J Vasc Access ; : 11297298231185536, 2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37395292

RESUMO

BACKGROUND: Intravenous (IV) therapy using short peripheral IV catheters (PIVC) is commonplace with neonatal patients. However, this therapy is associated with high complication rates including the leakage of infused fluids from the vasculature into the surrounding tissues; a condition referred to as, peripheral IV infiltration/extravasation (PIVIE). OBJECTIVE: The quality improvement project aimed to identify the prevalence of known risk factors for PIVIE in the neonatal intensive care unit (NICU) and explore the feasibility of using novel optical sensor technology to aid in earlier detection of PIVIE events. METHODS: The plan, do, study, act (PDSA) model of quality improvement (QI) was used to provide a systematic framework to identify PIVIE risks and evaluate the potential utility of continuous PIVC monitoring using the ivWatch model 400® system. The site was provided with eight monitoring systems and consumables. Hospital staff were supported with theoretical education and bedside training about the system operations and best use practices. RESULTS: In total 113 PIVIE's (graded II-IV) were recorded from 3476 PIVCs, representing an incidence of 3.25%. Lower birth weight and gestational age were statistically significant factors for increased risk of PIVIE (p = 0.004); all other known risk factors did not reach statistical significance. Piloting the ivWatch with 21 PIVCs using high-risk vesicant solutions over a total of 523.9 h (21.83 days) detected 11 PIVIEs (graded I-II). System sensitivity reached 100%; 11 out of 11 PIVIEs were detected by the ivWatch before clinician confirmation. CONCLUSIONS: Prevailing risk factors for PIVIE in the unit were comparable to those published. Continuous infusion site monitoring using the ivWatch suggests this technology offers the potential to detect PIVIE events earlier than relying on intermittent observation alone (i.e. the current standard of care). However, large-scale study with neonatal populations is required to ensure the technology is optimally configured to meet their needs.

2.
J Vasc Access ; : 11297298231154629, 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36794683

RESUMO

BACKGROUND: Evidence-based insertion and maintenance strategies for neonatal vascular access devices (VAD) exist to reduce the causes of VAD failure and complications in neonates. Peripheral intravenous catheter failure and complications including, infiltration, extravasation, phlebitis, dislodgement with/without removal, and infection are majorly influenced by catheter securement methods. METHODS: A retrospective, observational study using routinely collected data on intravenous device use in a large neonatal intensive care unit in Qatar. A 6-month historical cohort was compared with a 6-month cohort after the introduction of an octyl-butyl-cyanoacrylate glue (CG). In the historical cohort, the catheter was secured using a semi-permeable transparent membrane dressing while in the CG cohort, CG was applied at the insertion site on initial insertion and after any dressing change. This was the only variable intervention between both groups. RESULTS: A total of 8330 peripheral catheters were inserted. All catheters were inserted and monitored by members of the NeoVAT team. 4457 (53.5%) were secured with just a semi-permeable transparent dressing and 3873 (46.5%) secured a semi-permeable transparent dressing with the addition of CG. The odds ratio for premature failure after securement with CG was 0.59 (0.54-0.65) when compared to the catheters secured with a semi-permeable transparent dressing, which was statistically significant (p < 0.001). The correlation between the occurrence of a complication and the use of CG for device securement was significant (p < 0.001). CONCLUSIONS: The risk of developing device-related phlebitis and premature device removal, increased significantly if CG was not used for adjunct catheter securement. In parallel with the currently published literature, this study's findings support the use of CG for vascular device securement. When device securement and stabilization concerns are most pertinent CG is a safe and effective adjunct to reducing therapy failures in the neonatal patient population.

3.
J Vasc Access ; 24(6): 1284-1292, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35196909

RESUMO

BACKGROUND: In neonatal settings vascular access devices are essential for treatment. However, their use is not without risks. The design and materials of peripheral vascular access devices have been evaluated amongst adult populations, but contemporary studies in neonatal settings are scant. PURPOSE/OUTCOME MEASURES: This research describes the prevalence of peripheral intravenous catheter failure related to three different catheter types with the intent to identify modifiable risks that might be used to evaluate device efficacy, innovate neonatal practice, and support future policy developments. METHOD AND SETTING: This was a retrospective observational analysis of routinely collected anonymized intravenous therapy related data. The study was carried out at the tertiary neonatal intensive care unit (112 beds) of the Women's Wellness and Research Center of Hamad Medical Corporation, Doha, Qatar. PARTICIPANTS: Neonates who were admitted to the unit requiring intravenous treatment wherefore peripheral intravenous cannulation was indicated, were included in this study. RESULTS: The use of different type of catheters resulted in significantly less therapy failures as phlebitis and increased dwell time, compared with the control groups. This remains significant after adjusting for age at insertion, gestational age, birth weight, and catheter type. CONCLUSIONS: The study's findings are in accord with international literature concerning adult and pediatric patients concerning the superiority of PUR over PTFE catheters with respect to the risk of phlebitis and longer dwell times. However, the risk of failure of therapy did not differ between catheters. This finding is reassuring and supports practitioner judgment when selecting peripheral catheter devices.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Flebite , Dispositivos de Acesso Vascular , Adulto , Criança , Feminino , Humanos , Recém-Nascido , Catéteres , Unidades de Terapia Intensiva Neonatal , Flebite/epidemiologia , Estudos Retrospectivos
4.
J Vasc Access ; 23(2): 295-303, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33530828

RESUMO

INTRODUCTION: Peripheral intravenous cannulation is the preferred method to obtain vascular access, but not always successful on the first attempt. Evidence on the impact of the intravenous catheter itself on the success rate is lacking. Faster visualization of blood flashback into the catheter, as a result of a notched needle, is thought to increase first attempt success rate. The current study aimed to assess if inserting a notched peripheral intravenous catheter will increase first attempt cannulation success up to 90%, when compared to inserting a catheter without a notched needle. DESIGN: In this block-randomized trial, adult patients in the intervention group got a notched peripheral intravenous catheter inserted, patients in the control group received a traditional non-notched catheter. The primary objective was the first attempt success rate of peripheral intravenous cannulation. Intravenous cannulation was performed according to practice guidelines and hospital policy. RESULTS: About 328 patients were included in the intervention group and 330 patients in the control group. First attempt success was 85% and 79% for the intervention and control group respectively. First attempt success was remarkably higher in the intervention group regarding patients with a high risk for failed cannulation (29%), when compared to the control group (10%). CONCLUSION: This study was unable to reach a first attempt success of 90%, although first attempt cannulation success was higher in patients who got a notched needle inserted when compared to those who got a non-notched needle inserted, unless a patients individual risk profile for a difficult intravenous access.


Assuntos
Cateterismo Periférico , Adulto , Cateterismo Periférico/métodos , Catéteres , Hospitalização , Humanos
5.
J Vasc Access ; 21(5): 687-693, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31969049

RESUMO

AIM: In modern healthcare there is increased focus on optimizing efficiency for every treatment or performed procedure, of which reduction of costs is an important part. With this study, authors aimed to calculate the cost of peripheral intravenous cannulation including all components that influence its price. METHODS: This observational cost-utilization study was conducted between May and October 2016. Hospitalized adults were included in this study, who received usual care. Peripheral intravenous cannulation was carried out according to current hospital protocols, based on international standards for peripheral intravenous catheter insertion. Device costs were assumed equal to the number of attempts multiplied by the fixed supply costs and applicable costs for additional attempts, whereas personnel costs for both nurses and physicians were based on their hourly salary. RESULTS: A total of 1512 patients were included in this study, with a mean of 1.37 (±0.77) attempts and a mean time of 3.5 (±2.7) min were needed for a successful catheter insertion. Adjusted mean costs for peripheral intravenous cannulation were estimated to be €11.67 for each patient, but costs increase as the number of attempts for successful cannulation increases. The cost for patients with a successful first attempt was lower, at approximately €9.32 but increased markedly to €65.34 when five attempts were needed. CONCLUSION: Prevention of multiple attempts may lower the costs, and furthermore, additional technologies applied by nurses to individual patients based on predicted difficult intravenous access will make the application of these additional technologies, in turn, more efficient.


Assuntos
Cateterismo Periférico/economia , Custos Hospitalares , Pacientes Internados , Dispositivos de Acesso Vascular/economia , Adulto , Idoso , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Análise Custo-Benefício , Feminino , Médicos Hospitalares/economia , Humanos , Masculino , Pessoa de Meia-Idade , Recursos Humanos de Enfermagem Hospitalar/economia , Salários e Benefícios/economia , Fatores de Tempo
6.
J Vasc Access ; 20(6): 621-629, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30919735

RESUMO

BACKGROUND: Peripheral intravenous cannulation is one of the most frequently performed medical procedures. Venodilation, which can be achieved with different techniques, is an important factor for first attempt success. The objective of this study was to compare the first attempt success rates upon peripheral intravenous cannulation after applying a tourniquet, with venous dilation by electrical stimulation using the Veinplicity® device, or a combination of both techniques, in participants at moderate risk of a difficult peripheral intravenous access. METHODS: This non-randomized clinical trial was carried out in adult patients divided into three parallel study groups, consisting of cannulation with a tourniquet (control group), cannulation after electrical stimulation without using a tourniquet (intervention group 1), and cannulation after applying electrical stimulation followed by the application of a tourniquet on the selected upper extremity (intervention group 2). The primary outcome was the first attempt success rate of peripheral intravenous catheter placement. RESULTS: In all, 141 participants were included in this study, with an overall success rate of 86%. Success rates of 78%, 88%, and 92% were observed in the control group, intervention group 1, and intervention group 2, respectively (p = 0.25, χ2 = 2.771, df = 2). A higher first attempt success rate was detected in participants in intervention group 2, when compared to the control group (p = 0.04, χ2 = 4.63, df = 1). CONCLUSION: Increase in first attempt success was clinically relevant when electrical stimulation with the Veinplicity® device was combined with the application of a tourniquet in participants at moderate risk of a difficult peripheral intravenous access.


Assuntos
Cateterismo Periférico/instrumentação , Estimulação Elétrica/instrumentação , Torniquetes , Extremidade Superior/irrigação sanguínea , Dispositivos de Acesso Vascular , Vasodilatação , Veias , Adulto , Idoso , Cateterismo Periférico/efeitos adversos , Estimulação Elétrica/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados não Aleatórios como Assunto , Fluxo Sanguíneo Regional , Fatores de Risco
7.
J Vasc Access ; 19(3): 258-265, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29772984

RESUMO

BACKGROUND: Approximately 1.2 billion peripheral intravenous catheters are inserted across the world annually. It is known that intravenous cannulation may be a painful procedure, which affects cognitive abilities by increasing anxiety and discomfort. AIM: We hypothesized that inserting a smaller sized peripheral intravenous catheter has a lower level of pain sensation compared to a larger sized catheter. METHODS: This observational, cross-sectional study was conducted between May and October 2016, in which surgical patients, aged 18 years or older, were eligible to participate. Experienced anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access according to the standards of care. The primary outcome was pain (verbal numeric rating scale, 0-10) upon intravenous cannulation. RESULTS: A total of 1063 patients were included and they were divided into four groups: group 1, 22 gauge (N = 29); group 2, 20 gauge (N = 447); group 3, 18 gauge (N = 531); and group 4, sized over 18 gauge (N = 56). Inserting an 18-gauged peripheral intravenous catheter resulted in the lowest pain score (3.2 ± 2.0). As a result of the multivariate linear analysis, five factors were significantly associated with pain upon inserting a peripheral intravenous catheter (sex, American Society of Anesthesiology classification, a patients risk profile on the A-DIVA scale, site of cannulation on the extremity, and whether or not the attempt was successful); however, the size of the inserted peripheral intravenous catheter had no significant relation to the primary outcome. CONCLUSION: Inserting a smaller sized peripheral intravenous catheter did not result in a lower pain sensation. Moreover, to prevent pain upon inserting a peripheral intravenous catheter, an unsuccessful attempt must be avoided.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Dor/etiologia , Adulto , Idoso , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/instrumentação , Distribuição de Qui-Quadrado , Estudos Transversais , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Dor/diagnóstico , Medição da Dor , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...