Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.823
Filtrar
1.
J Fluoresc ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985395

RESUMO

Adhesive dentistry has made it feasible to design restorations with high aesthetic qualities and little invasiveness. However, the freshly cut dentin after the tooth preparation needs to be sealed to prevent its contaminations, bacterial leakage, and hypersensitivity. Consequently, the immediate dentin sealing (IDS) method has been advised. This study examines different dentinal tubule sealing methods via CO2 laser, diode laser (980-nm) and a two-step self-etch adhesive system applied directly to the fresh cut dentin preceding the placement of the provisional phase. The sealing efficiency of each laser and bond system was evaluated based on the laser-induced fluorescence (LIF) properties and image analysis by scanning electron microscopy. Moreover, the obtained LIF spectra were evaluated using partial least square progression. A two-step adhesive containing a high concentration of S-PRG fillers produced a thick layer that was not perfectly uniform at all sites due to uneven filler distribution in the bond with totally and partially closed dentinal tubules. However, the peaks of the LIF spectra dropped after applying laser because of its sealing effectiveness. Accordingly, CO2 and diode lasers have strong evidence in dentinal tubule sealing and a definitive treatment modality for dentinal hypersensitivity. Moreover, IDS with an adhesive system is superior in occluding dentinal tubules in a biomimetic manner based on its filler content and bioactive properties.

2.
J Conserv Dent Endod ; 27(6): 621-625, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989483

RESUMO

Aim: The study aimed to comparatively evaluate the effect of eugenol exposure time on the micro-shear bond strength (µ-SBS) of etch-and-rinse and a self-etch adhesive to dentin. Materials and Methods: One hundred and twelve teeth samples were prepared from bisectioning 56 freshly extracted human mandibular molars and were randomly divided into 14 subgroups of 8 samples each (n = 8). Three subgroups containing eugenol and a noneugenol-based restorative material were placed on the dentin surface and left for 24 h, 7 days, and 14 days, respectively, and were compared to a control. Two bonding systems were evaluated: one being etch-and-rinse and the other self-etch adhesive. The µ-SBS were calculated and expressed in MPa. Statistical Analysis: The data were analyzed using mixed model analysis of variance. The level of statistical significance was set at 5%. Results: There was a statistically significant reduction in the µ-SBS values when the self-etch adhesive was used, after the removal of eugenol-containing cement placed for 24 h. However, the reduction in the µ-SBS values after 7 days or 14 days was not significant. Conclusion: Exposure to eugenol containing temporary cement for 24 h significantly reduces the µ-SBS of self-etching adhesives to dentin. However, exposure for 1 week or more has minimal effects.

3.
Bioact Mater ; 40: 334-344, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38978803

RESUMO

Volumetric muscle loss (VML) frequently results from traumatic incidents and can lead to severe functional disabilities. Hydrogels have been widely employed for VML tissue regeneration, which are unfortunately ineffective because of the lack of intimate contact with injured tissue for structural and mechanical support. Adhesive hydrogels allow for strong tissue connections for wound closure. Nevertheless, conventional adhesive hydrogels exhibit poor tissue adhesion in moist, bleeding wounds due to the hydration layer at the tissue-hydrogel interfaces, resulting in insufficient performance. In this study, we developed a novel, biocompatible, wet tissue adhesive powder hydrogel consisting of dextran-aldehyde (dex-ald) and gelatin for the regeneration of VML. This powder absorbs the interfacial tissue fluid and buffer solution on the tissue, spontaneously forms a hydrogel, and strongly adheres to the tissue via various molecular interactions, including the Schiff base reaction. In particular, the powder composition with a 1:4 ratio of dex-ald to gelatin exhibited optimal characteristics with an appropriate gelation time (258 s), strong tissue adhesion (14.5 kPa), and stability. Dex-ald/gelatin powder hydrogels presented strong adhesion to various organs and excellent hemostasis compared to other wet hydrogels and fibrin glue. A mouse VML injury model revealed that the dex-ald/gelatin powder hydrogel significantly improved muscle regeneration, reduced fibrosis, enhanced vascularization, and decreased inflammation. Consequently, our wet-adhesive powder hydrogel can serve as an effective platform for repairing various tissues, including the heart, muscle, and nerve tissues.

4.
Front Immunol ; 15: 1380889, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38979412

RESUMO

Background: Mounting evidence suggests a connection between inflammatory cytokines and adhesive capsulitis (AC). However, the specific systemic inflammatory cytokines contributing to AC have not been clearly identified. This study employed Mendelian randomization (MR) to explore the causal relationships between 41 inflammatory cytokines and AC. Methods: In this bidirectional, two-sample MR analysis, genetic variations associated with AC were derived from a comprehensive genome-wide association study (GWAS). The inflammatory cytokines data were sourced from a GWAS summary involving 8,293 healthy participants. The primary MR method employed was inverse variance weighting, supplemented by MR-Egger, weighted median, and MR-pleiotropy residual sum and outlier for sensitivity analysis. Heterogeneity was assessed using Cochran's Q test, and the MR results were validated using the leave-one-out method. Results: Elevated levels of interferon gamma-induced protein 10 (IP-10) (odds ratio (OR) = 1.086, 95% confidence interval (CI) = 1.002-1.178) and regulated on activation, normal T cell expressed and secreted (RANTES) (OR = 1.107, 95% CI = 1.026-1.195) were linked to an increased risk of AC. Increased levels of stromal cell-derived factor-1 alpha (SDF-1α) (OR = 0.879, 95% CI = 0.793-0.974) and tumor necrosis factor-alpha (TNF-α) (OR = 0.911, 95% CI = 0.831-0.999) were associated with a reduced AC risk. Moreover, genetically predicted AC exhibited associations with elevated cutaneous T cell attracting (CTACK) levels (OR = 1.202, 95% CI = 1.007-1.435) and diminished levels of interleukin-17 (IL-17) (OR = 0.678, 95% CI = 0.518-0.888) and interleukin-5 (IL-5) (OR = 0.786, 95% CI = 0.654-0.944), as confirmed through inverse-variance weighted (IVW) methods. Conclusion: The present study successfully establishes a causal association between genetically proxied circulating levels of IP-10, RANTES, SDF-1α, and TNF-α and the risk of AC. Additionally, AC contributes to an increase in CTACK and a decrease in IL-17 and IL-5. This significant finding not only enhances the understanding of the pathogenesis of AC but also holds promise for the development of effective clinical management strategies.


Assuntos
Bursite , Citocinas , Estudo de Associação Genômica Ampla , Análise da Randomização Mendeliana , Polimorfismo de Nucleotídeo Único , Humanos , Citocinas/sangue , Citocinas/genética , Bursite/genética , Predisposição Genética para Doença , Mediadores da Inflamação/metabolismo , Mediadores da Inflamação/sangue
5.
Artigo em Inglês | MEDLINE | ID: mdl-38984525

RESUMO

Novel reprocessable thermosetting adhesives (RTAs), which combine high adhesive strength, reusability, disassembly, and recyclability features, have attracted increasing attention. However, developing RTAs with a rapidly adhesive rate while ensuring high adhesive strength and self-healing ability is still a significant challenge. Here, we prepared a novel vitrimer called DAx-DTSAy, which can be used as an RTA. First, by adjusting the ratio of rigid and flexible segments, maximum tensile strength reached 35.92 MPa. Second, the combined effect of dynamic hydroxyl ester bonds and dynamic disulfide bonds resulted in a rapid stress relaxation behavior, with a complete relaxation time 13.6 times shorter than a vitrimer only cross-linked with hydroxy ester bonds. This feature endowed its good self-healing and reprocessing capabilities. After self-healing at 180 °C, the maximum healing rate of mechanical properties was 91.8%. After three reprocesses, the maximum recovery rate of tensile strength was 120.2%. Furthermore, the combination of rigid and flexible segments and the synergistic effect of dual dynamic covalent bonds made DAx-DTSAy capable of use as a high-performance RTA. The lap shear strength of a DAx-DTSAy film on stainless steel reached 18.18 MPa after 15 min, with a recovery rate of 91.9% after 5 rebonding cycles. Additionally, DAx-DTSAy can be disassembled in chemical agents and exhibited better insulation properties compared to traditional epoxy resins. DAx-DTSAy can be employed as a novel high-performance adhesive in applications such as electronic devices and transportation, contributing to the development of thermosetting adhesives toward recyclability and sustainability.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38954606

RESUMO

The design of adhesive and conductive soft hydrogels using biopolymers with tunable mechanical properties has received significant interest in the field of wearable sensors for detecting human motions. These hydrogels are primarily fabricated through the modification of biopolymers to introduce cross-linking sites, the conjugation of adhesive components, and the incorporation of conductive materials into the hydrogel network. The development of a multifunctional copolymer that integrates adhesive and conductive properties within a single polymer chain with suitable cross-linking sites eliminates the need for biopolymer modification and the addition of extra conductive and adhesive components. In this study, we synthesized a copolymer based on poly([2-(methacryloyloxy)ethyl] trimethylammonium chloride-co-dopamine methacrylamide) (p(METAC-DMA)) using a controlled radical polymerization, allowing for the efficient conjugation of both adhesive and conductive units within a single polymer chain. Subsequently, our multifunctional hydrogel named Gel-MD was fabricated by mixing the p(METAC-DMA) copolymer with non-modified gelatin in which cross-linking took place in an oxidative environment. We confirmed the biocompatibility of the Gel-MD hydrogel through in vitro studies using NIH 3T3 cells as well as in vivo subcutaneous implantation in rats. Furthermore, the Gel-MD hydrogel was effective and sensitive in detecting various human motions, making it a promising wearable sensor for health monitoring and diagnosis.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38963006

RESUMO

Shape-anisotropic hydrogel microparticles have attracted considerable attention for drug-delivery applications. Particularly, nonspherical hydrogel microcarriers with enhanced adhesive and circulatory abilities have demonstrated value in gastrointestinal drug administration. Herein, inspired by the structures of natural suckers, we demonstrate an ionic polymerization-based production of calcium (Ca)-alginate microparticles with tunable shapes from Janus emulsion for the first time. Monodispersed Janus droplets composed of sodium alginate and nongelable segments were generated using a coflow droplet generator. The interfacial curvatures, sizes, and production frequencies of Janus droplets can be flexibly controlled by varying the flow conditions and surfactant concentrations in the multiphase system. Janus droplets were ionically solidified on a chip, and hydrogel beads of different shapes were obtained. The in vitro and in vivo adhesion abilities of the hydrogel beads to the mouse colon were investigated. The anisotropic beads showed prominent adhesive properties compared with the spherical particles owing to their sticky hydrogel components and unique shapes. Finally, a novel computational fluid dynamics and discrete element method (CFD-DEM) coupling simulation was used to evaluate particle migration and contact forces theoretically. This review presents a simple strategy to synthesize Ca-alginate particles with tunable structures that could be ideal materials for constructing gastrointestinal drug delivery systems.

8.
J Wound Care ; 33(7): 509-514, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38967347

RESUMO

OBJECTIVE: Medical adhesive-related skin injuries (MARSI), defined as skin damage associated with the use of medical adhesive products or devices, are a common and under-reported condition that compromises skin integrity. The prevention and management of MARSI that can occur around the needle insertion site of a chest wall implantable port in hospitalised patients with a tumour remain challenging issues. The aim of this study was to explore whether the incidence of MARSI could be reduced by changing the body position during dressing changes. METHOD: Participants were recruited between May 2019 and November 2020 in the oncology department of a tertiary hospital. Patients were randomly assigned to Group AB (supine followed by semi-recumbent position) and Group BA (semi-recumbent followed by supine position) with a standard intervening recovery interval of 21-28 days. Assessments for typical MARSI included itching, the combination of erythema and oedema, and blisters in the port area, and were graded according to the level of severity. RESULTS: The itch intensity was significantly lower in phase B (semi-recumbent) compared to phase A (supine) (2.35±1.985 versus 5.31±1.332, respectively; p<0.01). Similarly, the severity of erythema and oedema was less severe when comparing phase B to phase A: grade 0 (64.9% versus 10.5%, respectively); grade 1 (28.1% versus 19.3%, respectively); grade 2 (3.5% versus 7.0%, respectively); grade 3 (1.8% versus 45.6%, respectively); and grade 4 (1.8% versus 17.5%, respectively) (Z=5.703; p<0.01). Blisters were found far less frequently in phase B than phase A (1.8% versus 56.1%, respectively; p<0.01). CONCLUSION: The study provided statistically significant evidence that patients in a semi-recumbent position receiving dressing at a chest wall implantable port had fewer and less severe injection site MARSI than when in a supine position. DECLARATION OF INTEREST: The authors have no conflicts of interest to declare.


Assuntos
Adesivos , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Incidência , Idoso , Adulto , Adesivos/efeitos adversos , Bandagens , Pele/lesões , Posicionamento do Paciente/efeitos adversos , Postura
9.
Nurs Crit Care ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38955490

RESUMO

BACKGROUND: Clinical practice guidelines for the prevention of catheter associated urinary tract infection (CAUTI) recommend urinary catheter securement in critical patients although there is scant research on its effectiveness. AIM: To analyse whether securement of an indwelling urinary catheter (IUC) reduces the risk of CAUTI and meatal pressure injury among intensive care unit (ICU) patients and assess medical adhesive-related skin injury (MARSI) associated with the securement device. STUDY DESIGN: Open randomized controlled trial involving patients admitted to two ICUs in Spain. In the intervention group (n = 169 patients), the IUC was secured to the thigh using an in-house device piloted as part of this trial. Controls (n = 181) received standard care, including non-securement of the IUC. Barrier film spray was applied to the securement site with the aim of preventing MARSI. The definitions of the main outcomes were: CAUTI was diagnosed according to the criteria of the European Centre for Disease Prevention and Control, meatal pressure injury was categorized into four grades and MARSI was classified as either erythema or skin tears. Bivariate analysis and multivariate logistic regression were performed. Log-rank and Cox regressions were used to compare risk over time to CAUTI and meatal pressure injury in the two groups. RESULTS: Data from 350 patients were analysed, 169 (48.29%) from IG and 181 (51.71%) from CG. In the multiple logistic regression analysis, IUC securement was an independent protective factor against both CAUTI (RR = 0.2, 95% CI [0.05, 0.67]) and meatal pressure injury (RR = 0.31, 95% CI [0.15, 0.58]). The incidence of MARSI was 7.1%. CONCLUSION: Effective IUC securement significantly reduces the risk of CAUTI and meatal pressure injury among ICU patients. The in-house device piloted in the present trial is simple for nurses to use, and the incidence of MARSI was low. These results underline the benefits of IUC securement. RELEVANCE TO CLINICAL PRACTICE: Indwelling urinary catheter (IUC) securement reduces the risk of urinary tract infection. IUC securement helps prevent meatal pressure injury. IUC securement with in-house devices is safe and effective.

10.
J Contemp Dent Pract ; 25(4): 342-345, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38956849

RESUMO

AIM: The purpose of this study was to evaluate the effectiveness and strength of three various dentin-bonding agents used with adhesives on primary teeth. MATERIALS AND METHODS: The study used 80 recently extracted, healthy human maxillary anterior primary teeth that had undergone physiologic resorption, or over-retention. Teeth were cut to expose a flat dentin surface at a depth of 1.5 mm. All samples were divided into four groups (20 samples in each group) as follows: Group I-Control group, Group II-Primary teeth bonding with 6th-generation bonding agent, Group III-Primary teeth bonding with 7th-generation bonding agent, Group IV-Primary teeth bonding with 8th-generation bonding agent. All of the samples' dentinal surfaces were covered with composite resin using a Teflon mold after adhesive had been applied. A universal testing machine (INSTRON) was used to assess the shear bond strength. Data were collected and statistically analyzed. RESULTS: The maximum mean shear bond strength was found in 8th-generation bonding agent (30.76 ± 0.16), followed by 7th-generation bonding agent (26.08 ± 0.21), 6th-generation bonding agent (25.32 ± 0.06), and control group (6.18 ± 0.09). Statistically significant difference was found between the three different bonding agents (p < 0.001). CONCLUSION: On conclusion, the 8th-generation bonding agent demonstrated a greater shear bond strength to dentin than the 7th and 6th-generation bonding agent. CLINICAL SIGNIFICANCE: The emergence of different bonding techniques to the market improves the durability and quality of restorations. An effective bonding to the tooth would also reduce bacterial penetration, marginal microleakage, possibility of pulpal inflammation preserve tooth structure, and postoperative sensitivity by allowing less cavity preparation. How to cite this article: Alqarni AS, Al Ghwainem A. Assessment of the Efficacy and Bond Strength of Different Dentin-bonding Agents with Adhesives on Primary Teeth: An In Vitro Study. J Contemp Dent Pract 2024;25(4):342-345.


Assuntos
Colagem Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Resistência ao Cisalhamento , Dente Decíduo , Humanos , Adesivos Dentinários/química , Colagem Dentária/métodos , Técnicas In Vitro , Resinas Compostas , Teste de Materiais , Cimentos de Resina , Dentina/efeitos dos fármacos , Cimentos Dentários/uso terapêutico
11.
Clin Epidemiol ; 16: 447-459, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952571

RESUMO

Background: Frozen shoulder may be an early preclinical symptom of Parkinson's disease (PD). Objective: To examine PD risk after frozen shoulder diagnosis and to evaluate this disorder as a possible manifestation of parkinsonism preceding the clinical recognition of PD and possible target for screening. Methods: Danish population-based medical registries were used to identify patients aged ≥40 years with a first-time frozen shoulder diagnosis (1995-2016). A comparison cohort was randomly selected from the general population matched on age and sex. To address detection bias and the specificity of frozen shoulder diagnosis, we performed a sensitivity analysis, using similar matching criteria to select a cohort of patients with back pain diagnosis. The outcome was incident PD. Cumulative incidences and adjusted hazard ratios (HRs) were estimated with 95% confidence intervals (CIs). Results: We identified 37,041 individuals with frozen shoulder, 370,410 general population comparators, and 111,101 back pain comparators. The cumulative incidence of PD at 0-22 years follow-up was 1.51% in the frozen shoulder cohort, 1.03% in the general population cohort, and 1.32% in the back pain cohort. For frozen shoulder versus general population, adjusted HRs were 1.94 (CI: 1.20-3.13) at 0-1 years and 1.45 (CI: 1.24-1.70) at 0-22 years follow-up. For frozen shoulder versus back pain, adjusted HRs were 0.89 (CI: 0.54-1.46) and 1.01 (CI: 0.84-1.21), respectively. Conclusion: Patients with frozen shoulder had an increased PD risk compared with the general population, although the absolute risks were low. Frozen shoulder might sometimes represent early manifestations of PD. Detection bias probably cannot account for the increased PD risk during the long-term follow-up.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38953970

RESUMO

The risk of adhesive capsulitis of shoulder in diabetic patients taking metformin has not been evaluated. We aimed for evaluating the relative risk of adhesive capsulitis of shoulder in diabetic patients taking metformin at the level of the whole country population. We conducted a retrospective cohort study using a national health insurance database in Taiwan from 2000 to2015. We used International Classification of Diseases, Ninth Revision, to categorise the medical condition for study group and comparison group. We used Cox proportional hazard regression analyses to determined adjusted hazard ratios (aHRs) of adhesive capsulitis of shoulder between study and comparison group after adjusting for sex, age, and comorbidities.Among 30,412 diabetic patients using metformin, 3020 patients were diagnosis with adhesive capsulitis of shoulder during follow up. Of the 121,648 patients without the use of metformin, 11,375 patients developed adhesive capsulitis of shoulder. Adhesive capsulitis of shoulder risk was elevated in patients taking metformin than in non-metformin group (adjusted hazard ratio [HR] 1.179, 95% confidence interval [95% CI] 1.022 to 1.268; p = 0.039). Risk of adhesive capsulitis of shoulder among the diabetic patients taking metformin was higher than those did not taking metformin.

13.
Int J Biol Macromol ; : 133655, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38969029

RESUMO

Integrated wound care, a sequential process of promoting wound hemostasis, sealing, and healing, is of great clinical significance. However, the wet environment of wounds poses formidable challenges for integrated care. Herein, we developed an epidermal growth factor (EGF)-loaded, dehydrated physical microgel (DPM)-formed adhesive hydrogel for the integrated care of wet wounds. The DPMs were designed using the rational combination of hygroscopicity and reversible crosslinking of physical hydrogels. Unlike regular bioadhesives, which consider interfacial water as a barrier to adhesion, DPMs utilize water to form desirable adhesive structures. The hygroscopicity allowed the DPMs to absorb interfacial water and subsequently, the interfacial adhesion was realized by the interactions between tissue and DPMs. The reversible crosslinks further enabled DPMs to integrate into hydrogels (DPM-Gels), thus achieving wet adhesion. Importantly, the water-absorbing gelation mode of DPMs enabled facile loading of biologically active EGF to promote wound healing. We demonstrated that the DPM-Gels possessed wet tissue adhesive performance, with about 40 times the wet adhesive strength of fibrin glue and about 4 times the burst pressure of human blood pressure. Upon application at the injury site, the EGF-loaded DPM-Gels sequentially promoted efficient wound hemostasis, stable sealing, and quick healing, achieving integrated care of wet wounds.

14.
Dent Mater J ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38960667

RESUMO

The purpose of this study was to evaluate the effect of the atmospheric pressure plasma treatment as a surface treatment method on the contact angle and shear bond strength (SBS) of zirconia ceramics and the failure mode between the self-adhesive resin luting agent and zirconia. The zirconia specimens were divided into eight groups based on the surface treatment method: alumina blasting, air plasma, argon plasma (AP), Katana cleaner, ozonated water, ozonated water+AP, Katana cleaner+AP, and tap water+AP. The contact angles, SBS, and fracture modes were tested. AP treatment significantly reduced the contact angle (p<0.0001). The combination of AP and other cleaning methods showed a higher bond strength and more mixed fractures. Our findings indicate that using atmospheric pressure plasma with argon gas, combined with other cleaning methods, results in a stronger bond than when using alumina blasting alone.

15.
Pain Manag ; : 1-6, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38973311

RESUMO

We present a case of deep surgical site infection (SSI) at a spinal cord stimulator (SCS) trial implantation site, resulting from an allergic reaction to an unknown agent. A 38-year-old female with complex regional pain syndrome began an SCS trial, noting 100% pain relief for 5 days. Fluid drainage from the surgical site was reported on POD6 and trial leads were removed the following day. The patient was hospitalized with sepsis. Blood cultures revealed Staphylococcus aureus. MRIs showed skin breakdown and cellulitis of the paraspinal musculature extending into the epidural space. The patient was maintained with antibiotics and rigorous wound care for 9 days and the surgical site infection resolved. The patient proceeded to SCS implantation, and reported good pain relief with the implanted device.


This case report describes the treatment of an infection developed during a spinal cord stimulator (SCS) trial period. SCS are medical devices used to treat pain, they work by applying electrical current to the areas of the spinal cord that cause patients' pain. Before patients get an SCS device implanted, they often undergo a trial period first. During a trial, the stimulator device stays outside the body, and only the wires carrying electricity to the spinal cord are implanted. Typically, SCS trial and implantation procedures are safe and result in effective pain relief. However, infections are a dangerous potential complication that can result from these procedures. In our case, the patient developed an infection during an SCS trial period, likely resulting from an allergic reaction to their surgical dressings. The infection traveled down the wires and nearly reached the spinal cord. Since the infection was quickly identified and managed, devastating complications were avoided. The patient was able to get a permanent SCS after the infection was resolved, and had effective pain relief. Our report emphasizes the importance of using strict infection prevention techniques, and monitoring patients for signs of infection throughout SCS trials.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38970565

RESUMO

Intrinsic conducting hydrogels fabricated in situ at low temperatures with self-adhesive properties and excellent flexibility hold significant promise for energy applications and outdoor damage repair. However, challenges such as low polymerization rate and self adhesion, insufficient ionic conductivity, inflexibility, and poor stability under extreme cold conditions have hindered their utilization as high-performance sensors. In this study, we designed an intrinsic conducting hydrogel (PADOC) composed of acrylic acid, acryloyloxyethyltrimethylammonium chloride, N,N'-methylenebis(2-propenamide), self-fabricated oxidized curdlan (OC), and a water/glycerol binary solvent. The novel hydrogel exhibited rapid gelation (30 s) at 0 °C facilitated by the promotion of OC, without the need for external energy input. Our findings from FT-IR, NMR, XPS, XRD, EPR spectra, MS, and DSC analyses revealed that OC underwent selective oxidation via the evolved Fenton reaction at 30 °C, serving as bioaccelerators for PAD polymerization. Due to OC's reductive structure and increased solubility, the reaction activation energy of the PAD polymerization reaction significantly reduced from 103.2 to 54.4 kJ/mol. PADOC ionic hydrogels demonstrated an electrical conductivity of 1.00 S/m, 0.7% low hysteresis, 39.6 kPa self-adhesive strength, and 923% strain-at-break and kept even at -20 °C owing to dense hydrogen and ionic bonds between PAD and OC chains. Furthermore, PADOC ionic hydrogels exhibited antifatigue properties for 10 cycles (0-100%) due to electrostatic interactions and hydrogen bonding. Remarkably, using a self-designed device, the rapid polymerization of PADOC effectively repaired copper pipeline leakage under 86 kPa pressure and detected 1% strain variation as a strain sensor. This study opens a new avenue for the rapid gelation of self-adhesive and flexible intrinsic conducting hydrogels with robust sensor performance.

17.
J Pediatr Nurs ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38971633

RESUMO

Purpose To compare the effectiveness of sunflower oil and silicone-based spray used to remove medical adhesives from the orogastric catheter in preventing the skin injury of premature infants in the neonatal intensive care unit. METHODS: This randomized controlled experimental study was conducted on premature infants, born between 32 and 36 weeks, hospitalized in the Neonatal Intensive Care Unit located in the city center of the Black Sea region. There were 86 participants in the study; 43 were in the control group (silicone-based spray), and 43 were in the intervention group (sunflower oil). The "Neonatal Skin Condition Score Scale" evaluated premature infants' skin. RESULTS: Mean skin condition score of premature infants for whom silicone-based adhesive remover spray was applied was 3.63 ± 0.78, whereas the mean skin condition score measured three hours later was 3.17 ± 0.37. Mean skin condition score of premature infants for whom sunflower oil was applied as a medical adhesive remover was 3.40 ± 0.62, whereas the mean skin condition score measured three hours later was 3.07 ± 0.25. No statistically significant difference was determined between the mean skin condition scores of premature infants in both groups evaluated immediately after removing the medical adhesive and 3 h there after (p>0.05). CONCLUSIONS: There is no difference between the skin condition of premature infants for whom silicone-based medical adhesive remover spray is used and the skin condition of premature infants for whom sunflower oil is used to remove the orogastric tube adhesive. PRACTICE IMPLICATIONS: Pediatric nurses should use medical supplies suitable for the skin condition of premature infants and should frequently evaluate the baby's skin condition. Since silicone-based adhesive remover sprays have a risk of toxicity by being absorbed by the skin, it is recommended to use herbal, cost-effective, non-toxic products. CLINICAL TRIAL NUMBER: NCT06280326.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38905448

RESUMO

BACKGROUND: Rheumatoid Arthritis is an autoimmune disorder that leads to persistent symmetrical polyarthritis accompanied by systemic manifestations. It may lead to an array of deformities and even complications like rheumatoid nodules, carpal tunnel syndrome, adhesive capsulitis, cardiovascular diseases, and many more. OBJECTIVES: This case report intends to discuss the ayurvedic management of Rheumatoid Arthritis which was complicated by Adhesive Capsulitis. METHODS: A 73-year-old male patient was diagnosed with Rheumatoid Arthritis. He had previously undergone allopathic treatment for a year. In June 2023, the patient sought ayurvedic treatment for his ailment and later acquired signs and symptoms of Adhesive Capsulitis. He was given ayurvedic oral medications along with external therapeutic procedures. RESULTS: There was a significant reduction in the values of the Routine Assessment of Patient Index Data 3 (RAPID3) score, Clinical Disease Activity Index (CDAI), Rheumatoid Factor (Quantitative), Visual Analogue Scale (VAS), and improvement in the range of movement of the affected joint. CONCLUSIONS: Ayurvedic medicines are effective in managing Rheumatoid Arthritis along with the complication of Adhesive Capsulitis.

19.
Materials (Basel) ; 17(11)2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38893825

RESUMO

Adhesive bonding has proven to be a reliable method of joining materials, and the development of new adhesives has made it possible to use bonding in a variety of applications. This article addresses the challenges of bonding metals such as the aluminum alloy EN AW-5754 and the stainless steel X5CrNi18-10. In this study, the effects of laser cleaning and texturing on the surface properties and strength of two bonded joints were investigated and compared with mechanical preparation (hand sanding with Scotch-Brite and P180 sandpaper). The bonded joints were tested with three different epoxy adhesives. During the tests, the adhesion properties of the bonded surface were determined by measuring the contact angle and assessing the wettability, the surface roughness parameters for the different surface preparations, and the mechanical properties (tensile lap-shear strength). Based on the strength test results, it was found that bonded joints made of stainless steel had 16% to 40% higher strength than aluminum alloys when using the same adhesive and surface preparation. Laser cleaning resulted in maximum shear strength of the aluminum alloy bond, while the most suitable surface preparation for both materials was preparation with P180 sandpaper for all adhesives.

20.
Clin Oral Investig ; 28(7): 386, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38890207

RESUMO

OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.


Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cimentos de Resina , Humanos , Cimentos de Resina/química , Colagem Dentária/métodos , Dentina/efeitos da radiação , Técnicas In Vitro , Adesivos Dentinários/química , Análise do Estresse Dentário , Propriedades de Superfície , Raiz Dentária/efeitos da radiação , Ultrassom , Condicionamento Ácido do Dente , Incisivo , Vidro/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...