Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38597226

RESUMO

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Seguimentos , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Osteoartrite do Joelho/cirurgia
2.
Bone Joint J ; 106-B(2): 136-143, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295835

RESUMO

Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results: Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion: The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Durapatita , Análise Radioestereométrica , Titânio , Seguimentos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
3.
J Bone Joint Surg Am ; 105(21): 1686-1694, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37651549

RESUMO

BACKGROUND: Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed. We investigated migration of a cementless 3D-printed and a cemented tibial component with otherwise similar TKA design during 5 years of follow-up, particularly the progression in migration beyond 2 years postoperatively. METHODS: Seventy-two patients were randomized to a cementless 3D-printed Triathlon Tritanium (Stryker) cruciate-retaining (CR) TKA or a cemented Triathlon CR (Stryker) TKA implant. Implant migration was evaluated with RSA at baseline and postoperatively at 3 months and at 1, 2, and 5 years. The maximum total point motion (MTPM) of the tibial component was compared between the groups at 5 years, and progression in migration was assessed between 2 and 5 years. Individual implants were classified as continuously migrating if the MTPM was ≥0.1 mm/year beyond 2 years postoperatively. Clinical scores were evaluated, and a linear mixed-effects model was used to analyze repeated measurements. RESULTS: At 5 years, the mean MTPM was 0.66 mm (95% confidence interval [CI], 0.56 to 0.78 mm) for the cementless group and 0.53 mm (95% CI, 0.43 to 0.64 mm) for the cemented group (p = 0.09). Between 2 and 5 years, there was no progression in mean MTPM for the cementless group (0.02 mm; 95% CI, -0.06 to 0.10 mm) versus 0.07 mm (95% CI, 0.00 to 0.14) for the cemented group. One implant was continuously migrating in the cementless group, and 4 were continuously migrating in the cemented group. The clinical scores were comparable between the groups across the entire time of follow-up. CONCLUSIONS: No significant difference in mean migration was found at 5 years between the cementless and cemented TKA implants. Progression of tibial component migration was present beyond 2 years for the cemented implant, whereas the cementless implant remained stable after initial early migration. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Análise Radioestereométrica/métodos , Osteoartrite do Joelho/cirurgia , Cimentos Ósseos/uso terapêutico , Impressão Tridimensional , Falha de Prótese , Desenho de Prótese , Resultado do Tratamento
4.
Knee ; 38: 91-106, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35964436

RESUMO

BACKGROUND: Considerable interindividual variation in meniscal microvascularization has been reported. The purpose of this review was to identify which patient characteristics affect meniscal microvascularization and provide a structured overview of angiogenic therapies that influence meniscal neovascularization. METHODS: A systematic literature search was undertaken using PubMed, Embase, Web of Science, Cochrane library and Emcare from inception to November 2021. Studies reporting on (1) Patient characteristics that affect meniscal microvascularization, or (2) Therapies that induce neovascularization in meniscal tissue were included. Studies were graded in quality using the Anatomical Quality Assessment (AQUA) tool. The study was registered with PROSPERO(ID:CRD42021242479). RESULTS: Thirteen studies reported on patient characteristics and eleven on angiogenic therapies. The influence of Age, Degenerative knee, Gender, and Race was reported. Age is the most studied factor. The entire meniscus is vascularized around birth. With increasing age, vascularization decreases from the inner to the peripheral margin. Around 11 years, blood vessels are primarily located in the peripheral third of the menisci. There seems to be a further decrease in vascularization with increasing age in adults, yet conflicting literature exists. Degenerative changes of the knee also seem to influence meniscal vascularization, but evidence is limited. Angiogenic therapies to improve meniscal vascularization have only been studied in preclinical setting. The use of synovial flap transplantation, stem cell therapy, vascular endothelial growth factor, and angiogenin has shown promising results. CONCLUSION: To decrease failure rates of meniscal repair, a better understanding of patient-specific vascular anatomy is essential. Translational clinical research is needed to investigate the clinical value of angiogenic therapies.


Assuntos
Menisco , Lesões do Menisco Tibial , Adulto , Humanos , Meniscectomia/métodos , Meniscos Tibiais/cirurgia , Microvasos , Lesões do Menisco Tibial/cirurgia , Fator A de Crescimento do Endotélio Vascular
5.
Knee Surg Sports Traumatol Arthrosc ; 30(5): 1629-1638, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34347140

RESUMO

PURPOSE: The purpose of this study was to assess whether the vascularisation of the meniscus could be visualised intra-operatively using near-infrared fluorescence (NIRF) imaging with indocyanine green (ICG) in patients undergoing total knee arthroplasty (TKA). METHODS: The anterior horn (i.e., Cooper classification: zones C and D) of the meniscus that was least affected (i.e., least degenerative) was removed during TKA surgery in ten patients to obtain a cross section of the inside of the meniscus. Thereafter, 10 mg of ICG was injected intravenously, and vascularisation of the cross section of the meniscus was assessed using the Quest spectrum NIRF camera system. We calculated the percentage of patients in whom vascularisation was observed intra-operatively using NIRF imaging compared to immunohistochemistry. RESULTS: Meniscal vascularisation using NIRF imaging was observed in six out of eight (75%) patients in whom vascularisation was demonstrated with immunohistochemistry. The median extent of vascularisation was 13% (interquartile range (IQR) 3-28%) using NIRF imaging and 15% (IQR 11-23%) using immunohistochemistry. CONCLUSION: This study shows the potential of NIRF imaging to visualise vascularisation of the meniscus, as vascularisation was observed in six out of eight patients with histologically proven meniscal vascularisation. LEVEL OF EVIDENCE: IV.


Assuntos
Menisco , Imagem Óptica , Humanos , Verde de Indocianina , Imagem Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...