Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Environ Res ; 243: 117828, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38048866

RESUMO

The magnetic CuFe2O4/MnO2 heterojunctions were prepared by hydrothermal method, and the effect of different reaction temperature on the physicochemical properties and catalytic activity was investigated. The CuFe2O4/MnO2 heterojunctions prepared at 100 °C can effectively activate peroxymonosulfate (PMS) at multiple application scenarios for degradation and mineralization of tetracycline, o-nitrophenol and ceftriaxone sodium under indoor light, visible light and dark condition. Additionally, the CuFe2O4/MnO2-PMS system showed high catalytic activity and anti-interference ability for degradation of pharmaceutical pollutants in natural water bodies and industrial wastewater. The TC removal efficiency in Qianhu Lake water, Ganjiang River water and tap water was about 88%, 92% and 89%, respectively. The CuFe2O4/MnO2-PMS system is also effective for actual pharmaceutical wastewater treatment with 77.9% of COD removal efficiency. Interestingly, the reactive species of CuFe2O4/MnO2-PMS system under visible light are different from those in dark condition, and the different catalytic mechanisms at multiple application scenarios were proposed. This work provides new insights into mechanism exploration of heterojunction catalyst for PMS activation.


Assuntos
Compostos de Manganês , Óxidos , Peróxidos , Água , Preparações Farmacêuticas
2.
ACS Appl Mater Interfaces ; 15(2): 3131-3140, 2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36603144

RESUMO

Flexible sensors have attracted increasing attention owing to their important applications in human activity monitoring, medical diagnosis, and human-machine interaction. However, the rational design of low-cost sensors with desirable properties (e.g., high sensitivity and excellent stability) and extended applications is still a great challenge. Herein, a simple and cost-effective strategy is reported by immersing polyurethane (PU) sponge in graphene oxide solution followed by in situ chemical reduction to construct a reduced graphene oxide (RGO)-wrapped PU sponge sensor. Ascribed to the excellent compressive resilience of PU sponge and an electrically conductive RGO layer, the constructed flexible sensor exhibits satisfactory sensing performance with high sensitivity (17.65 kPa-1) in a low-load range (0-3.2 kPa), a wide compression strain range (0-80%), and reliable stability (8000 cycles). In addition, these sensors can be successfully applied to monitor human movements and identify the weight of objects. Through the use of a sensor array integrated with a signal acquisition circuit, the reasonably designed sensors can realize tactile feedback via mapping real-time spatial distribution of pressure in complicated tasks and show potential applications in flexible electronic pianos, electronic skin, and remote real-time control of home electronics.


Assuntos
Grafite , Dispositivos Eletrônicos Vestíveis , Humanos , Movimento (Física) , Grafite/química , Movimento , Poliuretanos/química
3.
Biosensors (Basel) ; 13(1)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36671936

RESUMO

Recently, advanced electrodes have been developed, such as semi-dry, dry contact, dry non-contact, and microneedle array electrodes. They can overcome the issues of wet electrodes and maintain high signal quality. However, the variations in these electrodes are still unclear and not explained, and there is still confusion regarding the feasibility of electrodes for different application scenarios. In this review, the physical features and electroencephalogram (EEG) signal performances of these advanced EEG electrodes are introduced in view of the differences in contact between the skin and electrodes. Specifically, contact features, biofeatures, impedance, signal quality, and artifacts are discussed. The application scenarios and prospects of different types of EEG electrodes are also elucidated.


Assuntos
Eletroencefalografia , Pele , Eletroencefalografia/métodos , Impedância Elétrica , Eletrodos , Artefatos
4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-990302

RESUMO

Objective:To analyze the needs and recommendation of nurses in level3 general hospital for the application scenarios of nursing robots, so as to provide a basis for the design of intelligent machine systems to reduce the workload of nurses in the hospitals.Methods:Using phenomenological research methods, a total of 17 clinical nurses from Nanjing Drum Tower Hospital Affiliated to Medical School of Nanjing University, Zhongda Hospital Southeast University and the First People′s Hospital of Lianyungang from November 2021 to March 2022 were selected for semi-structured interviews. Colaizzi content analysis method was used to sort out the data.Results:Clinical nurses′requirements for application scenarios of nursing robots could be summarized into four themes: feasibility of clinical application of robot recognized by nurses; expected alternative care scenarios; summary of nursing robot design features; multiple factors limit the application of nursing robots.Conclusions:Clinical nurses have diverse requirements for the application scenarios of nursing robots, and only part of non-clinical tasks will be authorized to robots in a short period of time. In the face of future opportunities and challenges, with the help of policies, legal supervision should be strengthened, so as to improve the reliability and safety of clinical application of nursing robots.

5.
Membranes (Basel) ; 11(3)2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33804227

RESUMO

In recent decades, the ever-growing demands for clean water in households and industries have urged researchers to take every possible step to deal with the global water crisis. Seawater desalination has turned out to be the most promising and efficient way to provide clean water. Owing to the advancement of synthetic chemistries and technologies, great success has been achieved in the desalination and utilization of seawater worldwide. China, with the world's largest population, has pushed the development of desalination and multipurpose utilization of seawater further in respect of materials, technologies and services, etc. This review reports recent progress of desalination technologies accomplished in China, from the viewpoints of facilities and equipment, collaborations, technologies, applications, research abilities, services, and standard systems. Inspired by the Fourteenth Five-year Plan, it also proposes future perspectives of desalination in China.

6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 44(2): 132-135, 2020 Feb 08.
Artigo em Chinês | MEDLINE | ID: mdl-32400986

RESUMO

It is significant to establish scene ECG database which improves the automatic diagnostic function of electrocardiograph under different application scenarios. We built the ECG database in different scene according to the hospital level (grade 3, grade 2, grade 1) and clinical environment (intensive care and acute wards, outpatient clinics and general wards). Sample size was obtained according to the incidence of various ECG diagnoses. The database covers ECG signal, ECG waveform, ECG characteristic values, ECG diagnostic results by experts and clinical information of patients etc. It not only provides important reference for electrocardiograph manufacturers to evaluate and test the parameters of automatic diagnosis under different clinical scene, but also provides valuable scientific research and teaching resources for medical workers.


Assuntos
Bases de Dados Factuais , Eletrocardiografia , Humanos
7.
ACS Appl Bio Mater ; 3(12): 8188-8210, 2020 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-35019599

RESUMO

Nanomaterials used as novel antimicrobial agents are developed to combat wide-spectrum bacteria as well as alleviate the problem of bacterial resistance to traditional antibiotics. Two-dimensional (2D) nanomaterials are regarded as promising and widely applicable wide-spectrum antibacterial nanoagents due to their outstanding characteristics, including large surface area, stable structure, good biocompatibility, and cheap raw materials, especially excellent photocatalytic or photothermal properties. The advantages of less resistance, rapid sterilization, local action mode, and non-invasive make 2D nanomaterials with photoinduced property stand out in novel sterilization agents. Here, we systematically summarize various kinds of 2D nanomaterials that were used in photoinduced antibacterial field and introduce the synthesis methods and physicochemical properties related to antibacterial capability. Besides, the sterilization mechanisms of different 2D nanomaterials are also introduced in detail including a direct temperature generation, ROS production or ROS-independent oxidative stress, or various synergistic antibacterial modes. Lastly, we have also discussed the current problems of 2D nanomaterials as light-inducing antibacterial agents and their future application prospects in the fields of biomedicine, sewage treatment, food, and other application scenarios. We envision that this review will assist investigators with quick and in-depth understanding of the latest progress in 2D nanomaterials for photoinduced sterilization, inspiring the development of multiply strategies to design and synthesize novel 2D materials with strong bactericidal capability and high biological safety, and expand 2D materials with photoinduced sterilization to more application scenarios.

8.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-942714

RESUMO

It is significant to establish scene ECG database which improves the automatic diagnostic function of electrocardiograph under different application scenarios. We built the ECG database in different scene according to the hospital level (grade 3, grade 2, grade 1) and clinical environment (intensive care and acute wards, outpatient clinics and general wards). Sample size was obtained according to the incidence of various ECG diagnoses. The database covers ECG signal, ECG waveform, ECG characteristic values, ECG diagnostic results by experts and clinical information of patients etc. It not only provides important reference for electrocardiograph manufacturers to evaluate and test the parameters of automatic diagnosis under different clinical scene, but also provides valuable scientific research and teaching resources for medical workers.


Assuntos
Humanos , Bases de Dados Factuais , Eletrocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...