Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Chinese Pharmaceutical Journal ; (24): 1699-1705, 2016.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-858961

RESUMO

OBJECTIVE: To establish a microwave extraction-HPLC method for determination of antioxidant 1010, antioxidant 330, antioxidant 1076, and antioxidant 168 in plastic infusion packaging materials and containers, and investigate the migration of the antioxidants from the materials to the injection. METHODS: Taking the contents of antioxidants as indices, the best extraction condition was determined with or thogonal experiments and statistical analysis. The separation of antioxidants was performed on a Sunfire-C18 (4.6 mm×150 mm, 5 μm) chromatographic column at 40℃, and the detection wavelength was set at 280 nm. The mobile phase consisted of acetonitrile, tetrahydrofuran, and water (6∶3∶1) at a flow rate of 1.5 mL·min-1, and the injection volume was 20 μL. RESULTS: The optimized extraction process was extracting 2 g of sample at 100℃ for 30 min. The calibration curves of antioxidant 1010, antioxidant 330, antioxidant 1076, and antioxidant 168 were linear over the concentration range from 0.004 to 0.5 mg·mL-1 (r=0.999 9) and the average recoveries of the antioxidants ranged from 96.8% to 103.7% (RSD<2%, n=9). CONCLUSION: This method is convenient, sensitive, and reliable and it can be used for the determination of antioxidants in plastic infusion materials and their migration to the injection.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-853669

RESUMO

Objective: To optimize the matrix proportion of SIS hot melt pressure sensitive adhesive suit for hydrophilic material releasing. Methods: By orthogonal test method, taking adhesiveness and hydrophilic drug release rate as factors, and C5 petroleum resin hydrogenate, lanoline styrene-isoprene-styrene (SIS) triblock copolymer, ethyl acrylate-methyl methacrylate-trimethylamino (RLPO), liquid paraffin, dibutyl phthalate (DOP), polyethylene glycol (PEG) 400, and Antioxidant 1010 as materials, the matrix proportion was optimized. Results: The optimized formulation was as follows: SIS-C5 petroleum resin hydrogenate-SIS-RLPO-DOP-PEG 400-Antioxidant 1010 was 3:4:6:6:5:1:0.1. The adhesiveness was proper and shows more release rate for hydrophilic material. Conclusion: The SIS hot melt pressure sensitive adhesive shows good property and is suitable to prepare transdermal patch.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...