Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Pediatr ; 12: 1395395, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756973

RESUMO

Objective: This study aims to assess the comparative effectiveness of a conventional splitting needle or a peelable cannula vs. the modified Seldinger technique (MST) by utilizing a dedicated micro-insertion kit across various clinically significant metrics, including insertion success, complications, and catheter-related infections. Methods: We conducted a retrospective observational cohort study using an anonymized data set spanning 3 years (2017-2019) in a large tertiary-level neonatal intensive care unit in Qatar. Results: A total of 1,445 peripherally inserted central catheter (PICC) insertion procedures were included in the analysis, of which 1,285 (89%) were successful. The primary indication for insertion was mainly determined by the planned therapy duration, with the saphenous vein being the most frequently selected blood vessel. The patients exposed to MST were generally younger (7 ± 15 days vs. 11 ± 26 days), but exhibited similar mean weights and gestational ages. Although not statistically significant, the MST demonstrated slightly higher overall and first-attempt insertion success rates compared to conventional methods (91 vs. 88%). However, patients undergoing conventional insertion techniques experienced a greater incidence of catheter-related complications (p < 0.001). There were 39 cases of catheter-related bloodstream infections (CLABSI) in the conventional group (3.45/1,000 catheter days) and eight cases in the MST group (1.06/1,000 catheter days), indicating a statistically significant difference (p < 0.001). Throughout the study period, there was a noticeable shift toward the utilization of the MST kit for PICC insertions. Conclusion: The study underscores the viability of MST facilitated by an all-in-one micro kit for neonatal PICC insertion. Utilized by adept and trained inserters, this approach is associated with improved first-attempt success rates, decreased catheter-related complications, and fewer incidences of CLABSI. However, while these findings are promising, it is imperative to recognize potential confounding factors. Therefore, additional prospective multicenter studies are recommended to substantiate these results and ascertain the comprehensive benefits of employing the all-in-one kit.

2.
Front Pediatr ; 11: 1237648, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691778

RESUMO

Neonatal vascular access continues to pose challenges. Recent times have seen considerable innovations in practice and the design and manufacture of materials used to provide infusion-based therapies with the intent of reducing the incidence and severity of vascular access-related complications. However, despite these efforts, vascular access-related complication rates remain high in this patient group and research evidence remains incomplete. In neonates, a medical-grade formulation of cyanoacrylate adhesive is widely used to secure percutaneously inserted central venous catheters and is beginning to establish a role in supporting the effective securement of other devices, such as umbilical and peripheral intravenous catheters. This Perspective article considers issues specific to the removal of cyanoacrylate used to secure vascular access devices from neonatal skin before its bonding releases due to natural skin exfoliation processes. The aim of this information is to ensure the safe and effective removal of octyl-cyanoacrylate adhesive-secured vascular access catheters from neonatal skin and stimulate professional discussion.

3.
4.
Nurs Crit Care ; 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37338149

RESUMO

BACKGROUND: Blood draws for laboratory investigations are essential for patient management in neonatal intensive care units (NICU). When blood samples clot before analysis, they are rejected, which delays treatment decisions and necessitates repeated sampling. AIMS: To decrease the incidence of rejected blood samples taken for laboratory investigation as a result of clotted sample. STUDY DESIGN: This retrospective observational study used routine data on blood draws from preterm infants collected between January 2017 and June 2019 in a 112-cot NICU in Qatar. Quality improvement interventions to reduce the rate of clotted blood samples included: awareness raising and safe sampling workshops with NICU staff, involvement of the neonatal vascular access team, development of a complete blood count (CBC) sample collection pathway, review of sample collection equipment, introducing the Tenderfoot® heel lance, establishment of benchmarks and provision of dedicated blood extraction equipment. RESULTS: First attempt blood draw occurred in 10 706 cases, representing a 96.2% success rate. In 427 (3.8%) cases, the samples were clotted requiring repeat collection. The overall rate of clotted specimens decreased from 4.8% in 2017 and 2018 to 2.4% in 2019, with odds ratios of 1.42 (95% confidence interval [CI] 1.13-1.78, p = .002), 1.46 (95% CI 1.17-1.81, p < .001) and 0.49 (95% CI 0.39-0.63, p < .001), respectively. The majority (87%-95%) of blood samples were by venepuncture using an intravenous (IV) catheter or the NeoSafe™ blood sampling device. Heel prick sampling was the second (2%-9%) most common method. Clotted samples were most frequently associated with needle use, 228 of 427 (53%), and IV cannula, 162 of 427 (38%), with odds ratios of 4.14 (95% CI 3.34-5.13, p < .001) and 3.11 (95% CI 2.51-3.86, p < .001), respectively. CONCLUSIONS: Our interventions over 3 years were associated with reduced rates of sample rejection due to clotting, and this led to improved patient experience through fewer repeated samplings. RELEVANCE TO CLINICAL PRACTICE: The insights gained from this project can help to improve patient care. Interventions that reduce the rate of blood sample rejection by clinical laboratories can lead to economic savings, timelier diagnostic and treatment decisions, and contribute to an improved quality care experience for all critical care patients, irrespective of age, by reducing the need for repeated phlebotomy and the risk of related complications.

5.
J Vasc Access ; 24(6): 1390-1397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35435032

RESUMO

BACKGROUND: Infants in neonatal units are susceptible to numerous potential iatrogenic risks. One key concern is central line-associated blood stream infection (CLABSI). To ensure patient safety and reduce the incidence of CLABSI toward zero, numerous evidence-based clinical interventions and product innovations have been implemented. Nevertheless, sustaining zero CLABSI for sustained periods remains challenging. AIM: The purpose of this study was to evaluate the impact on CLABSI rates of introducing a preassembled closed intravenous (IV) administration set in a neonatal intensive care unit (NICU). METHODS: This was a retrospective observational analysis of routinely collected anonymized IV therapy infection data in a NICU. The study period was from January 2019 through June 2020. RESULTS: Nine-hundred eighty five patients with a Epicutaneo-Caval Catheter (ECC) were included (456 legacy IV set, 529 closed IV set). Patient demographics were comparable between the two groups. ECC dwell time was the only IV characteristic associated (p = 0.04) with CLABSI. Mann-Whitney U-test demonstrated significant differences between the two sets for CLABSI complication events (p = 0.031). Prior to using the closed IV administration sets (January 2019-September 2019) the mean monthly CLABSI rate was 2.87 (/1000 device days). This figure declined to 0.22 (/1000 device days) afterwards (October 2019-June 2020). Zero CLABSIs were observed during January to June 2020. CONCLUSIONS: Utilization of a pre-assembled closed IV administration set was associated with a reduction in CLABSI rates. The study results suggest that using a pre-assembled closed IV set concurrently with evidence-based central line infection control interventions can help attain extended periods of zero CLABSI.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Recém-Nascido , Lactente , Humanos , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/prevenção & controle , Infecções Relacionadas a Cateter/epidemiologia , Controle de Infecções , Unidades de Terapia Intensiva Neonatal
6.
Front Pediatr ; 10: 1012800, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36507144

RESUMO

Background: The use of antimicrobial-impregnated peripherally inserted central catheters (PICCs) has been introduced in the last few years to neonatal units aiming to reduce central line-associated bloodstream infection (CLABSI). Methods: This retrospective observational study aimed to compare the CLABSI rates and other catheter-related parameters including the insertion success rates and catheter-related complications in the antimicrobial-impregnated and conventional (ordinary) PICCs in NICU between 2017 and 2020. Results: Our dedicated PICC team including physicians and nurses inserted 1,242 conventional (PremiCath and NutriLine) and 791 antimicrobial-impregnated PICCs (PremiStar) over the study period from 2017 to 2020. Of those 1,242 conventional PICCs, 1,171 (94.3%) were 1 Fr single lumen and only 71 (5.7%) were 2 Fr double lumen. The mean ± SD [median (IQR)] for the birth weight in all babies who had a PICC line was 1,343.3 ± 686.75 [1,200 (900, 1,500)] g, while the mean ± SD for the gestational age was 29.6 ± 4.03 [29 (27, 31)] weeks. The mean ± SD [median (IQR)] age at the time of insertion for all catheters was 9.3 ± 21.47 [2 (1, 9)] days, while the mean ± SD [median (IQR)] dwell time was 15.7 ± 14.03 [12 (8, 17)] days. The overall success rate of the PICC insertion is 1,815/2,033 (89.3%), while the first attempt success rate is 1,290/2,033 (63.5%). The mean ± SD [median (IQR)] gestational age, birth weight, age at catheter insertion, and catheter dwell time were 28.8 ± 3.24 [29, (26, 31)] weeks, 1,192.1 ± 410.3 [1,150, (900, 1,450)] g, 6.3 ± 10.85 [2, (1, 8)] days, and 17.73 ± 17.532 [13, (9, 18)] days in the antimicrobial-impregnated catheter compared with 30.1 ± 4.39 [29, (27, 32)] weeks (P < 0.001), 1,439.5 ± 800.8 [1,240, (920, 1,520)] g (P < 0.001), 11.1 ± 25.9 [1, (1, 9)] days (P < 0.001), and 14.30 ± 10.964 [12, (8, 17)] days (P < 0.001), respectively, in the conventional PICCs. The use of the antimicrobial-impregnated catheter was not associated with any significant reduction in the CLABSI rate (per 1,000 days dwell time), either the overall [P = 0.11, risk ratio (RR) (95% CI): 0.60 (0.32, 1.13)] or the yearly CLABSI rates. Conclusions: The use of miconazole and rifampicin-impregnated PICCs did not reduce the CLABSI rate in neonates compared with conventional PICCs. However, it has a higher overall rate of elective removal after completion of therapy and less extravasation/infiltration, occlusion, and phlebitis compared with the conventional PICCs. Further large RCTs are recommended to enrich the current paucity of evidence and to reduce the risk of bias. Neonatal PICCs impregnation by other antimicrobials is a recommendation for vascular access device manufacturers.

7.
Front Pediatr ; 10: 980725, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405839

RESUMO

Background: Venous access devices (VADs) play a vital role within the neonatal intensive care unit. However, there are significant risks associated with the use of VADs, with complications such as infection, thrombosis, device occlusion, and infiltration/extravasation frequently contributing to device-related failures and increasing the risk of significant patient harm or injury. This study aimed to explore the relationships between risk factors and different venous access device complications in the neonatal setting, and then use that evidence to develop an algorithm based on observational data. Methods: This is a retrospective, single-center cohort study that was conducted in a large 112-bed neonatal intensive care unit in Qatar. We examined venous access device data from January 2016 to December 2018 for all term and preterm neonates. Descriptive statistics were used to summarize the outcomes, which included a mean and its standard deviation or median and an interquartile range for continuous variables regarding normal distribution, and absolute numbers with percentages for discrete variables. Results: The authors recorded a total of 23,858 VADs inserted during the study period. Of these, 21,313 (89%) were peripheral intravenous catheters, 689 (3%) were extended dwell-peripheral intravenous catheters, 1,335 (6%) were epicutaneo-caval catheters, and 521 (2%) were umbilical venous catheters. In total, 51,179 catheter days were registered, with 2.17 catheter days reported per patient. Peripheral device dwell times were significantly shorter when compared with central venous catheter devices (P < 0.001), with mean dwell times of 22 days ± 23 h and 236 days ± 183 h, respectively. After insertion, a complication occurred in 11,177 (51%) of peripheral VADs and 221 (12%) of central VADs. The type of device inserted [P < 0.001, hazard ratio (HR) = 0.52, 95% confidence interval (CI): 0.50-0.54], reason/indication for intravenous therapy (P < 0.001, HR = 0.85, 95% CI: 0.82-0.87), and the side of insertion of the device (P < 0.001, HR = 1.25, 95% CI: 1.24-1.27) had a significant relationship with outcomes. Conclusions: Four subgroups of VADs were identified (peripheral intravenous catheters, extended dwell-peripheral intravenous devices, epicutaneo-caval catheters, and umbilical venous catheters) with outcome-related differences. Central venous access devices (epicutaneo-caval catheters and umbilical venous catheters) had lower complications compared with peripheral VADs. Proper venous access device selection, early insertion, and early removal approaches remain crucial to preventing venous access device complications. Peripheral intravenous devices should be used carefully and closely watched for early detection of complications.

8.
BMC Pediatr ; 22(1): 71, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35094692

RESUMO

BACKGROUND: Medical management of neonates is often established upon safe and reliable vascular access, frequently utilized to provide physiological monitoring, parenteral and supportive treatments, and diagnostic and/or procedural purposes. For this, peripherally inserted central catheters (PICCs) are often used to provide safe vascular access and infusion-related therapies in the neonatal intensive care (NICU) setting. PURPOSE: Difficult PICC guidewire removal is understood to cause catheter damage, causing luminal rupture or possible breakage of the catheter or guidewire itself. The aim of this study was to assess and compare the incidence of therapy failures with use of a preflush fluid using normal saline (NSS) versus a diluted lipid solution (DLS) prior to device insertion, to assist with guidewire removal and prevent unnecessary catheter damage. METHOD AND SETTING: A retrospective, observational study was performed in the Neonatal Intensive Care Unit (NICU) of the Women's Wellness and Research Centre, Hamad Medical Corporation, Qatar. This single site study included 507 neonates who required intravenous therapy administered via a PICC during the study period. RESULTS: Results demonstrated the use of a diluted lipid solution preflush (DLS) resulted in significantly lesser failures, when compared with the control group (NSS). This highlights a clinical significance after adjusting for day of insertion, gestational age, birth weight and catheter type. CONCLUSION: DLS preflush demonstrated a benefit over the use of a NSS preflush to enhance PICC guidewire removal in neonatal patients in the NICU. The risk for development of maintenance-related complications leading to premature device removal decreased significantly if the DLS preflush was used. During the study period, no complications related to the use of a lipid preflush solution were identified. IMPLICATIONS FOR PRACTICE AND RESEARCH: This may be the first study published investigating and supporting guidewire removal enhancement by using a diluted lipid/saline preflush solution. When the requirement for vascular access is most pertinent in the neonate, using a diluted lipid preflush may provide an effective method to assist in guidewire removal to prevent malposition and vascular device complications in the neonatal population.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Catéteres , Emulsões , Feminino , Humanos , Recém-Nascido , Lipídeos , Lubrificantes , Estudos Retrospectivos , Fatores de Risco
9.
BMJ Open ; 11(9): e047788, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34497079

RESUMO

OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN: This was a retrospective observational study. SETTING: The study was performed on the neonatal intensive care unit of the Women's Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS: This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS: The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS: A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION: Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate.


Assuntos
Cateterismo Periférico , Remoção de Dispositivo , Administração Intravenosa , Cateterismo Periférico/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...