Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 51(6): 4069-4080, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38709908

RESUMO

PURPOSE: Assessing renal perfusion in-vivo is challenging and quantitative information regarding renal hemodynamics is hardly incorporated in medical decision-making while abnormal renal hemodynamics might play a crucial role in the onset and progression of renal disease. Combining physiological stimuli with rubidium-82 positron emission tomography/computed tomography (82Rb PET/CT) offers opportunities to test the kidney perfusion under various conditions. The aim of this study is: (1) to investigate the application of a one-tissue compartment model for measuring renal hemodynamics with dynamic 82Rb PET/CT imaging, and (2) to evaluate whether dynamic PET/CT is sensitive to detect differences in renal hemodynamics in stress conditions compared to resting state. METHODS: A one-tissue compartment model for the kidney was applied to cardiac 82Rb PET/CT scans that were obtained for ischemia detection as part of clinical care. Retrospective data, collected from 17 patients undergoing dynamic myocardial 82Rb PET/CT imaging in rest, were used to evaluate various CT-based volumes of interest (VOIs) of the kidney. Subsequently, retrospective data, collected from 10 patients (five impaired kidney functions and five controls) undergoing dynamic myocardial 82Rb PET/CT imaging, were used to evaluate image-derived input functions (IDIFs), PET-based VOIs of the kidney, extraction fractions, and whether dynamic 82Rb PET/CT can measure renal hemodynamics differences using the renal blood flow (RBF) values in rest and after exposure to adenosine pharmacological stress. RESULTS: The delivery rate (K1) values showed no significant (p = 0.14) difference between the mean standard deviation (SD) K1 values using one CT-based VOI and the use of two, three, and four CT-based VOIs, respectively 2.01(0.32), 1.90(0.40), 1.93(0.39), and 1.94(0.40) mL/min/mL. The ratio between RBF in rest and RBF in pharmacological stress for the controls were overall significantly lower compared to the impaired kidney function group for both PET-based delineation methods (region growing and iso-contouring), with the smallest median interquartile range (IQR) of 0.40(0.28-0.66) and 0.96(0.62-1.15), respectively (p < 0.05). The K1 of the impaired kidney function group were close to 1.0 mL/min/mL. CONCLUSIONS: This study demonstrated that obtaining renal K1 and RBF values using 82Rb PET/CT was feasible using a one-tissue compartment model. Applying iso-contouring as the PET-based VOI of the kidney and using AA as an IDIF is suggested for consideration in further studies. Dynamic 82Rb PET/CT imaging showed significant differences in renal hemodynamics in rest compared to when exposed to adenosine. This indicates that dynamic 82Rb PET/CT has potential to detect differences in renal hemodynamics in stress conditions compared to the resting state, and might be useful as a novel diagnostic tool for assessing renal perfusion.


Assuntos
Hemodinâmica , Rim , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos de Rubídio , Humanos , Masculino , Rim/diagnóstico por imagem , Rim/irrigação sanguínea , Feminino , Circulação Renal , Modelos Biológicos , Pessoa de Meia-Idade , Idoso , Processamento de Imagem Assistida por Computador/métodos , Estudos Retrospectivos
2.
Radiol Case Rep ; 19(5): 1855-1858, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38425773

RESUMO

The presence of healthy cartilage in the knee joint, featuring smooth articular surfaces, is crucial for normal physiological knee function. However, noninvasive in-vivo assessment of cartilage quality in the knee remains challenging and has not been thoroughly investigated. We aimed to illustrate two clinical cases, a 62-year-old male and a 67-year-old male, presented to the orthopaedic outpatient clinic with severe knee complaints. The novel combination of sodium fluoride-18 positron emission tomography/computed tomography and intra-articular injection of a contrast agent (Na[18F]F-PET/CT arthrography) was performed to evaluate cartilage defects of the knee as part of a prospective patient study. The lesion size observed on the Na[18F]F-PET was substantially larger compared to the findings on CT. This might indicate that Na[18F]F-PET/CT arthrography was able to image osseous and chondral pathological changes in an early stage and in a single procedure. Na[18F]F-PET/CT arthrography is a promising imaging technique and might extend the diagnostic potential of nuclear and radiological imaging in the evaluation of cartilage defects.

3.
JBMR Plus ; 8(2): ziad007, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38505528

RESUMO

Chronic nonbacterial osteitis (CNO) is a rare disease spectrum, which lacks biomarkers for disease activity. Sodium fluoride-18 positron emission tomography/computed tomography ([18F]NaF-PET/CT) is a sensitive imaging tool for bone diseases and yields quantitative data on bone turnover. We evaluated the capacities of [18F]NaF-PET/CT to provide structural and functional assessment in adult CNO. A coss-sectional study was performed including 43 adult patients with CNO and 16 controls (patients referred for suspected, but not diagnosed with CNO) who underwent [18F]NaF-PET/CT at our expert clinic. Structural features were compared between patients and controls, and maximal standardized uptake values (SUVmax [g/mL]) were calculated for bone lesions, soft tissue/joint lesions, and reference bone. SUVmax was correlated with clinical disease activity in patients. Structural assessment revealed manubrial and costal sclerosis/hyperostosis and calcification of the costoclavicular ligament as typical features associated with CNO. SUVmax of CNO lesions was higher compared with in-patient reference bone (mean paired difference: 11.4; 95% CI: 9.4-13.5; p < .001) and controls (mean difference: 12.4; 95%CI: 9.1-15.8; p < .001). The highest SUVmax values were found in soft tissue and joint areas such as the costoclavicular ligament and manubriosternal joint, and these correlated with erythrocyte sedimentation rate in patients (correlation coefficient: 0.546; p < .002). Our data suggest that [18F]NaF-PET/CT is a promising imaging tool for adult CNO, allowing for detailed structural evaluation of its typical bone, soft-tissue, and joint features. At the same time, [18F]NaF-PET/CT yields quantitative bone remodeling data that represent the pathologically increased bone turnover and the process of new bone formation. Further studies should investigate the application of quantified [18F]NaF uptake as a novel biomarker for disease activity in CNO, and its utility to steer clinical decision making.

4.
Nucl Med Commun ; 44(6): 495-501, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951877

RESUMO

OBJECTIVE: Since the end of 2019, the coronavirus disease 2019 (COVID-19) virus has infected millions of people, of whom a significant group suffers from sequelae from COVID-19, termed long COVID. As more and more patients emerge with long COVID who have symptoms of fatigue, myalgia and joint pain, we must examine potential biomarkers to find quantifiable parameters to define the underlying mechanisms and enable response monitoring. The aim of this study is to investigate the potential added value of [ 18 F]FDG-PET/computed tomography (CT) for this group of long COVID patients. METHODS: For this proof of concept study, we evaluated [ 18 F]FDG-PET/CT scans of long COVID patients and controls. Two analyses were performed: semi-quantitative analysis using target-to-background ratios (TBRs) in 24 targets and total vascular score (TVS) assessed by two independent nuclear medicine physicians. Mann-Whitney U -test was performed to find significant differences between the two groups. RESULTS: Thirteen patients were included in the long COVID group and 25 patients were included in the control group. No significant differences ( P  < 0.05) were found between the long COVID group and the control group in the TBR or TVS assessment. CONCLUSION: As we found no quantitative difference in the TBR or TVS between long COVID patients and controls, we are unable to prove that [ 18 F]FDG is of added value for long COVID patients with symptoms of myalgia or joint pain. Prospective cohort studies are necessary to understand the underlying mechanisms of long COVID.


Assuntos
COVID-19 , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Síndrome de COVID-19 Pós-Aguda , Estudo de Prova de Conceito , Estudos Prospectivos , Mialgia , COVID-19/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Compostos Radiofarmacêuticos
5.
Radiol Case Rep ; 16(11): 3478-3480, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34422149

RESUMO

A 56-year-old man presented to the emergency department with shortness of breath during the COVID-19 pandemic. Chest computed tomography angiography (CTa) showed bilateral peripheral ground-glass opacifications classified as CO-RADS 5, but no pulmonary embolism. To analyze the possibility of CTa-undetectable pulmonary microthrombi and to rule out cardiac perfusion abnormalities, we decided to perform a rubidium-82 (82Rb) PET/CT. 82Rb PET/CT imaging in this patient yielded uptake in the pulmonary areas of ground-glass opacification and showed corresponding findings between 82Rb PET/CT and CTa imaging without any signs of microthrombi despite the elevated d-dimer. Even in the areas of profound groundglass opacifications, the increased 82Rb uptake indicates that perfusion is adequate to acquire 82Rb uptake in the pulmonary cells. 82Rb PET/CT is a promising imaging technique and might extend the diagnostic potential of conventional nuclear and radiological imaging in detecting pulmonary microthrombi or other minor perfusion defects.

6.
EJNMMI Phys ; 8(1): 48, 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34132918

RESUMO

BACKGROUND: Quantitative SPECT enables absolute quantification of uptake in perfusion defects. The aim of this experimental study is to assess quantitative accuracy and precision of a novel iterative reconstruction technique (Evolution; GE Healthcare) for the potential application of response monitoring using 99mTc-tetrofosmin SPECT/CT in patients with coronary artery disease (CAD). METHODS: Acquisitions of an anthropomorphic torso phantom with cardiac insert containing defects (with varying sizes), filled with 99mTc-pertechnetate, were performed on a SPECT/CT (Discovery 670 Pro, GE Healthcare). Subsequently, volumes of interest of the defects were manually drawn on CT to assess the recovery coefficient (RC). Bull's eye plots were composed to evaluate the uptake per segment. Finally, 99mTc-tetrofosmin SPECT/CT scans of 10 CAD patients were used to illustrate clinical application. RESULTS: The phantom study indicated that Evolution showed convergence after 7 iterations and 10 subsets. The average repeatability deviation of all configurations was 2.91% and 3.15% (%SD mean) for filtered (Butterworth) and unfiltered data, respectively. The accuracy after post-filtering was lower compared to the unfiltered data with a mean (SD) RC of 0.63 (0.05) and 0.70 (0.07), respectively (p < 0.05). More artificial defects were found on Bull's eye plots created with the unfiltered data compared to filtered data. Eight out of ten patients showed significant changes in uptake before and after treatment (p < 0.05). CONCLUSION: Quantification of 99mTc-tetrofosmin SPECT/CT seems feasible for CAD patients when 7 iterations (10 subsets), Butterworth post-filtering (cut off frequency 0.52 in cycles/cm, order of 5) and manual CT-delineation are applied. However, future prospective patient studies are required for clinical application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...