Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hip Int ; 22(2): 166-71, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22547383

RESUMO

The design of the Bicontact® stem (BBraun, Aesculap, Tuttlingen, Germany) and the implantation technique have undergone no major alterations in the last 20 years leading, and good clinical results have been reported. The aim of our study was to investigate whether the implant encourages beneficial bone remodelling. Twenty-four patients were included in a prospective dual-energy X-ray absorptiometry (DEXA) study of this stem, after appropriate statistical power analysis. Preoperative and postoperative (1 week, 6 months, and 12 months) clinical and DEXA examinations were performed. The Harris Hip Score increased significantly by 39 points. The strongest decreases in BMD were observed in the greater trochanter region (-11%) and the calcar (-12%). In the second half of the study period the bone mineral density recovered slightly and even returned to baseline values in the lesser trochanter region. Therefore, proximal load transfer and physiological bone remodelling around the Bicontact® stem appeared to be achieved.


Assuntos
Artroplastia de Quadril/efeitos adversos , Densidade Óssea/fisiologia , Cimentação , Prótese de Quadril , Osseointegração/fisiologia , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Estresse Mecânico
2.
Int Orthop ; 36(3): 533-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21935621

RESUMO

PURPOSE: On the basis of positive clinical results with mid- and long-term follow-up using the Mayo short stem, the Metha neck-preserving stem (BBraun, Aesculap, Tuttlingen, Germany) was introduced. The purpose of this study was to validate the implant design by direct acquisition of bone remodelling data from total hip arthroplasty (THA) recipients using dual-energy X-ray absorptiometry (DEXA). METHODS: After power analysis, 25 patients were included in this prospective study. Patients were examined clinically and underwent DEXA examinations preoperatively and postoperatively at one week, six months and one and two years after THA. Gruen zones were adapted to the short stem design (R1-R7). RESULTS: The Harris Hip Score (HHS) increased significantly by 31 points. No stem had to be revised. Bone mineral density (BMD) in the greater trochanter decreased significantly from 0.78 g/cm(2) postoperatively to 0.72 g/cm(2) two years after surgery. Marginal changes were seen in the lateral distal regions (R4-R5). In the minor trochanter region, BMD increased significantly after two years by 12.9%. In the calcar region, BMD exceeded the baseline value by 6.1% two years after implantation. CONCLUSIONS: Stress shielding seems to occur at the greater trochanter due to the vast cross-section of the implant. However, the aim of proximal load transfer of the Metha stem seems to be partially achieved. DEXA analysis revealed a concentrated load distribution on the medial portion of the femur, which is an important region to guarantee long-term implant survival.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Osseointegração , Desenho de Prótese , Absorciometria de Fóton , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Densidade Óssea/fisiologia , Feminino , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Nível de Saúde , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/metabolismo , Osteoartrite do Quadril/cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...