancer cell line. Disappearance of pharmacologically active unbound CDDP was accomplished by adding human albumin to the medium. Total and unbound CDDP and CDDP-DNA adduct levels were quantitated by atomic absorption spectroscopy (AAS), and tumour cell survival was measured by the clonogenic assay. The design of the experiment resulted in non-significant differences in the magnitude of the area under the concentration-time curve (AUC) of unbound CDDP between the three dose-input functions (AUC i.v. bolus, 6.34 +/- 0.36; 3 h infusion, 6.35 +/- 0.59; and 20 h infusion, 6.76 +/- 0.40 micrograms h ml-1). Also, the differences between the area under the CDDP-DNA adduct-time curves (AUA) of the three dose-input functions were not significant. The initial rate of decline of the CDDP-DNA adduct-time curve was significantly higher for the i.v. bolus and 3 h infusion than for the 20 h infusion. There was a log-linear relationship between the AUC of unbound CDDP and cell survival. These relationships were not significantly different between the three dose-input functions. Variation in the rate of input of CDDP leads to differences in the shape of the AUC and AUA without significant effects on cell survival.


Assuntos
Adenocarcinoma/metabolismo , Cisplatino/farmacocinética , Adutos de DNA , DNA de Neoplasias/metabolismo , Neoplasias Ovarianas/metabolismo , Sobrevivência Celular , Cisplatino/administração & dosagem , Cisplatino/metabolismo , DNA/metabolismo , Relação Dose-Resposta a Droga , Feminino , Humanos , Células Tumorais Cultivadas
11.
Clin Chem ; 40(1): 52-5, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8287544

RESUMO

We performed an analytical evaluation of a commercially available instrument for determining ionized magnesium through use of a neutral carrier, liquid-membrane-based ion-selective electrode. Reproducibility (CV 2-4%), linearity (0.30-2.50 mmol/L), lower limit of detection (0.30 mmol/L), and absence of interference from Ca2+ indicate adequate performance for measuring ionized magnesium in plasma or serum samples in the normal to high-concentration range. Sodium in excess of 150 mmol/L caused a negative bias, which can be explained by ionic strength-induced changes in activity coefficients. The use of heparin as an anticoagulant must be restricted to concentrations < 15 units/mL because of the binding of magnesium to heparin. The mean +/- SD concentration of ionized magnesium and its fraction of total magnesium in 76 healthy volunteers were 0.56 +/- 0.05 mmol/L and 0.65 +/- 0.04, respectively.


Assuntos
Química Clínica/instrumentação , Magnésio/sangue , Adolescente , Adulto , Anticoagulantes , Cálcio/sangue , Química Clínica/estatística & dados numéricos , Eletrodos , Feminino , Heparina/sangue , Humanos , Lítio/sangue , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Controle de Qualidade , Valores de Referência , Sensibilidade e Especificidade , Sódio/sangue
12.
Clin Chem ; 38(11): 2310-3, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1385018

RESUMO

An immunoactivation assay for determining pancreatic lipase mass concentration was clinically evaluated and compared with results obtained by measuring total amylase and pancreatic amylase activity. A group of 30 patients with pancreatitis was compared with a control group of 32 patients in which this disease was suspected but excluded. Both lipase mass concentration and pancreatic amylase activity exhibit good sensitivity (0.93 each) and specificity (0.94 and 0.97, respectively) at cutoff concentrations of 200 micrograms/L and 200 U/L, respectively. The median increase in lipase mass concentration (37.1 times the upper limit of the reference interval) in the pancreatitis group was higher than that for either total amylase or pancreatic amylase activity (5.94 and 14.5 times, respectively) but showed a similar time to peak value. We conclude that the lipase assay is the method of choice for diagnosing pancreatitis.


Assuntos
Técnicas Imunoenzimáticas , Lipase/sangue , Pâncreas/enzimologia , Pancreatite/enzimologia , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Amilases/sangue , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatite/diagnóstico , Valores de Referência
13.
J Chromatogr ; 565(1-2): 430-5, 1991 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-1874888

RESUMO

An improved method for the determination of serotonin in platelet-rich plasma (PRP) and platelet-poor plasma (PPP), by reversed-phase high-performance liquid chromatography with electrochemical detection and direct plasma injection, is described. The chromatographic system comprises a strong cation-exchange pre-column and a C18 analytical column. The method is selective, rapid, simple and sensitive, and offers good reproducibility and recovery. Reference values for serotonin concentrations in healthy adults (n = 10) are 31 nM for PPP and 6 nmol per 10(9) platelets for PRP. The conditions used for the preparation of PRP and PPP may influence the serotonin concentration in PRP.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Serotonina/sangue , Adulto , Cromatografia Líquida de Alta Pressão/instrumentação , Eletroquímica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Chromatogr ; 430(2): 233-9, 1988 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-3235499

RESUMO

Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific activity of tetrahydrocortisol and tetrahydrocortisone in urine from patients who had received tritium-labelled cortisol was determined by the indicated methods, followed by fraction collection and liquid scintillation counting. The post-column reaction detection procedure was superior to ultraviolet detection, both in selectivity and analysis time. Intra- and inter-assay variance of the post-column reaction detection procedure were 3.7 and 4.7%, respectively. A good correlation (r = 0.99) was obtained between values determined by this procedure and by a thin-layer chromatographic procedure.


Assuntos
Hidrocortisona/urina , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Fina , Humanos , Espectrofotometria Ultravioleta , Tetra-Hidrocortisol/urina , Tetra-Hidrocortisona/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...