Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
Spine Surg Relat Res ; 8(3): 297-305, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38868793

RESUMO

Introduction: To analyze the reliability of the newly developed patient-specific Screw Guide Template (SGT) system as an intraoperative navigation device for spinal screw insertion. Methods: We attempted to place 428 screws for 51 patients. The accuracy of the screw track was assessed by deviation of the screw axis from the preplanned trajectory on postoperative CT. The safety of the screw insertion was evaluated by the bone breach of the screw. The bone diameter available for screw trajectory (DAST) was measured, and the relations to the bone breach were analyzed. Results: In the inserted screws, 98.4% were defined as accurate, and 94.6% were contained in the target bone. In the cervical spine, the screw deviation between breaching (0.57 mm) and contained screws (0.43 mm) did not significantly differ, whereas DAST for breaching screws (3.62 mm) was significantly smaller than contained screws (5.33 mm) (p<0.001). Cervical screws with ≥4.0 mm DAST showed a significantly lower incidence of bone breach (0.4%) than ≤3.9 mm DAST (28.3%) (p<0.001). In the thoracic spine, screw deviation and DAST had significant differences between breaching (1.54 mm, 4.41 mm) and contained (0.75 mm, 6.07 mm) (p<0.001). The incidence of the breach was significantly lower in thoracic screws with ≥5.0 mm (1.9%) than ≤4.9 (21.9%) DAST (p<0.001). Conclusions: This study demonstrated that our SGT system could support precise screw insertion for 98.4% accuracy and 94.6% safety. DAST was recommended to be ≥4.0 and ≥5.0 mm in the cervical and thoracic spines for safe screw insertion.

2.
Pharmaceutics ; 16(6)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931904

RESUMO

The aim of this study was to fabricate mini-tablets of polyhedrons containing theophylline using a fused deposition modeling (FDM) 3D printer, and to evaluate the correlation between release kinetics models and their geometric shapes. The filaments containing theophylline, hydroxypropyl cellulose (HPC), and EUDRAGIT RS PO (EU) could be obtained with a consistent thickness through pre-drying before hot melt extrusion (HME). Mini-tablets of polyhedrons ranging from tetrahedron to icosahedron were 3D-printed using the same formulation of the filament, ensuring equal volumes. The release kinetics models derived from dissolution tests of the polyhedrons, along with calculations for various physical parameters (edge, SA: surface area, SA/W: surface area/weight, SA/V: surface area/volume), revealed that the correlation between the Higuchi model and the SA/V was the highest (R2 = 0.995). It was confirmed that using 3D- printing for the development of personalized or pediatric drug products allows for the adjustment of drug dosage by modifying the size or shape of the drug while maintaining or controlling the same release profile.

3.
J Pharm Bioallied Sci ; 16(Suppl 2): S1431-S1432, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38882783

RESUMO

The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. Three different 3D printers were included in this study (Formlabs Form 2 3D printer; Moonray S100 printer (Sprintray, Los Angeles, CA, USA); Eden500V Stratasys 3D Printers were used to prepare orthodontic aligners with dental. The central incisors of each aligner were cut, prepared, and evaluated in terms of Martens-Hardness (HM), indentation-modulus (EIT), and elastic-index (ηIT) as per ISO14577-1:2002. Post hoc pairwise comparisons indicated no significant difference in Martens-Hardness (HM), indentation-modulus (EIT), and elastic-index (ηIT) properties in any group. Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.

4.
J Appl Gerontol ; : 7334648241263234, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38901837

RESUMO

Reminiscence has been found to be an effective therapy for older adults and researchers and practitioners have identified a range of benefits, from cognitive stimulation to the reconciliation of past experiences. In this qualitative study, the authors explore the experiences of older adults engaged in a technology-enhanced form of reminiscence therapy (RT) using three-dimensional (3D) printed objects from peoples' past. Content analysis of individual interviews with seven participants (n = 7) revealed three themes: (1) positive experiences with the RT intervention; (2) reflections on the use of 3D printed objects; and (3) the development of relationships between participants and researchers. These findings suggest that RT using 3D printed objects can be effective, but only if objects are accurate and if it suits participants' personalities. Researchers and practitioners may find that the use of 3D printed objects can enhance their RT interventions and thereby enrich the lives of older adults.

5.
J Oral Biosci ; 66(2): 339-348, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38750954

RESUMO

OBJECTIVES: The development of bio-three-dimensional (bio-3D) printers has led to significant advances in regenerative medicine. Three-dimensional constructs, including spheroids, are maintained by extracellular matrix proteins secreted by cells so that the cells can be cultured in conditions closer to the physiological environment. This study aimed to create a useful 3D construct as a model of the dentin-pulp complex. METHODS: We examined the expression patterns of extracellular matrix proteins and cell proliferation areas in a 3D construct created using O9-1 cells derived from cranial neural crest cells of mice. The 3D construct was created by sticking the spheroid cultures onto a needle array using a bio-3D printer. RESULTS: Cell proliferation areas along with characteristic expression of tenascin C and DMP1 were evaluated. The expression of tenascin C and DMP1 was significantly enhanced in the spheroids compared to that in two-dimensional cultures. Moreover, cell proliferation regions and tenascin C expression were confirmed in the outer layer of spheroids in the embryonic stem cell medium, with insignificant DMP1 expression being observed. Interestingly, in a 3D construct cultured in calcification-induction medium, DMP1 expression was promoted, and DMP1-positive cells existed in the outermost layer without overlapping with tenascin C expression. CONCLUSIONS: The extracellular matrix proteins, tenascin C and DMP1, were expressed in a polarized manner in spheroids and 3D constructs, similar to the findings in the dental papilla. Therefore, these 3D constructs show potential as artificial models for studying odontogenesis.


Assuntos
Proliferação de Células , Proteínas da Matriz Extracelular , Crista Neural , Impressão Tridimensional , Tenascina , Crista Neural/citologia , Crista Neural/metabolismo , Animais , Camundongos , Tenascina/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Linhagem Celular , Esferoides Celulares/citologia , Esferoides Celulares/metabolismo , Engenharia Tecidual/métodos
6.
Food Chem ; 454: 139699, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38797101

RESUMO

The production process of fermented black wheat steamed bread is closely related to the overall quality and nutritional content. In this study, we investigated the accuracy, product texture profile and antioxidant activity of fermented black wheat steamed bread samples produced by piston and spiral three-dimensional (3D) printers. The steaming process generally increased the total phenolic content and flavonoid content of the samples. The spiral 3D printer obtained samples with higher accuracy, total phenolic content up to 1960.43 Mg GAE/kg, and higher cellular antioxidant activity (CAA) content. The samples printed by the piston 3D printer showed higher total flavonoid content (575.75 Mg QE/kg), 2, 2'-azobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) values and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) values. This study shows that antioxidant-rich health foods can be prepared using 3D printed black wheat flour. The choice of 3D printing method affects the overall quality and nutritional content of the final product.


Assuntos
Vapor , Impressão Tridimensional , Antioxidantes/química , Antioxidantes/farmacologia , Fenóis/química , Fenóis/farmacologia , Células Hep G2 , Humanos , Proliferação de Células/efeitos dos fármacos
7.
Cureus ; 16(4): e59228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38807807

RESUMO

Aim Balanced function of the orofacial muscles is important for normal occlusion and dentition; however, patients with malocclusion often present with myofunctional disorder (MFD). Myofunctional therapy (MFT) has received much attention as a method for reducing MFD. Moreover, prefabricated functional appliances (PFAs) have been developed as a method to eliminate abnormal muscle pressure and guide the tongue into the correct position. However, PFAs have disadvantages, such as poor intraoral retention, limited usage time due to discomfort and poor patient compliance, and changes in the axis of the mandibular anterior teeth. Therefore, this study aimed to develop a new custom-made splint-type orthodontic appliance with CAD/CAM technology. Moreover, we evaluated the characteristics of the appliance and conducted functional tests to determine the effects of the appliance on the orofacial muscles and the discomfort associated with its use. Materials and methods Twenty-five volunteers (nine females and 16 males; mean age 28.4 ± 3.4 years) with normal swallowing function were included in the study. Lip-closing strength (LCS), electromyogram during swallowing, oxygen saturation, and pulse rate were measured and compared when the appliance was not worn and when it was worn. In addition, tongue habits were evaluated, and the maximum tongue pressure was measured when the appliance was not worn. The subjects were asked to answer a questionnaire using a numerical rating scale (NRS) regarding discomfort when wearing the appliance. The evaluation items were swallowing difficulty, speaking difficulty, and breathlessness, which were rated on an 11-point scale ranging from 0 to 10. Statistical tests were conducted using IBM SPSS version 28.0.1 (IBM, Armonk, NY, USA) with the Shapiro-Wilk and Levene's test, followed by the Wilcoxon signed rank sum test. The significance level was set at α = 0.05. The measurement error for each measurement item was evaluated using an intraclass correlation coefficient. Results A new custom-made splint-type orthodontic appliance was fabricated for each subject. The fit and retention of the appliance in the mouth were good when fitted, and a comparison of the functional test measurements of 25 subjects with and without the appliance showed that the LCS decreased significantly (p<0.05) before and after wearing the appliance. However, no statistically significant differences were found for the other items. The Mann-Whitney U test regarding the effects of sex, previous orthodontic treatment, or MFT, and oral habits did not statistically significantly influence the effects of wearing the device. In the NRS results, "difficulty swallowing" was observed in half of the subjects, "difficulty breathing" was rarely observed, and "difficulty speaking" was observed in all subjects. Conclusions A novel custom-made splint-type orthodontic appliance was designed and fabricated using digital workflow and 3D printing technology. This appliance was designed to correct oral habits and was made from a new material classified as a class II medical appliance according to the international harmonized classification.

8.
Sci Total Environ ; 931: 173003, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38710394

RESUMO

This study investigated particle and volatile organic compound (VOC) emission rates (ER) from 3D pens, which are increasingly popular in children's toys. Nine filaments and two 3D pens were evaluated using a flow tunnel, a scanning mobility particle sizer, a proton-transfer-reaction time-of-flight mass spectrometer for particles, and a thermal desorption-gas chromatography-mass spectrometer for VOCs. Results showed that the ERs varied with the pen type, filament, and brand. The particle ER was highest for acrylonitrile butadiene styrene (ABS), followed by polylactic acid (PLA) and polycaprolactone (PCL). Notably, ERs of 83 % and 33 % of ABS and PLA filaments exceeded the maximum allowable particle ER (MAER; 5 × 109 particles/min) for 3D printers but were lower than the VOC MAER (173 µg/min in the office). Different filaments emitted diverse VOCs; ABS emitted styrene and benzene, PLA emitted lactide, and PCL emitted phenol. While particle ERs from 3D pens were comparable to those from printers, the total VOC ERs from 3D pens were slightly lower. Caution is warranted when using 3D pens because of potential health risks, especially their prolonged use, proximity to the breathing zone, and usage by children. This study highlights the need for considering particles and VOCs when assessing the safety of 3D pens, emphasizing awareness of potential hazards, particularly in child-oriented settings.


Assuntos
Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Monitoramento Ambiental/métodos , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Poliésteres/análise , Impressão Tridimensional , Material Particulado/análise
9.
Diabetes Metab Syndr ; 18(4): 103002, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38615569

RESUMO

AIMS: Despite numerous studies covering the various features of three-dimensional printing (3D printing) technology, and its applications in food science and disease treatment, no study has yet been conducted to investigate applying 3D printing in diabetes. Therefore, the present study centers on the utilization and impact of 3D printing technology in relation to the nutritional, pharmaceutical, and medicinal facets of diabetes management. It highlights the latest advancements, and challenges in this field. METHODS: In this review, the articles focusing on the application and effect of 3D printing technology on medical, pharmaceutical, and nutritional aspects of diabetes management were collected from different databases. RESULT: High precision of 3D printing in the placement of cells led to accurate anatomic control, and the possibility of bio-printing pancreas and ß-cells. Transdermal drug delivery via 3D-printed microneedle (MN) patches was beneficial for the management of diabetes disease. 3D printing supported personalized medicine for Diabetes Mellitus (DM). For instance, it made it possible for pharmaceutical companies to manufacture unique doses of medications for every diabetic patient. Moreover, 3D printing allowed the food industry to produce high-fiber and sugar-free products for the individuals with DM. CONCLUSIONS: In summary, applying 3D printing technology for diabetes management is in its early stages, and needs to be matured and developed to be safely used for humans. However, its rapid progress in recent years showed a bright future for the treatment of diabetes.


Assuntos
Diabetes Mellitus , Impressão Tridimensional , Humanos , Diabetes Mellitus/terapia , Sistemas de Liberação de Medicamentos , Hipoglicemiantes/administração & dosagem , Medicina de Precisão/métodos , Pâncreas/citologia , Células Secretoras de Insulina/citologia
10.
J Tissue Eng ; 15: 20417314241244997, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617462

RESUMO

The study focused on the effects of a triply periodic minimal surface (TPMS) scaffolds, varying in porosity, on the repair of mandibular defects in New Zealand white rabbits. Four TPMS configurations (40%, 50%, 60%, and 70% porosity) were fabricated with ß-tricalcium phosphate bioceramic via additive manufacturing. Scaffold properties were assessed through scanning electron microscopy and mechanical testing. For proliferation and adhesion assays, mouse bone marrow stem cells (BMSCs) were cultured on these scaffolds. In vivo, the scaffolds were implanted into rabbit mandibular defects for 2 months. Histological staining evaluated osteogenic potential. Moreover, RNA-sequencing analysis and RT-qPCR revealed the significant involvement of angiogenesis-related factors and Hippo signaling pathway in influencing BMSCs behavior. Notably, the 70% porosity TPMS scaffold exhibited optimal compressive strength, superior cell proliferation, adhesion, and significantly enhanced osteogenesis and angiogenesis. These findings underscore the substantial potential of 70% porosity TPMS scaffolds in effectively promoting bone regeneration within mandibular defects.

11.
Biomimetics (Basel) ; 9(4)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667251

RESUMO

The use of metamaterials is a good alternative when looking for structures that can withstand compression forces without increasing their weight. In this sense, using nature as a reference can be an appropriate option to design this type of material. Therefore, in this work, a comparative study of a selection of eight representative models of a wide variety of existing solutions, both bioinspired and proposed by various researchers, is presented. These models have been manufactured using stereolithography (SLA) printing, which allows complex geometries to be obtained in a simple way that would be more complicated to achieve by other procedures. Additionally, the manufacturing cost of each model has been determined. The compression tests of the different models have made it possible to evaluate the breaking force and its corresponding deformation. Likewise, a finite element analysis of the manufactured models has been carried out to simulate their behavior under compression, achieving results very similar to those obtained in the experimental tests. In this way, it has been concluded that, among the three-dimensional patterns, the structure called "3D auxetic" is the one that supports the greatest breaking force due to the topographic characteristics of its bar structure. Similarly, among the two-dimensional patterns, the structure called "Auxetic 1", with a topography based on curves, is capable of supporting the greatest deformation in the compression direction before breaking. Moreover, the highest resistance-force-to-cost ratio has been obtained with a "3D auxetic" structure.

12.
Adv Sci (Weinh) ; 11(21): e2308806, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38528800

RESUMO

One of the most important public health concerns is the increase in antibiotic-resistant pathogens and corresponding treatment of associated infections. Addressing this challenge requires more efficient use of antibiotics, achievable by the use of evidence-based, effective antibiotics identified by antibiotic susceptibility testing (AST). However, the current standard method of phenotypic AST used for this purpose requires 48 h or more from sample collection to result. Until results are available, broad-spectrum antibiotics are used to avoid delaying treatment. The turnaround time must therefore be shortened in order for the results to be available before the second administration of antibiotics. The phenotypic electrochemical AST method presented here identifies effective antibiotics within 5-10 h after sampling. Spiked serum samples, including polymicrobial samples, with clinically relevant pathogens and respective concentrations commonly found in bloodstream infections (Escherichia coli, Staphylococcus aureus, Klebsiella pneumoniae, and Pseudomonas aeruginosa) are used. Direct loading of the test with diluted serum eliminates the need for a pre-culture, as required by existing methods. Furthermore, by combining several electrochemical measurement procedures with computational analysis, allowing the method to be used both online and offline, the AST achieves a sensitivity of 94.44% and a specificity of 95.83% considering each replicate individually.


Assuntos
Antibacterianos , Testes de Sensibilidade Microbiana , Fenótipo , Impressão Tridimensional , Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana/métodos , Humanos , Staphylococcus aureus/efeitos dos fármacos , Klebsiella pneumoniae/efeitos dos fármacos , Pseudomonas aeruginosa/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos
13.
Micromachines (Basel) ; 15(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38542612

RESUMO

New rapid, reliable, and cost-effective alternative systems are needed for the rapid diagnosis of Streptococcus pyogenes. The aim of this study was to fabricate a microfluidic test device to detect Streptococcus pyogenes by combining the Loop-mediated isothermal amplification method via a 3D printer. Microfluidic test devices were designed in CATIA V5 Release 16 software, and data were directly transferred to a 3D printer and produced using the FDM method with biocompatible PLA filament. The S. pyogenes ATCC 19615 and different ATCC strains was used. Following identification by classical culture methods, a 0.5 McFarland suspension was prepared from the colonies, and DNA isolation was performed from this liquid by a boiling method. S. pyogenes specific speB gene was used to desing LAMP primer sets in PrimerExplorer V5 software and tested on a microfluidic device. LAMP reactions were performed on microfluidic device and on a microcentrifuge tube separately. Both results were analyzed using the culture method as the standard method to diagnostic values. Melting curve analysis of the amplicons of the LAMP reactions performed on a LightCycler 480 system to detect amplification. Among the 50 positive and 100 negative samples, only four samples were found to be false negative by LAMP reaction in a microcentrifuge tube, while eight samples were found to be false negative by LAMP reaction on a microfluidic device. Six samples were found to be false positive by the LAMP reaction in the microcentrifuge tube, while ten samples were found to be false positive by the LAMP reaction on a microfluidic chip. The sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP reactions performed in the microcentrifuge tube and on the microfluidic device were 92-84%, 94-90%, 88.46-80.77%, and 95.92-91.84%, respectively. The limit of detection (LOD) was found to be the same as 1.5 × 102 CFU/mL and the limit of quantification (LOQ) values of the LAMP reactions were performed on the microcentrifuge tube and on the microfluidic device were 2.46 × 102-7.4 × 102 CFU/mL, respectively. Cohen's kappa (κ) values of the LAMP reactions were performed on the microcentrifuge tube and on the microfluidic device were 0.620-0.705, respectively. In conclusion, our data showed that the LAMP method can be combined with microfluidic test device to detect S. pyogenes, this microfluidic device can be manufactured using 3D printers and results are close to gold standard methods. These devices can be combined with LAMP reactions to detect different pathogens where resources are limited and rapid results are required.

14.
J Prosthodont ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38513226

RESUMO

This technique presents a new fabrication workflow for a three-dimensional (3D) printed custom tray, which duplicates the morphology of the treatment denture for maxillofacial prostheses using an intraoral scanner, computer-aided design (CAD) software, and a 3D printer. A 70-year-old man underwent reconstruction of segmental mandibulectomy for mandibular osteoblastoma, followed by implant placement and secondary surgery. During the surgical treatment, a treatment denture was fabricated to restore oral function and determine the morphology of the definitive denture. To create the definitive denture with the same morphology as the treatment denture a custom tray was fabricated with the denture morphology after chairside adjustments. The oral cavity was scanned using an intraoral scanner, and the data acquired were imported into general-purpose CAD software, adjusted, and imported into a 3D printer to produce the custom tray. This was fitted into the patient's mouth without any issues, and closed tray impressions were made with impression caps for the locator attachments on the implant body. The morphology of the treatment denture was replicated in the definitive denture by making a silicon impression of the cameo surface at the fabrication of the cast after impression making. In this technique, the morphology of the treatment denture was transferred accurately to the definitive implant partial denture by leveraging existing digital technology. This method represents a practical approach for partial denture fabrication, including maxillofacial defects with complex denture configurations.

15.
Childs Nerv Syst ; 40(6): 1881-1888, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38427108

RESUMO

PURPOSE: 3D printing technologies have become an integral part of modern life, and the most routinely used materials in reconstructive surgery in children are biodegradable materials. The combination of these two technologies opens up new possibilities for the application of innovative methods in neurosurgery and a patient-centered approach in medical care. The aim of the study was to determine whether a physician without specialized programming and printing skills could independently create materials in a clinical setting for the treatment of patients. METHODS: We conducted a preclinical study on 15 male Balb-C mice. Cylindrical materials made of polylactic acid (PLA) plastic were 3D printed. Sterilization of the obtained material was performed using a cold plasma sterilizer with hydrogen peroxide vapor and its plasma. The sterile material was implanted subcutaneously into the mice for 30 days, followed by histological examination. Using open-source software for modeling and printing, plates and screws made of PLA plastic were manufactured. The produced components were tested in the biomedical laboratory of the institute. RESULTS: The histological material showed that no inflammatory changes were observed at the implantation site during the entire observation period. The cellular composition is mainly represented by macrophages and fibroblasts. There was a gradual resolution of the material and its replacement by native tissues. Research conducted to assess the effectiveness of material sterilization in a cold plasma sterilizer demonstrated its high bactericidal efficiency. CONCLUSION: The method we developed for obtaining biodegradable plates and fixation elements on a 3D printer is easy to use and has demonstrated safety in a preclinical study on an animal model.


Assuntos
Camundongos Endogâmicos BALB C , Impressão Tridimensional , Animais , Masculino , Camundongos , Procedimentos Neurocirúrgicos/métodos , Poliésteres , Implantes Absorvíveis , Materiais Biocompatíveis , Humanos
16.
J Toxicol Environ Health A ; 87(8): 325-341, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38314584

RESUMO

During fused filament fabrication (FFF) 3D printing with polycarbonate (PC) filament, a release of ultrafine particles (UFPs) and volatile organic compounds (VOCs) occurs. This study aimed to determine PC filament printing emission-induced toxicity in rats via whole-body inhalation exposure. Male Sprague Dawley rats were exposed to a single concentration (0.529 mg/m3, 40 nm mean diameter) of the 3D PC filament emissions in a time-course via whole body inhalation for 1, 4, 8, 15, and 30 days (4 hr/day, 4 days/week), and sacrificed 24 hr after the last exposure. Following exposures, rats were assessed for pulmonary and systemic responses. To determine pulmonary injury, total protein and lactate dehydrogenase (LDH) activity, surfactant proteins A and D, total as well as lavage fluid differential cells in bronchoalveolar lavage fluid (BALF) were examined, as well as histopathological analysis of lung and nasal passages was performed. To determine systemic injury, hematological differentials, and blood biomarkers of muscle, metabolic, renal, and hepatic functions were also measured. Results showed that inhalation exposure induced no marked pulmonary or systemic toxicity in rats. In conclusion, inhalation exposure of rats to a low concentration of PC filament emissions produced no significant pulmonary or systemic toxicity.


Assuntos
Exposição por Inalação , Pulmão , Cimento de Policarboxilato , Ratos , Masculino , Animais , Ratos Sprague-Dawley , Pulmão/metabolismo , Líquido da Lavagem Broncoalveolar
17.
J Biomater Appl ; 38(9): 975-988, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38423069

RESUMO

Cranioplasty involves the surgical reconstruction of cranial defects arising as a result of various factors, including decompressive craniectomy, cranial malformations, and brain injury due to road traffic accidents. Most of the modern decompressive craniectomies (DC) warrant a future cranioplasty surgery within 6-36 months. The conventional process of capturing the defect impression and polymethyl methacrylate (PMMA) flap fabrication results in a misfit or misalignment at the site of implantation. Equally, the intra-operative graft preparation is arduous and can result in a longer surgical time, which may compromise the functional and aesthetic outcomes. As part of a multicentric pilot clinical study, we recently conducted a cohort study on ten human subjects during 2019-2022, following the human ethics committee approvals from the participating institutes. In the current study, an important aspect of measuring the extent of bone remodelling during the time gap between decompressive craniectomy and cranioplasty was successfully evaluated. The sterilised PMMA bone flaps were implanted at the defect area during the cranioplasty surgery using titanium mini plates and screws. The mean surgery time was 90 ± 20 min, comparable to the other clinical studies on cranioplasty. No signs of intra-operative and post-operative complications, such as cerebrospinal fluid leakage, hematoma, or local and systemic infection, were clinically recorded. Importantly, aesthetic outcomes were excellent for all the patients, except in a few clinical cases, wherein the PMMA bone flap was to be carefully customized due to the remodelling of the native skull bone. The extent of physiological remodelling was evaluated by superimposing the pre-operative and post-operative CT scan data after converting the defect morphology into a 3D model. This study further establishes the safety and efficacy of a technologically better approach to fabricate patient-specific acrylic bone flaps with improved surgical outcomes. More importantly, the study outcome further demonstrates the strategy to address bone remodelling during the patient-specific implant design.


Assuntos
Craniectomia Descompressiva , Polimetil Metacrilato , Humanos , Craniectomia Descompressiva/efeitos adversos , Craniectomia Descompressiva/métodos , Estudos Retrospectivos , Crânio/cirurgia , Crânio/lesões , Remodelação Óssea , Resultado do Tratamento
18.
Ann 3D Print Med ; 132024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38405263

RESUMO

In this manuscript we assessed the utility of a low-cost 3D printed microscope to evaluate esophageal biopsies. We conducted a comparative analysis between the traditional microscope and our 3-D printed microscope, utilizing a set of esophageal biopsy samples obtained from patients undergoing screening endoscopy. Two pathologists independently examined 30 esophageal biopsies by light microscopy and digital images obtained using a low-cost 3D printed microscope (Observer 1 and 2). The glass slide consensus diagnosis was compared to the findings of 2 additional pathologist who independently just reviewed the digital images (Observer 3 and 4). The intra-observer agreement was substantial to almost perfect for observer 1 (k:0.64) and 2 (k:0.84). All four observers had 100% sensitivity and negative predictive value, whereas specificity ranged from 59% to 100% and positive predictive value ranged from 21% to 100%. The PPV and specificity were lower for the two Observers (3 and 4) who just examined the digital images. Overall, our results suggest that telepathology may be used with high sensitivity and specificity, utilizing the pictures produced by our 3D-printed microscope.

19.
BMC Oral Health ; 24(1): 207, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336704

RESUMO

BACKGROUND: To evaluate the outcome quality of manual and digital orthodontic diagnostic setups in non-extraction cases according to the American Board of Orthodontics model grading system and to calculate the laboratory time needed for orthodontic diagnostic setup construction. METHODS: The sample consisted of 60 pretreatment models of non-extraction orthodontic cases with age ranges of 18-30. The study models were duplicated and scanned with 3Shape R-750 scanner. Digital and manual diagnostic setups were constructed according to their respective treatment plans. Digital diagnostic setups were 3D printed and then both manual and digital setups were assessed using the modified American Board of Orthodontics Cast Radiograph evaluation score (ABO CRE), which includes alignment, marginal ridge, buccolingual inclination, occlusal contacts, occlusal relationships, interproximal contacts, and overjet. The laboratory time needed for orthodontic setups was measured in minutes. RESULTS: The total ABO CRE score of the digital diagnostic setup group (5.93 ± 2.74) was significantly lower than that of the manual diagnostic setup group (13.08 ± 3.25). The manual diagnostic setup had significantly larger scores in marginal ridge, overjet, overbite, buccolingual inclination, occlusal relationship, and total scores (P < 0.01). However, the digital diagnostic setup had a statistically larger occlusal contacts score than the manual diagnostic setup (P < 0.01). There was no significant difference between the alignment and the interproximal contacts scores in either group. The manual diagnostic setup needed significantly longer laboratory time (187.8 ± 14.22) than the digital setup (93.08 ± 12.65) (P < 0.01). Comparison between broken teeth was performed by using the chi-square test which found no significant difference between different tooth types. CONCLUSIONS: Digital diagnostic setup is a reliable tool for orthodontic diagnostic setup construction providing excellent quality setup models. Manual diagnostic setup is time consuming with a technique-sensitive laboratory procedure.


Assuntos
Má Oclusão Classe II de Angle , Ortodontia , Dente , Humanos , Estados Unidos , Má Oclusão Classe II de Angle/terapia
20.
Biochem Biophys Rep ; 38: 101656, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38379857

RESUMO

Introduction & objectives: Stem cell therapy for regenerative medicine has been sincerely investigated, but not still popular although some clinical trials show hopeful results. This therapy is suggested to be a representative candidate such as bone defect due to the accident, iatrogenic resection oncological tumor, congenital disease, and severe periodontitis in oral region. Recently, the Bio-3D printer "Regenova®" has been introduced as an innovative three-dimensional culture system, equipped scaffold-free bio-assembling techniques without any biomaterials. Therefore, we expected a mount of bone defect could be repaired by the structure established from this Bio-3D printer using osteogenic potential stem cells. Material & methods: The gingival tissue (1x1 mm) was removed from the distal part of the lower wisdom tooth of the patients who agreed our study. Human Gingival Mesenchymal Stem Cells (hGMSCs) were isolated from this tissue and cultured, since we confirmed the characteristics such as facile isolation and accelerated proliferation, further, strong potential of osteogenic-differentiation. Spheroids were formed using hGMSC in 96-well plates designed for low cell adhesion. The size of the spheroids was measured, and fluorescent immunostaining was employed to verify the expression of stem cell and apoptosis marker, and extracellular matrix. Following four weeks of bone differentiation, µCT imaging was performed. Calcification was confirmed by alizarin red and von Kossa staining. Fluorescent immunostaining was utilized to assess the expression of markers indicative of advanced bone differentiation. Results: We have established and confirmed the spheroids (∼600 µm in diameter) constructed from human GMSCs (hGMSCs) still maintain stem cell potentials and osteogenic differentiation abilities from the results that CD73 and not CD34 were expressed as stem cell positive and negative marker, respectively. These spheroids were pilled up like cylindal shape to the "Kenzan" platform of Bio-3D printer and cultured for 7days. The cylindal structure originated from compound spheroids were tried to differentiate into bone four weeks with osteogenic induction medium. The calcification of bio-3D printed bone-like structures was confirmed by alizarin red and Von Kossa staining. In addition, µCT analysis revealed that the HU (Hounsfield Unit) of the calcified structures was almost identical to that of trabecular bone. Immunofluorescent staining detected osteocalcin expression, a late-stage bone differentiation marker. Conclusion: For the first time, we have achieved the construction of a scaffold-free, bone-like luminal structure through the assembly of spheroids comprised of this hGMSCs. This success is sure to be close to the induction of clinical application against regenerative medicine especially for bone defect disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...