Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Heart Rhythm O2 ; 5(5): 266-273, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38840766

RESUMO

Background: Epicardial connections between the right pulmonary vein (PV) and the right atrium have been reported. Objective: The purpose of this study was to evaluate the usefulness of our new pulmonary vein isolation (PVI) strategy with identification of these epicardial connections. Methods: Overall, 235 patients with atrial fibrillation were included. High-density mapping of the left atrium was performed to identify the earliest activation sites (EASs) before PVI in all patients. With our new strategy, if EASs around the right PV carina were identified, we ablated these sites and performed usual first-pass circumferential PVI. The patients were divided into 2 groups according to the ablation strategy. One hundred fifteen patients underwent first-pass PVI without information on EASs (nonanalyzed group), and 78 patients underwent ablation at EASs around the right PV carina in addition to PVI (analyzed group). After first-pass ablation around the PV antrum, remapping was performed. Results: High-density mapping before PVI showed that the prevalence of EASs around the right PV carina was 10.9% in all patients (9.6% in the nonanalyzed group, 12.8% in the analyzed group; P = .74. The first-pass right PVI success rate was higher in the analyzed group than in the nonanalyzed group (93.6% vs 82.6%; P = .04). The radiofrequency application time for PVI was significantly shorter in the analyzed group than in the nonanalyzed group (45.6 ± 1.0 minutes vs 51.2 ± 0.9 minutes; P <.05). Conclusion: Identification of epicardial connections before ablation could improve the success rate of first-pass right PVI.

2.
Int Dent J ; 73(6): 881-888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37385864

RESUMO

OBJECTIVE: The aim of this research was to investigate the effect of simplified adhesive strategies (self-etch vs selective enamel etch and 10- vs 20-second adhesive application time) on the marginal integrity in primary molars. METHODS: Forty deep class-II cavities were prepared in 40 extracted primary molars. The molars were divided into 4 groups based on the applied universal adhesive strategy as follows: groups 1 and 2: selective enamel etch with 20- or 10-second application time and groups 3 and 4: self-etch with 20- or 10-second application time. All cavities were restored with a sculptable bulk-fill composite restoration. The restorations underwent a thermomechanical loading (TML, 5-50 °C, 2-minute dwelling time, ×1000; 400,000 loading cycles, 1.7 Hz, 49 N). Marginal analysis before and after TML was conducted with scanning electron microscopy and the marginal integrity of each restoration was calculated as a percentage of continuous margins. A beta regression model was adopted to statistically analyse the data with a consequent pairwise comparison. RESULTS: The mean marginal integrity (% ± SD) of the restorations for each tested adhesive strategy after TML was as follows: selective enamel etch/20 seconds = 85.4 ± 3.9, self-etch/20 seconds = 85.3 ± 5.2, self-etch/10 seconds = 80.1 ± 8.2, and selective enamel etch/10 seconds = 80.0 ± 8.5. The difference between both adhesive strategies was not statistically significant at the same application time. The difference between both application times within the same adhesive strategy was statistically significant (P ≤ .01). CONCLUSIONS: Universal adhesives applied either in selective enamel etch or in self-etch mode result in comparable marginal integrities when restoring class-II cavities in primary molars. Shortened adhesive application time (10 seconds) could lead to a reduction in the marginal integrity in comparison to the recommended application time of 20 seconds.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Resinas Compostas/uso terapêutico , Cimentos Dentários/uso terapêutico , Cimentos de Resina/uso terapêutico , Teste de Materiais , Cárie Dentária/prevenção & controle , Dente Decíduo , Adaptação Marginal Dentária , Adesivos Dentinários/uso terapêutico , Restauração Dentária Permanente
3.
J Cardiovasc Electrophysiol ; 34(4): 928-941, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852910

RESUMO

INTRODUCTION: Radiofrequency (RF) catheter ablation induces excitation recoverable myocardium around durable core lesions, and its distribution may be different depending on energy delivery methods. METHODS AND RESULTS: In coronary perfusing porcine hearts, pacing threshold through the ventricle was measured using eight-pole (1-mm distance) needle electrodes vertically inserted into myocardium before, within 3 min after and 40 min after 40 W ablation with 10-g catheter contact (Group 1: irrigation catheter for 15 s, Group 2: irrigation catheter for 40 s, Group 3: nonirrigation catheter for 15 s, Group 4: nonirrigation catheter for 40 s). Ablation was accomplished in all 12 ablations in Groups 1-3 whereas in 8/12 ablations in Group 4 because of high-temperature rise. Within 3 min after ablation, 10.0 V pacing uncaptured electrodes were distributed from the surface to inside the myocardium, and its depth was deeper in 40 s than in 15 s ablation. 40 min after ablation, excitation recovery at one or more electrodes below the durable lesion was observed in all Groups. Excitation recovery electrodes were also observed on the surface in Group 1 but not the other Groups. Accordingly, the number of excitation-recovered electrodes were larger in Group 1 than the other Groups. CONCLUSIONS: Regardless of the ablation methods, excitation recoverable myocardium was present around 1.0 mm below the durable lesions. Lesions created by short application time using an irrigation catheter may have included large excitation recoverable myocardium soon after ablation because of the presence of reversible myocardium on well-irrigated myocardial surfaces.


Assuntos
Ablação por Cateter , Miocárdio , Animais , Suínos , Miocárdio/patologia , Coração , Ablação por Cateter/métodos , Eletrodos , Ventrículos do Coração/cirurgia
4.
Clin Oral Investig ; 27(1): 151-163, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36068369

RESUMO

OBJECTIVE: The aim of this double-blind, randomized clinical trial was to evaluate the 6- and 18-month clinical performances of a new universal adhesive applied in the "no-waiting" (NW) technique to non-carious cervical lesions (NCCLs) using two evaluation criteria. MATERIALS AND METHODS: One hundred and seventy-six restorations were assigned to four groups according to the adhesive system, adhesive strategy, and application mode: Prime&Bond Active (PB) applied using the etch-and-rinse (ER) and self-etch (SE) strategies with 20 s applications and Clearfil Universal Bond Quick (CQ) applied using the ER and SE strategies with the NW technique. The composite resin restorations were evaluated at baseline and after 6 and 18 months using the World Dental Federation (FDI) and US Public Health Service (USPHS) criteria. The Friedman repeated measures analysis of variance and Wilcoxon test were used for statistical analyses (α = 0.05). RESULTS: No significant differences were observed among any of the groups or criteria after 6 months (p > 0.05). After 18 months, 10 restorations were lost (p > 0.05) (2 with PB-ER [95.5%; 95%CI: 92-100%], 4 with PB-SE [90.9%; 95%CI: 82-98%], 0 with CQ-ER [100%; 95%CI: 92-100%], and 4 with CQ-SE [90.9%; 82-98%]). The restorations performed with the SE strategy showed more marginal discrepancies than those performed with the ER strategy, mainly when the FDI criteria were used (p < 0.05). Those that used the PB-SE showed fewer marginal discrepancies than those that used the CQ-SE (FDI; p < 0.05). A few restorations showed marginal discrepancies after the USPHS analysis (p > 0.05). CONCLUSIONS: The results when using the CQ-SE and -ER strategies with the NW technique were similar to those when using the PB-SE and -ER strategies in standard applications to non-carious cervical lesions after 6 and 18 months of clinical evaluation. CLINICAL RELEVANCE: After 6 and 18 months, the application of Clearfil Universal Bond Quick with the "no-waiting" technique showed similar clinical performance compared to the standard application of Prime & Bond Active applied using the standard application time (20 s). TRIAL REGISTRATION: ClinicalTrials.gov identifier RBR-5f9gps.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Adesivos Dentinários/química , Cimentos de Resina/química , Restauração Dentária Permanente/métodos , Método Duplo-Cego , Falha de Restauração Dentária , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Adaptação Marginal Dentária
5.
PeerJ ; 10: e14326, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36411836

RESUMO

Day length is a very critical environmental factor affecting plant growth and development. The extension of light application time has been shown to promote flowering in the long-day plant and to shorten breeding time in some crops. However, previous research on the regulation of bermudagrass flowering by light application time is scarce. Therefore, this study investigated the effect of day length on the growth and flowering of bermudagrass by prolonging the light application time in a controlled greenhouse. Three different light application times were set up in the experiment: 22/2 h (22 hours light/2 hours dark), 18/6 h (18 hours light/6 hours dark), 14/10 h (14 hours light/10 hours dark). Results showed that extending the light application time not only promoted the growth of bermudagrass (plant height, fresh weight, dry weight) but also its nutrient uptake (nitrogen (N) and phosphorous (P) content). In addition, daily light integrals were different when flowering under different light application times. Most importantly, under the 22/2 h condition, flowering time was successfully reduced to 44 days for common bermudagrass (Cynodon dactylon [L.] pers) genotype A12359 and 36 days for African bermudagrass (Cynodon transvaalensis Burtt-Davy) genotype ABD11. This study demonstrated a successful method of bermudagrass flowering earlier than usual time by manipulating light application time which may provide useful insights for bermudagrass breeding.


Assuntos
Cynodon , Melhoramento Vegetal , Cynodon/genética , Genótipo
6.
J Cardiovasc Electrophysiol ; 33(12): 2538-2545, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36135613

RESUMO

INTRODUCTION: Bipolar (BIP) radiofrequency (RF) ablation creates deep myocardial lesions but ideal energy application modes to treat ventricular arrhythmias originating from deep inside the thick myocardium have not been well established. An experimental study was performed to clarify whether high power and long application time BIP ablation were performable by impedance-decline-guide power control (PC) and whether it could create transmural lesions in the thick ventricle with a minimum risk of steam-pop. METHODS AND RESULTS: Perfused porcine ventricle (18.4 ± 2.3 mm) was placed in an experimental bath and BIP ablation (50 W) for 120 s was attempted with catheter contact of 30-g using two protocols; fixed power (FP) and impedance-decline-guide PC. In the latter protocol, BIP ablation was started from 50 W, while the energy was decreased to 40-20 W according to the impedance decline during RF ablation. FP ablation was attempted in 30 applications and the transmural lesion was created in all 30, although steam-pop occurred in 16/30 applications (53%). Low minimum impedance, large total impedance decline (TID), and %-TID were associated with the steam-pop occurrence. PC ablation was attempted in another 21 applications, and the transmural lesion was created in all 21 without steam-pop. PC ablation was superior to FP ablation (21/21 vs. 14/30, p < .001) in the creation of a transmural lesion without resulting in steam-pop. CONCLUSIONS: High power and long application time BIP ablation seems to be feasible according to the impedance-decline-guide approach, which could create transmural lesions in thick porcine ventricles with minimal risk of steam-pop.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Irrigação Terapêutica/métodos , Modelos Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Desenho de Equipamento
7.
Odovtos (En línea) ; 24(1)abr. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386577

RESUMO

Abstract This study evaluated the effects of alternative self-etch application modes on resin-dentin microtensile bond strength (µTBS) of three commercially available "no wait" concept universal adhesives. In this study extracted impacted non-carious human third molars were used. The flat surfaces were prepared in mid-coronal dentin and prepared with a 600-grit SiC paper. The three universal adhesives that were used are as follows: Clearfil Universal Bond Quick (CUQ, Kuraray Noritake, Japan), G-Premio Bond (GPB, GC Corp, Japan), and a self-curing universal adhesive "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japan). The following three different application procedures were used for the dentin surfaces: the adhesives were applied and immediately subjected to air-dry; the adhesives were applied followed by a 10-second wait; or the adhesives were rubbed for 10 seconds. Then composite resin was applied to the dentin surface and light cured. After storage in 37°C distilled water for 24 h, all the bonded teeth were cut into 1mm² sections using a low-speed diamond saw (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turkey) under running water (n=15). The sections were subjected to a tensile force at a crosshead speed of 1mm/min in a testing apparatus (Microtensile Tester, Bisco, IL, USA) and µTBS values were measured. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test. Failure modes were analyzed under a stereomicroscope. Prolonged application time significantly affected the µTBS (p<0.005). A significant increase of µTBS on active application was observed for CUQ and GPB. The TUB with an active application had a significantly lower µTBS value compared with the other adhesives. Prolonged application time caused significant improvement of bond strength in all adhesives. The active application is effective at increasing the dentin bond strength except for TUB.


Resumen Este estudio evaluó los efectos de los modos alternativos de aplicación de adhesivos de autograbado en la resistencia de la unión microtensil entre resina y dentina (µTBS) de tres adhesivos universales de concepto "no espera" disponibles en el mercado. En este estudio se utilizaron terceros molares humanos impactados que fueron extraídos. Las superficies planas se prepararon en la dentina coronal media y se prepararon con un papel SiC de 600 granos. Los tres adhesivos universales que se utilizaron son los siguientes: Clearfil Universal Quick Bond (CUQ, Kuraray Noritake, Japón), G-Premio Bond (GPB, GC Corp, Japón), y un adhesivo universal autopolimerizable "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japón). Se utilizaron los tres procedimientos de aplicación siguientes para las superficies dentinarias: se aplicaron los adhesivos y se sometieron inmediatamente a un secado al aire; se aplicaron los adhesivos y se esperó 10 segundos; o se frotaron los adhesivos durante 10 segundos. Luego se aplicó resina compuesta a la superficie dentinaria y se fotopolimerizó. Después de su almacenamiento en agua destilada a 37°C durante 24 h, todos los dientes unidos se cortaron en secciones de 1mm² utilizando una sierra de diamante de baja velocidad (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turquía) bajo agua corriente (n=15). Las secciones fueron sometidas a una fuerza de tracción a una velocidad de cruceta de 1mm/min en una máquina de prueba universal (Microtensile Tester, Bisco, IL, USA) y se midieron los valores de µTBS. Los datos fueron analizados utilizando la prueba de Kruskal-Wallis y la prueba U de Mann-Whitney. Los modos de falla fueron analizados bajo un estereomicroscopio. El prolongado tiempo de aplicación afectó significativamente a los µTBS (p<0,005). Se observó un aumento significativo de µTBS en la aplicación activa para el CUQ y el GPB. El TUB con una aplicación activa tuvo un valor de µTBS significativamente más bajo comparado con los otros adhesivos. El tiempo de aplicación prolongado causó una mejora significativa de la fuerza de adhesión en todos los adhesivos. La aplicación activa es efectiva para aumentar la fuerza de adhesión de la dentina, excepto para el TUB.


Assuntos
Cimentos Dentários/análise
8.
Biosci. j. (Online) ; 38: e38087, Jan.-Dec. 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1397493

RESUMO

Photosystem-inhibiting herbicides, such as diquat, act by inducing oxidative stress. However, oxidative damage impairs translocation, resulting in regrowth of the plants. The aim was to evaluate the effectiveness of diquat in controlling the growth of sourgrass exposed to different periods of darkness after application of the herbicide, as well as to evaluate the photosynthetic activity and the production of reactive oxygen species. Two experiments (field and greenhouse) were conducted by applying diquat (200 g a.i. ha-1) on sourgrass plants at the 3 to 4 tiller stage. The treated plants were subjected to different periods of darkness after diquat application (0, 1, 2, 3, 4, 5, and 6 h), in addition to the control treatment without any application. Growth inhibition and mass evaluations of the sourgrass plants were performed in both experiments, whereas photosynthetic activity and H2O2 accumulation in the leaves were evaluated in the greenhouse experiment. The results showed an increase in the sourgrass growth inhibition with an increase in the period of darkness after application. There was a need for a minimum of 6 h of darkness after diquat application to fully inhibit growth (100%) of the sourgrass, whereas plants that remained in the sun since application exhibited less than 50% inhibition. The increase in the period of darkness after diquat application resulted in a reduction in photosynthetic activity and, consequently, lower accumulation of H2O2. Thus, the maintenance of sourgrass in the dark for at least 6 h enables total control of the growth of the plants, preventing regrowth.


Assuntos
Estresse Oxidativo , Digitaria/crescimento & desenvolvimento , Controle de Plantas Daninhas , Herbicidas
9.
Antimicrob Resist Infect Control ; 11(1): 16, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35073993

RESUMO

BACKGROUND: The effectiveness of hand rubbing with alcohol-based handrub (ABHR) is impacted by several factors. To investigate these, World Health Organization (WHO) commissioned a systematic review. AIM: To evaluate the impact of ABHR volume, application time, rubbing friction and hand size on microbiological load reduction, hand surface coverage or drying time. METHODS: Medline, CINAHL, Web of Science and ScienceDirect databases were searched for healthcare or laboratory-based primary studies, published in English, (1980- February 2021), investigating the impact of ABHR volume, application time, rubbing friction or hand size on bacterial load reduction, hand coverage or drying time. Two reviewers independently performed data extraction and quality assessment. The results are presented narratively. FINDINGS: Twenty studies were included in the review. Categories included: ABHR volume, application time and rubbing friction. Sub-categories: bacterial load reduction, hand size, drying time or hand surface coverage. All used experimental or quasi-experimental designs. Findings showed as ABHR volume increased, bacterial load reduced, and drying times increased. Furthermore, one study showed that the application of sprayed ABHR without hand rubbing resulted in significantly lower bacterial load reduction than poured or sprayed ABHR with hand rubbing (- 0.70; 95%CI: - 1.13 to - 0.28). Evidence was heterogeneous in application time, volume, technique, and product. All studies were assessed as high risk of bias. CONCLUSIONS: There is insufficient evidence to change WHO recommendation of a palmful of ABHR in a cupped hand applied for 20-30 s or manufacturer-recommended volume applied for about 20 s (Centers for Disease Control and Prevention). Future hand hygiene research should standardise volume, application time, and consider hand size.


Assuntos
2-Propanol/uso terapêutico , Anti-Infecciosos Locais/uso terapêutico , Etanol/uso terapêutico , Higiene das Mãos/métodos , Higienizadores de Mão/uso terapêutico , Humanos
10.
J Cosmet Dermatol ; 21(7): 3095-3101, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34743412

RESUMO

BACKGROUND: Clinical studies have clarified the usefulness of moisturizers for dry skin diseases. However, few reports exist on the appropriate application of moisturizers with respect to the skin physiological functions. AIMS: To clarify the optimal moisturizer application method on the basis of skin physiological functions. METHODS: This study investigated the appropriate time, dose, and frequency of moisturizer application from the perspective of skin physiology. In healthy subjects, the stratum corneum water content (SCW) was compared between different moisturizer application times (immediately [≤5 min] and 90 min after bathing), doses (0.5, 1.0, and 2.0 mg/cm2 ), and frequencies (once and twice daily). Thereafter, patients with dry skin were treated with the moisturizer once or twice daily for 8 weeks at the time, and application dose was determined to be optimal for the healthy subjects; the moisturizing effect was evaluated based on the SCW, trypsin activity, and desmoglein 1 localization score in the stratum corneum. RESULTS: In healthy subjects, compared to at control sites, the SCW was significantly higher at sites treated with the moisturizer immediately after bathing, with 1.0 and 2.0 mg/cm2 of the moisturizer, and with once- and twice-daily applications. In patients with dry skin, the SCW was significantly higher compared to control sites and the desmoglein 1 localization score was significantly lower after 8 weeks only when the moisturizer was applied twice daily. CONCLUSIONS: Moisturizer application of ≥1.0 mg/cm2 twice daily (immediately after bathing at night and in the morning) had a moisturizing effect, as verified from the skin physiological functions.


Assuntos
Desmogleína 1 , Emolientes , Desmogleína 1/metabolismo , Epiderme , Humanos , Pele , Fenômenos Fisiológicos da Pele , Água/metabolismo , Perda Insensível de Água
11.
Dent J (Basel) ; 9(6)2021 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-34198701

RESUMO

Silver diamine fluoride (SDF) is a cost-effective method for arresting active dental caries. However, the limited cooperation of patients may lead to an SDF application time that is shorter than the recommended 1-3 min for carious lesions. Therefore, the aim of this study was to assess the effect of different application times of SDF on the degree of mineral precipitation in demineralized dentin. Demineralized dentin specimens from permanent maxillary molars were treated by applying 38% SDF for 30, 60, or 180 s. Water was applied in the control group. The specimens were immersed in simulated body fluid for 2 weeks, and the mineral precipitation in demineralized dentin was then analyzed using FTIR-ATR, SEM-EDX, and synchrotron radiation X-ray tomographic microscopy (SRXTM). The FTIR-ATR results showed a significant increase in mineral precipitation in the 180 s group after 1 week. However, after 2 weeks, the SRXTM images indicated comparable mineral density between the 30, 60, and 180 s groups. The precipitation of silver chloride and calcium phosphate crystals that occluded dentinal tubules was similar in all experimental groups. In conclusion, an application time of either 30, 60, or 180 s promoted a comparable degree of mineral precipitation in demineralized dentin.

12.
Clin Oral Investig ; 25(12): 6843-6855, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33939005

RESUMO

OBJECTIVES: This study aimed to assess the effect of application time on the microshear bond strength (µSBS) of three universal adhesives in demineralized and sound enamel before and after aging. MATERIALS AND METHODS: Bovine teeth (192) were prepared where buccal surfaces were ground and divided into two groups (sound enamel and demineralized enamel). The specimens in each group were divided into 12 subgroups by combining 3 adhesive agents (All-Bond Universal, Scotchbond Universal, and Tokuyama Universal Bond) × 4 adhesion strategy. Each adhesive was applied with either prolonged (PA) or reduced (RA) application time in etch-and-rinse or self-etch mode. Bonded composites were subjected to µSBS testing after 24-h or 2-year water storage. The results were evaluated using four-way ANOVA and Tukey's post-hoc test (α = 0.05). RESULTS: The µSBS of adhesives to sound enamel in both etching modes was mostly similar to demineralized enamel, regardless of application time and aging time. At 24-h, all adhesives with PA in self-etch mode showed higher µSBS when compared with RA, except Tokuyama Universal Bond, but after 2-year aging, no significant difference was found in µSBS between RA and PA. The µSBS of adhesives with PA in etch-and-rinse mode depended on used adhesive and enamel condition compared to RA, regardless of µSBS testing time. CONCLUSIONS: PA of adhesives did not reveal a significant difference in µSBS to enamel, regardless of substrate type and etching mode. CLINICAL RELEVANCE: After 2-year aging, the bond strength of universal adhesives presented no significant difference between PA and RA treatments.


Assuntos
Colagem Dentária , Adesivos Dentinários , Condicionamento Ácido do Dente , Adesivos , Animais , Bovinos , Cimentos Dentários , Esmalte Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento
13.
J Hosp Infect ; 111: 47-49, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33757811

RESUMO

We evaluated the bactericidal efficacy of two modified WHO-recommended alcohol-based hand rubs (3 mL) after a 15-s rubbing period using two different rub-in techniques (three vs six steps). The formulation based on 80% w/w ethanol and 0.5% v/v glycerol (modified WHO I) showed a mean log10-reduction of 3.63 ± 0.87 (six steps) and 3.80 ± 0.71 (three steps) which was inferior to the reference treatment (4.27 ± 0.98; six steps). The efficacy of the formulation based on 75% w/w isopropanol and 0.5% v/v glycerol (modified WHO II) was not inferior to the reference treatment for either rub-in technique.


Assuntos
2-Propanol , Anti-Infecciosos Locais , Etanol , Desinfecção das Mãos , Higienizadores de Mão , Mãos , Humanos , Organização Mundial da Saúde
14.
Front Microbiol ; 11: 1427, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32733402

RESUMO

Biochar is a new eco-material with the potential to control soilborne diseases. This study explored the relationship between the rhizosphere fungal community and the suppression of Phytophthora blight of pepper in the context of time after biochar application. A pot experiment was conducted and rhizosphere soils were sampled to determine the biochar-induced soil chemical properties, fungal community composition, and abundance of biocontrol fungi. The biochar-enriched fungal strains were screened by the selective isolation method, and their control effects against Phytophthora blight of pepper were determined using a pot experiment. Biochar treatments effectively inhibited pathogen growth and controlled the disease, with biochar applied immediately before planting (BC0) having greater effects than that applied 20 days before planting (BC20). Compared to the control, biochar-amended rhizosphere soils had a higher pH, available nutrient content, and fungal richness and diversity. Moreover, biochar treatments significantly increased the abundance of potential biocontrol fungi. The proliferation in BC0 was stronger as compared to that in BC20. Several strains belonging to Aspergillus, Chaetomium, and Trichoderma, which were enriched by biochar amendment, demonstrated effective control of Phytophthora blight of pepper. Canonical correspondence and Pearson's correlation analysis showed that a high content of soil-available nutrients in biochar treatments was favorable to the proliferation of beneficial fungi, which was negatively correlated with both the abundance of Phytophthora capsici and disease severity. In conclusion, biochar-mediated improvement in the fungal community suppressed the Phytophthora blight of pepper. The biochar application time had a great impact on the control effect, possibly due to the short-term proliferative effect of the biochar on biocontrol fungi.

15.
J Exp Orthop ; 7(1): 41, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32504155

RESUMO

BACKGROUND: Implant surface integrity and cement bonding are assumed to be sufficient in primary total knee replacements to stabilize implants for extended wear without concerns over delamination and loosening. Yet there exists a significant rate of aseptic loosening where failure at implant cement interface occurs. The aim of this study is to look at specific aspects leading to aseptic loosening of the total knee replacement, where cement adhesion to the implant results in the lowest pull off strength. METHODS: Virgin ceramic coated and uncoated chrome cobalt tibial trays were used in a pull off study using differing viscosities of cement at varied time intervals to compare which combination is strongest compared to which is least resistant to pull off testing. RESULTS: Low viscosity cement had a 44% (5.9 kg verses 3.3 kg, p < 0.001) higher pull-off strength compared to high viscosity cement. Coated implants had a 30% (3.9 kg verses 5.5 kg, p = 0.037) lower pull-off strength compared to non-coated. Testing measures were limited to cement utilization less than 5 minutes due to the poor adhesion of the dowels beyond this time. Finally, there was a significant difference in adhesion properties between brand names when utilizing low viscosity cement on the non-coated trays (10.34 kg for Simplex verses 4.87 for Palacos, p = 0.021). CONCLUSION: There are differences in adhesion properties between cement vendors, prompting significant concerns over the use of coated implants with particular cement types. Use of low viscosity cement on non-coated surfaces in the early liquid phase of cement curing was found to produce the best chance for adequate adhesion. This study demonstrates that there is variation in the adhesive properties of implants utilized in total knee replacements, and that the orthopedic community should consider not only the implant, cement, and curing time individually, but the overall integrity conferred from the combination of all of these variables.

16.
Animals (Basel) ; 10(3)2020 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-32182709

RESUMO

This study looks at the influence of time and/or frequency of multienzymes application on productivity, carcass characteristics, metabolic profile, and red blood cell characteristics of broiler chickens. Two hundred and eighty, one-day-old Arbor Acres broiler male chicks were randomly distributed into seven treatment groups. Each group consisted of eight replicates of five unsexed birds. The same basal diet was fed in a crumble form to all experimental groups: group one was the unsupplemented control that did not receive multienzymes supplementation. Additionally, multienzymes in water were supplemented in six groups in a factorial arrangement, including three times of application (starter time only which included days 1-21 of age, grower time only which included days 22-37 of age, and starter and grower time which included days 1-37 of age) and two application frequencies (continuously or intermittently). In the continuous application, the multienzymes were added to water over 24 h in a day, while in the intermittent frequency multienzymes were added to water for one day followed by a day off according to the time of application. Regardless of time and frequency of application, enzymes supplementation significantly increased growth rate, feed intake, European Production Index (EPI), protein digestibility, serum albumin, and high-density lipoprotein (HDL). Intermittent multienzymes application during days 1-21 of age or days 22-37 of age resulted in significantly greater growth, better feed conversion rate (FCR), and higher EPI of broilers during the whole rearing period than those under continuous multienzymes during different growth periods. Besides, intermittent multienzymes addition during days 1-37 of age improved FCR of broiler chicks compared to constant application. The intermittent addition of multienzymes during days 1-21 of age or 22-37 days of age and days 1-37 of age caused a significant increase in dry matter (DM) digestibility than the continuous application. The intermittent addition of multienzymes during days 1-21 of age significantly increased the digestibility of crude protein (CP), ether extract (EE), and crude fiber (CF) compared to continuous application. A similar trend was shown in the digestibility of CP and EE due to intermittent use during days 22-37 of age. Intermittent enzymes addition significantly increased high density lipoprotein (HDL) of groups receiving enzymes during days 22-37 of age compared to continuous application of enzymes. In conclusion, the use of multienzymes intermittently during days 1-21 of age and 22-37 days of age significantly increased growth, improved FCR, and raised EPI. Intermittent use can replace continuous multienzyme applications which can save 68.6% of the cost, even though further research is need from the cost-saving edge.

17.
J Agric Food Chem ; 68(2): 503-511, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31869217

RESUMO

Due to nonuniform maturation, some plants may not be at the recommended stage of maturity when preharvest glyphosate is applied. The objective of this study was to determine how preharvest glyphosate timing affects wheat starch physicochemical properties. Two wheat cultivars were grown in three locations, and glyphosate was applied at the soft dough stage (early application) and the ripe stage (commercial standard). Upon harvest, starch chemical characteristics were studied. The proportion of B-type starch granules was lower in treated samples, although the starch molecular weight was not affected. Rapidly digestible starch content was highest when glyphosate was applied at the ripe stage, and lowest in the control, and vice versa for slowly digestible starch. Additionally, flour pasting viscosity was significantly higher in samples treated at the soft dough stage. Overall, the effects on wheat starch physicochemical characteristics were more pronounced when glyphosate was applied at the soft dough stage of maturity.


Assuntos
Glicina/análogos & derivados , Herbicidas/farmacologia , Amido/química , Triticum/efeitos dos fármacos , Triticum/crescimento & desenvolvimento , Fenômenos Químicos , Glicina/farmacologia , Sementes/química , Sementes/efeitos dos fármacos , Sementes/crescimento & desenvolvimento , Sementes/metabolismo , Amido/metabolismo , Triticum/química , Triticum/metabolismo , Glifosato
18.
Dent Mater J ; 38(6): 892-899, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31366768

RESUMO

The purpose was to evaluate the effect of a hydrophilic amide monomer on µTBS of one-step adhesive to dentin at different application times. Clearfil Universal Bond Quick (UBQ), experimental adhesive (UBQexp; same compositions as UBQ but hydrophilic amide monomer was replaced with 2-hydroxyethyl methacrylate), Clearfil SE ONE and Clearfil SE Bond were applied to midcoronal dentin prepared with 600-grit SiC at different application time (0, 10, 20 and 40 s). Water sorption (Wsp) and the ultimate tensile strength (UTS) of polymerized adhesives were also measured. UBQ showed significantly lower Wsp and higher UTS than UBQexp. At each application time, UBQ exhibited significantly higher µTBSs than UBQexp. UBQ showed the highest µTBS at 0 s application time among all the adhesives. When the application time was prolonged from 0 s to 10 s, only UBQ showed no significant difference. The hydrophilic amide monomer increased µTBS with reduction in Wsp and increase in the UTS and may allow a shortened application time.


Assuntos
Colagem Dentária , Amidas , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
19.
Expert Opin Drug Deliv ; 16(3): 199-206, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30773938

RESUMO

OBJECTIVES: A tearable dissolving microneedle system (TD-MN system) was developed for shortening the time required to administer drugs into the skin through the dissolving microneedles. METHODS: TD-MN system consisted of an array of tearable dissolving microneedles (TD-MN) and micro-pillars. The microneedle tips had a female part to integrate with the micro-pillars. The micro-pillars exerted a vertical force to cause the separation of the tips from the base. The separation force exerted by six TD-MN arrays with different thicknesses of separation region was measured. The TD-MN system with trypan blue was inserted into porcine skin to observe the separation of the microneedle tips, and then calcein was added separately to observe drug diffusion into the skin. RESULTS: The thickness of the tearable region and the depth of the female part were a function of the concentration and volume of the molding solution. The separation force increased as the thickness of the tearable region increased. Nine tips were successfully separated from the base by applying a force of through the micro-pillars. CONCLUSIONS: The TD-MN system could provide immediate administration of a drug, resulting in improved patient convenience as well as delivery of the correct drug dose.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Agulhas , Pele/metabolismo , Administração Cutânea , Animais , Difusão , Microinjeções , Suínos
20.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-787368

RESUMO

The purpose of this study was to evaluate the effect of application time and phosphoric acid etching of 8th generation adhesives containing functional monomer on adhesive performance in primary teeth.80 extracted non-carious human primary teeth were selected and divided into 8 groups based on 3 factors: (1) adhesive: G-Premio bond and Single bond universal; (2) application time: shortened time and manufacture's instruction; (3) acid etching mode: self-etching and total-etching. Shear bond strength was measured using a universal testing machine, and fractured surface were observed under scanning electron microscope. Microleakage was evaluated by dye penetration depth.G-Premio bond were not significant different in shear bond strength and microleakage depending on application time of adhesive and acid etching mode. In Single bond universal, shear bond strength of short application time was significantly lower than that of long adhesive application time (p = 0.014). Clinically applicable shear bond strength values (> 17 MPa) were identified in all groups.These results suggested that G-Premio bond be used clinically for a short application time without phosphoric acid etching.


Assuntos
Humanos , Adesivos , Métodos , Dente Decíduo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...