Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Clin Immunol ; 264: 110252, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38744408

RESUMO

Children with Multisystem Inflammatory Syndrome in Children (MIS-C) can present with thrombocytopenia, which is a key feature of hemophagocytic lymphohistiocytosis (HLH). We hypothesized that thrombocytopenic MIS-C patients have more features of HLH. Clinical characteristics and routine laboratory parameters were collected from 228 MIS-C patients, of whom 85 (37%) were thrombocytopenic. Thrombocytopenic patients had increased ferritin levels; reduced leukocyte subsets; and elevated levels of ASAT and ALAT. Soluble IL-2RA was higher in thrombocytopenic children than in non-thrombocytopenic children. T-cell activation, TNF-alpha and IFN-gamma signaling markers were inversely correlated with thrombocyte levels, consistent with a more pronounced cytokine storm syndrome. Thrombocytopenia was not associated with severity of MIS-C and no pathogenic variants were identified in HLH-related genes. This suggests that thrombocytopenia in MIS-C is not a feature of a more severe disease phenotype, but the consequence of a distinct hyperinflammatory immunopathological process in a subset of children.


Assuntos
Linfo-Histiocitose Hemofagocítica , Síndrome de Resposta Inflamatória Sistêmica , Trombocitopenia , Humanos , Linfo-Histiocitose Hemofagocítica/sangue , Linfo-Histiocitose Hemofagocítica/imunologia , Linfo-Histiocitose Hemofagocítica/genética , Criança , Masculino , Pré-Escolar , Feminino , Síndrome de Resposta Inflamatória Sistêmica/sangue , Síndrome de Resposta Inflamatória Sistêmica/imunologia , Trombocitopenia/sangue , Trombocitopenia/imunologia , Lactente , Adolescente , Fenótipo , Proteômica , COVID-19/imunologia , COVID-19/sangue , COVID-19/complicações
2.
Scand Cardiovasc J ; 58(1): 2330347, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38555873

RESUMO

Objectives. To describe current on- (isolated coronary arterty bypass grafting, iCABG) and off-label (non-iCABG) use of aprotinin and associated safety endpoints in adult patients undergoing high-risk cardiac surgery in Nordic countries. Design. Data come from 10 cardiac surgery centres in Finland, Norway and Sweden participating in the European Nordic aprotinin patient registry (NAPaR). Results. 486 patients were given aprotinin between 2016 and 2020. 59 patients (12.1%) underwent iCABG and 427 (87.9%) non-iCABG, including surgery for aortic dissection (16.7%) and endocarditis (36.0%). 89.9% were administered a full aprotinin dosage and 37.0% were re-sternotomies. Dual antiplatelet treatment affected 72.9% of iCABG and 7.0% of non-iCABG patients. 0.6% of patients had anaphylactic reactions associated with aprotinin. 6.4% (95 CI% 4.2%-8.6%) of patients were reoperated for bleeding. Rate of postoperative thromboembolic events, day 1 rise in creatinine >44µmol/L and new dialysis for any reason was 4.7% (95%CI 2.8%-6.6%), 16.7% (95%CI 13.4%-20.0%) and 14.0% (95%CI 10.9%-17.1%), respectively. In-hospital mortality and 30-day mortality was 4.9% (95%CI 2.8%-6.9%) and 6.3% (95%CI 3.7%-7.8%) in all patients versus mean EuroSCORE II 11.4% (95%CI 8.4%-14.0%, p < .01). 30-day mortality in patients undergoing surgery for aortic dissection and endocarditis was 6.2% (95%CI 0.9%-11.4%) and 6.3% (95%CI 2.7%-9.9%) versus mean EuroSCORE II 13.2% (95%CI 6.1%-21.0%, p = .11) and 14.5% (95%CI 12.1%-16.8%, p = .01), respectively. Conclusions. NAPaR data from Nordic countries suggest a favourable safety profile of aprotinin in adult cardiac surgery.


Assuntos
Dissecção Aórtica , Procedimentos Cirúrgicos Cardíacos , Endocardite , Hemostáticos , Adulto , Humanos , Aprotinina/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Hemostáticos/efeitos adversos
3.
Front Psychol ; 14: 1249615, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954182

RESUMO

Introduction: This study investigates the moderating role of supervisor emotional support at the group level on the relationship between emotional exhaustion and work engagement with organizational citizenship behavior-civic virtue (OCB-civic virtue) at the individual level among nurses. Method: A cross-sectional study was carried out on 558 nurses nested in 36 working units from two hospitals in Algiers. A multilevel analysis using Hierarchical Linear Modeling was performed. Results: Results show that the positive effect of work engagement on OCB-civic virtue was moderated by supervisor emotional support at group level. The nurses emotional exhaustion and OCB-civic virtue negative relationship at the individual level is buffered by supervisor emotional support at group level. Discussion: In consequence, supervisor emotional support experienced by the team has an influence on the emotional exhaustion and work engagement OCB-civic virtue relationship.

4.
Pediatr Infect Dis J ; 42(12): 1077-1085, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37823702

RESUMO

BACKGROUND: SARS-CoV-2 variant evolution and increasing immunity altered the impact of pediatric SARS-CoV-2 infection. Public health decision-making relies on accurate and timely reporting of clinical data. METHODS: This international hospital-based multicenter, prospective cohort study with real-time reporting was active from March 2020 to December 2022. We evaluated longitudinal incident rates and risk factors for disease severity. RESULTS: We included 564 hospitalized children with acute COVID-19 (n = 375) or multisystem inflammatory syndrome in children (n = 189) from the Netherlands, Curaçao and Surinam. In COVID-19, 134/375 patients (36%) needed supplemental oxygen therapy and 35 (9.3%) required intensive care treatment. Age above 12 years and preexisting pulmonary conditions were predictors for severe COVID-19. During omicron, hospitalized children had milder disease. During population immunity, the incidence rate of pediatric COVID-19 infection declined for older children but was stable for children below 1 year. The incidence rate of multisystem inflammatory syndrome in children was highest during the delta wave and has decreased rapidly since omicron emerged. Real-time reporting of our data impacted national pediatric SARS-CoV-2 vaccination- and booster-policies. CONCLUSIONS: Our data supports the notion that similar to adults, prior immunity protects against severe sequelae of SARS-CoV-2 infections in children. Real-time reporting of accurate and high-quality data is feasible and impacts clinical and public health decision-making. The reporting framework of our consortium is readily accessible for future SARS-CoV-2 waves and other emerging infections.


Assuntos
COVID-19 , Adolescente , Criança , Humanos , COVID-19/epidemiologia , Vacinas contra COVID-19 , Estudos Prospectivos , SARS-CoV-2
5.
Eur J Anaesthesiol ; 39(8): 685-694, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35766393

RESUMO

BACKGROUND: Aprotinin has been used to reduce blood loss and blood product transfusions in patients at high risk of major blood loss during cardiac surgery. Approval by the European Medicines Agency (EMA) for its current indication is limited to patients at high risk of major blood loss undergoing isolated coronary artery bypass graft surgery (iCABG). OBJECTIVE: To report current real-world data on the use and certain endpoints related to the safety of aprotinin in adult patients. DESIGN: The Nordic aprotinin patient registry (NAPaR) received data from 83 European centres in a noninterventional, postauthorisation safety study (PASS) performed at the request of the EMA. SETTING: Cardiac surgical centres committed to enrolling patients in the NAPaR. PATIENTS: Patients receiving aprotinin agreeing to participate. INTERVENTION: The decision to administer aprotinin was made by the treating physicians. MAIN OUTCOME MEASURES: Aprotinin safety endpoints were in-hospital death, thrombo-embolic events (TEEs), specifically stroke, renal impairment, re-exploration for bleeding/tamponade. RESULTS: From 2016 to 2020, 5309 patients (male 71.5%; >75 years 18.9%) were treated with aprotinin; 1363 (25.7%) underwent iCABG and 3946 (74.3%) another procedure, including a surgical treatment for aortic dissection ( n  = 660, 16.7%); 54.5% of patients received the full-dose regimen. In-hospital mortality in iCABG patients was 1.3% (95% CI, 0.66 to 1.84%) vs. 8.3% (7.21 to 8.91%) in non-iCABG patients; incidence of TEEs and postoperative rise in creatinine level greater than 44 µmol l -1 2.3% (1.48 to 3.07%) and 2.7% (1.79 to 3.49%) vs. 7.2% (6.20 to 7.79%) and 15.5% (13.84 to 16.06%); patients undergoing re-exploration for bleeding 1.4% (0.71 to 1.93%) vs. 3.0% (2.39 to 3.44%). Twelve cases of hypersensitivity/anaphylactic reaction (0.2%) were reported as Adverse Drug Reactions. CONCLUSION: The data in the NApaR indicated that in this patient population, at high risk of death or blood loss undergoing cardiac surgery, including complex cardiac surgeries other than iCABG, the incidence of adverse events is in line with data from current literature, where aprotinin was not used. TRIAL REGISTRATION: EU PAS register number: EUPAS11384.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hemostáticos , Cirurgia Torácica , Aprotinina/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte de Artéria Coronária/efeitos adversos , Hemostáticos/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino
6.
TH Open ; 6(1): e50-e59, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35265789

RESUMO

Background Severe disease due to the novel coronavirus disease 2019 (COVID-19) has been shown to be associated with hypercoagulation. The aim of this study was to assess the Rotational Thromboelastometry (ROTEM) as a marker of coagulopathy in hospitalized COVID-19 patients. Methods This was a prospective, observational study where patients hospitalized due to a COVID-19 infection were eligible for inclusion. Conventional coagulation tests and ROTEM were taken after hospital admission, and patients were followed for 30 days. A prediction model, including variables ROTEM EXTEM-MCF (Maximum Clot Firmness) which in previous data has been suggested a suitable marker of hypercoagulation, age, and respiratory frequency, was developed using logistic regression to evaluate the probability of death. Results Out of the 141 patients included, 18 (13%) died within 30 days. In the final prediction model, the risk of death within 30 days for a patient hospitalized due to COVID-19 was increased with increased EXTEM-MCF, age, and respiratory frequency. Longitudinal ROTEM data in the severely ill subpopulation showed enhanced hypercoagulation. In an in vitro analysis, no heparin effect on EXTEM-coagulation time (CT) was observed, supporting a severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) effect on prolonged initiation of coagulation. Conclusion Here, we show that hypercoagulation measured with ROTEM predicts 30-day mortality in COVID-19. Longitudinal ROTEM data strengthen the hypothesis of hypercoagulation as a driver of severe disease in COVID-19. Thus, ROTEM may be a useful tool to assess disease severity in COVID-19 and could potentially guide anticoagulation therapy.

7.
Interact Cardiovasc Thorac Surg ; 33(3): 483-488, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34363470

RESUMO

OBJECTIVES: Carbon dioxide (CO2) gas insufflation is used for continuous de-airing during open heart surgery. The aim was to evaluate if an additional separate venous reservoir eliminates CO2 insufflation-induced hypercapnia and keeps sweep gas flow of the oxygenator constant. METHODS: A separate reservoir was used during cardiopulmonary bypass in addition to a standard venous reservoir. The additional reservoir received drained blood and CO2 gas continuously via a suction drain (1 l/min) and handheld suction devices from the surgical wound. CO2 gas was insufflated via a gas diffuser in the open wound at 10 l/min. In a cross-over design for each patient, gas and blood were either continuously drained from the additional to the standard venous reservoir or not. CO2 pressure in arterial blood (PaCO2) was measured after adjustment of sweep gas flow as necessary and after steady state of PaCO2 was observed. Mean values for each setup (median 4 times) for each patient were analysed with Wilcoxon rank-sum test. RESULTS: Ten adult patients undergoing open aortic valve replacement were included. Median PaCO2 did not differ between setups (5.41; 5.29-5.57, interquartile range vs 5.41; 5.24-5.58, P = 0.92), whereas sweep gas flow (l/min) was lower (2.58; 2.50-3.16 vs 4.42; 4.0-5.40, P = 0.002) when CO2 gas was not drained from the additional to the standard reservoir. CONCLUSIONS: An additional venous reservoir for the evacuation of blood from the open surgical wound eliminates CO2 insufflation-induced hypercapnia in open heart surgery keeping PaCO2 and sweep gas flow constant. This prevents possible CO2-induced hyperperfusion of the brain and decreases the risk of cerebral particulate embolization during CO2 insufflation for de-airing in open heart surgery. CLINICAL TRIAL REGISTRATION: NCT04202575. IRB APPROVAL DAT AND NUMBER: 2018-07-13 and 2018/1091-31.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuflação , Dispositivos de Acesso Vascular , Adulto , Dióxido de Carbono , Humanos , Hipercapnia/etiologia , Insuflação/efeitos adversos
8.
Sensors (Basel) ; 21(2)2021 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-33435177

RESUMO

Capacitance-based automatic urine measurement is a validated technique already implemented in clinical practice. However, albuminuria and free hemoglobinuria cause progressive biofilm buildup on the capacitance sensors of the urinometers. The aim of this experimental study is to investigate the influence of albumin and free hemoglobin on the capacitance signal of an automatic urinometer with and without the addition of silicone oil. A solution of Ringer's acetate mixed with either albumin or free hemoglobin was run through an automatic urinometer containing either a water-soluble capsule with silicone oil or not. In total, around 500 capacitance measurements were retrieved from the albumin and free hemoglobin group, respectively. The mean increase in capacitance in the albumin 3 g/L group was 257 ± 100 pF without and 105 ± 30 pF with silicone oil, respectively, during 24 h. After ten hours of recording, differences between the two albumin groups reached statistical significance. For the free hemoglobin groups (0.01 g/L), the mean increase in capacitance was 190 ± 170 pF with silicone oil, and 324 ± 80 pF without, with a significant difference between the groups after 20 h and onwards. Coating of the capacitance measurement membrane of the automatic urinometer by albumin or free hemoglobin was significantly decreased by silicone oil, prolonging the functionality of the device.


Assuntos
Hemoglobinas , Óleos de Silicone , Biofilmes
9.
J Thromb Thrombolysis ; 51(2): 437-445, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33068277

RESUMO

High prevalence of thrombotic events in severely ill COVID-19 patients have been reported. Pulmonary embolism as well as microembolization of vital organs may in these individuals be direct causes of death. The identification of patients at high risk of developing thrombosis may lead to targeted, more effective prophylactic treatment. The primary aim of this study was to test whether rotational thromboelastometry (ROTEM) at admission indicates hypercoagulopathy and predicts the disease severity, assessed as care level, in COVID-19 patients. The study was designed as a prospective, observational study where COVID-19 patients over 18 years admitted to hospital were eligible for inclusion. Patients were divided into two groups depending on care level: (1) regular wards or (2) wards with specialized ventilation support. Conventional coagulation tests, blood type and ROTEM were taken at admission. 60 patients were included; age 61 (median), 67% men, many with comorbidities (e.g. hypertension, diabetes). The ROTEM variables Maximum Clot Firmness (EXTEM-/FIBTEM-MCF) were higher in COVID-19 patients compared with in healthy controls (p < 0.001) and higher in severely ill patients compared with in patients at regular wards (p < 0.05). Our results suggest that hypercoagulopathy is present early in patients with mild to moderate disease, and more pronounced in severe COVID-19 pneumonia. Non-O blood types were not overrepresented in COVID-19 positive patients. ROTEM variables showed hypercoagulopathy at admission and this pattern was more pronounced in patients with increased disease severity. If this feature is to be used to predict the risk of thromboembolic complications further studies are warranted.


Assuntos
COVID-19 , SARS-CoV-2 , Trombose , Adulto , Idoso , COVID-19/sangue , COVID-19/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tromboelastografia , Trombose/sangue , Trombose/etiologia
10.
Crit Care Explor ; 2(12): e0308, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33364605

RESUMO

To determine the prevalence of thrombotic events, functional coagulation tests, inflammatory biomarkers, and antiphospholipid antibodies before and after enhanced anticoagulation in critically ill coronavirus disease 2019 patients. DESIGN: Retrospective. SETTING: Tertiary intensive care unit. PATIENTS: Two cross-sectional cohorts of ICU-treated coronavirus disease 2019 patients were included before (cohort 1, n = 12) and after (cohort 2, n = 14) enhanced prophylactic anticoagulation strategy. INTERVENTIONS: Before and after study of enhanced anticoagulation. MEASUREMENTS AND MAIN RESULTS: Thromboelastometry point-of-care coagulation tests were performed by thromboelastography (Tem International GmbH, Munich, Germany), standard blood tests were extracted from patient charts, and presence of antiphospholipid antibodies in plasma was measured. All patients were males on mechanical ventilation. In cohort 1 (low-molecular-weight heparin dose: 129 ± 53 U/kg/24 hr), 50% had pulmonary embolism, and thromboelastography analysis revealed hypercoagulation in a majority of patients and greater than 80% had detectable antiphospholipid antibodies. In the second cohort (enhanced low-molecular-weight heparin dose: 200 ± 82 U/kg/24 hr; p = 0.04 vs cohort 1), we found a nonsignificantly lower prevalence of pulmonary embolism (21%; p = 0.22), lower fibrinogen (6.3 ± 2.5 vs 8.7 ± 2.0; p = 0.02), reduced fibrinogen-dependent thromboelastography (p < 0.001), and lower inflammatory markers. CONCLUSIONS: In these two cross-sectional cohorts of ICU-treated coronavirus disease 2019 patients, thromboembolic complications, hypercoagulation, and antiphospholipid antibodies were common. A more aggressive anticoagulation regime was associated with a reduction in inflammatory biomarkers including plasma fibrinogen and a reduction in fibrinogen-dependent hypercoagulation, as indicated by thromboelastography analyses.

11.
Transfus Med ; 30(5): 369-376, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32196802

RESUMO

OBJECTIVES: The aim of this study was to investigate whether ROTEM platelet can provide additional information to the traditional ROTEM analysis to guide treatment with platelet transfusions in cardiac surgery and to identify factors triggering platelet administration. BACKGROUND: Platelets play a crucial role in coagulation and haemostasis after cardiac surgery. Excessive bleeding after cardiopulmonary bypass usually requires transfusions of blood products, including platelets. The ROTEM platelet is a novel point-of-care analysis for whole blood. MATERIALS AND METHODS: We included 23 patients scheduled for complex cardiac surgery. ROTEM (in-tem, ex-tem), ROTEM platelet (ARA-tem, ADP-tem and TRAP-tem) and platelet count were analysed before induction of anaesthesia (T0), after cardiopulmonary bypass and protamine reversal (T1) and after platelet transfusion (T2, n = 10). RESULTS: ROTEM and ROTEM platelet tests were all significantly reduced between T0 and T1. ROTEM parameters improved significantly after platelet transfusion. Regarding ROTEM platelet, only TRAP-tem increased between T1 and T2 (P = .008). Factors triggering platelet transfusion were long duration of surgery and time on cardiopulmonary bypass. CONCLUSION: ROTEM platelet with thrombin activation, TRAP-tem, improved significantly, indicating that platelet transfusion may reverse cardiopulmonary bypass-induced platelet dysfunction. Further studies are needed to evaluate whether TRAP-tem can be a valuable analysis regarding indications for transfusion of platelets after extensive cardiac surgery.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Plaquetas/metabolismo , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Transfusão de Plaquetas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Função Plaquetária , Estudos Prospectivos
12.
Lakartidningen ; 1172020 01 27.
Artigo em Sueco | MEDLINE | ID: mdl-31990361

RESUMO

During the last decade, the varying use and the lack of consistent indications for blood transfusions have been questioned. Comparisons of liberal and restrictive transfusion policies, most often support a restrictive policy. This has led to an evidence-based approach to optimizing the care of patients who might need transfusion, Patient Blood Management (PBM). There is evidence that both anemia and allogeneic blood transfusions are independently associated with increased morbidity and mortality. In elective surgery it is possible to adapt the three pillars of PBM in a structured way; i.e. optimization of red blood cell mass, reduction of blood loss and bleeding, and optimization of the patient's physiological tolerance towards anemia. These activities should be included in the pre-peri- and postoperative routines, in all surgical units.


Assuntos
Anemia , Transfusão de Sangue , Hemorragia , Anemia/terapia , Hemorragia/terapia , Humanos
15.
Pediatr Crit Care Med ; 20(8): 769-772, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31169763

RESUMO

OBJECTIVES: To compare a modified capacitance-based automatic urinometer to a manual urinometer, with regard to precision of measurement and to evaluate the staff's opinion regarding the automatic urinometer. DESIGN: Prospective observational cohort study. SETTING: PICU at Astrid Lindgren's Children Hospital in Solna, Sweden. PATIENTS: Twelve children weighing up to 10 kg with an indwelling urinary catheter in place before enrollment. INTERVENTIONS: Measurement of hourly diuresis using either an automatic urinometer or manual urinometer. MEASUREMENTS AND MAIN RESULTS: Hourly diuresis was measured with an automatic urinometer (n = 127; Sippi; Observe Medical Nordic AB, Gothenburg, Sweden) or an manual urinometer (n = 83; Unometer Safeti Plus; Convatec, Lejre, Denmark) and thereafter validated with a measuring cylinder. The absolute mean bias was -1.1 mL for the automatic urinometer (CI, -0.6 to -1.5) and -0.6 mL (CI, ± 0.0 to -1.2) for the manual urinometer (p = 0.21). The SDs were 2.6 and 2.8 mL, respectively. User evaluation comparing the automatic urinometer with the manual urinometer concerning the ease of use was made with a questionnaire (n = 18). The majority of staff preferred the automatic urinometer to the manual urinometer in terms of ease of use, learning, and handling. CONCLUSIONS: The two urinometers were comparable in performance for children weighing up to 10 kg. Taking into account the overwhelming staff satisfaction with the automatic urinometer and benefits in less well-staffed wards as well as lack of temporal deviation, the modified automatic urinometer may be considered for clinical use in the PICU.


Assuntos
Diurese , Pesos e Medidas/instrumentação , Injúria Renal Aguda/terapia , Cateteres de Demora , Pré-Escolar , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Projetos Piloto , Estudos Prospectivos , Método Simples-Cego , Urina
16.
Crit Care Med ; 47(7): 926-933, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31094743

RESUMO

OBJECTIVES: Mortality after cardiac arrest remains high despite initiation of venoarterial extracorporeal membrane oxygenation. We aimed to identify pre-venoarterial extracorporeal membrane oxygenation risk factors of 90-day mortality in patients with witnessed cardiac arrest and with greater than or equal to 1 minute of cardiopulmonary resuscitation before venoarterial extracorporeal membrane oxygenation. The association between preimplant variables and all-cause mortality at 90 days was analyzed with multivariable logistic regression. DESIGN: Retrospective observational cohort study. SETTING: Tertiary medical center. PATIENTS: Seventy-two consecutive patients with cardiac arrest prior to venoarterial extracorporeal membrane oxygenation cannulation. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Median age was 56 years (interquartile range, 43-56 yr), 75% (n = 54) were men. Out-of-hospital cardiac arrest occurred in 12% (n = 9) of the patients. Initial cardiac rhythm was nonshockable in 57% (n = 41) and shockable in 43% (n = 31) of patients. Median cardiopulmonary resuscitation duration was 21 minutes (interquartile range, 10-73 min; range, 1-197 min]. No return of spontaneous circulation was present in 64% (n = 46) and postarrest cardiogenic shock in 36% (n = 26) of the patients at venoarterial extracorporeal membrane oxygenation cannulation. Median duration of venoarterial extracorporeal membrane oxygenation was 5 days (interquartile range, 2-12 d). The 90-day overall mortality and in-hospital mortality were 57% (n = 41), 53% (n = 38) died during venoarterial extracorporeal membrane oxygenation, and 43% (n = 31) were successfully weaned. All survivors had Cerebral Performance Category score 1-2 at discharge to home. Multivariable logistic regression analysis identified initial nonshockable cardiac arrest rhythm (odds ratio, 12.2; 95% CI, 2.83-52.7; p = 0.001), arterial lactate (odds ratio per unit, 1.15; 95% CI, 1.01-1.31; p = 0.041), and ischemic heart disease (7.39; 95% CI, 1.57-34.7; p = 0.011) as independent risk factors of 90-day mortality, whereas low-flow duration, return of spontaneous circulation, and age were not. CONCLUSIONS: In 72 patients with cardiac arrest before venoarterial extracorporeal membrane oxygenation initiation, nonshockable rhythm, arterial lactate, and ischemic heart disease were identified as independent pre-venoarterial extracorporeal membrane oxygenation risk factors of 90-day mortality. The novelty of this study is that the metabolic state, expressed as level of lactate just before venoarterial extracorporeal membrane oxygenation initiation seems more predictive of outcome than cardiopulmonary resuscitation duration or absence of return of spontaneous circulation.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Parada Cardíaca/mortalidade , Parada Cardíaca/terapia , Adolescente , Adulto , Idoso , Arritmias Cardíacas/etiologia , Reanimação Cardiopulmonar/métodos , Criança , Comorbidade , Feminino , Parada Cardíaca/complicações , Humanos , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Suécia/epidemiologia , Fatores de Tempo , Adulto Jovem
17.
Resuscitation ; 139: 253-261, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31028826

RESUMO

BACKGROUND: The clinical importance of immediate coronary angiography, with potentially subsequent percutaneous coronary intervention (PCI), in out-of-hospital cardiac arrest (OHCA) patients without ST-elevation on the ECG is unclear. In this study, we assessed feasibility and safety aspects of performing immediate coronary angiography in a pre-specified pilot phase of the 'DIrect or Subacute Coronary angiography in Out-of-hospital cardiac arrest' (DISCO) randomized controlled trial (ClinicalTrials.gov ID: NCT02309151). METHODS: Resuscitated bystander witnessed OHCA patients >18 years without ST-elevation on the ECG were randomized to immediate coronary angiography versus standard of care. Event times, procedure related adverse events and safety variables within 7 days were recorded. RESULTS: In total, 79 patients were randomized to immediate angiography (n = 39) or standard of care (n = 40). No major differences in baseline characteristics between the groups were found. There were no differences in the proportion of bleedings and renal failure. Three patients randomized to immediate angiography and six patients randomized to standard care died within 24 h. The median time from EMS arrival to coronary angiography was 135 min in the immediate angiography group. In patients randomized to immediate angiography a culprit lesion was found in 14/38 (36.8%) and PCI was performed in all these patients. In 6/40 (15%) patients randomized to standard of care, coronary angiography was performed before the stipulated 3 days. CONCLUSION: In this out-of-hospital cardiac arrest population without ST-elevation, randomization to a strategy to perform immediate coronary angiography was feasible although the time window of 120 min from EMS arrival at the scene of the arrest to start of coronary angiography was not achieved. No significant safety issues were reported.


Assuntos
Angiografia Coronária , Parada Cardíaca Extra-Hospitalar/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/cirurgia , Intervenção Coronária Percutânea , Projetos Piloto , Fatores de Tempo
18.
J Cataract Refract Surg ; 45(5): 582-586, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30826241

RESUMO

PURPOSE: To evaluate the accuracy of different intraocular lens (IOL) power calculation formulas available on the American Society of Cataract and Refractive Surgery calculator in calculating multifocal IOL power in eyes with previous hyperopic corneal refractive laser surgery. DESIGN: Retrospective case series. SETTING: Amsterdam University Medical Center, University of Amsterdam, and Retina Total Eye Care, Driebergen, the Netherlands. METHODS: This study compared the accuracy of 3 formulas using historical refractive data (ie, Masket, modified Masket, and Barrett True-K) and 3 formulas using no previous refractive data (ie, Shammas, Haigis-L, and Barrett True-K no-history). RESULTS: Sixty-four eyes were included. The variance of the prediction error of the various formulas was similar and ranged from 0.27 D2 to 0.33 D2 (P = .99). The modified Masket formula had a significantly higher median absolute prediction error than the Masket formula, Barrett True-K formula, and mean value of all formulas (P < .001). CONCLUSION: All formulas showed comparable accuracy in predicting IOL power in eyes after hyperopic corneal refractive laser surgery except for the modified Masket formula, which performed less accurately than the Masket formula, Barrett True-K formula, and mean value of all formulas.


Assuntos
Biometria/métodos , Cirurgia da Córnea a Laser , Hiperopia/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Óptica e Fotônica , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmologia/organização & administração , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sociedades Médicas , Acuidade Visual/fisiologia
19.
J Cardiothorac Surg ; 14(1): 12, 2019 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-30654802

RESUMO

BACKGROUND: Arterial air embolism during open heart surgery may cause postoperative complications including cerebral injury, myocardial dysfunction, and dysrhythmias. Despite standard de-airing techniques during surgery large amounts of arterial air emboli may still occur, especially during weaning from cardiopulmonary bypass. To prevent this insufflation of carbon dioxide in the wound cavity has been used since the 1950s. The aim of this study was to assess a new mini-diffuser for efficient carbon dioxide de-airing of a minimal invasive cardiothoracic wound cavity model. Up until now no device has been evaluated for this purpose. METHODS: A new insufflation device, a mini-diffuser, was tested. A thin plastic tube was used as control. The end of the mini-diffuser or the control, respectively, was positioned in a minimal invasive thoracic wound model. Remaining air content was measured during steady state and during intermittent suction with a rough suction device at different carbon dioxide flow rates. Measurements were also carried out in the open surgical wound during minimal invasive aortic surgery in six patients. RESULTS: The air content was below 1% 4 cm below the surface of the open wound model during continuous carbon dioxide inflow of 2-10 L/min with the mini diffuser. In comparison, carbon dioxide insufflation via the open-ended tube resulted in a mean air content between 10 and 75%. The mean air content of the wound model remained below 1% at a carbon dioxide flow rate of 3-5 L/min during intermittent application of a suction device with a suction rate of 15 L/min. In 6 patients undergoing minimal invasive aortic valve replacement air content in the open surgical wound remained below 1% at a continuous carbon dioxide flow rate of 5 and 8 L/min via the mini-diffuser, respectively. CONCLUSIONS: The mini diffuser was effective for carbon dioxide de-airing, i.e. < 1% remaining air, of a minimal invasive cardiothoracic wound cavity model with and without intermittent rough suction as well as in patients undergoing minimal invasive aortic valve surgery.


Assuntos
Dióxido de Carbono/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Embolia Aérea/terapia , Insuflação/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Complicações Pós-Operatórias , Embolia Aérea/etiologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
J Am Heart Assoc ; 8(2): e010152, 2019 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-30636504

RESUMO

Background Morphine administration is a strong predictor of delayed onset of action of orally administered ticagrelor in patients with ST-segment-elevation myocardial infarction, likely because of impaired gastrointestinal motility. The aim of this study was to evaluate whether the peripheral opioid antagonist methylnaltrexone could improve pharmacodynamics and pharmacokinetics of orally administered ticagrelor in patients with ST-segment-elevation myocardial infarction receiving morphine. Methods and Results The MOVEMENT (Methylnaltrexone to Improve Platelet Inhibition of Ticagrelor in Morphine-Treated Patients With ST-Segment Elevation Myocardial Infarction) trial was a multicenter, prospective, randomized, controlled trial in patients with ST-segment-elevation myocardial infarction treated with morphine and ticagrelor. Upon arrival to the catheterization laboratory, patients were randomized to a blinded intravenous injection of either methylnaltrexone (8 or 12 mg according to weight) or 0.9% sodium chloride. The proportion of patients with high on-treatment platelet reactivity and plasma concentrations of ticagrelor and AR -C124910XX were assessed at baseline (arrival in the catheterization laboratory) and 1 and 2 hours later. A total of 82 patients received either methylnaltrexone (n=43) or placebo (n=39). Median (interquartile range) time from ticagrelor administration to randomization was 41 (31-50) versus 45.5 (37-60) minutes ( P=0.16). Intravenous methylnaltrexone administration did not significantly affect prevalence of high on-treatment platelet reactivity at 2 hours after inclusion, the primary end point, when compared with placebo (54% versus 51%, P=0.84). Plasma concentrations of ticagrelor and its active metabolite, the prespecified secondary end points, did not differ significantly between the groups over time. There was no significant difference in patient self-estimated pain between the groups. Conclusions Methylnaltrexone did not significantly improve platelet reactivity or plasma concentrations of orally administered ticagrelor in patients with ST-segment-elevation myocardial infarction receiving morphine. Clinical Trial Registration URL : http://www.clinicaltrials.gov . Unique identifier: NCT 02942550.


Assuntos
Plaquetas/metabolismo , Morfina/uso terapêutico , Naloxona/análogos & derivados , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Ticagrelor/farmacocinética , Administração Oral , Idoso , Analgésicos Opioides/uso terapêutico , Plaquetas/efeitos dos fármacos , Cateterismo Cardíaco , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Naloxona/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/farmacocinética , Testes de Função Plaquetária , Estudos Prospectivos , Compostos de Amônio Quaternário/administração & dosagem , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Método Simples-Cego , Ticagrelor/administração & dosagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...