Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573128

RESUMO

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Assuntos
Fibrilação Atrial , Diafragma , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Feminino
3.
Eur Heart J Cardiovasc Imaging ; 25(3): 347-355, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-37812691

RESUMO

AIMS: We examined the association between the symptom-to-reperfusion-time and cardiovascular magnetic resonance (CMR)-derived global strain parameters and transmural infarct extent in ST-segment elevation myocardial infarction (STEMI) patients. METHODS AND RESULTS: The study included 108 STEMI patients who underwent successful primary percutaneous coronary intervention (PPCI). Patients were categorized according to the median symptom-to-reperfusion-time: shorter (<160 min, n = 54) and longer times (>160 min, n = 54). CMR was performed 2-7 days after PPCI and at 1 month. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to evaluate transmural infarct extent. Myocardial feature-tracking was used for strain analysis. Groups were comparable in relation to incidence of LAD disease and pre- and post-PPCI thrombolysis in myocardial infarction (TIMI) flow grades. The mean transmural extent score at follow-up was lower in patients with shorter reperfusion time (P < 0.01). Both baseline and follow-up maximum transmural extent scores were smaller in patients with shorter reperfusion time (P = 0.03 for both). Patients with shorter reperfusion time had more favourable global left ventricular (LV) circumferential strain (baseline, P = 0.049; follow-up, P = 0.01) and radial strain (baseline, P = 0.047; follow-up, P < 0.01), whilst LV longitudinal strain appeared comparable for both baseline and follow-up (P > 0.05 for both). In multi-variable regression analysis including all three strain directions, baseline LV circumferential strain was independently associated with the mean transmural extent score at follow-up (ß=1.89, P < 0.001). CONCLUSION: In STEMI patients, time-to-reperfusion was significantly associated with smaller transmural extent of infarction and better LV circumferential and radial strain. Moreover, infarct transmurality and residual LV circumferential strain are closely linked.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Meios de Contraste , Gadolínio , Coração , Reperfusão
4.
JACC Clin Electrophysiol ; 9(12): 2665-2679, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737780

RESUMO

Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.


Assuntos
Ablação por Cateter , Meios de Contraste , Humanos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
5.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37489727

RESUMO

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Isquemia Miocárdica , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Cardiomiopatia Dilatada/etiologia , Isquemia Miocárdica/etiologia , Imageamento por Ressonância Magnética
6.
Eur Heart J Cardiovasc Imaging ; 23(6): 836-845, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34195800

RESUMO

AIMS: This study aims to explore cardiovascular magnetic resonance (CMR)-derived left ventricular (LV) function, strain, and infarct size characteristics in patients with transient ST-segment elevation myocardial infarction (TSTEMI) compared to patients with ST-segment and non-ST-segment elevation myocardial infarctions (STEMI and NSTEMI, respectively). METHODS AND RESULTS: In total, 407 patients were enrolled in this multicentre observational prospective cohort study. All patients underwent CMR examination 2-8 days after the index event. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to determine infarct size and identify microvascular obstruction (MVO). TSTEMI patients demonstrated the highest LV ejection fraction and the most preserved global LV strain (longitudinal, circumferential, and radial) across the three groups (overall P ≤ 0.001). The CMR-defined infarction was less frequently observed in TSTEMI than in STEMI patients [77 (65%) vs. 124 (98%), P < 0.001] but was comparable with NSTEMI patients [77 (65%) vs. 66 (70%), P = 0.44]. A remarkably smaller infarct size was seen in TSTEMI compared to STEMI patients [1.4 g (0.0-3.9) vs. 13.5 g (5.3-26.8), P < 0.001], whereas infarct size was not significantly different from that in NSTEMI patients [1.4 g (0.0-3.9) vs. 2.1 g (0.0-8.6), P = 0.06]. Whilst the presence of MVO was less frequent in TSTEMI compared to STEMI patients [5 (4%) vs. 53 (31%), P < 0.001], no significant difference was seen compared to NSTEMI patients [5 (4%) vs. 5 (5%), P = 0.72]. CONCLUSION: TSTEMI yielded favourable cardiac LV function, strain, and infarct-related scar mass compared to STEMI and NSTEMI. LV function and infarct characteristics of TSTEMI tend to be more similar to NSTEMI than STEMI.


Assuntos
Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Meios de Contraste , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Estudos Prospectivos , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...