Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
JA Clin Rep ; 10(1): 35, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814496

RESUMO

BACKGROUND: The tricuspid valve is an atrioventricular valve consisting of three lobes. We used the 3D transesophageal echocardiography to visualize position of the pulmonary artery catheter at the tricuspid valve annulus and examined where the catheter passed through at the level of the tricuspid annulus. METHODS: In this prospective and observational study, we monitored the pressure wave on patients undergoing cardiac surgery with the catheter placement by monitoring the pressure waveform for 8 months. We measured the time required for the catheter to pass through the tricuspid and pulmonary valves, respectively. We acquired the 3D image of the tricuspid valve by transesophageal echocardiography and determined the position of the pulmonary artery catheter at the level of the tricuspid annulus. The data were analyzed by Kruskal-Wallis test followed by Mann-Whitney test with Holm multiple comparisons. P < 0.05 was considered significant. RESULTS: Of the 116 cases, the pulmonary artery catheter passed through the tricuspid valve between antero-posterior leaflets in 78 cases (67.2 %), between septal-posterior leaflets in 25 cases (21.6 %), and between antero-septal leaflets in 2 cases (1.7 %) and the center in 11 cases (9.5 %), respectively. The time required for the catheter to pass through the pulmonary valves was significantly different among the catheter positions at the level of the tricuspid annulus. CONCLUSION: The pulmonary artery catheter location at the level of the tricuspid annulus can be identified using 3D transesophageal echocardiography. The location of the catheter significantly affects the pulmonary artery catheter placement time.

2.
Int J Cardiovasc Imaging ; 39(10): 1855-1864, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37341949

RESUMO

In the pediatric and congenital heart disease (CHD) population, tricuspid valve (TV) disorders are complex due to the variable TV morphology, its sophisticated interaction with the right ventricle as well as associated congenital and acquired lesions. While surgery is the standard of care for TV dysfunction in this patient population, transcatheter treatment for bioprosthetic TV dysfunction has been performed successfully. Detailed and accurate anatomic assessment of the abnormal TV is essential in the preoperative/preprocedural planning. Three-dimensional transthoracic and 3D transesophageal echocardiography (3DTEE) provides added value to 2-dimensional imaging in the characterization of the TV to guide therapy and 3DTEE serves as an excellent tool for intraoperative assessment and procedural guidance of transcatheter treatment. Notwithstanding advances in imaging and therapy, the timing and indication for intervention for TV disorders in this population are not well defined. In this manuscript, we aim to review the available literature, provide our institutional experience with 3DTEE, and briefly discuss the perceived challenges and future directions in the assessment, surgical planning, and procedural guidance of (1) congenital TV malformations, (2) acquired TV dysfunction from transvenous pacing leads, or following cardiac surgeries, and (3) bioprosthetic TV dysfunction.

3.
Methodist Debakey Cardiovasc J ; 19(2): 100-102, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910556

RESUMO

An 81-year-old female patient with a history of severe secondary mitral regurgitation, hypertension, and paroxysmal atrial fibrillation was seen by the valve team to determine candidacy for transcatheter edge-to-edge repair of the mitral valve. Two-dimensional biplane imaging showed a transverse basal left ventricle false tendon attached to papillary muscles. The position was concerning for interference during deployment of the mitral clip.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Mitral , Feminino , Humanos , Idoso de 80 Anos ou mais , Ventrículos do Coração/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Ecocardiografia/métodos
4.
J Saudi Heart Assoc ; 34(1): 85-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35891893

RESUMO

Objective: To evaluate the benefit of using three-dimensional transesophageal echocardiography (3DTEE) over conventional two-dimensional transesophageal echocardiography (2DTEE) in evaluation of various morphological features of atrial septal defect (ASD) and patent foramen ovale (PFO) during transcatheter closure. Methods: This is an observational cross sectional study including 115 patients (45 PFO and 70 ASD patients) who underwent 2D/3DTEE guided transcatheter closure from April 2019 to October 2021 in cardiology department, Tanta university hospital. Results: 70 ASD patients were divided into two groups; the pediatric age group (18 patients, mean age 9.05 ± 3.51 years) and the adult group (52 patients, mean age 39.3 ± 10.15 years). ASD morphology was simple in 12.9% and complex in 87.1% of patients, where 3DTEE was superior in the evaluation of posterior, infero posterior rims, fenestrated flimsy rims, aneurysm shape, orientation, and quality of its tissue. Procedural success was defined as complete defect closure with no complications. The procedure was successful in 68 and failed in 2 patients. 45 PFO patients were divided into two groups; the pediatric age group (14 patients, mean age 13.5 ± 3.25 years) and the adult group (31 patients, mean age 35.2 ± 4.5 years). PFO morphology was simple in 22.2% and complex in 77.8% of patients, where 3DTEE was superior in the evaluation of the exact PFO opening from the left atrium, additional fenestrations, aneurysm shape, orientation, and quality of its tissue. The procedure was successful in all patients. Conclusion: 3DTEE guided transcatheter ASD/PFO closure provides an additional value over conventional 2DTEE in assessment of complex ASD/PFO morphology.

5.
J Echocardiogr ; 20(3): 151-158, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35084686

RESUMO

BACKGROUND: Postprocedural mitral stenosis (MS), or increased transmitral mean pressure gradient (TMPG), is one of the limitations of transcatheter edge-to-edge mitral valve repair using MitraClip (Abbott Vascular Inc., Santa Clara, USA); however, the usefulness of three-dimensional transesophageal echocardiography (3D-TEE) for predicting postprocedural MS in functional mitral regurgitation (MR) has not been fully elucidated. METHODS: Eighty-two consecutive functional MR patients who underwent transcatheter mitral valve repair using MitraClip were retrospectively studied. Postprocedural MS was defined as TMPG ≥ 5 mmHg by echocardiography. RESULTS: Ten patients had postprocedural MS, and 3D-TEE showed that patients with postprocedural MS had smaller preprocedural mitral valve orifice area (MVOA), anteroposterior and mediolateral diameter, leaflet area, and annulus area. Receiver operating characteristic analysis showed that leaflet area (area under the curve (AUC) 0.829), annulus area (AUC 0.813), anteroposterior diameter (AUC 0.797) and mediolateral diameter (AUC 0.803) evaluated using 3D-TEE were predictors of postprocedural MS, and their predictive abilities were higher than those of preprocedural MVOA (AUC 0.756) and preprocedural TMPG (AUC 0.716). Adding leaflet area to TMPG and MVOA resulted in higher C-statistics for predicting postprocedural MS (from 0.716 to 0.845 and from 0.756 to 0.853, respectively). CONCLUSIONS: In functional MR patients treated with MitraClip, leaflet area and annulus area evaluated using 3D-TEE had high predictive values for postprocedural MS, and their predictive abilities were higher than those of preprocedural TMPG or MVOA.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
J Cardiothorac Vasc Anesth ; 35(6): 1830-1832, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32737000

RESUMO

A stuck mechanical valve leaflet is a well-known cardiovascular complication; however, a stuck bioprosthetic valve is a rare but potentially fatal complication. Herein a case of stuck bioprosthetic mitral valve caused by a loop of suture, which was detected on intraoperative 3-dimensional (3D) transesophageal echocardiography immediately after cardiopulmonary bypass, is presented. Restricted motion of the 2 leaflets during diastole and incomplete coaptation during systole were observed clearly on 3D imaging. Thus, intraoperative 3D transesophageal echocardiography imaging is useful for detecting such complications immediately after cardiopulmonary bypass.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Domínio AAA , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Suturas/efeitos adversos
8.
Echocardiography ; 37(8): 1308-1311, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32652688

RESUMO

Papillary fibroelastoma (PF) of the right atrium accounts for 2% of nonvalvular cases, and right appendage (RAA) PF was described only once in literature. We present three cases of RAA PF in patients with unrelated symptoms undergoing 3-dimensional transesophageal echocardiographic examination (3D-TEE) scheduled for conventional indications. Key to diagnosis in routine practice resides in systematic examination of the right atrium and RAA in live 3D-TEE imaging with backward and forward navigation of the real-time pyramidal data. A review of literature is provided. Our experience demonstrates that systematic imaging of all cardiac structures with 3D-TEE allows refining PF nosology.


Assuntos
Apêndice Atrial , Fibroelastoma Papilar Cardíaco , Ecocardiografia Tridimensional , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Humanos
9.
Pediatr Cardiol ; 41(7): 1370-1375, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32488509

RESUMO

3D transesophageal echocardiography (3D-TEE) has proven useful and accurate during some operating room (OR), interventional cardiac catheterization (Cath), and electrophysiologic (EP) procedures. The use of 3D-TEE during similar procedures in patients who have undergone Fontan surgery and its additional value have not been previously reported. To determine if live 3D-TEE during procedures post Fontan has added value, 3D-TEEs in 58 post-Fontan patients over a 5-year study period were reviewed. Additional information provided by 3D-TEE (over 2D-TEE) was classified into the following: A: new information which changed/refined the plan and 0: no new important information. Pre- and post-bypass OR 3D-TEEs were counted as one study. A total of 67 3D-TEEs (41 Cath, 13 OR, and 13 EP procedures) were performed. Median age was 14 years (6-39 years). Median weight was 47 kg (21-109 kg). In Cath procedures, only 2/41 (5%) were graded A (R to L atrial level shunt [Fontan leak], n = 1; thrombus in pulmonary artery stump, n = 1). In the OR, 6/13 (46%) were graded A (atrioventricular valvuloplasty, n = 1; neo-aortic valvuloplasty, n = 1; relief of systemic and pulmonary venous outflow obstruction, n = 2 and n = 2; respectively). In EP procedures, 4/13 (31%) were graded A (thrombus, n = 3; mapping for lead placement to assist in multisite pacing for dyssynchrony, n = 1). 3D-TEE of Fontan improved visualization and frequently added value in the OR/EP lab and may be helpful in select catheterization cases. Future studies with a larger sample could build on this data to identify when 3D-TEE will be most useful.


Assuntos
Ecocardiografia Tridimensional/estatística & dados numéricos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Criança , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Trombose/fisiopatologia , Adulto Jovem
10.
Clin Cardiol ; 43(1): 71-77, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31755572

RESUMO

BACKGROUND: Diabetes mellitus (DM) is a common and increasingly prevalent condition in patients with atrial fibrillation (AFib). The left atrium appendage (LAA), a small outpouch from the LA, is the most common location for thrombus formation in patients with AFib. HYPOTHESIS: In this study, we examined LAA remodeling differences between diabetic and nondiabetic patients with AFib. METHODS: This retrospective study analyzed data from 242 subjects subdivided into two subgroups of 122 with DM (diabetic group) and 120 without DM (nondiabetic group). The study group underwent real-time 3-dimensional transesophageal echocardiography (RT3DTEE) for AFib ablation, cardioversion, or LAA device closure. The LAA dimensions were measured using the "Yosefy rotational 3DTEE method." RESULTS: The RT3DTEE analysis revealed that diabetic patients display larger LAA diameters, D1-lengh (2.09 ± 0.50 vs 1.88 ± 0.54 cm, P = .003), D2-width (1.70 ± 0.48 vs 1.55 ± 0.55 cm, P = .024), D3-depth (2.21 ± 0.75 vs 1.99 ± 0.65 cm, P = .017), larger orifice areas (2.8 ± 1.35 and 2.3 ± 1.49 cm2 , P = .004), and diminished orifice flow velocity (37.3 ± 17.6 and 43.7 ± 19.5 cm/sec, P = .008). CONCLUSIONS: Adverse LAA remodeling in DM patients with AFib is characterized by significantly LAA orifice enlargement and reduced orifice flow velocity. Analysis of LAA geometry and hemodynamics may have clinical implications in thrombotic risk assessment and treatment of DM patients with AFib.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial/fisiologia , Cardiomiopatias Diabéticas/fisiopatologia , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cardiomiopatias Diabéticas/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Cardioversão Elétrica , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
11.
JACC Case Rep ; 1(3): 391-393, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34316832

RESUMO

The feasibility of transesophageal 3-dimensional echocardiography to reduce fluoroscopy in pacemaker lead placement has not yet been evaluated. This clinical vignette demonstrates the ability of 3-dimensional echocardiography to visualize intracardiac anatomy and the pacemaker lead and to guide positioning of the lead into the right atrial appendage, thus reducing fluoroscopy by nearly 50%. (Level of Difficulty: Advanced.).

12.
J Cardiothorac Vasc Anesth ; 32(1): 344-351, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29128482

RESUMO

OBJECTIVE: The aim of this study was to test both in humans and using finite element (FE) aortic valve (AV) models whether the coaptation surface area (CoapSA) correlates with aortic insufficiency (AI) severity due to dilated aortic roots to determine the validity and utility of 3-dimensional transesophageal echocardiographic-measured CoapSA. DESIGN: Two-pronged, clinical and computational approach. SETTING: Single university hospital. PARTICIPANTS: The study comprised 10 patients with known AI and 98 FE simulations of increasingly dilated human aortic roots. INTERVENTIONS: The CoapSA was calculated using intraoperative 3-dimensional transesophageal echocardiography data of patients with isolated AI and compared with established quantifiers of AI. In addition, the CoapSA and effective regurgitant orifice area (EROA) were determined using FE simulations. MEASUREMENTS AND MAIN RESULTS: In the 10 AI patients, regurgitant fraction (RF) increased with EROA (R2 = 0.77, p = 0.0008); CoapSA decreased with RF (R2 = 0.72, p = 0.0020); CoapSA decreased with EROA (R2 = 0.71, p = 0.0021); and normalized CoapSA (CoapSA / [Ventriculo-Aortic Junction × Sinotubular Junction]) decreased with EROA (R2 = 0.60, p = 0.0088). In the 98 FE simulations, normalized CoapSA decreased with EROA (R2 = 0.50, p = 0.0001). CONCLUSIONS: In both human and FE AV models, CoapSA was observed to be inversely correlated with AI severity, EROA, and RF, thereby supporting the validity and utility of 3D TEE-measured CoapSA. A clinical implication is the expectation that high values of CoapSA, measured intraoperatively after AV repairs, would correlate with better long-term outcomes of those repairs.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Simulação por Computador , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Monitorização Intraoperatória/métodos , Índice de Gravidade de Doença , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino
13.
Cardiovasc Ultrasound ; 14(1): 36, 2016 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-27553013

RESUMO

BACKGROUND: Not all echo laboratories have the capability of measuring direct online 3D images, but do have the capability of turning 3D images into 2D ones "online" for bedside measurements. Thus, we hypothesized that a simple and rapid rotation of the sagittal view (green box, x-plane) that shows all needed left atrial appendage (LAA) number of lobes, orifice area, maximal and minimal diameters and depth parameters on the 3D transesophageal echocardiography (3DTEE) image and LAA measurements after turning the images into 2D (Rotational 3DTEE/"Yosefy Rotation") is as accurate as the direct measurement on real-time-3D image (RT3DTEE). METHODS: We prospectively studied 41 consecutive patients who underwent a routine TEE exam, using QLAB 10 Application on EPIQ7 and IE33 3D-Echo machine (BORTHEL Phillips) between 01/2013 and 12/2015. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between RT3DTEE and Rotational 3DTEE versus CT. RESULTS: Rotational 3DTEE measurements of LAA were not statistically different from RT3DTEE and from CT regarding: number of lobes (1.6 ± 0.7, 1.6 ± 0.6, and 1.4 ± 0.6, respectively, p = NS for all); internal area of orifice (3.1 ± 0.6, 3.0 ± 0.7, and 3.3 ± 1.5 cm(2), respectively, p = NS for all); maximal LAA diameter (24.8 ± 4.5, 24.6 ± 5.0, and 24.9 ± 5.8 mm, respectively, p = NS for all); minimal LAA diameter (16.4 ± 3.4, 16.7 ± 3.3, and 17.0 ± 4.4 mm, respectively, p = NS for all), and LAA depth (20.0 ± 2.1, 19.8 ± 2.2, and 21.7 ± 6.9 mm, respectively, p = NS for all). CONCLUSION: Rotational 3DTEE method for assessing LAA is a simple, rapid and feasible method that has accuracy similar to that of RT3DTEE and CT. Thus, rotational 3DTEE ("Yosefy rotation") may facilitate LAA closure procedure by choosing the appropriate device size.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
Interv Cardiol Clin ; 4(1): 23-37, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28582120

RESUMO

Degenerative aortic stenosis is the most common cause of valvular heart disease in Western nations. Transcatheter aortic valve replacement (TAVR) is an alternative therapy for inoperable or high-risk patients with symptomatic severe aortic stenosis. Three-dimensional imaging techniques provide multiplanar imaging, allowing precise measurements of the noncircular aortic annulus and complex anatomy of the aortic root. These measurements influence patient eligibility, allow adequate prosthesis sizing, and determine the success of implantation and likelihood of complications. This review compares imaging modalities and addresses their strengths and weaknesses to assess the aortic annulus and other aortic root structures.

15.
Methodist Debakey Cardiovasc J ; 10(2): 68-76, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25114757

RESUMO

Cardiac catheterization procedures for patients with congenital and structural heart disease are becoming more complex. New imaging strategies involving integration of 3-dimensional images from rotational angiography, magnetic resonance imaging (MRI), computerized tomography (CT), and transesophageal echocardiography (TEE) are employed to facilitate these procedures. We discuss the current use of these new 3D imaging technologies and their advantages and challenges when used to guide complex diagnostic and interventional catheterization procedures in patients with congenital heart disease.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Multimodal/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Angiografia Coronária , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Adulto Jovem
16.
Int J Cardiol ; 176(3): 878-84, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25147061

RESUMO

INTRODUCTION: In functional mitral regurgitation (FMR), effective regurgitant orifice area (EROA) displays a dynamic pattern. The impact of dynamic changes of annulus dysfunction and leaflets tenting on phasic EROA was explored with real-time three-dimensional transesophageal echocardiography (RT3D-TEE). METHODS: RT3D-TEE was performed in 52 FMR patients and 30 controls. Mitral annulus dimensions and leaflets tenting were measured throughout systole (TomTec, Germany). Phasic EROA was measured by proximal isovelocity surface area (PISA) method. RESULTS: Mitral annulus had the minimal area and an oval shape with saddle configuration during early systole in controls, which enlarged and became round and flattened towards mid and late systole (P<0.05). In contrast, annulus in FMR was significantly larger, rounder and flatter (P<0.001), which further dilated and became more flattened at late systole (P<0.05 vs control). Leaflet tenting height in FMR decreased in mid systole and remains unchanged towards late systole. The leaflet tenting volume peaked at early and late systole with a mid-systolic trough in both FMR and controls. But tenting volume of patients with FMR was significantly larger than that of controls (all P<0.001 vs control in whole systole). Further analysis demonstrated that early tenting volume (ß value=0.053, P<0.05) was a predictor of early EROA, whereas late tenting volume (ß value=0.031, P<0.05) and late annular displacement velocity were predictors of late EROA. CONCLUSIONS: The early and late peak EROAs of FMR was primarily contributed by tenting volume at early systole and late systole respectively. These findings would be of value to consider in interventions aimed at reducing the severity of FMR.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/tendências , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
JACC Cardiovasc Imaging ; 7(3): 292-308, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24651102

RESUMO

Guidance of catheter-based procedures is performed using fluoroscopy and 2-dimensional transesophageal echocardiography (TEE). Both of these imaging modalities have significant limitations. Because of its 3-dimensional (3D) nature, 3D TEE allows visualizing the entire scenario in which catheter-based procedures take place (including long segments of catheters, tips, and the devices) in a single 3D view. Despite these undeniable advantages, 3D TEE has not yet gained wide acceptance among most interventional cardiologists and echocardiographists. One reason for this reluctance is probably the absence of standardized approaches for obtaining 3D perspectives that provide the most comprehensive information for any single step of any specific procedure. Therefore, the purpose of this review is to describe what we believe to be the most useful 3D perspectives in the following catheter-based percutaneous interventions: transseptal puncture; patent foramen ovale/atrial septal defect closure; left atrial appendage occlusion; mitral valve repair; and closure of paravalvular leaks.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Cardiopatias/terapia , Ultrassonografia de Intervenção/métodos , Cardiopatias/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Punções , Resultado do Tratamento
18.
J Ultrasound Med ; 33(2): 297-306, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24449733

RESUMO

OBJECTIVES: Transesophageal echocardiography has become a standard tool for evaluating left ventricular function during cardiac surgery. However, the image quality varies widely between patients and examinations. The aim of this study was to investigate the influence of the image quality on 5 commonly used 2-dimensional methods. METHODS: Transesophageal real-time 3-dimensional echocardiography (3DE) served as a reference. Left ventricular function was evaluated in 63 patients with sufficient real-time 3DE image quality. The image quality was rated using the ratio of the visualized border divided by the total endocardial border. These ratings were used to generate groups of poor (0%-40%), fair (41%-70%), and good (71%-100%) image quality. The ejection fraction (EF), end-diastolic volume, and end-systolic volume were analyzed by the Simpson method of disks (biplane and monoplane), eyeball method, Teichholz method, and speckle-tracking method. Furthermore, the fractional area change was determined. Each correlation with real-time 3DE was evaluated. RESULTS: Correlations of the EF and volumes, respectively, as determined by long-axis view methods increased with improving image quality: the Simpson biplane method was found to be the most accurate method, with good image quality for the EF (r = 0.946) and volumes (end-diastolic volume, r = 0.962; end-systolic volume, r = 0.989). Correlations of the EF and fractional area change by short-axis view methods decreased with improving image quality, with the Teichholz EF found to be most accurate with poor (r = 0.928) in contrast to good (r = 0.699) image quality. CONCLUSIONS: With good image quality, the Simpson biplane method is the most accurate 2-dimensional method for assessing the left ventricular EF. Short-axis view methods, especially the Teichholz method yield better correlations with poor image quality. The eyeball method was unaffected by image quality.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/cirurgia , Sistemas Computacionais , Ecocardiografia/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Resultado do Tratamento
19.
Methodist Debakey Cardiovasc J ; 10(3): 172-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25574345

RESUMO

Interventional echocardiography is a rapidly evolving field requiring imaging expertise. An increasing number of structural heart interventions now require real-time imaging guidance for device placement and immediate functional evaluation. Continuous 2- and 3-dimensional transesophageal echocardiography are now required by many heart teams during complex structural interventions, including percutaneous closure of atrial septal defects, left atrial appendage occlusion, transcatheter aortic valve replacement (TAVR), transcatheter repair of paravalvular regurgitation, and percutaneous mitral valve repair. In this review, we describe the role of echocardiography during the initial structural evaluation, throughout the device placement procedure, and for the assessment of acute device function and complications.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Cardiopatias/terapia , Implante de Prótese de Valva Cardíaca/métodos , Ultrassonografia de Intervenção/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/terapia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Valor Preditivo dos Testes , Dispositivo para Oclusão Septal , Resultado do Tratamento
20.
J Cardiothorac Vasc Anesth ; 27(4): 639-46, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23725682

RESUMO

OBJECTIVE: To demonstrate the clinical feasibility of accurately measuring tricuspid annular area by 3-dimensional (3D) transesophageal echocardiography (TEE) and to assess the geometric differences based on the presence of tricuspid regurgitation (TR). Also, the shape of the tricuspid annulus was compared with previous descriptions in the literature. DESIGN: Prospective. SETTING: Tertiary care university hospital. INTERVENTIONS: Three-dimensional TEE. PARTICIPANTS: Patients undergoing cardiac surgery. MEASUREMENTS AND MAIN RESULTS: Volumetric data sets from 20 patients were acquired by 3D TEE and prospectively analyzed. Comparisons in annular geometry were made between groups based on the presence of TR. The QLab (Philips Medical Systems, Andover, MA) software package was used to calculate tricuspid annular area by both linear elliptical dimensions and planimetry. Further analyses were performed in the 4D Cardio-View (TomTec Corporation GmBH, Munich, Germany) and MATLAB (Natick, MA) software environments to accurately assess annular shape. It was found that patients with greater TR had an eccentrically dilated annulus with a larger annular area. Also, the area as measured by the linear ellipse method was overestimated as compared to the planimetry method. Furthermore, the irregular saddle-shaped geometry of the tricuspid annulus was confirmed through the mathematic model developed by the authors. CONCLUSIONS: Three-dimensional TEE can be used to measure the tricuspid annular area in a clinically feasible fashion, with an eccentric dilation seen in patients with TR. The tricuspid annulus shape is complex, with annular high and low points, and annular area calculation based on linear measurements significantly overestimates 3D planimetered area.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Idoso , Anestesia Geral , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Quadridimensional , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Estudos Prospectivos , Software , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...