Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electroencephalogr Clin Neurophysiol ; 102(4): 340-2, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9146496

RESUMO

Interictal spikes on intraoperative electrocorticography during epilepsy are used to tailor resections. There have been a few systematic quantitative studies of anesthetic effects on these interictal discharges, and none on the effects of nitrous oxide (N2O). We calculated spike rates on ECoG on and off N2O in 18 epilepsy surgery patients with subdural strips and grids, analyzing the most active recording contract. In a blinded analyses ten patients had fewer spikes on N2O, while eight patients had more spikes on N2O. The mean spike rates did not differ (41/min on N2O and 40/min off N2O). Spike rate on and off N2O were compared using the non-parametric Wilcoxon matched pairs test. These rates were not significantly different. Our study indicates that N2O in doses employed dose not effect interictal spikes and this agent may be used during epilepsy surgery without concerns about suppression of epileptiform activity.


Assuntos
Eletroencefalografia/efeitos dos fármacos , Epilepsia/fisiopatologia , Epilepsia/cirurgia , Óxido Nitroso/farmacologia , Humanos
2.
J Clin Monit ; 11(5): 342-7, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7595692

Assuntos
Música , Seringas
5.
Neurosurgery ; 12(5): 503-6, 1983 May.
Artigo em Inglês | MEDLINE | ID: mdl-6346132

RESUMO

Pulmonary air embolism is recognized as a possible complication of neurosurgical procedures performed with the patient in the sitting position. A variety of preventive and therapeutic modalities have been proposed in the literature. We have used a consistent regimen consisting of precordial Doppler monitoring, measurement of end expiratory CO2, the semireclining position, and positive end expiratory pressure (PEEP). A right atrial catheter was not used. This approach has given good results in 81 patients; there was significant air embolism in only 1 case (1.2%). We believe that PEEP is as important in the prevention as it is in the treatment of pulmonary air embolism. By flexibly adjusting the level of PEEP, one may recreate the hemodynamic equivalent of the prone position, thereby eliminating the risk of venous air embolism and simultaneously the need for right heart catheterization.


Assuntos
Embolia Aérea/prevenção & controle , Respiração com Pressão Positiva , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Embolia Aérea/etiologia , Humanos , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos , Complicações Pós-Operatórias , Postura , Ultrassonografia
8.
J Neurol Neurosurg Psychiatry ; 42(6): 557-62, 1979 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-469563

RESUMO

We have studied two cases of the syndrome of myokymia and impaired muscular relaxation with continuous motor unit activity. Both patients complained of muscle twitching, weakness, stiffness, and hyperhydrosis during their illness. Myokymia was present over the entire body in both. On repetitive testing of muscle strength each patient showed initial fatigue followed by increasing strength as he continued his efforts. Both patinets improved on phenytoin therapy at high blood levels. Nerve conduction velocities were decreased. Electromyograms showed continuous electrical activity at rest which persisted during sleep and spinal anaesthesia but was diminished by curare. Intravital staining with methylene blue in one case demonstrated sprouting and beading of motor nerve terminals with multiple innervation of muscle fibres. The neurophysiological and pathological findings in these two cases indicate an abnormality of peripheral nerve in this disorder.


Assuntos
Doenças Neuromusculares/diagnóstico , Adulto , Eletromiografia , Humanos , Masculino , Pessoa de Meia-Idade , Neurônios Motores , Relaxamento Muscular , Músculos/patologia , Mioclonia/diagnóstico , Doenças Neuromusculares/tratamento farmacológico , Doenças Neuromusculares/patologia , Nervos Periféricos/patologia , Fenitoína/uso terapêutico , Síndrome
10.
Arch Gynecol ; 226(1-2): 39-43, 1978 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33620

RESUMO

A study of the accuracy of the tpH electrode was performed in 10 cats. Hypoxia and acidosis were produced by ventilatory means and bicarbonate infusions were used to elevate the pH . Tissue pH correlated well with arterial (r = 0.9) within the physiological rates of change of pH. Prolonged tissue acidosis lead to eventual death. The correct and stable mechanical fixation of the pH electrode is a critical factor in assuring accurate results. The ROCHE tpH electrode accurately reflects arterial pH, and a correlation coefficient of at least 0.85 should be attainable in the human fetus.


Assuntos
Eletrodos , Concentração de Íons de Hidrogênio , Animais , Artérias , Gatos , Estudos de Avaliação como Assunto , Hidrogênio/sangue , Veias
11.
Am J Obstet Gynecol ; 131(7): 770-4, 1978 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28671

RESUMO

An improved continuous tissue pH monitoring system, designed for human subcutaneous fetal scalp tissue, was evaluated in 10 cats for total of 60 hours. Respiratory acidosis was induced with and without hypoxia to model the pathology of human clinical fetal distress. Arterial and venous pH were sampled every 15 minutes and the values were compared to those from the pH monitor system. The values paralleled arterial and venous blood pH, with correlation coefficients up to 0.98 under various pathologic acidotic conditions.


Assuntos
Monitorização Fisiológica , Animais , Artérias , Gatos , Estudos de Avaliação como Assunto , Concentração de Íons de Hidrogênio , Monitorização Fisiológica/instrumentação , Veias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...