1.
J Med Case Rep ; 16(1): 356, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36195885

RESUMO

BACKGROUND: Pancreatic panniculitis is characterized by subcutaneous fat necrosis and is a rare presentation of an underlying pancreatic disease, appearing in approximately 2-3% of all patients with a pancreatic disease. The nodules usually involve the lower extremities. Pancreatic panniculitis is commonly associated with acute or chronic pancreatitis, and occasionally with pancreatic cancer, especially acinar cell carcinoma. CASE PRESENTATION: A 77-year-old Caucasian woman with no significant medical history was referred to our center with multiple painful, itchy, and warm red/blue cutaneous nodules on the left lower leg. These skin lesions were consistent with the clinical diagnosis of panniculitis. The skin biopsy obtained showed a predominantly lobular panniculitis with fat necrosis of which the aspect was highly suspicious for pancreatic panniculitis. Further analysis revealed high lipase serum of > 3000 U/L (normal range < 60 U/L), and on computed tomography scan a mass located between the stomach and the left pancreas was seen. Endoscopic ultrasonography-guided fine-needle biopsy confirmed the diagnosis of acinar cell carcinoma. After discussing the patient in the pancreatobiliary multidisciplinary team meeting, laparoscopic distal pancreatectomy including splenectomy and en bloc wedge resection of the stomach due to tumor in-growth was performed. The cutaneous nodules on both legs disappeared 1-2 days after surgery. No long-term complications were reported during follow-up. One year after surgery, the patient presented with similar symptoms as preoperatively. Computed tomography scan showed local recurrence and distal metastases, which were subsequently confirmed by biopsy. She started with palliative folinic acid-fluorouracil-irinotecan-oxaliplatin chemotherapy but stopped after two cycles because of disease progression. The patient died 2 months later, 13 months after surgical resection. CONCLUSION: This case illustrates the importance of clinically recognizing cutaneous nodules and pathological recognizing the specific microscopic changes as sign of a (malignant) pancreatic disease.


Assuntos
Carcinoma de Células Acinares , Pancreatopatias , Neoplasias Pancreáticas , Paniculite , Células Acinares/patologia , Idoso , Carcinoma de Células Acinares/complicações , Carcinoma de Células Acinares/diagnóstico , Carcinoma de Células Acinares/cirurgia , Feminino , Fluoruracila , Humanos , Irinotecano , Leucovorina , Lipase , Extremidade Inferior/patologia , Oxaliplatina , Pancreatopatias/patologia , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas
2.
Comput Methods Programs Biomed ; 206: 106105, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33979752

RESUMO

PURPOSE: The aim of the current study is to develop a prediction model for glucose levels applicable for all patients admitted to the ICU with an expected ICU stay of at least 24 h. This model will be incorporated in a closed-loop glucose system to continuously and automatically control glucose values. METHODS: Data from a previous single-center randomized controlled study was used. All patients received a FreeStyle Navigator II subcutaneous CGM system from Abbott during their ICU stay. The total dataset was randomly divided into a training set and a validation set. A glucose prediction model was developed based on historical glucose data. Accuracy of the prediction model was determined using the Mean Squared Difference (MSD), the Mean Absolute Difference (MAD) and a Clarke Error Grid (CEG). RESULTS: The dataset included 94 ICU patients with a total of 134,673 glucose measurements points that were used for modelling. MSD was 0.410 ± 0.495 for the model, the MAD was 5.19 ± 2.63 and in the CEG 99.8% of the data points were in the clinically acceptable regions. CONCLUSION: In this study a glucose prediction model for ICU patients is developed. This study shows that it is possible to accurately predict a patient's glucose 30 min ahead based on historical glucose data. This is the first step in the development of a closed-loop glucose system.


Assuntos
Estado Terminal , Glucose , Glicemia , Automonitorização da Glicemia , Humanos
3.
J Clin Monit Comput ; 32(5): 953-964, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29218549

RESUMO

Subcutaneous continuous glucose monitoring (CGM) may have benefits in achieving glycemic control in critically ill patients. The aim of this study was to assess the accuracy and reliability of the FreeStyle Navigator I in critically ill patients and to assess patient related factors influencing the accuracy and reliability. This study is a retrospective analysis of data from a randomized controlled trial conducted in a 20-bed mixed intensive care unit. Analytical accuracy, clinical accuracy and reliability were assessed against arterial blood glucose samples as reference. Assessment was according to recent consensus recommendations with median absolute relative difference (median ARD), Bland-Altman plots, the ISO system accuracy standards (ISO 15197:2013) and Clarke error grid analysis (CEG). We analyzed 2840 paired measurements from 155 critically ill patients. The median ARD of all paired values was 13.3 [6.9-22.1]%. The median ARD was significantly higher in both the hypoglycemic and the hyperglycemic range (32.4 [12.1-53.4]% and 18.7 [10.7-28.3]% respectively, p < 0.001). The Bland-Altman analysis showed a mean bias of - 0.82 mmol/L with a lower limit of agreement (LOA) of - 3.88 mmol/L and an upper LOA of 2.24 mmol/L. A total of 1626 (57.3%) values met the ISO-2013, standards and 1,334 (47%) CGM values were within 12.5% from the reference value. CEG: 71.0% zone A, 25.8% zone B, 0.5% zone C, 2.5% zone D, 0.3% zone E. The median overall real-time data display time was 94.0 ± 14.9% and in 23% of the patients, the sensor measured < 95% of the time. Additionally, data gaps longer than 30 min were found in 48% of the patients. The analytical accuracy of the FreeStyle Navigator I in critically ill patients was suboptimal. Furthermore, the clinical accuracy, did not meet the required standards. The reliability was satisfactory, however, in almost a quarter of the patients the realtime data display was < 95%. The accuracy was considerably and significantly lower in hyper- and hypoglycemic ranges.


Assuntos
Glicemia/análise , Monitorização Fisiológica/instrumentação , Idoso , Estado Terminal/enfermagem , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/enfermagem , Monitorização Fisiológica/estatística & dados numéricos , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Anaesthesia ; 73(3): 332-339, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29230803

RESUMO

In this open-label multicentre randomised controlled trial, we investigated three peri-operative treatment strategies to lower glucose and reduce the need for rescue insulin in patients aged 18-75 years with type-2 diabetes mellitus undergoing non-cardiac surgery. Patients were randomly allocated using a web-based randomisation program to premedication with liraglutide (liraglutide group), glucose-insulin-potassium infusion (insulin infusion group) or insulin bolus regimen (insulin bolus group), targeting a glucose < 8.0 mmol.l-1 . The primary outcome was the between group difference in median glucose levels 1 h after surgery. We analysed 150 patients (liraglutide group n = 44, insulin infusion group n = 53, insulin bolus group n = 53) according to the intention-to-treat principle. Median (IQR [range]) plasma glucose 1 h postoperatively was lower in the liraglutide group compared with the insulin infusion and insulin bolus groups (6.6 (5.6-7.7 [4.2-13.5]) mmol.l-1 vs. 7.5 (6.4-8.3 [3.9-16.6]) mmol.l-1 (p = 0.026) and 7.6 (6.4-8.9 [4.7-13.2]) mmol.l-1 ) p = 0.006, respectively). The incidence of hypoglycaemia and postoperative complications did not differ between the groups. Six patients had pre-operative nausea in the liraglutide group, of which two had severe nausea, compared with no patients in the insulin infusion and insulin bolus groups (p = 0.007). The pre-operative administration of liraglutide stabilised peri-operative plasma glucose levels and reduced peri-operative insulin requirements, at the expense of increased pre-operative nausea rates.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Liraglutida/uso terapêutico , Assistência Perioperatória , Idoso , Glicemia/análise , Diabetes Mellitus Tipo 2/sangue , Feminino , Glucose/uso terapêutico , Humanos , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Potássio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS