1.
World J Pediatr Congenit Heart Surg ; 12(2): 230-233, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33684007

RESUMO

BACKGROUND: During unifocalization procedures for pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries, collateral arteries are either ligated or detached. Not much is known of the fate of the remaining arterial origins in the long term. Available computed tomography (CT) or magnetic resonance (MR) imaging of the intrathoracic arteries was examined to investigate possible abnormalities at the former position of the collateral arteries as well as ascending aortic diameters. METHODS: From 1989 to 2018, we performed 66 unifocalization procedures in 39 patients. One hundred and twenty-nine collateral arteries were ligated or detached. In 52% (15) of the surviving patients (with a total of 55 ligated or detached collaterals), sufficient imaging of the thoracic aorta from CT (11) and/or MR (9) was available for evaluation. RESULTS: The median interval between unifocalization procedure and imaging was 15 years (interquartile range [IQR]: 9-19 years). In 93% (14) of the scanned patients, 18 blunt ends were detected at the location of a former collateral artery. No aneurysm formation of the descending aorta was observed. The median diameter of the ascending aorta was 35 mm (IQR: 31-40 mm). During follow-up, no aortic dissection or rupture occurred. CONCLUSIONS: Aortic imaging late after unifocalization showed abnormalities in 93% of the scanned patients. Abnormalities consisted mostly of blunt ends of the former collateral artery. We recommend to include routine imaging of the aorta during late follow-up to detect eventual future abnormalities and monitor aortic diameters. Ascending aortic diameters showed slight dilatation with no clinical implications so far.


Assuntos
Aorta Torácica/anormalidades , Procedimentos Cirúrgicos Cardíacos/métodos , Circulação Colateral/fisiologia , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/anormalidades , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Ligadura , Imagem Cinética por Ressonância Magnética , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia
2.
Perfusion ; 30(4): 323-31, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25122118

RESUMO

OBJECTIVE: Priming-related hemodilution is the culprit behind excessive body water accumulation, postoperative coagulopathy and enhanced blood transfusion in infant cardiac surgery patients. In this retrospective, observational study, clinical data were analyzed to assess the effect of conventional ultrafiltration on allogenic blood transfusion and patient clinical outcome. METHODS: All infants with a bodyweight up to 10 kg who underwent consequent cardiac surgery in 2011 and 2012 were eligible for the audit. Seventy patients, operated in accordance with existing pediatric protocol, enrolled in the control group. The study group consisted of 55 patients who were operated employing conventional ultrafiltration during bypass and recently adjusted hematocrit targets. The following variables were primarily investigated: hematocrit and colloid osmotic pressure value, total volume of blood products transfused and duration of postoperative mechanical ventilation. Secondary outcome measures were: postoperative urine production, postoperative blood loss, length of stay at the intensive care unit and hospital stay. RESULTS: There were no significant differences between the groups in relation to demographics or hematological and cardiopulmonary bypass data. The ultrafiltration volume removed from circulation during bypass in the study group was 171 ± 99 ml. No significant difference between the groups was found with regard to the total allogenic blood transfusion (study group 216 ± 92 ml versus control group 191 ±93 ml; p = 0.136). All recorded clinical end points, duration of mechanical ventilation, duration of chest tube in situ, stay in ICU and stay in hospital, were similar between the groups. CONCLUSIONS: Routine use of conventional ultrafiltration during the cardiac surgery for patients with a bodyweight less than 10 kg was a safe technique that allowed us to achieve higher hematocrit levels at the end of the operation without additional transfusions of allogenic blood. On the other hand, ultrafiltration did not improve the clinical end points.


Assuntos
Transfusão de Sangue , Peso Corporal , Ponte Cardiopulmonar , Feminino , Hematócrito , Humanos , Lactente , Masculino , Estudos Retrospectivos , Ultrafiltração